-
2
-
-
0025343488
-
Effect of femoral head size on wear of the polyethylene acetabular component
-
Livermore J.Ilstrupand D.Morrey B.Effect of femoral head size on wear of the polyethylene acetabular component J. Bone Joint Surg. 72-A4 1990 518-528
-
(1990)
J. Bone Joint Surg.
, vol.72 A
, Issue.4
, pp. 518-528
-
-
Livermore, J.1
Ilstrupand, D.2
Morrey, B.3
-
4
-
-
0032128352
-
Retrieved total hip prostheses. Part I. The effects of cup thickness, head size and fusion defects on wear
-
Oonishi H.Tsuji E.Kim Y.Retrieved total hip prostheses. Part I. The effects of cup thickness, head size and fusion defects on wear J. Mater. Sci. 9 1998 394-401
-
(1998)
J. Mater. Sci.
, vol.9
, pp. 394-401
-
-
Oonishi, H.1
Tsuji, E.2
Kim, Y.3
-
5
-
-
0002292336
-
Wear in total hip replacement
-
H.C. Amstutz (Ed.) Churchill Livingstone, New York
-
I.C. Clarke, J.M. Kabo, Wear in total hip replacement, in: H.C. Amstutz (Ed.), Hip Arthroplasty, Churchill Livingstone, New York, 1991.
-
(1991)
Hip Arthroplasty
-
-
Clarke, I.C.1
Kabo, J.M.2
-
6
-
-
0031105323
-
Polyethylene wear in total hip and knee arthroplasties
-
Lewis G.Polyethylene wear in total hip and knee arthroplasties J. Biomed. Mater. Res. (Appl. Biomater.) 38 1997 55-75
-
(1997)
J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.38
, pp. 55-75
-
-
Lewis, G.1
-
8
-
-
0028798063
-
The problem is osteolysis
-
Harris W.The problem is osteolysis Clin. Orthop. Rel. Res. 311 1995 46-53
-
(1995)
Clin. Orthop. Rel. Res.
, vol.311
, pp. 46-53
-
-
Harris, W.1
-
9
-
-
0026550544
-
The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy
-
Schmalzried T.Kwong L.Jasty M.Sedlacek R.Haire T.O'Connor D.Bragdon C.Kabo J.Malcolm A.Harris W.The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy Clin. Orthop. Rel. Res. 274 1992 60-78
-
(1992)
Clin. Orthop. Rel. Res.
, vol.274
, pp. 60-78
-
-
Schmalzried, T.1
Kwong, L.2
Jasty, M.3
Sedlacek, R.4
Haire, T.5
O'Connor, D.6
Bragdon, C.7
Kabo, J.8
Malcolm, A.9
Harris, W.10
-
12
-
-
0028349883
-
Size and shape of biomaterial wear debris
-
Savio J.Overcamp L.Black J.Size and shape of biomaterial wear debris Clin. Mater. 15 1994 101-119
-
(1994)
Clin. Mater.
, vol.15
, pp. 101-119
-
-
Savio, J.1
Overcamp, L.2
Black, J.3
-
14
-
-
0029748331
-
Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements
-
Campbell P.Doorn P.Dorey F.Amstutz H.Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements Proc. Inst. Mech. Engrs., Part H 210 1996 167-175
-
(1996)
Proc. Inst. Mech. Engrs.
, vol.210
, Issue.PART H
, pp. 167-175
-
-
Campbell, P.1
Doorn, P.2
Dorey, F.3
Amstutz, H.4
-
15
-
-
0029852622
-
Loci of movement of selected points on the femoral head during normal gait
-
Ramamurti B.Bragdon C.O'Connor D.Lowenstein J.Jasty M.Estok D.Harris W.Loci of movement of selected points on the femoral head during normal gait J. Arthroplasty 117 1996 852-855
-
(1996)
J. Arthroplasty
, vol.11
, Issue.7
, pp. 852-855
-
-
Ramamurti, B.1
Bragdon, C.2
O'Connor, D.3
Lowenstein, J.4
Jasty, M.5
Estok, D.6
Harris, W.7
-
16
-
-
0006544376
-
Orientation softening in the deformation and wear of ultra-high polyethylene
-
Wang A.Sun D.Yau S.-S.Edwards B.Sokol M.Essner A.Polineni V.Stark C.Dumbelton J.Orientation softening in the deformation and wear of ultra-high polyethylene Wear 203-204 1997 230-241
-
(1997)
Wear
, vol.203-204
, pp. 230-241
-
-
Wang, A.1
Sun, D.2
Yau, S.-S.3
Edwards, B.4
Sokol, M.5
Essner, A.6
Polineni, V.7
Stark, C.8
Dumbelton, J.9
-
17
-
-
0032616832
-
Type of motion and lubricant in wear simulation of polyethylene acetabular cup
-
Saikko V.Ahlroos T.Type of motion and lubricant in wear simulation of polyethylene acetabular cup Proc. Inst. Mech. Engrs., Part H 213 1999 301-310
-
(1999)
Proc. Inst. Mech. Engrs.
, vol.213
, Issue.PART H
, pp. 301-310
-
-
Saikko, V.1
Ahlroos, T.2
-
19
-
-
0029725748
-
Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
-
Wang A.Stark C.Dumbleton J.Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses Proc. Inst. Mech. Engrs., Part H 210 1996 141-155
-
(1996)
Proc. Inst. Mech. Engrs.
, vol.210
, Issue.PART H
, pp. 141-155
-
-
Wang, A.1
Stark, C.2
Dumbleton, J.3
-
20
-
-
0031099405
-
The significance of non-linear motion in the wear screening of orthopaedic implant materials
-
Wang A.Polineni V.Essner A.Sokol M.Sun D.Stark C.Dumbleton J.The significance of non-linear motion in the wear screening of orthopaedic implant materials Test. Eval. 252 1997 239-245
-
(1997)
Test. Eval.
, vol.25
, Issue.2
, pp. 239-245
-
-
Wang, A.1
Polineni, V.2
Essner, A.3
Sokol, M.4
Sun, D.5
Stark, C.6
Dumbleton, J.7
-
21
-
-
0031594091
-
Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
-
Wang A.Essner A.Polineni V.Stark C.Dumbleton J.Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements Tribol. Int. 311-3 1998 17-33
-
(1998)
Tribol. Int.
, vol.31
, Issue.1-3
, pp. 17-33
-
-
Wang, A.1
Essner, A.2
Polineni, V.3
Stark, C.4
Dumbleton, J.5
-
22
-
-
0033755919
-
Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation
-
Bennett D.Orr J.Baker R.Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation J. Arthroplasty 157 2000 909-915
-
(2000)
J. Arthroplasty
, vol.15
, Issue.7
, pp. 909-915
-
-
Bennett, D.1
Orr, J.2
Baker, R.3
-
23
-
-
0035280295
-
A unified theory of wear for ultra-high molecular weight polyethylene in multidirectional sliding
-
Wang A.A unified theory of wear for ultra-high molecular weight polyethylene in multidirectional sliding Wear 248 2001 38-47
-
(2001)
Wear
, vol.248
, pp. 38-47
-
-
Wang, A.1
-
24
-
-
85031132470
-
The mechanism of dislocation in THR varies with head size and joint position
-
PE077
-
I. Sahni, P. Noble, R. Bartz, J. Alexander, V. Paravic, N. Kadakia, The mechanism of dislocation in THR varies with head size and joint position, in: Proceedings of the 67th Annual Meeting of the AAOS, 2000, PE077.
-
(2000)
Proceedings of the 67th Annual Meeting of the AAOS
-
-
Sahni, I.1
Noble, P.2
Bartz, R.3
Alexander, J.4
Paravic, V.5
Kadakia, N.6
|