메뉴 건너뛰기




Volumn 29, Issue 10, 2010, Pages 1795-1807

Information-theoretic approach for analyzing bias and variance in lung nodule size estimation with CT: A phantom study

Author keywords

Lung nodule; Matched filter; Phantom study; Thoracic computed tomography (CT); Volume estimation

Indexed keywords

ACCURACY AND PRECISION; ADAPTIVE MODELS; BIAS AND VARIANCE; COMPUTED TOMOGRAPHY; COMPUTED TOMOGRAPHY DATA; EFFECT OF FACTORS; IMAGING PARAMETERS; INFORMATION-THEORETIC APPROACH; LOW BIAS; LUNG NODULE; OBJECT ACQUISITION; OBJECT OF INTERESTS; PHANTOM STUDIES; RECONSTRUCTION PARAMETERS; RECONSTRUCTION PROCESS; SIZE ESTIMATION; SIZE MEASUREMENTS; SUM OF ABSOLUTE DIFFERENCES; VOLUME ESTIMATIONS;

EID: 77957585579     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2010.2052466     Document Type: Article
Times cited : (35)

References (42)
  • 1
    • 64949119251 scopus 로고    scopus 로고
    • Noncalcified lung nodules: Volumetric assessment with thoracic CT
    • M. A. Gavrielides, L. M. Kinnard, K. J. Myers, and N. Petrick, Noncalcified lung nodules: Volumetric assessment with thoracic CT, Radiology, vol.251, pp. 26-37, 2009.
    • (2009) Radiology , vol.251 , pp. 26-37
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3    Petrick, N.4
  • 3
    • 33645697952 scopus 로고    scopus 로고
    • Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans
    • Apr.
    • J. M. Kuhnigk, V. Dicken, L. Bornemann, A. Bakai, D. Wormanns, S. Krass, and H. O. Peitgen, Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans, IEEE Trans. Med. Imag., vol.25, no.4, pp. 417-434, Apr. 2006.
    • (2006) IEEE Trans. Med. Imag. , vol.25 , Issue.4 , pp. 417-434
    • Kuhnigk, J.M.1    Dicken, V.2    Bornemann, L.3    Bakai, A.4    Wormanns, D.5    Krass, S.6    Peitgen, H.O.7
  • 4
    • 0141954913 scopus 로고    scopus 로고
    • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images
    • Oct.
    • W. J. Kostis, A. P. Reeves, D. F. Yankelevitz, and C. I. Henschke, Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images, IEEE Trans. Med. Imag., vol.22, no.10, pp. 1259-1274, Oct. 2003.
    • (2003) IEEE Trans. Med. Imag. , vol.22 , Issue.10 , pp. 1259-1274
    • Kostis, W.J.1    Reeves, A.P.2    Yankelevitz, D.F.3    Henschke, C.I.4
  • 5
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    • May.
    • W. J. Kostis, D. F. Yankelevitz, A. P. Reeves, S. C. Fluture, and C. I. Henschke, Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT, Radiology, vol.231, pp. 446-452, May 2004.
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3    Fluture, S.C.4    Henschke, C.I.5
  • 7
    • 0032663031 scopus 로고    scopus 로고
    • Threedimensional multicriterion automatic segmentation of pulmonary nodules of helical computed tomography images
    • B. Zhao, A. P. Reeves, D. F. Yankelevitz, and C. I. Henschke, Threedimensional multicriterion automatic segmentation of pulmonary nodules of helical computed tomography images, Opt. Eng., vol.38, pp. 1340-1347, 1999.
    • (1999) Opt. Eng. , vol.38 , pp. 1340-1347
    • Zhao, B.1    Reeves, A.P.2    Yankelevitz, D.F.3    Henschke, C.I.4
  • 8
    • 33846651571 scopus 로고    scopus 로고
    • Lung cancer: Computerized quantification of tumor response-initial results
    • Dec.
    • B. Zhao, L. H. Schwartz, C. S. Moskowitz, M. S. Ginsberg, N. A. Rizvi, and M. G. Kris, Lung cancer: Computerized quantification of tumor response-initial results, Radiology, vol.241, pp. 892-898, Dec. 2006.
    • (2006) Radiology , vol.241 , pp. 892-898
    • Zhao, B.1    Schwartz, L.H.2    Moskowitz, C.S.3    Ginsberg, M.S.4    Rizvi, N.A.5    Kris, M.G.6
  • 9
    • 77955274962 scopus 로고    scopus 로고
    • Computer aided segmentation of pulmonary nodules: Automated vasculature cutoff in thick- and thin-slice CT
    • R. Wiemker, P. Rogala, E. Hein, T. Blaffert, and P. Rosch, Computer aided segmentation of pulmonary nodules: Automated vasculature cutoff in thick- and thin-slice CT, in Proc. Comput. Assist. Radiol. Surg. (CARS 2003), 2003, vol.1256, pp. 965-970.
    • (2003) Proc. Comput. Assist. Radiol. Surg. (CARS 2003) , vol.1256 , pp. 965-970
    • Wiemker, R.1    Rogala, P.2    Hein, E.3    Blaffert, T.4    Rosch, P.5
  • 11
    • 19044373465 scopus 로고    scopus 로고
    • Robust anisotropic Gaussian fitting for volumetric characterization of pulmonary nodules in multislice CT
    • Mar.
    • K. Okada, D. Comaniciu, and A. Krishnan, Robust anisotropic Gaussian fitting for volumetric characterization of pulmonary nodules in multislice CT, IEEE Trans. Med. Imag., vol.24, no.3, pp. 409-423, Mar. 2005.
    • (2005) IEEE Trans. Med. Imag. , vol.24 , Issue.3 , pp. 409-423
    • Okada, K.1    Comaniciu, D.2    Krishnan, A.3
  • 14
    • 33646913058 scopus 로고    scopus 로고
    • Herent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • Apr.
    • L. R. Goodman, M. Gulsun, L. Washington, P. G. Nagy, and K. L. Piacsek, Herent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements, AJR Am. J. Roentgenol., vol.186, pp. 989-994, Apr. 2006.
    • (2006) AJR Am. J. Roentgenol. , vol.186 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3    Nagy, P.G.4    Piacsek, K.L.5
  • 16
    • 77958013643 scopus 로고    scopus 로고
    • Lung nodule volumetry: Segmentation algorithms within the same software package cannot be used interchangeably
    • DOI 10.1007/s00330-010-1749-z, 2010
    • H. Ashraf, B. de Hoop, S. B. Shaker, A. Dirksen, K. S. Bach, H. Hansen, M. Prokop, and J. H. Pedersen, Lung nodule volumetry: Segmentation algorithms within the same software package cannot be used interchangeably, Eur. Radiol., no. DOI 10.1007/s00330-010-1749-z, 2010.
    • Eur. Radiol., No.
    • Ashraf, H.1    De Hoop, B.2    Shaker, S.B.3    Dirksen, A.4    Bach, K.S.5    Hansen, H.6    Prokop, M.7    Pedersen, J.H.8
  • 17
    • 62649137035 scopus 로고    scopus 로고
    • A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
    • B. de Hoop, H. Gietema, B. van Ginneken, P. Zanen, G. Groenewegen, and M. Prokop, A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations, Eur. Radiol., vol.19, pp. 800-808, 2009.
    • (2009) Eur. Radiol. , vol.19 , pp. 800-808
    • De Hoop, B.1    Gietema, H.2    Van Ginneken, B.3    Zanen, P.4    Groenewegen, G.5    Prokop, M.6
  • 18
    • 36249024875 scopus 로고    scopus 로고
    • Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT- Influence of inspiration level, nodule size, and segmentation performance
    • H. A. Gietema, C. M. Schaefer-Prokop, W. P. T. M. Mali, G. Groenewegen, and M. Prokop, Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT- Influence of inspiration level, nodule size, and segmentation performance, Radiology, vol.245, pp. 888-894, 2007.
    • (2007) Radiology , vol.245 , pp. 888-894
    • Gietema, H.A.1    Schaefer-Prokop, C.M.2    Mali, W.P.T.M.3    Groenewegen, G.4    Prokop, M.5
  • 21
    • 33747145292 scopus 로고    scopus 로고
    • Software volumetric evaluation of doubling times for differentiating benign versus malignant pulmonary nodules
    • Jul.
    • M. P. Revel, A. Merlin, S. Peyrard, R. Triki, S. Couchon, G. Chatellier, and G. Frija, Software volumetric evaluation of doubling times for differentiating benign versus malignant pulmonary nodules, AJR Am. J. Roentgenol., vol.187, pp. 135-142, Jul. 2006.
    • (2006) AJR Am. J. Roentgenol. , vol.187 , pp. 135-142
    • Revel, M.P.1    Merlin, A.2    Peyrard, S.3    Triki, R.4    Couchon, S.5    Chatellier, G.6    Frija, G.7
  • 24
    • 0035384869 scopus 로고    scopus 로고
    • Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique
    • Jul.
    • Y. Lee, T. Hara, H. Fujita, S. Itoh, and T. Ishigaki, Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique, IEEE Trans. Med. Imag., vol.20, no.7, pp. 595-604, Jul. 2001.
    • (2001) IEEE Trans. Med. Imag. , vol.20 , Issue.7 , pp. 595-604
    • Lee, Y.1    Hara, T.2    Fujita, H.3    Itoh, S.4    Ishigaki, T.5
  • 25
    • 0035544610 scopus 로고    scopus 로고
    • Patient-specific models for lung nodule detection and surveillance in CT images
    • Dec.
    • M. S. Brown, M. F. McNitt-Gray, J. G. Goldin, R. D. Suh, J. W. Sayre, and D. R. Aberle, Patient-specific models for lung nodule detection and surveillance in CT images, IEEE Trans. Med. Imag., vol.20, no.12, pp. 1242-1250, Dec. 2001.
    • (2001) IEEE Trans. Med. Imag. , vol.20 , Issue.12 , pp. 1242-1250
    • Brown, M.S.1    McNitt-Gray, M.F.2    Goldin, J.G.3    Suh, R.D.4    Sayre, J.W.5    Aberle, D.R.6
  • 27
    • 33847606950 scopus 로고    scopus 로고
    • Lung metastases detection in CT images using 3-D template matching
    • P. Wang, A. DeNunzio, P. Okunieff, and W. G. ODell, Lung metastases detection in CT images using 3-D template matching, Med. Phys., vol.34, pp. 915-922, 2007.
    • (2007) Med. Phys. , vol.34 , pp. 915-922
    • Wang, P.1    Denunzio, A.2    Okunieff, P.3    Odell, W.G.4
  • 28
    • 66749175840 scopus 로고    scopus 로고
    • Volume change determination of metastatic lung tumors in CT images using 3-D template matching
    • R. D. Ambrosini, P. Wang, and W. G. ODell, Volume change determination of metastatic lung tumors in CT images using 3-D template matching, in Proc. SPIE, Orlando, FL, 2009, p. 726035.
    • (2009) Proc. SPIE, Orlando, FL , pp. 726035
    • Ambrosini, R.D.1    Wang, P.2    Odell, W.G.3
  • 29
    • 84886948444 scopus 로고    scopus 로고
    • Approximations of noise structures in helical multi-detector CT scans: Application to lung nodule volume estimation
    • R. Zeng, N. Petrick, M. A. Gavrielides, and K. J. Myers, Approximations of noise structures in helical multi-detector CT scans: Application to lung nodule volume estimation, in Proc. SPIE, Orlando, FL, 2010, vol.7624, p. 762415.
    • Proc. SPIE, Orlando, FL, 2010 , vol.7624 , pp. 762415
    • Zeng, R.1    Petrick, N.2    Gavrielides, M.A.3    Myers, K.J.4
  • 30
    • 0041328321 scopus 로고    scopus 로고
    • Fast normalized cross correlation for defect detection
    • D. M. Tsai and C. T. Lin, Fast normalized cross correlation for defect detection, Pattern Recognit. Lett., vol.24, pp. 2625-2631, 2003.
    • (2003) Pattern Recognit. Lett. , vol.24 , pp. 2625-2631
    • Tsai, D.M.1    Lin, C.T.2
  • 35
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Jan.
    • H. Hu, Multi-slice helical CT: Scan and reconstruction, Med. Phys., vol.26, pp. 5-18, Jan. 1999.
    • (1999) Med. Phys. , vol.26 , pp. 5-18
    • Hu, H.1
  • 36
    • 0025950712 scopus 로고
    • Elliptic fit of objects in two and three dimensions by moment of inertia optimization
    • B. Chaudhuri and G. Samanta, Elliptic fit of objects in two and three dimensions by moment of inertia optimization, Pattern Recongnit. Lett., vol.12, pp. 1-7, 1991.
    • (1991) Pattern Recongnit. Lett. , vol.12 , pp. 1-7
    • Chaudhuri, B.1    Samanta, G.2
  • 37
    • 20744443150 scopus 로고    scopus 로고
    • Automated detection of pulmonary nodules on CT images: Effect of section thickness and reconstruction interval-initial results
    • Jul.
    • J. S. Kim, J. H. Kim, G. Cho, and K. T. Bae, Automated detection of pulmonary nodules on CT images: Effect of section thickness and reconstruction interval-initial results, Radiology, vol.236, pp. 295-299, Jul. 2005.
    • (2005) Radiology , vol.236 , pp. 295-299
    • Kim, J.S.1    Kim, J.H.2    Cho, G.3    Bae, K.T.4
  • 38
    • 0141629562 scopus 로고    scopus 로고
    • Effect of varying CT section width on volumetric measurement of lung tumors and application of compensatory equations
    • Oct.
    • H. T. Winer-Muram, S. G. Jennings, C. A. Meyer, Y. Liang, A. M. Aisen, R. D. Tarver, and R. C. McGarry, Effect of varying CT section width on volumetric measurement of lung tumors and application of compensatory equations, Radiology, vol.229, pp. 184-194, Oct. 2003.
    • (2003) Radiology , vol.229 , pp. 184-194
    • Winer-Muram, H.T.1    Jennings, S.G.2    Meyer, C.A.3    Liang, Y.4    Aisen, A.M.5    Tarver, R.D.6    McGarry, R.C.7
  • 39
    • 2342550126 scopus 로고    scopus 로고
    • Characterization of small nodules by automatic segmentation of X-ray computed tomography images
    • P. Tao, F. Griess, Y. Lvov, M. Mineyev, B. Zhao, D. Levin, and L. Kaufman, Characterization of small nodules by automatic segmentation of X-ray computed tomography images, J. Comput. Assist Tomogr., vol.28, pp. 372-377, 2004.
    • (2004) J. Comput. Assist Tomogr. , vol.28 , pp. 372-377
    • Tao, P.1    Griess, F.2    Lvov, Y.3    Mineyev, M.4    Zhao, B.5    Levin, D.6    Kaufman, L.7
  • 40
    • 42649084308 scopus 로고    scopus 로고
    • Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3-D active contour segmentation: A phantom study
    • T. W. Way, H.-P. Chan, M. M. Goodsitt, B. Sahiner, L. M. Hadjiiski, C. Zhou, and A. Chughtai, Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3-D active contour segmentation: A phantom study, Phys. Med. Biol., vol.53, pp. 1295-1312, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 1295-1312
    • Way, T.W.1    Chan, H.-P.2    Goodsitt, M.M.3    Sahiner, B.4    Hadjiiski, L.M.5    Zhou, C.6    Chughtai, A.7
  • 42
    • 84886952447 scopus 로고    scopus 로고
    • A resource for the assessment of lung nodule size estimation methods: Database of thoracic CT scans of an anthropomorphic phantom
    • M. A. Gavrielides, L. M. Kinnard, K. J. Myers, J. Peregoy, W. F. Pritchard, R. Zeng, J. Esparza, J. Karanian, and N. Petrick, A resource for the assessment of lung nodule size estimation methods: Database of thoracic CT scans of an anthropomorphic phantom, Optics Express, vol.18, no.14, pp. 15244-15255, 2010.
    • (2010) Optics Express , vol.18 , Issue.14 , pp. 15244-15255
    • Gavrielides, M.A.1    Kinnard, L.M.2    Myers, K.J.3    Peregoy, J.4    Pritchard, W.F.5    Zeng, R.6    Esparza, J.7    Karanian, J.8    Petrick, N.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.