메뉴 건너뛰기




Volumn 29, Issue 5, 1996, Pages 687-692

A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty

Author keywords

Contact stress; Finite element; Polyethylene; Sliding distance; Wear

Indexed keywords

FINITE ELEMENT METHOD; INTERFACES (MATERIALS); JOINTS (ANATOMY); MATHEMATICAL MODELS; PHYSIOLOGICAL MODELS; POLYETHYLENES; STRESS ANALYSIS; STRESS CONCENTRATION; WEAR OF MATERIALS;

EID: 0030152744     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/0021-9290(95)00125-5     Document Type: Article
Times cited : (170)

References (14)
  • 1
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris-induced osteolysis
    • Amstutz, H. C., Campbell, P., Kossovsky, N. and Clarke, I. C. (1991) Mechanism and clinical significance of wear debris-induced osteolysis Clin. Orthop. 276, 7-18.
    • (1991) Clin. Orthop. , vol.276 , pp. 7-18
    • Amstutz, H.C.1    Campbell, P.2    Kossovsky, N.3    Clarke, I.C.4
  • 2
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surfaces
    • Archard, J. F. (1953) Contact and rubbing of flat surfaces. J. Appl. Phys. 24, 981-988.
    • (1953) J. Appl. Phys. , vol.24 , pp. 981-988
    • Archard, J.F.1
  • 3
    • 0022108298 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints III: The measurement of internal volume changes in explanted charnley sockets after 2-16 years in vivo and the determination of wear factors
    • Atkinson, J. R., Dowson, D., Isaac, J. H. and Wroblewski, B. M. (1985) Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints III: the measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors. Wear 104, 225-244.
    • (1985) Wear , vol.104 , pp. 225-244
    • Atkinson, J.R.1    Dowson, D.2    Isaac, J.H.3    Wroblewski, B.M.4
  • 4
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
    • Bartel, D. L., Burstein, A. H., Toda, M. D. and Edwards, D. L. (1985) The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J. Biomed. Engng 107, 193-199.
    • (1985) J. Biomed. Engng , vol.107 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 5
    • 0004688604 scopus 로고
    • Evaluation and design of the articular surface
    • Edited by V. M. Goldberg, Raven Press, New York
    • Bartel, D. L., Rimnac, C. M. and Wright, T. M. (1991) Evaluation and design of the articular surface. In Controversies of Total Knee Arthroplasty (Edited by V. M. Goldberg), pp. 61-73. Raven Press, New York.
    • (1991) Controversies of Total Knee Arthroplasty , pp. 61-73
    • Bartel, D.L.1    Rimnac, C.M.2    Wright, T.M.3
  • 7
    • 0006489715 scopus 로고
    • Changes in pelvic load transfer due to variations in acetabular cup design
    • Dalstra, M., Bechtold, J. E. and Kyle R. F. (1993) Changes in pelvic load transfer due to variations in acetabular cup design. Trans. 39th Orthop. Res. Soc. 442.
    • (1993) Trans. 39th Orthop. Res. Soc. , pp. 442
    • Dalstra, M.1    Bechtold, J.E.2    Kyle, R.F.3
  • 9
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore, J., Ilstrup, D. and Morrey, B. (1990) Effect of femoral head size on wear of the polyethylene acetabular component. J. Bone Jt Surg. 72A, 518-528.
    • (1990) J. Bone Jt Surg. , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 10
    • 0024303173 scopus 로고
    • Discretization pressure-wear theory for bodies in sliding contact
    • Marshek, K. M. and Chen, H. H. (1989) Discretization pressure-wear theory for bodies in sliding contact. J. Tribology 111, 95-100.
    • (1989) J. Tribology , vol.111 , pp. 95-100
    • Marshek, K.M.1    Chen, H.H.2
  • 11
    • 0018431399 scopus 로고
    • Wear mechanisms for ultra-high molecular weight polyethylene in the total hip prosthesis
    • Nusbaum, H. J., Rose, R. M., Paul, I. L., Crugnola, A. M. and Radin, E. L. (1979) Wear mechanisms for ultra-high molecular weight polyethylene in the total hip prosthesis. J. Appl. Polymer Sci. 23, 777-789.
    • (1979) J. Appl. Polymer Sci. , vol.23 , pp. 777-789
    • Nusbaum, H.J.1    Rose, R.M.2    Paul, I.L.3    Crugnola, A.M.4    Radin, E.L.5
  • 13
    • 0018537364 scopus 로고
    • Contact pressure dependence of wear rates of ultra high molecular weight polyethylene
    • Rostoker, W. and Galante, J. O. (1979) Contact pressure dependence of wear rates of ultra high molecular weight polyethylene. J. Biomed. Mater. Res. 13, 957-964.
    • (1979) J. Biomed. Mater. Res. , vol.13 , pp. 957-964
    • Rostoker, W.1    Galante, J.O.2
  • 14
    • 0025747096 scopus 로고
    • Tribological behavior of various materials and surfaces against polyethylene
    • Streicher, R. M. and Schön, R. (1991) Tribological behavior of various materials and surfaces against polyethylene. Trans. 17th Ann. Mtg Soc. Biomat., 289.
    • (1991) Trans. 17th Ann. Mtg Soc. Biomat. , pp. 289
    • Streicher, R.M.1    Schön, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.