메뉴 건너뛰기




Volumn 84, Issue 7, 2015, Pages 1401-1412

Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis

(14)  Nagatani, Yukihiro a   Takahashi, Masashi a   Murata, Kiyoshi a   Ikeda, Mitsuru b   Yamashiro, Tsuneo c   Miyara, Tetsuhiro c,d   Koyama, Hisanobu e   Koyama, Mitsuhiro f   Sato, Yukihisa g,h   Moriya, Hiroshi i   Noma, Satoshi j   Tomiyama, Noriyuki g   Ohno, Yoshiharu e   Murayama, Sadayuki c  


Author keywords

Adaptive iterative dose reduction; Chest; Computed tomography; Image quality; Ultra low dose scanning

Indexed keywords

ADAPTIVE ITERATIVE DOSE REDUCTION; ADULT; AGED; ARTICLE; BODY MASS; CERTIFICATION; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONSENSUS; FEMALE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; INFORMED CONSENT; INSTITUTIONAL REVIEW; JAPAN; LUNG NODULE; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIATION DOSE; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC; THREE DIMENSIONAL IMAGING; THREE DIMENSIONAL PROCESSING; CLINICAL COMPETENCE; CLINICAL TRIAL; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; LUNG; LUNG TUMOR; MIDDLE AGED; OBSERVER VARIATION; PROCEDURES; RADIOGRAPHY; STATISTICS AND NUMERICAL DATA; THORAX RADIOGRAPHY; VERY ELDERLY;

EID: 84930182326     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2015.03.012     Document Type: Article
Times cited : (63)

References (30)
  • 1
    • 79961108629 scopus 로고    scopus 로고
    • Reduced lung-cancer mortality with low-dose computed tomography screening
    • The National Lung Screening Trial Research Team Reduced lung-cancer mortality with low-dose computed tomography screening N Engl J Med 365 2011 395 409
    • (2011) N Engl J Med , vol.365 , pp. 395-409
  • 2
    • 84874688661 scopus 로고    scopus 로고
    • American Cancer Society lung cancer screening guidelines
    • R. Wender, E.T. Fontham, and E. Barrera Jr. American Cancer Society lung cancer screening guidelines CA Cancer J Clin 62 2 2013 107 117
    • (2013) CA Cancer J Clin , vol.62 , Issue.2 , pp. 107-117
    • Wender, R.1    Fontham, E.T.2    Barrera, E.3
  • 3
    • 2142695134 scopus 로고    scopus 로고
    • Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    • D.J. Brenner Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer Radiology 231 2004 440 445
    • (2004) Radiology , vol.231 , pp. 440-445
    • Brenner, D.J.1
  • 4
    • 84862255365 scopus 로고    scopus 로고
    • Benefits and harms of CT screening for lung cancer. A systematic review
    • P.B. Bach, J.N. Mirkin, and T.K. Oliver Benefits and harms of CT screening for lung cancer. A systematic review JAMA 307 2012 2418 2429
    • (2012) JAMA , vol.307 , pp. 2418-2429
    • Bach, P.B.1    Mirkin, J.N.2    Oliver, T.K.3
  • 6
    • 76449091107 scopus 로고    scopus 로고
    • Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience
    • P. Prakash, M.K. Kalra, and S.R. Digumarthy Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience J Comput Assist Tomogr 34 2010 40 45
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 40-45
    • Prakash, P.1    Kalra, M.K.2    Digumarthy, S.R.3
  • 7
    • 62849112550 scopus 로고    scopus 로고
    • Is iterative reconstruction ready for MDCT?
    • J. Xu, M. Mahesh, and B.M. Tsui Is iterative reconstruction ready for MDCT? J Am Coll Radiol 6 2009 274 276
    • (2009) J Am Coll Radiol , vol.6 , pp. 274-276
    • Xu, J.1    Mahesh, M.2    Tsui, B.M.3
  • 8
    • 84876366477 scopus 로고    scopus 로고
    • Reduced-dose low-voltage chest CT angiography with sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection
    • F. Pontana, J. Pagniez, and A. Duhamel Reduced-dose low-voltage chest CT angiography with sinogram-affirmed iterative reconstruction versus standard-dose filtered back projection Radiology 267 2 2013 609 618
    • (2013) Radiology , vol.267 , Issue.2 , pp. 609-618
    • Pontana, F.1    Pagniez, J.2    Duhamel, A.3
  • 9
    • 84878725244 scopus 로고    scopus 로고
    • Iterative reconstruction techniques for computed tomography. Part 1: Technical principles
    • M.J. Willemink, P.A. de Jong, T. Leiner, L.M. de Heer, and R.A. Nievelstein Iterative reconstruction techniques for computed tomography. Part 1: Technical principles Eur Radiol 23 2013 1623 1631
    • (2013) Eur Radiol , vol.23 , pp. 1623-1631
    • Willemink, M.J.1    De Jong, P.A.2    Leiner, T.3    De Heer, L.M.4    Nievelstein, R.A.5
  • 10
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study
    • S. Singh, M.K. Kalra, and M.D. Gilman Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study Radiology 259 2 2011 565 573
    • (2011) Radiology , vol.259 , Issue.2 , pp. 565-573
    • Singh, S.1    Kalra, M.K.2    Gilman, M.D.3
  • 11
    • 84876036668 scopus 로고    scopus 로고
    • Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms
    • V. Vardhanabhuti, R.J. Loader, G.R. Mitchell, R.D. Riordan, and C.A. Roobottom Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms Am J Roentgenol 200 2013 545 552
    • (2013) Am J Roentgenol , vol.200 , pp. 545-552
    • Vardhanabhuti, V.1    Loader, R.J.2    Mitchell, G.R.3    Riordan, R.D.4    Roobottom, C.A.5
  • 12
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection. Part 1. Evaluation of image noise reduction in 32 patients
    • F. Pontana, J. Pagniez, and T. Flohr Chest computed tomography using iterative reconstruction vs filtered back projection. Part 1. Evaluation of image noise reduction in 32 patients Eur Radiol 21 2011 627 635
    • (2011) Eur Radiol , vol.21 , pp. 627-635
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 13
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examination in 80 patients
    • F. Pontana, A. Duhamel, and J. Pagniez Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examination in 80 patients Eur Radiol 21 2011 636 643
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3
  • 15
    • 84883797719 scopus 로고    scopus 로고
    • Adaptive-iterative-dose-reduction 3D with multisector-reconstruction method in 320-slice CT may maintain accurate-measurement of the Agatston-calcium-score of severe-calcification even at higher pulsating-beats and low tube-current in vitro
    • N. Funabashi, R. Irie, M. Aiba, R. Morimoto, and T. Kabashima Adaptive-iterative-dose-reduction 3D with multisector-reconstruction method in 320-slice CT may maintain accurate-measurement of the Agatston-calcium-score of severe-calcification even at higher pulsating-beats and low tube-current in vitro Int J Cardiol 168 2013 601 603
    • (2013) Int J Cardiol , vol.168 , pp. 601-603
    • Funabashi, N.1    Irie, R.2    Aiba, M.3    Morimoto, R.4    Kabashima, T.5
  • 16
    • 84872935444 scopus 로고    scopus 로고
    • Initial experience with adaptive iterative dose reduction 3D to reduce radiation dose in computed tomographic urography
    • H. Juri, M. Matsuki, Y. Itou, Y. Inada, and G. Nakai Initial experience with adaptive iterative dose reduction 3D to reduce radiation dose in computed tomographic urography J Comput Assist Tomogr 37 2013 52 57
    • (2013) J Comput Assist Tomogr , vol.37 , pp. 52-57
    • Juri, H.1    Matsuki, M.2    Itou, Y.3    Inada, Y.4    Nakai, G.5
  • 17
    • 84922955845 scopus 로고    scopus 로고
    • Adaptive iterative dose reduction using three dimensional processing (AIDR3D) improves chest CT image quality and reduces radiation exposure
    • Aug 25
    • T. Yamashiro, T. Miyara, and O. Honda Adaptive iterative dose reduction using three dimensional processing (AIDR3D) improves chest CT image quality and reduces radiation exposure PLoS ONE 9 8 2014 e105735 (Aug 25)
    • (2014) PLoS ONE , vol.9 , Issue.8
    • Yamashiro, T.1    Miyara, T.2    Honda, O.3
  • 18
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • M. Katsura, I. Matsuda, and M. Akahane Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique Invest Radiol 48 2013 206212
    • (2013) Invest Radiol , vol.48 , pp. 206212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 19
    • 0004329071 scopus 로고
    • International basic safety standards for protection against ionizing radiations and for the safety of radiation sources
    • IAEA Vienna
    • IAEA International basic safety standards for protection against ionizing radiations and for the safety of radiation sources IAEA safety series, no. 115-I 1994 IAEA Vienna
    • (1994) IAEA safety series, no. 115-I
    • IAEA1
  • 20
    • 33846529471 scopus 로고    scopus 로고
    • National survey of doses from CT in the UK: 2003
    • P.C. Shrimpton, M.C. Hillier, M.A. Lewis, and M. Dunn National survey of doses from CT in the UK: 2003 Br J Radiol 79 948 2006 968 980
    • (2006) Br J Radiol , vol.79 , Issue.948 , pp. 968-980
    • Shrimpton, P.C.1    Hillier, M.C.2    Lewis, M.A.3    Dunn, M.4
  • 21
    • 0026664983 scopus 로고
    • Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method
    • D.D. Dorfman, K.S. Berbaum, and C.E. Metz Receiver operating characteristic rating analysis: generalization to the population of readers and patients with the jackknife method Invest Radiol 27 1992 723 731
    • (1992) Invest Radiol , vol.27 , pp. 723-731
    • Dorfman, D.D.1    Berbaum, K.S.2    Metz, C.E.3
  • 22
    • 84863666413 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study
    • Y. Yamada, M. Jinzaki, and Y. Tanami Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study Invest Radiol 47 2012 482 489
    • (2012) Invest Radiol , vol.47 , pp. 482-489
    • Yamada, Y.1    Jinzaki, M.2    Tanami, Y.3
  • 23
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleishner Society
    • H. MacMahon, J.H. Austin, and G. Gamsu Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleishner Society Radiology 237 2005 395 400
    • (2005) Radiology , vol.237 , pp. 395-400
    • MacMahon, H.1    Austin, J.H.2    Gamsu, G.3
  • 24
    • 0032439673 scopus 로고    scopus 로고
    • Organ dose calculation in medical X ray examinations by the program PCXMC
    • A. Servomaa, and M. Tapiovaara Organ dose calculation in medical X ray examinations by the program PCXMC Radiat Prot Dosimetry 80 1998 213 219
    • (1998) Radiat Prot Dosimetry , vol.80 , pp. 213-219
    • Servomaa, A.1    Tapiovaara, M.2
  • 25
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103
    • ICRP The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103 Ann ICRP 37 2007 1 332
    • (2007) Ann ICRP , vol.37 , pp. 1-332
    • ICRP1
  • 26
    • 80054952663 scopus 로고    scopus 로고
    • Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial
    • F.J. Larke, R.L. Kruger, and C.H. Cagnon Estimated radiation dose associated with low-dose chest CT of average-size participants in the National Lung Screening Trial AJR Am J Roentgenol 197 2011 1165 1169
    • (2011) AJR Am J Roentgenol , vol.197 , pp. 1165-1169
    • Larke, F.J.1    Kruger, R.L.2    Cagnon, C.H.3
  • 27
    • 77958569748 scopus 로고    scopus 로고
    • Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction technique
    • S. Singh, M.K. Kalra, and J. Hsieh Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction technique Radiology 257 2010 373 383
    • (2010) Radiology , vol.257 , pp. 373-383
    • Singh, S.1    Kalra, M.K.2    Hsieh, J.3
  • 28
    • 77949865226 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
    • P. Prakash, M.K. Kalra, and A.K. Kambadakone Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique Invest Radiol 45 2010 202 210
    • (2010) Invest Radiol , vol.45 , pp. 202-210
    • Prakash, P.1    Kalra, M.K.2    Kambadakone, A.K.3
  • 29
    • 84878598953 scopus 로고    scopus 로고
    • Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
    • A. Neroladaki, D. Botsikas, and S. Boudabbous Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations Eur Radiol 23 2013 360 366
    • (2013) Eur Radiol , vol.23 , pp. 360-366
    • Neroladaki, A.1    Botsikas, D.2    Boudabbous, S.3
  • 30
    • 84871689360 scopus 로고    scopus 로고
    • Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society
    • D.P. Naidich, A.A. Bankier, and H. MacMahon Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society Radiology 266 2013 304 317
    • (2013) Radiology , vol.266 , pp. 304-317
    • Naidich, D.P.1    Bankier, A.A.2    MacMahon, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.