Volumn 19, Issue 4, 2009, Pages 800-808

A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations

Author keywords

Computed tomography; Pulmonary nodule; Reproducibility; Segmentation; Volumetry

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; INTERMETHOD COMPARISON; LUNG METASTASIS; LUNG NODULE; MALE; PRIORITY JOURNAL; REPRODUCIBILITY; VOLUMETRY; COMPARATIVE STUDY; INFORMATION PROCESSING; LUNG NEOPLASMS; MEDICAL INFORMATICS; MIDDLE AGED; PROCEDURES; RADIOGRAPHY; SOLITARY PULMONARY NODULE; VERY ELDERLY;

EID: 62649137035     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-008-1229-x     Document Type: Article
Times cited : (134)

References (16)
  • 1
    • 34248641387 scopus 로고    scopus 로고
    • Computer-aided detection and automated CT volumetry of pulmonary nodules
    • Marten K, Engelke C (2007) Computer-aided detection and automated CT volumetry of pulmonary nodules. Eur Radiol 17:888-901
    • (2007) Eur Radiol , vol.17 , pp. 888-901
    • Marten, K.1    Engelke, C.2
  • 2
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors
    • Therasse P, Arbuck SG, Eisenhauer EA et al (2000) New guidelines to evaluate the response to treatment in solid tumors. J Natl Cancer Inst 92:205-216
    • (2000) J Natl Cancer Inst , vol.92 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3
  • 3
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • Yankelevitz DF, Reeves AP, Kostis WJ et al (2000) Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation. Radiology 217:251-256
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3
  • 4
    • 36249024875 scopus 로고    scopus 로고
    • Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT influence of inspiration level, nodule size, and segmentation performance
    • Gietema HA, Schaefer-Prokop CM, Mali WPTM et al (2007) Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT influence of inspiration level, nodule size, and segmentation performance. Radiology 245:888-894
    • (2007) Radiology , vol.245 , pp. 888-894
    • Gietema, H.A.1    Schaefer-Prokop, C.M.2    Mali, W.P.T.M.3
  • 5
    • 0842345498 scopus 로고    scopus 로고
    • Volumetric measurements of pulmonary nodules at multi-row detector CT: In vivo reproducibility
    • Wormanns D, Kohl G, Klotz E et al (2004) Volumetric measurements of pulmonary nodules at multi-row detector CT: In vivo reproducibility. Eur Radiol 14:86-92
    • (2004) Eur Radiol , vol.14 , pp. 86-92
    • Wormanns, D.1    Kohl, G.2    Klotz, E.3
  • 6
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the fleischner society
    • MacMahon H, Austin JHM, Gamsu G et al (2005) Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the fleischner society. Radiology 237:395-400
    • (2005) Radiology , vol.237 , pp. 395-400
    • MacMahon, H.1    Austin, J.H.M.2    Gamsu, G.3
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    • Kostis WJ, Yankelevitz DF, Reeves AP et al (2004) Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 231:446-452
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3
  • 9
    • 33646913058 scopus 로고    scopus 로고
    • Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • Goodman LR, Gulsun M, Washington L et al (2006) Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. Am J Roentgenol 186:989-994
    • (2006) Am J Roentgenol , vol.186 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3
  • 10
    • 44449158674 scopus 로고    scopus 로고
    • Pulmonary nodule volume: Effects of reconstruction parameters on automated measurements-a phantom study
    • Ravenel JG, Leue WM, Nietert PJ et al (2008) Pulmonary nodule volume: effects of reconstruction parameters on automated measurements-a phantom study. Radiology 247:400-408
    • (2008) Radiology , vol.247 , pp. 400-408
    • Ravenel, J.G.1    Leue, W.M.2    Nietert, P.J.3
  • 11
    • 34248632699 scopus 로고    scopus 로고
    • Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
    • Das M, Ley-Zaporozhan J, Gietema HA et al (2007) Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners. Eur Radiol 17:1979-1984
    • (2007) Eur Radiol , vol.17 , pp. 1979-1984
    • Das, M.1    Ley-Zaporozhan, J.2    Gietema, H.A.3
  • 12
    • 34147179045 scopus 로고    scopus 로고
    • Automated volumetry of solid pulmonary nodules in a phantom: Accuracy across different CT scanner technologies
    • Das M, Muhlenbruch G, Katoh M et al (2007) Automated volumetry of solid pulmonary nodules in a phantom: Accuracy across different CT scanner technologies. Invest Radiol 42:297-302
    • (2007) Invest Radiol , vol.42 , pp. 297-302
    • Das, M.1    Muhlenbruch, G.2    Katoh, M.3
  • 13
    • 0042931348 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volume measurement at chest CT-phantom study
    • Ko JP, Rusinek H, Jacobs EL et al (2003) Small pulmonary nodules: Volume measurement at chest CT-phantom study. Radiology 228:864-870
    • (2003) Radiology , vol.228 , pp. 864-870
    • Ko, J.P.1    Rusinek, H.2    Jacobs, E.L.3
  • 14
    • 0032765011 scopus 로고    scopus 로고
    • Small pulmonary nodules: Evaluation with repeat CTùPreliminary experience
    • Yankelevitz DF, Gupta R, Zhao B, Henschke CI (1999) Small pulmonary nodules: Evaluation with repeat CTùPreliminary experience. Radiology 212:561-566
    • (1999) Radiology , vol.212 , pp. 561-566
    • Yankelevitz, D.F.1    Gupta, R.2    Zhao, B.3    Henschke, C.I.4
  • 15
    • 18844382442 scopus 로고    scopus 로고
    • Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy
    • Goo JM, Tongdee T, Tongdee R et al (2005) Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy. Radiology 235:850-856
    • (2005) Radiology , vol.235 , pp. 850-856
    • Goo, J.M.1    Tongdee, T.2    Tongdee, R.3
  • 16
    • 40749155455 scopus 로고    scopus 로고
    • Automated volumetry of pulmonary nodules on multidetector CT: Influence of slice thickness, reconstruction algorithm and tube current. Preliminary results
    • Larici AR, Storto ML, Torge M et al (2008) Automated volumetry of pulmonary nodules on multidetector CT: Influence of slice thickness, reconstruction algorithm and tube current. Preliminary results. Radiol Med (Torino) 113:29-42
    • (2008) Radiol Med (Torino) , vol.113 , pp. 29-42
    • Larici, A.R.1    Storto, M.L.2    Torge, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.