메뉴 건너뛰기




Volumn 40, Issue 5, 2015, Pages 1183-1189

Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction

Author keywords

Adaptive statistical iterative reconstruction; Computed tomography; CT colonography; Iterative reconstruction; Model based iterative reconstruction; Reduced dose

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; ARTIFACT REDUCTION; BODY MASS; CLINICAL ARTICLE; COMPUTED TOMOGRAPHIC COLONOGRAPHY; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; MALE; MODEL BASED ITERATIVE RECONSTRUCTION; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE REDUCTION; THREE DIMENSIONAL IMAGING; COLON TUMOR; IMAGE PROCESSING; MASS SCREENING; MIDDLE AGED; PROCEDURES; RADIOGRAPHY; VERY ELDERLY;

EID: 84930179404     PISSN: 09428925     EISSN: 14320509     Source Type: Journal    
DOI: 10.1007/s00261-014-0271-1     Document Type: Article
Times cited : (11)

References (18)
  • 1
    • 79955025083 scopus 로고    scopus 로고
    • Colorectal cancer: CT colonography and colonoscopy for detection: systematic review and meta-analysis
    • PID: 21415247
    • Pickhardt PJ, Hassan C, Halligan S, Marmo R (2011) Colorectal cancer: CT colonography and colonoscopy for detection: systematic review and meta-analysis. Radiology 259(2):393–405
    • (2011) Radiology , vol.259 , Issue.2 , pp. 393-405
    • Pickhardt, P.J.1    Hassan, C.2    Halligan, S.3    Marmo, R.4
  • 2
    • 67649226043 scopus 로고    scopus 로고
    • Diagnostic accuracy of computed tomographic colonography for the detection of advanced neoplasia in individuals at increased risk of colorectal cancer
    • COI: 1:CAS:528:DC%2BD1MXnsFWgurw%3D, PID: 19531785
    • Regge D, Laudi C, Galatola G, et al. (2009) Diagnostic accuracy of computed tomographic colonography for the detection of advanced neoplasia in individuals at increased risk of colorectal cancer. JAMA 301(23):2453–2461
    • (2009) JAMA , vol.301 , Issue.23 , pp. 2453-2461
    • Regge, D.1    Laudi, C.2    Galatola, G.3    Della Monica, P.4    Bonelli, L.5    Angelelli, G.6
  • 5
    • 84863702578 scopus 로고    scopus 로고
    • Screening computed tomography colonography with 256-slice scanning: should patient radiation burden and associated cancer risk constitute a major concern?
    • PID: 22766908
    • Perisinakis K, Seimenis I, Tzedakis A, et al. (2012) Screening computed tomography colonography with 256-slice scanning: should patient radiation burden and associated cancer risk constitute a major concern? Invest Radiol. 47(8):451–456
    • (2012) Invest Radiol. , vol.47 , Issue.8 , pp. 451-456
    • Perisinakis, K.1    Seimenis, I.2    Tzedakis, A.3    Papadakis, A.E.4    Kourinou, K.M.5    Damilakis, J.6
  • 6
    • 22344437374 scopus 로고    scopus 로고
    • Mass screening with CT colonography: should the radiation exposure be of concern?
    • PID: 16012958
    • Brenner DJ, Georgsson MA (2005) Mass screening with CT colonography: should the radiation exposure be of concern? Gastroenterology 129(1):328–337
    • (2005) Gastroenterology , vol.129 , Issue.1 , pp. 328-337
    • Brenner, D.J.1    Georgsson, M.A.2
  • 11
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study
    • PID: 20566805
    • Flicek KT, Hara AK, Silva AC, et al. (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 195(1):126–131
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.1 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 12
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • PID: 18072519
    • Thibault JB, Sauer KD, Bouman CA, Hsieh J (2007) A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 34(11):4526–4544
    • (2007) Med Phys , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 13
    • 52249108133 scopus 로고    scopus 로고
    • Accuracy of CT colonography for detection of large adenomas and cancers
    • COI: 1:CAS:528:DC%2BD1cXhtFGjt7fI, PID: 18799557, Erratum in: N Engl J Med. 2008;359(26):2853
    • Johnson CD, Chen MH, Toledano AY, et al. (2008) Accuracy of CT colonography for detection of large adenomas and cancers. N Engl J Med. 359(12):1207–1217 (Erratum in: N Engl J Med. 2008;359(26):2853)
    • (2008) N Engl J Med. , vol.359 , Issue.12 , pp. 1207-1217
    • Johnson, C.D.1    Chen, M.H.2    Toledano, A.Y.3    Heiken, J.P.4    Dachman, A.5    Kuo, M.D.6
  • 14
    • 77950604342 scopus 로고    scopus 로고
    • Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning
    • PID: 20308486, Erratum in: AJR Am J Roentgenol. 2010;194(5):1404
    • Christner JA, Kofler JM, McCollough CH (2010) Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol. 194(4):881–889 (Erratum in: AJR Am J Roentgenol. 2010;194(5):1404)
    • (2010) AJR Am J Roentgenol. , vol.194 , Issue.4 , pp. 881-889
    • Christner, J.A.1    Kofler, J.M.2    McCollough, C.H.3
  • 15
    • 84870903463 scopus 로고    scopus 로고
    • Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging
    • PID: 23169718
    • Pickhardt PJ, Lubner MG, Kim DH, et al. (2012) Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging. AJR Am J Roentgenol. 199(6):1266–1274
    • (2012) AJR Am J Roentgenol. , vol.199 , Issue.6 , pp. 1266-1274
    • Pickhardt, P.J.1    Lubner, M.G.2    Kim, D.H.3    Tang, J.4    Ruma, J.A.5    del Rio, A.M.6
  • 16
    • 84866711802 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses
    • PID: 22992612
    • Yoon MA, Kim SH, Lee JM, et al. (2012) Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses. J Comput Assist Tomogr. 36(5):596–601
    • (2012) J Comput Assist Tomogr. , vol.36 , Issue.5 , pp. 596-601
    • Yoon, M.A.1    Kim, S.H.2    Lee, J.M.3    Woo, H.S.4    Lee, E.S.5    Ahn, S.J.6
  • 17
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • PID: 23344517
    • Katsura M, Matsuda I, Akahane M, et al. (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Invest Radiol. 48(4):206–212
    • (2013) Invest Radiol. , vol.48 , Issue.4 , pp. 206-212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3    Yasaka, K.4    Hanaoka, S.5    Akai, H.6
  • 18
    • 84874301989 scopus 로고    scopus 로고
    • Reducing radiation dose at CT colonography: decreasing tube voltage to 100 kVp
    • PID: 23264348, Epub 2012 Dec 21
    • Chang KJ, Caovan DB, Grand DJ, Huda W, Mayo-Smith WW (2013) Reducing radiation dose at CT colonography: decreasing tube voltage to 100 kVp. Radiology. 266(3):791–800 (Epub 2012 Dec 21)
    • (2013) Radiology. , vol.266 , Issue.3 , pp. 791-800
    • Chang, K.J.1    Caovan, D.B.2    Grand, D.J.3    Huda, W.4    Mayo-Smith, W.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.