1
-
-
0027426230
-
The response to particulate debris
-
Howie D. W., Haynes D. R., Rogers S. D., McGee M. A., Pearcy M. J.. The response to particulate debris. Orthop. Clinics N. America. 1993 ; 24 (4). 571-581
-
(1993)
Orthop. Clinics N. America
, vol.24
, Issue.4
, pp. 571-581
-
-
Howie, D.W.1
Haynes, D.R.2
Rogers, S.D.3
McGee, M.A.4
Pearcy, M.J.5
-
3
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
Nevelos J., Ingham E., Doyle C., Streicher R., Nevelos A., Walter W., Fisher J.. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J. Arthroplasty. 2000 ; 15 (6). 793-795
-
(2000)
J. Arthroplasty
, vol.15
, Issue.6
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
Streicher, R.4
Nevelos, A.5
Walter, W.6
Fisher, J.7
-
4
-
-
0035481958
-
A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions
-
Bowsher J. G., Shelton J. C.. A hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions. Wear. 2001 ; 250 (1-12). 167-179
-
(2001)
Wear
, vol.250
, Issue.112
, pp. 167-179
-
-
Bowsher, J.G.1
Shelton, J.C.2
-
6
-
-
0030152744
-
A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty
-
Maxian T. A., Brown T. D., Pedersen D. R., Callaghan J. J.. A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. J. Biomechanics. 1996 ; 29 (5). 687-692
-
(1996)
J. Biomechanics
, vol.29
, Issue.5
, pp. 687-692
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
7
-
-
0030345394
-
The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear
-
Maxian T. A., Brown T. D., Pedersen D. R., Callaghan J. J.. The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear. Clin. Orthop. Related Res.. 1996 ; 333: 41-50
-
(1996)
Clin. Orthop. Related Res.
, vol.333
, pp. 41-50
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
8
-
-
0030698011
-
Finite element analysis of acetabular wear. Validation, and backing and fixation effects
-
Maxian T. A., Brown T. D., Pedersen D. R., McKellop H. A., Lu B., Callaghan J.J.. Finite element analysis of acetabular wear. Validation, and backing and fixation effects. Clin. Orthop. Related Res.. 1997 ; 344: 111-117
-
(1997)
Clin. Orthop. Related Res.
, vol.344
, pp. 111-117
-
-
Maxian, T.A.1
Brown, T.D.2
Pedersen, D.R.3
McKellop, H.A.4
Lu, B.5
Callaghan, J.J.6
-
9
-
-
0342663760
-
-
PhD Thesis, University of Iowa, Iowa City, Iowa, USA
-
MaxianT. A.Development and application of a finite element formulation for estimating sliding wear in total hip arthroplasty, PhD Thesis, University of Iowa, Iowa City, Iowa, USA, 1997.
-
(1997)
Development and Application of A Finite Element Formulation for Estimating Sliding Wear in Total Hip Arthroplasty
-
-
Maxian, T.A.1
-
10
-
-
0036960511
-
Local head roughening as a factor contributing to variability of total hip wear: A finite element analysis
-
Brown T.D., Stewart K. J., Nieman J. C., Pedersen D. R., Callaghan J.J. Local head roughening as a factor contributing to variability of total hip wear: A finite element analysis. J. Biomech. Engng. 2002 ; 124 (6). 691-698
-
(2002)
J. Biomech. Engng
, vol.124
, Issue.6
, pp. 691-698
-
-
Brown, T.D.1
Stewart, K.J.2
Nieman, J.C.3
Pedersen, D.R.4
Callaghan, J.J.5
-
11
-
-
0032053277
-
Wear of polyethylene cups in total hip arthroplasty: A parametric mathematical model
-
Pietrabissa R., Raimondi M., Di Martino E.. Wear of polyethylene cups in total hip arthroplasty: A parametric mathematical model. Med. Engng Physics. 1998 ; 20 (3). 199-210
-
(1998)
Med. Engng Physics
, vol.20
, Issue.3
, pp. 199-210
-
-
Pietrabissa, R.1
Raimondi, M.2
Di Martino, E.3
-
12
-
-
0035228123
-
Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components
-
Raimondi M. T., Santambrogio C., Pietrabissa R., Raffelini F., Molfetta L.. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine. 2001 ; 215 (4). 377-391
-
(2001)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.215
, Issue.4
, pp. 377-391
-
-
Raimondi, M.T.1
Santambrogio, C.2
Pietrabissa, R.3
Raffelini, F.4
Molfetta, L.5
-
13
-
-
0036169065
-
An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty
-
Teoh S. H., Chan W. H., Thampuran R.. An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty. J. Biomechanics. 2002 ; 35 (3). 323-330
-
(2002)
J. Biomechanics
, vol.35
, Issue.3
, pp. 323-330
-
-
Teoh, S.H.1
Chan, W.H.2
Thampuran, R.3
-
14
-
-
0037213115
-
The computer simulation of wear behavior appearing in total hip prosthesis
-
Wu J. S. S., Hung J. P., Shu C. S., Chen J. H.. The computer simulation of wear behavior appearing in total hip prosthesis. Computer Meth. Programs Biomedicine. 2003 ; 70 (1). 81-91
-
(2003)
Computer Meth. Programs Biomedicine
, vol.70
, Issue.1
, pp. 81-91
-
-
Wu, J.S.S.1
Hung, J.P.2
Shu, C.S.3
Chen, J.H.4
-
15
-
-
0032071068
-
Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement
-
Kurtz S. M., Ochoa J. A., White C. V., Srivastav S., Cournoyer J.. Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J. Biomechanics. 1998 ; 31 (5). 431-437
-
(1998)
J. Biomechanics
, vol.31
, Issue.5
, pp. 431-437
-
-
Kurtz, S.M.1
Ochoa, J.A.2
White, C.V.3
Srivastav, S.4
Cournoyer, J.5
-
16
-
-
0022107624
-
The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
-
Bartel D. L., Burstein A. H., Toda M. D., Edwards D. L.. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J. Biomech. Engng. 1985 ; 107 (3). 193-199
-
(1985)
J. Biomech. Engng
, vol.107
, Issue.3
, pp. 193-199
-
-
Bartel, D.L.1
Burstein, A.H.2
Toda, M.D.3
Edwards, D.L.4
-
17
-
-
0032610912
-
An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements
-
Jin Z. M., Heng S. M., Ng H. W., Auger D. D.. An axisymmetric contact model of ultra high molecular weight polyethylene cups against metallic femoral heads for artificial hip joint replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine. 1999 ; 213 (4). 317-327
-
(1999)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.213
, Issue.4
, pp. 317-327
-
-
Jin, Z.M.1
Heng, S.M.2
Ng, H.W.3
Auger, D.D.4
-
18
-
-
0035864336
-
Properties of crosslinked ultra-high-molecular-weight polyethylene
-
Lewis G.. Properties of crosslinked ultra-high-molecular-weight polyethylene. Biomaterials. 2001 ; 22 (4). 371-401
-
(2001)
Biomaterials
, vol.22
, Issue.4
, pp. 371-401
-
-
Lewis, G.1
-
19
-
-
0014574695
-
Measurement of hip-joint motion during walking - Evaluation of an electrogoniometric method
-
Johnston R. C., Smith G. L.. Measurement of hip-joint motion during walking - evaluation of an electrogoniometric method. J. Bone Jt Surg.. 1969 ; 51: 1083-1094
-
(1969)
J. Bone Jt Surg.
, vol.51
, pp. 1083-1094
-
-
Johnston, R.C.1
Smith, G.L.2
-
20
-
-
0002989262
-
Forces transmitted by joints in the human body
-
Paul J. P.. Forces transmitted by joints in the human body. Proc. Instn Mech. Engrs. 1967 ; 181 (3). 8-15
-
(1967)
Proc. Instn Mech. Engrs
, vol.181
, Issue.3
, pp. 8-15
-
-
Paul, J.P.1
-
21
-
-
0032865043
-
A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials
-
Jin Z. M., Dowson D.. A full numerical analysis of hydrodynamic lubrication in artificial hip joint replacements constructed from hard materials. Proc. Instn Mech. Engrs, Part C: J. Mechanical Engineering Science. 1999 ; 213 (C4). 355-370
-
(1999)
Proc. Instn Mech. Engrs, Part C: J. Mechanical Engineering Science
, vol.213
, Issue.C4
, pp. 355-370
-
-
Jin, Z.M.1
Dowson, D.2
-
22
-
-
0029253653
-
The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
-
Barbour P. S. M., Barton D. C., Fisher J.. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses. Wear. 1995 ; 181 (1). 250-257
-
(1995)
Wear
, vol.181
, Issue.1
, pp. 250-257
-
-
Barbour, P.S.M.1
Barton, D.C.2
Fisher, J.3
-
23
-
-
0035727965
-
The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements
-
Sathasivam S., Walker P. S., Campbell P. A., Rayner K.. The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. J. Biomed. Mater. Res.. 2001 ; 58 (3). 282-290
-
(2001)
J. Biomed. Mater. Res.
, vol.58
, Issue.3
, pp. 282-290
-
-
Sathasivam, S.1
Walker, P.S.2
Campbell, P.A.3
Rayner, K.4
-
24
-
-
0035235398
-
Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement
-
Wang A., Essner A., Klein R.. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine. 2001 ; 215 (2). 133-139
-
(2001)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.215
, Issue.2
, pp. 133-139
-
-
Wang, A.1
Essner, A.2
Klein, R.3
-
25
-
-
0347516482
-
Microscopic asperity contact and deformation of UHMWPE bearing surfaces
-
Wang F. C., Jin Z. M., McEwen H. M.J., Fisher J.. Microscopic asperity contact and deformation of UHMWPE bearing surfaces. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine. 2003 ; 217: 477-490
-
(2003)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.217
, pp. 477-490
-
-
Wang, F.C.1
Jin, Z.M.2
McEwen, H.M.J.3
Fisher, J.4
-
26
-
-
8644278179
-
Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts?
-
Vassiliou K., Unsworth A.. Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-high molecular weight polyethylene contacts?. Proc. Instn Mech. Engrs, Part H: J Engineering in Medicine. 2004 ; 218: 101-107
-
(2004)
Proc. Instn Mech. Engrs, Part H: J Engineering in Medicine
, vol.218
, pp. 101-107
-
-
Vassiliou, K.1
Unsworth, A.2
-
27
-
-
0035892402
-
Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device
-
Saikko V., Calonius O., Keranen J.. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device. J. Biomed. Mater. Res.. 2001 ; 57 (4). 506-512
-
(2001)
J. Biomed. Mater. Res.
, vol.57
, Issue.4
, pp. 506-512
-
-
Saikko, V.1
Calonius, O.2
Keranen, J.3
-
28
-
-
84930385134
-
Penetration, creep and wear of highly crosslinked UHMWPE in a hip joint simulation
-
Memphis, Tennessee, USA
-
GalvinA.InghamE.JinZ. M.FisherJ.Penetration, creep and wear of highly crosslinked UHMWPE in a hip joint simulation. InProceedings of the Society for Biomaterials 30th Annual Meeting, Memphis, Tennessee, USA, 2005, p. 78.
-
(2005)
Proceedings of the Society for Biomaterials 30th Annual Meeting
, pp. 78
-
-
Galvin, A.1
Ingham, E.2
Jin, Z.M.3
Fisher, J.4
-
29
-
-
0345868762
-
An augmented hybrid constitutive model for simulation of unloading and cyclic loading behavior of conventional and highly crosslinked UHMWPE
-
Bergstrom J. S., Rimnac C. M., Kurtz S. M.. An augmented hybrid constitutive model for simulation of unloading and cyclic loading behavior of conventional and highly crosslinked UHMWPE. Biomaterials. 2004 ; 25 (11). 2171-2178
-
(2004)
Biomaterials
, vol.25
, Issue.11
, pp. 2171-2178
-
-
Bergstrom, J.S.1
Rimnac, C.M.2
Kurtz, S.M.3
-
30
-
-
0036205442
-
Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
-
Saikko V., Calonius O.. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. J. Biomechanics. 2002 ; 35 (4). 455-464
-
(2002)
J. Biomechanics
, vol.35
, Issue.4
, pp. 455-464
-
-
Saikko, V.1
Calonius, O.2
-
32
-
-
0020317686
-
The walking activity of patients with artificial hip joints
-
Wallbridge N., Dowson D.. The walking activity of patients with artificial hip joints. Engng Medicine. 1982 ; 11 (2). 95-96
-
(1982)
Engng Medicine
, vol.11
, Issue.2
, pp. 95-96
-
-
Wallbridge, N.1
Dowson, D.2
-
33
-
-
0034889413
-
Comparative study of the activity of total hip arthroplasty patients and normal subjects
-
Goldsmith A. A., Dowson D., Wroblewski B. M., Siney P. D., Fleming P. A., Lane J. M., Stone M. H., Walker R.. Comparative study of the activity of total hip arthroplasty patients and normal subjects. J. Arthroplasty. 2001 ; 16 (5). 613-619
-
(2001)
J. Arthroplasty
, vol.16
, Issue.5
, pp. 613-619
-
-
Goldsmith, A.A.1
Dowson, D.2
Wroblewski, B.M.3
Siney, P.D.4
Fleming, P.A.5
Lane, J.M.6
Stone, M.H.7
Walker, R.8
-
34
-
-
0036713559
-
Average patient walking activity approaches 2 million cycles per year: Pedometers under-record walking activity
-
Silva M., Shepherd E. F., Jackson W. O., Dorey F. J., Schmalzried T. P.. Average patient walking activity approaches 2 million cycles per year: Pedometers under-record walking activity. J. Arthroplasty. 2002 ; 17 (6). 693-697
-
(2002)
J. Arthroplasty
, vol.17
, Issue.6
, pp. 693-697
-
-
Silva, M.1
Shepherd, E.F.2
Jackson, W.O.3
Dorey, F.J.4
Schmalzried, T.P.5
-
35
-
-
0141680572
-
Force track analysis of contemporary hip simulators
-
Calonius O., Saikko V.. Force track analysis of contemporary hip simulators. J. Biomechanics. 2003 ; 36 (11). 1719-1726
-
(2003)
J. Biomechanics
, vol.36
, Issue.11
, pp. 1719-1726
-
-
Calonius, O.1
Saikko, V.2
-
36
-
-
0028115613
-
Comparison of hip force calculations and measurements in the same patient
-
Brand R. A., Pedersen D. R., Davy D. W., Kotzar G. M., Kotzar G. M., Heiple K. G., Goldberg V. M.. Comparison of hip force calculations and measurements in the same patient. J. Arthroplasty. 1994 ; 9: 45-51
-
(1994)
J. Arthroplasty
, vol.9
, pp. 45-51
-
-
Brand, R.A.1
Pedersen, D.R.2
Davy, D.W.3
Kotzar, G.M.4
Kotzar, G.M.5
Heiple, K.G.6
Goldberg, V.M.7
-
37
-
-
0032253879
-
Temporal and spatial distributions of directional counterface motion at the acetabular bearing surface in total hip arthroplasty
-
Pedersen D. R., Brown T. D., Maxian T. A., Callaghan J. J.. Temporal and spatial distributions of directional counterface motion at the acetabular bearing surface in total hip arthroplasty. Iowa Orthop. J.. 1998 ; 18: 43-53
-
(1998)
Iowa Orthop. J.
, vol.18
, pp. 43-53
-
-
Pedersen, D.R.1
Brown, T.D.2
Maxian, T.A.3
Callaghan, J.J.4
-
38
-
-
0029421369
-
Experimental and theoretical study of the contact mechanics of five total knee joint replacements
-
Stewart T., Jin Z. M., Shaw D., Auger D. D., Stone M., Fisher J.. Experimental and theoretical study of the contact mechanics of five total knee joint replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine. 1995 ; 209: 225-231
-
(1995)
Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine
, vol.209
, pp. 225-231
-
-
Stewart, T.1
Jin, Z.M.2
Shaw, D.3
Auger, D.D.4
Stone, M.5
Fisher, J.6
-
39
-
-
0035217940
-
Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
-
Muratoglu O. K., Bragdon C. R., O'Connor D., Perinchief R. S., Estok D. M., Jasty M., Harris W. H.. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept. J. Arthroplasty. 2001 ; 16 (8). 24-30
-
(2001)
J. Arthroplasty
, vol.16
, Issue.8
, pp. 24-30
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.3
Perinchief, R.S.4
Estok, D.M.5
Jasty, M.6
Harris, W.H.7
-
40
-
-
0043065573
-
Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene
-
Turell M., Wang A. G., Bellare A.. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene. Wear. 2003 ; 255 (7-12). 1034-1039
-
(2003)
Wear
, vol.255
, Issue.712
, pp. 1034-1039
-
-
Turell, M.1
Wang, A.G.2
Bellare, A.3
-
41
-
-
2442447086
-
Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis
-
Saikko V., Calonius O., Keranen J.. Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis. J. Biomed. Mater. Res. B, Appl. Biomater.. 2004 ; 69 (2). 141-148
-
(2004)
J. Biomed. Mater. Res. B, Appl. Biomater.
, vol.69
, Issue.2
, pp. 141-148
-
-
Saikko, V.1
Calonius, O.2
Keranen, J.3
|