메뉴 건너뛰기




Volumn 40, Issue 11, 2013, Pages

Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)

Author keywords

accuracy and precision; ASiR; iterative reconstruction algorithm; lung nodule 3D volume quantification; MBIR (Veo)

Indexed keywords

BIOLOGICAL ORGANS; IMAGE SEGMENTATION; ITERATIVE METHODS; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOISE ABATEMENT; SILICON; SILICON COMPOUNDS;

EID: 84889633438     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4823463     Document Type: Article
Times cited : (55)

References (16)
  • 1
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada
    • 10.1093/jnci/92.3.205
    • P. Therasse, S. G. Arbuck, E. A. Eisenhauer, J. Wanders, R. S. Kaplan, L. Rubinstein, J. Verweij, M. Van Glabbeke, A. T. van Oosterom, M. C. Christian, and S. G. Gwyther, " New guidelines to evaluate the response to treatment in solid tumors. European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada.," J. Natl. Cancer Inst. 92, 205-216 (2000). 10.1093/jnci/92.3.205
    • (2000) J. Natl. Cancer Inst. , vol.92 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3    Wanders, J.4    Kaplan, R.S.5    Rubinstein, L.6    Verweij, J.7    Van Glabbeke, M.8    Van Oosterom, A.T.9    Christian, M.C.10    Gwyther, S.G.11
  • 2
    • 0003486931 scopus 로고
    • World Health Organization, (World Health Organization, Geneva) (sold by WHO Publications Centre USA
    • World Health Organization, WHO Handbook for Reporting Results of Cancer Treatment (World Health Organization, Geneva, 1979) (sold by WHO Publications Centre USA).
    • (1979) WHO Handbook for Reporting Results of Cancer Treatment
  • 3
    • 64949119251 scopus 로고    scopus 로고
    • Noncalcified lung nodules: Volumetric assessment with thoracic CT
    • 10.1148/radiol.2511071897
    • M. A. Gavrielides, L. M. Kinnard, K. J. Myers, and N. Petrick, " Noncalcified lung nodules: Volumetric assessment with thoracic CT.," Radiology 251, 26-37 (2009). 10.1148/radiol.2511071897
    • (2009) Radiology , vol.251 , pp. 26-37
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3    Petrick, N.4
  • 4
    • 84864713607 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative reconstruction technique
    • 10.1007/s00330-012-2452-z
    • M. Katsura, I. Matsuda, M. Akahane, J. Sato, H. Akai, K. Yasaka, A. Kunimatsu, and K. Ohtomo, " Model-based iterative reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative reconstruction technique.," Eur. Radiol. 22, 1613-1623 (2012). 10.1007/s00330-012-2452-z
    • (2012) Eur. Radiol. , vol.22 , pp. 1613-1623
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3    Sato, J.4    Akai, H.5    Yasaka, K.6    Kunimatsu, A.7    Ohtomo, K.8
  • 5
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm: Initial clinical experience
    • 10.1148/radiol.09090094
    • D. Marin, R. C. Nelson, S. T. Schindera, S. Richard, R. S. Youngblood, T. T. Yoshizumi, and E. Samei, " Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm: Initial clinical experience.," Radiology 254, 145-153 (2010). 10.1148/radiol.09090094
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3    Richard, S.4    Youngblood, R.S.5    Yoshizumi, T.T.6    Samei, E.7
  • 6
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • 10.2214/AJR.09.2953
    • A. C. Silva, H. J. Lawder, A. Hara, J. Kujak, and W. Pavlicek, " Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm.," AJR, Am. J. Roentgenol. 194, 191-199 (2010). 10.2214/AJR.09.2953
    • (2010) AJR, Am. J. Roentgenol. , vol.194 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3    Kujak, J.4    Pavlicek, W.5
  • 7
    • 84879284577 scopus 로고    scopus 로고
    • Precision of iodine quantification in hepatic CT: Effects of iterative reconstruction with various imaging parameters
    • 10.2214/AJR.12.9658
    • B. Chen, D. Marin, S. Richard, D. Husarik, R. Nelson, and E. Samei, " Precision of iodine quantification in hepatic CT: Effects of iterative reconstruction with various imaging parameters.," Am. J. Roentgenol. 200, W475-W482 (2013). 10.2214/AJR.12.9658
    • (2013) Am. J. Roentgenol. , vol.200
    • Chen, B.1    Marin, D.2    Richard, S.3    Husarik, D.4    Nelson, R.5    Samei, E.6
  • 8
    • 80052921583 scopus 로고    scopus 로고
    • New iterative reconstruction techniques for cardiovascular computed tomography: How do they work, and what are the advantages and disadvantages?
    • 10.1016/j.jcct.2011.07.001
    • R. C. Nelson, S. Feuerlein, and D. T. Boll, " New iterative reconstruction techniques for cardiovascular computed tomography: How do they work, and what are the advantages and disadvantages?," J. Cardiovasc. Comput. Tomogr. 5, 286-292 (2011). 10.1016/j.jcct.2011.07.001
    • (2011) J. Cardiovasc. Comput. Tomogr. , vol.5 , pp. 286-292
    • Nelson, R.C.1    Feuerlein, S.2    Boll, D.T.3
  • 9
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • 10.1118/1.2789499
    • J.-B. Thibault, K. D. Sauer, C. A. Bouman, and J. Hsieh, " A three-dimensional statistical approach to improved image quality for multislice helical CT.," Med. Phys. 34, 4526-4544 (2007). 10.1118/1.2789499
    • (2007) Med. Phys. , vol.34 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 11
    • 0042931348 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volume measurement at chest CT-phantom study
    • 10.1148/radiol.2283020059
    • J. P. Ko, H. Rusinek, E. L. Jacobs, J. S. Babb, M. Betke, G. McGuinness, and D. P. Naidich, " Small pulmonary nodules: Volume measurement at chest CT-phantom study.," Radiology 228, 864-870 (2003). 10.1148/radiol. 2283020059
    • (2003) Radiology , vol.228 , pp. 864-870
    • Ko, J.P.1    Rusinek, H.2    Jacobs, E.L.3    Babb, J.S.4    Betke, M.5    McGuinness, G.6    Naidich, D.P.7
  • 12
    • 42649084308 scopus 로고    scopus 로고
    • Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: A phantom study
    • 10.1088/0031-9155/53/5/009
    • T. W. Way, H. P. Chan, M. M. Goodsitt, B. Sahiner, L. M. Hadjiiski, C. Zhou, and A. Chughtai, " Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: A phantom study.," Phys. Med. Biol. 53, 1295-1312 (2008). 10.1088/0031-9155/53/5/009
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1295-1312
    • Way, T.W.1    Chan, H.P.2    Goodsitt, M.M.3    Sahiner, B.4    Hadjiiski, L.M.5    Zhou, C.6    Chughtai, A.7
  • 13
    • 84857587615 scopus 로고    scopus 로고
    • Quantitative CT: Technique dependence of volume estimation on pulmonary nodules
    • 10.1088/0031-9155/57/5/1335
    • B. Chen, H. Barnhart, S. Richard, J. Colsher, M. Amurao, and E. Samei, " Quantitative CT: Technique dependence of volume estimation on pulmonary nodules.," Phys. Med. Biol. 57, 1335-1348 (2012). 10.1088/0031-9155/57/5/ 1335
    • (2012) Phys. Med. Biol. , vol.57 , pp. 1335-1348
    • Chen, B.1    Barnhart, H.2    Richard, S.3    Colsher, J.4    Amurao, M.5    Samei, E.6
  • 14
    • 77953421826 scopus 로고    scopus 로고
    • Applications of the repeatability of quantitative imaging biomarkers: A review of statistical analysis of repeat data sets
    • 10.1593/tlo.09268
    • H. X. Barnhart and D. P. Barboriak, " Applications of the repeatability of quantitative imaging biomarkers: A review of statistical analysis of repeat data sets.," Transl. Oncol. 2, 231-235 (2009). 10.1593/tlo.09268
    • (2009) Transl. Oncol. , vol.2 , pp. 231-235
    • Barnhart, H.X.1    Barboriak, D.P.2
  • 16
    • 84864249070 scopus 로고    scopus 로고
    • Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms
    • 10.1118/1.4725171
    • S. Richard, D. B. Husarik, G. Yadava, S. N. Murphy, and E. Samei, " Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms.," Med. Phys. 39, 4115-4122 (2012). 10.1118/1.4725171
    • (2012) Med. Phys. , vol.39 , pp. 4115-4122
    • Richard, S.1    Husarik, D.B.2    Yadava, G.3    Murphy, S.N.4    Samei, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.