-
1
-
-
79961108629
-
Reduced lung-cancer mortality with low-dose computed tomography screening
-
The National Lung Screening Trial Research Team Reduced lung-cancer mortality with low-dose computed tomography screening N Engl J Med 365 2011 395 409
-
(2011)
N Engl J Med
, vol.365
, pp. 395-409
-
-
-
2
-
-
84874688661
-
American Cancer Society lung cancer screening guidelines
-
R. Wender, E.T. Fontham, and E. Barrera Jr. American Cancer Society lung cancer screening guidelines CA Cancer J Clin 62 2 2013 107 117
-
(2013)
CA Cancer J Clin
, vol.62
, Issue.2
, pp. 107-117
-
-
Wender, R.1
Fontham, E.T.2
Barrera, E.3
-
3
-
-
2142695134
-
Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
-
D.J. Brenner Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer Radiology 231 2004 440 445
-
(2004)
Radiology
, vol.231
, pp. 440-445
-
-
Brenner, D.J.1
-
4
-
-
84862255365
-
Benefits and harms of CT screening for lung cancer. A systematic review
-
P.B. Bach, J.N. Mirkin, and T.K. Oliver Benefits and harms of CT screening for lung cancer. A systematic review JAMA 307 2012 2418 2429
-
(2012)
JAMA
, vol.307
, pp. 2418-2429
-
-
Bach, P.B.1
Mirkin, J.N.2
Oliver, T.K.3
-
6
-
-
76449091107
-
Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience
-
P. Prakash, M.K. Kalra, and S.R. Digumarthy Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience J Comput Assist Tomogr 34 2010 40 45
-
(2010)
J Comput Assist Tomogr
, vol.34
, pp. 40-45
-
-
Prakash, P.1
Kalra, M.K.2
Digumarthy, S.R.3
-
7
-
-
62849112550
-
Is iterative reconstruction ready for MDCT?
-
J. Xu, M. Mahesh, and B.M. Tsui Is iterative reconstruction ready for MDCT? J Am Coll Radiol 6 2009 274 276
-
(2009)
J Am Coll Radiol
, vol.6
, pp. 274-276
-
-
Xu, J.1
Mahesh, M.2
Tsui, B.M.3
-
8
-
-
84876366477
-
Reduced-dose low-voltage chest CT angiography with sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection
-
F. Pontana, J. Pagniez, and A. Duhamel Reduced-dose low-voltage chest CT angiography with sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection Radiology 267 2 2013 609 618
-
(2013)
Radiology
, vol.267
, Issue.2
, pp. 609-618
-
-
Pontana, F.1
Pagniez, J.2
Duhamel, A.3
-
9
-
-
84878725244
-
Iterative reconstruction techniques for computed tomography. Part 1: Technical principles
-
M.J. Willemink, P.A. de Jong, T. Leiner, L.M. de Heer, and R.A. Nievelstein Iterative reconstruction techniques for computed tomography. Part 1: Technical principles Eur Radiol 23 2013 1623 1631
-
(2013)
Eur Radiol
, vol.23
, pp. 1623-1631
-
-
Willemink, M.J.1
De Jong, P.A.2
Leiner, T.3
De Heer, L.M.4
Nievelstein, R.A.5
-
10
-
-
79955036642
-
Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study
-
S. Singh, M.K. Kalra, and M.D. Gilman Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study Radiology 259 2 2011 565 573
-
(2011)
Radiology
, vol.259
, Issue.2
, pp. 565-573
-
-
Singh, S.1
Kalra, M.K.2
Gilman, M.D.3
-
11
-
-
84876036668
-
Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms
-
V. Vardhanabhuti, R.J. Loader, G.R. Mitchell, R.D. Riordan, and C.A. Roobottom Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms Am J Roentgenol 200 2013 545 552
-
(2013)
Am J Roentgenol
, vol.200
, pp. 545-552
-
-
Vardhanabhuti, V.1
Loader, R.J.2
Mitchell, G.R.3
Riordan, R.D.4
Roobottom, C.A.5
-
12
-
-
79751534189
-
Chest computed tomography using iterative reconstruction vs filtered back projection. Part 1. Evaluation of image noise reduction in 32 patients
-
F. Pontana, J. Pagniez, and T. Flohr Chest computed tomography using iterative reconstruction vs filtered back projection. Part 1. Evaluation of image noise reduction in 32 patients Eur Radiol 21 2011 627 635
-
(2011)
Eur Radiol
, vol.21
, pp. 627-635
-
-
Pontana, F.1
Pagniez, J.2
Flohr, T.3
-
13
-
-
79751526184
-
Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examination in 80 patients
-
F. Pontana, A. Duhamel, and J. Pagniez Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examination in 80 patients Eur Radiol 21 2011 636 643
-
(2011)
Eur Radiol
, vol.21
, pp. 636-643
-
-
Pontana, F.1
Duhamel, A.2
Pagniez, J.3
-
14
-
-
84866057441
-
Effective data-domain noise and streak reduction for X-ray CT
-
M. Kachlriess, M. Rafecas (accessed June 4, 2012)
-
Z Yang, A.A. Zamyatin, and N. Akino Effective data-domain noise and streak reduction for X-ray CT M. Kachlriess, M. Rafecas, 11th International meeting on fully three-dimensional image reconstruction in radiology and nuclear medicine 2011 (Fully 3D Website) (accessed June 4, 2012)
-
(2011)
11th International meeting on fully three-dimensional image reconstruction in radiology and nuclear medicine
-
-
Yang, Z.1
Zamyatin, A.A.2
Akino, N.3
-
15
-
-
84883797719
-
Adaptive-iterative-dose-reduction 3D with multisector-reconstruction method in 320-slice CT may maintain accurate-measurement of the Agatston-calcium-score of severe-calcification even at higher pulsating-beats and low tube-current in vitro
-
N. Funabashi, R. Irie, M. Aiba, R. Morimoto, and T. Kabashima Adaptive-iterative-dose-reduction 3D with multisector-reconstruction method in 320-slice CT may maintain accurate-measurement of the Agatston-calcium-score of severe-calcification even at higher pulsating-beats and low tube-current in vitro Int J Cardiol 168 2013 601 603
-
(2013)
Int J Cardiol
, vol.168
, pp. 601-603
-
-
Funabashi, N.1
Irie, R.2
Aiba, M.3
Morimoto, R.4
Kabashima, T.5
-
16
-
-
84872935444
-
Initial experience with adaptive iterative dose reduction 3D to reduce radiation dose in computed tomographic urography
-
H. Juri, M. Matsuki, Y. Itou, Y. Inada, and G. Nakai Initial experience with adaptive iterative dose reduction 3D to reduce radiation dose in computed tomographic urography J Comput Assist Tomogr 37 2013 52 57
-
(2013)
J Comput Assist Tomogr
, vol.37
, pp. 52-57
-
-
Juri, H.1
Matsuki, M.2
Itou, Y.3
Inada, Y.4
Nakai, G.5
-
17
-
-
84922955845
-
Adaptive iterative dose reduction using three dimensional processing (AIDR3D) improves chest CT image quality and reduces radiation exposure
-
Aug 25
-
T. Yamashiro, T. Miyara, and O. Honda Adaptive iterative dose reduction using three dimensional processing (AIDR3D) improves chest CT image quality and reduces radiation exposure PLoS ONE 9 8 2014 e105735 (Aug 25)
-
(2014)
PLoS ONE
, vol.9
, Issue.8
-
-
Yamashiro, T.1
Miyara, T.2
Honda, O.3
-
18
-
-
84874935300
-
Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
-
M. Katsura, I. Matsuda, and M. Akahane Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique Invest Radiol 48 2013 206212
-
(2013)
Invest Radiol
, vol.48
, pp. 206212
-
-
Katsura, M.1
Matsuda, I.2
Akahane, M.3
-
19
-
-
0004329071
-
International basic safety standards for protection against ionizing radiations and for the safety of radiation sources
-
IAEA Vienna
-
IAEA International basic safety standards for protection against ionizing radiations and for the safety of radiation sources IAEA safety series, no. 115-I 1994 IAEA Vienna
-
(1994)
IAEA safety series, no. 115-I
-
-
IAEA1
-
20
-
-
33846529471
-
National survey of doses from CT in the UK: 2003
-
P.C. Shrimpton, M.C. Hillier, M.A. Lewis, and M. Dunn National survey of doses from CT in the UK: 2003 Br J Radiol 79 948 2006 968 980
-
(2006)
Br J Radiol
, vol.79
, Issue.948
, pp. 968-980
-
-
Shrimpton, P.C.1
Hillier, M.C.2
Lewis, M.A.3
Dunn, M.4
-
21
-
-
0026664983
-
Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method
-
D.D. Dorfman, K.S. Berbaum, and C.E. Metz Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method Invest Radiol 27 1992 723 731
-
(1992)
Invest Radiol
, vol.27
, pp. 723-731
-
-
Dorfman, D.D.1
Berbaum, K.S.2
Metz, C.E.3
-
22
-
-
84863666413
-
Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study
-
Y. Yamada, M. Jinzaki, and Y. Tanami Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study Invest Radiol 47 2012 482 489
-
(2012)
Invest Radiol
, vol.47
, pp. 482-489
-
-
Yamada, Y.1
Jinzaki, M.2
Tanami, Y.3
-
23
-
-
27144449606
-
Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleishner Society
-
H. MacMahon, J.H. Austin, and G. Gamsu Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleishner Society Radiology 237 2005 395 400
-
(2005)
Radiology
, vol.237
, pp. 395-400
-
-
MacMahon, H.1
Austin, J.H.2
Gamsu, G.3
-
24
-
-
0032439673
-
Organ dose calculation in medical X ray examinations by the program PCXMC
-
A. Servomaa, and M. Tapiovaara Organ dose calculation in medical X ray examinations by the program PCXMC Radiat Prot Dosimetry 80 1998 213 219
-
(1998)
Radiat Prot Dosimetry
, vol.80
, pp. 213-219
-
-
Servomaa, A.1
Tapiovaara, M.2
-
25
-
-
40949104442
-
The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103
-
ICRP The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103 Ann ICRP 37 2007 1 332
-
(2007)
Ann ICRP
, vol.37
, pp. 1-332
-
-
ICRP1
-
26
-
-
80054952663
-
Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial
-
F.J. Larke, R.L. Kruger, and C.H. Cagnon Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial AJR Am J Roentgenol 197 2011 1165 1169
-
(2011)
AJR Am J Roentgenol
, vol.197
, pp. 1165-1169
-
-
Larke, F.J.1
Kruger, R.L.2
Cagnon, C.H.3
-
27
-
-
77958569748
-
Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction technique
-
S. Singh, M.K. Kalra, and J. Hsieh Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction technique Radiology 257 2010 373 383
-
(2010)
Radiology
, vol.257
, pp. 373-383
-
-
Singh, S.1
Kalra, M.K.2
Hsieh, J.3
-
28
-
-
77949865226
-
Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
-
P. Prakash, M.K. Kalra, and A.K. Kambadakone Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique Invest Radiol 45 2010 202 210
-
(2010)
Invest Radiol
, vol.45
, pp. 202-210
-
-
Prakash, P.1
Kalra, M.K.2
Kambadakone, A.K.3
-
29
-
-
84878598953
-
Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
-
A. Neroladaki, D. Botsikas, and S. Boudabbous Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations Eur Radiol 23 2013 360 366
-
(2013)
Eur Radiol
, vol.23
, pp. 360-366
-
-
Neroladaki, A.1
Botsikas, D.2
Boudabbous, S.3
-
30
-
-
84871689360
-
Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society
-
D.P. Naidich, A.A. Bankier, and H. MacMahon Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society Radiology 266 2013 304 317
-
(2013)
Radiology
, vol.266
, pp. 304-317
-
-
Naidich, D.P.1
Bankier, A.A.2
MacMahon, H.3
|