메뉴 건너뛰기




Volumn 18, Issue 14, 2010, Pages 15244-15255

A resource for the assessment of lung nodule size estimation methods: Database of thoracic CT scans of an anthropomorphic phantom

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; BLOOD VESSELS; DATABASE SYSTEMS; DIAGNOSIS; PHANTOMS;

EID: 84886952447     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.18.015244     Document Type: Article
Times cited : (59)

References (14)
  • 3
    • 33745953240 scopus 로고    scopus 로고
    • Measures of response: RECIST, WHO, and new alternatives
    • C. C. Jaffe, "Measures of response: RECIST, WHO, and new alternatives," J. Clin. Oncol. 24(20), 3245-3251 (2006).
    • (2006) J. Clin. Oncol. , vol.24 , Issue.20 , pp. 3245-3251
    • Jaffe, C.C.1
  • 4
    • 64949119251 scopus 로고    scopus 로고
    • Noncalcified lung nodules: Volumetric assessment with thoracic CT
    • M. A. Gavrielides, L. M. Kinnard, K. J. Myers, and N. Petrick, "Noncalcified lung nodules: volumetric assessment with thoracic CT," Radiology 251(1), 26-37 (2009).
    • (2009) Radiology , vol.251 , Issue.1 , pp. 26-37
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3    Petrick, N.4
  • 8
    • 0141954913 scopus 로고    scopus 로고
    • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images
    • W. J. Kostis, A. P. Reeves, D. F. Yankelevitz, and C. I. Henschke, "Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images," IEEE Trans. Med. Imaging 22(10), 1259-1274 (2003).
    • (2003) IEEE Trans. Med. Imaging , vol.22 , Issue.10 , pp. 1259-1274
    • Kostis, W.J.1    Reeves, A.P.2    Yankelevitz, D.F.3    Henschke, C.I.4
  • 11
    • 66749116108 scopus 로고    scopus 로고
    • A template-based approach for the analysis of lung nodules in a volumetric CT phantom, study
    • M. A. Gavrielides, R. Zeng, L. M. Kinnard, K. J. Myers, and N. Petrick, "A template-based approach for the analysis of lung nodules in a volumetric CT phantom, study," Proc. SPIE 7260, 726009 (2009).
    • (2009) Proc. SPIE , vol.7260 , pp. 726009
    • Gavrielides, M.A.1    Zeng, R.2    Kinnard, L.M.3    Myers, K.J.4    Petrick, N.5
  • 12
    • 84886951310 scopus 로고    scopus 로고
    • Information-theoretic approach for analyzing bias and variance in lung nodule size estimation with CT: A phantom study
    • in press
    • M. A. Gavrielides, R. Zeng, L. M. Kinnard, K. J. Myers, and N. Petrick, "Information-theoretic approach for analyzing bias and variance in lung nodule size estimation with CT: a phantom study," IEEE Trans. Med. Imaging. in press).
    • IEEE Trans. Med. Imaging.
    • Gavrielides, M.A.1    Zeng, R.2    Kinnard, L.M.3    Myers, K.J.4    Petrick, N.5
  • 13
    • 84886948444 scopus 로고    scopus 로고
    • Approximations of noise structures in helical multidetector CT scans: Application to lung nodule volume estimation
    • R. Zeng, N. Petrick, M. A. Gavrielides, and K. J. Myers, "Approximations of noise structures in helical multidetector CT scans: application to lung nodule volume estimation," Proc. SPIE 7624, 762415 (2010).
    • (2010) Proc. SPIE , vol.7624 , pp. 762415
    • Zeng, R.1    Petrick, N.2    Gavrielides, M.A.3    Myers, K.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.