메뉴 건너뛰기




Volumn 37, Issue 1, 2013, Pages 52-57

Initial experience with adaptive iterative dose reduction 3D to reduce radiation dose in computed tomographic urography

Author keywords

CT urography; iterative reconstruction; radiation dose

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; IMAGE RECONSTRUCTION; ITERATIVE METHODS;

EID: 84872935444     PISSN: 03638715     EISSN: 15323145     Source Type: Journal    
DOI: 10.1097/RCT.0b013e3182742c0e     Document Type: Article
Times cited : (18)

References (19)
  • 1
    • 2142696558 scopus 로고    scopus 로고
    • Diagnostic CT Scans: Assessment of Patient, Physician, and Radiologist Awareness of Radiation Dose and Possible Risks
    • DOI 10.1148/radiol.2312030767
    • Lee CI, Haims AH, Monico EP, et al. Diagnostic CT scans: Assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology. 2004;231:393-398. (Pubitemid 38552895)
    • (2004) Radiology , vol.231 , Issue.2 , pp. 393-398
    • Lee, C.I.1    Haims, A.H.2    Monico, E.P.3    Brink, J.A.4    Forman, H.P.5
  • 3
    • 80053922582 scopus 로고    scopus 로고
    • Coronary CT angiography: Image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction techniqueVcomparison with traditional filtered back projection
    • Moscariello A, Takx RAP, Schoepf UJ, et al. Coronary CT angiography: Image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction techniqueVcomparison with traditional filtered back projection. Eur Radiol. 2011;21:2130-2138.
    • (2011) Eur Radiol. , vol.21 , pp. 2130-2138
    • Moscariello, A.1    Takx, R.A.P.2    Schoepf, U.J.3
  • 4
    • 79952812090 scopus 로고    scopus 로고
    • Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction
    • Honda O, Yanagawa M, Inoue A, et al. Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction. Br J Radiol. 2011;84:335-341.
    • (2011) Br J Radiol. , vol.84 , pp. 335-341
    • Honda, O.1    Yanagawa, M.2    Inoue, A.3
  • 5
    • 79952267021 scopus 로고    scopus 로고
    • Impact of adaptive statistical iterative reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: A qualitative and quantitative analysis
    • Cornfeld D, Israel G, Detroy E, et al. Impact of adaptive statistical iterative reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: A qualitative and quantitative analysis. AJR Am J Roentgenol. 2011;196:W336-W340.
    • (2011) AJR Am J Roentgenol. , vol.196
    • Cornfeld, D.1    Israel, G.2    Detroy, E.3
  • 6
    • 77956841482 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 Patients
    • Sagara Y, Hara AK, Pavlicek W, et al. Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 Patients. AJR Am J Roentgenol. 2010;195:713-719.
    • (2010) AJR Am J Roentgenol. , vol.195 , pp. 713-719
    • Sagara, Y.1    Hara, A.K.2    Pavlicek, W.3
  • 7
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
    • Flicek KT, Hara AK, Silva AC, et al. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study. AJR Am J Roentgenol. 2010;195:126-131.
    • (2010) AJR Am J Roentgenol. , vol.195 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3
  • 8
    • 84856605802 scopus 로고    scopus 로고
    • CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector C.T.
    • Garvise A, Osemont B, Lecocq S, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295-301.
    • (2012) Eur Radiol. , vol.22 , pp. 295-301
    • Garvise, A.1    Osemont, B.2    Lecocq, S.3
  • 9
    • 39149113136 scopus 로고    scopus 로고
    • CT urography: Definition, indications and techniques A guideline for clinical practice
    • Van Der Molen AJ, Cowan NC, Mueller-Lisse CCA, et al. CT urography: definition, indications and techniques. A guideline for clinical practice. Eur Radiol. 2008;18:4-17.
    • (2008) Eur Radiol. , vol.18 , pp. 4-17
    • Van Der Molen, A.J.1    Cowan, N.C.2    Mueller-Lisse, C.C.A.3
  • 10
    • 34548538709 scopus 로고    scopus 로고
    • Multi-detector CT urography: A one-stop renal and urinary tract imaging modality
    • DOI 10.1007/s00261-007-9185-5
    • Dillman JR, Caoili EM, Cohan RH. Multi-detector CT urography: A one-stop renal and urinary tract imaging modality. Abdom Imaging. 2007;32:519-529. (Pubitemid 47383876)
    • (2007) Abdominal Imaging , vol.32 , Issue.4 , pp. 519-529
    • Dillman, J.R.1    Caoili, E.M.2    Cohan, R.H.3
  • 11
    • 79959576156 scopus 로고    scopus 로고
    • Comparison of CTurography and excretory urography in the detection and localization of urothelial carcinoma of the upper urinary tract
    • Jinzaki M, Matsumoto K, Kikuchi E, et al. Comparison of CTurography and excretory urography in the detection and localization of urothelial carcinoma of the upper urinary tract. AJR Am J Roentgenol. 2011;196:1102-1109.
    • (2011) AJR Am J Roentgenol. , vol.196 , pp. 1102-1109
    • Jinzaki, M.1    Matsumoto, K.2    Kikuchi, E.3
  • 13
    • 2942755835 scopus 로고    scopus 로고
    • Patient radiation dose at CT urography and conventional urography
    • DOI 10.1148/radiol.2321030222
    • Nawfel RD, Judy PF, Schleipman AR, et al. Patient radiation dose at CT urography and conventional urography. Radiology. 2004;232:126-132. (Pubitemid 38787827)
    • (2004) Radiology , vol.232 , Issue.1 , pp. 126-132
    • Nawfel, R.D.1    Judy, P.F.2    Schleipman, A.R.3    Silverman, S.G.4
  • 14
    • 33947688154 scopus 로고    scopus 로고
    • Comparison of effective radiation doses in patients undergoing unenhanced MDCT and excretory urography for acute flank pain
    • DOI 10.2214/AJR.06.0676
    • Eikefjord EN, Thorsen F, Rorvik J. Comparison of effective radiation doses in patients undergoing unenhanced MDCT and excretory urography for acute flank pain. AJR Am J Roentgenol. 2007;188:934-939. (Pubitemid 46496922)
    • (2007) American Journal of Roentgenology , vol.188 , Issue.4 , pp. 934-939
    • Eikefjord, E.N.1    Thorsen, F.2    Rorvik, J.3
  • 15
    • 63849281602 scopus 로고    scopus 로고
    • Spatial resolution and radiation dose of a 64-MDCT scanner compared with published CT urography protocols
    • Vrtiska TJ, Hartman RP, Kofler JM, et al. Spatial resolution and radiation dose of a 64-MDCT scanner compared with published CT urography protocols. AJR Am J Roentgenol. 2009;291:941-948.
    • (2009) AJR Am J Roentgenol. , vol.291 , pp. 941-948
    • Vrtiska, T.J.1    Hartman, R.P.2    Kofler, J.M.3
  • 17
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner DJ, Hall EJ. Computed tomography: An increasing source of radiation exposure. N Engl J Med. 2007;357:2277-2284. (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 18
    • 73149110471 scopus 로고    scopus 로고
    • Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer
    • Smith-Brindman R, lipson J, Marcus R, et al. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009;169:2078-2086.
    • (2009) Arch Intern Med. , vol.169 , pp. 2078-2086
    • Smith-Brindman, R.1    Lipson, J.2    Marcus, R.3
  • 19
    • 69949109658 scopus 로고    scopus 로고
    • Low-Dose MDCT Urography: Feasibility study of low-tube-voltage technique and adaptive noise reduction filter
    • Yanaga Y, Awai K, Funama Y, et al. Low-Dose MDCT Urography: feasibility study of low-tube-voltage technique and adaptive noise reduction filter. AJR Am J Roentgenol. 2009;193:220-229.
    • (2009) AJR Am J Roentgenol. , vol.193 , pp. 220-229
    • Yanaga, Y.1    Awai, K.2    Funama, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.