-
1
-
-
52249108133
-
Accuracy of CT colonography for detection of large adenomas and cancers
-
Johnson CD, Chen MH, Toledano AY, et al. Accuracy of CT colonography for detection of large adenomas and cancers. N Engl J Med 2008;359(12): 1207-1217.
-
(2008)
N Engl J Med
, vol.359
, Issue.12
, pp. 1207-1217
-
-
Johnson, C.D.1
Chen, M.H.2
Toledano, A.Y.3
-
2
-
-
79955025083
-
Colorectal cancer: CT colonography and colonoscopy for detection - Systematic review and meta-analysis
-
Pickhardt PJ, Hassan C, Halligan S, Marmo R. Colorectal cancer: CT colonography and colonoscopy for detection - systematic review and meta-analysis. Radiology 2011;259(2): 393-405.
-
(2011)
Radiology
, vol.259
, Issue.2
, pp. 393-405
-
-
Pickhardt, P.J.1
Hassan, C.2
Halligan, S.3
Marmo, R.4
-
3
-
-
42949177399
-
Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: A joint guideline from the American Cancer Society, the US Multi- Society Task Force on Colorectal Cancer, and the American College of Radiology
-
Levin B, Lieberman DA, McFarland B, et al. Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi- Society Task Force on Colorectal Cancer, and the American College of Radiology. CA Cancer J Clin 2008;58(3): 130-160.
-
(2008)
CA Cancer J Clin
, vol.58
, Issue.3
, pp. 130-160
-
-
Levin, B.1
Lieberman, D.A.2
McFarland, B.3
-
4
-
-
22344437374
-
Mass screening with CT colonography: Should the radiation exposure be of concern?
-
Brenner DJ, Georgsson MA. Mass screening with CT colonography: should the radiation exposure be of concern? Gastroenterology 2005;129(1): 328-337.
-
(2005)
Gastroenterology
, vol.129
, Issue.1
, pp. 328-337
-
-
Brenner, D.J.1
Georgsson, M.A.2
-
5
-
-
36549007486
-
Computed tomography: An increasing source of radiation exposure
-
Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007;357(22): 2277-2284.
-
(2007)
N Engl J Med
, vol.357
, Issue.22
, pp. 2277-2284
-
-
Brenner, D.J.1
Hall, E.J.2
-
8
-
-
58149240065
-
Mortality and cancer incidence following occupational radiation exposure: Third analysis of the National Registry for Radiation Workers
-
Muirhead CR, O'Hagan JA, Haylock RG, et al. Mortality and cancer incidence following occupational radiation exposure: third analysis of the National Registry for Radiation Workers. Br J Cancer 2009;100(1): 206-212.
-
(2009)
Br J Cancer
, vol.100
, Issue.1
, pp. 206-212
-
-
Muirhead, C.R.1
O'Hagan, J.A.2
Haylock, R.G.3
-
9
-
-
0036319709
-
Multi-slice CT colonography in low-dose technique: Preliminary results
-
Cohnen M, Vogt C, Aurich V, Beck A, Häussinger D, Mödder U. Multi-slice CT colonography in low-dose technique: preliminary results. Rofo 2002;174(7): 835-838.
-
(2002)
Rofo
, vol.174
, Issue.7
, pp. 835-838
-
-
Cohnen, M.1
Vogt, C.2
Aurich, V.3
Beck, A.4
Häussinger, D.5
Mödder, U.6
-
10
-
-
0038756656
-
Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: Preliminary experience
-
Iannaccone R, Laghi A, Catalano C, Mangiapane F, Piacentini F, Passariello R. Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience. Eur Radiol 2003;13(6): 1297-1302.
-
(2003)
Eur Radiol
, vol.13
, Issue.6
, pp. 1297-1302
-
-
Iannaccone, R.1
Laghi, A.2
Catalano, C.3
Mangiapane, F.4
Piacentini, F.5
Passariello, R.6
-
11
-
-
0032742081
-
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
-
Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. Med Phys 1999;26(11): 2248-2253.
-
(1999)
Med Phys
, vol.26
, Issue.11
, pp. 2248-2253
-
-
Kalender, W.A.1
Wolf, H.2
Suess, C.3
-
12
-
-
4644221703
-
Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients
-
Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of Z-axis modulation technique performed in 153 patients. Radiology 2004;233(1): 241-249.
-
(2004)
Radiology
, vol.233
, Issue.1
, pp. 241-249
-
-
Kalra, M.K.1
Maher, M.M.2
Kamath, R.S.3
-
13
-
-
33645830709
-
Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
-
Rizzo S, Kalra M, Schmidt B, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. AJR Am J Roentgenol 2006;186(3): 673-679.
-
(2006)
AJR Am J Roentgenol
, vol.186
, Issue.3
, pp. 673-679
-
-
Rizzo, S.1
Kalra, M.2
Schmidt, B.3
-
14
-
-
0041343248
-
Dose reduction in multidetector CT using attenuation- based online tube current modulation
-
Tack D, De Maertelaer V, Gevenois PA. Dose reduction in multidetector CT using attenuation- based online tube current modulation. AJR Am J Roentgenol 2003;181(2): 331-334.
-
(2003)
AJR Am J Roentgenol
, vol.181
, Issue.2
, pp. 331-334
-
-
Tack, D.1
De Maertelaer, V.2
Gevenois, P.A.3
-
15
-
-
33748461416
-
Dose reduction and image quality in MDCT colonography using tube current modulation
-
Graser A, Wintersperger BJ, Suess C, Reiser MF, Becker CR. Dose reduction and image quality in MDCT colonography using tube current modulation. AJR Am J Roentgenol 2006;187(3): 695-701.
-
(2006)
AJR Am J Roentgenol
, vol.187
, Issue.3
, pp. 695-701
-
-
Graser, A.1
Wintersperger, B.J.2
Suess, C.3
Reiser, M.F.4
Becker, C.R.5
-
16
-
-
27744559376
-
Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: Phantom study
-
Funama Y, Awai K, Nakayama Y, et al. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 2005;237(3): 905-910.
-
(2005)
Radiology
, vol.237
, Issue.3
, pp. 905-910
-
-
Funama, Y.1
Awai, K.2
Nakayama, Y.3
-
18
-
-
77955894079
-
Relationship between radiographic techniques (kilovolt and milliampere-second) and CTDI(VOL)
-
Elojeimy S, Tipnis S, Huda W. Relationship between radiographic techniques (kilovolt and milliampere-second) and CTDI(VOL). Radiat Prot Dosimetry 2010;141(1): 43-49.
-
(2010)
Radiat Prot Dosimetry
, vol.141
, Issue.1
, pp. 43-49
-
-
Elojeimy, S.1
Tipnis, S.2
Huda, W.3
-
19
-
-
12544253582
-
Aorto-iliac multidetector-row CT angiography with low kV settings: Improved vessel enhancement and simultaneous reduction of radiation dose
-
Wintersperger B, Jakobs T, Herzog P, et al. Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005;15(2): 334-341.
-
(2005)
Eur Radiol
, vol.15
, Issue.2
, pp. 334-341
-
-
Wintersperger, B.1
Jakobs, T.2
Herzog, P.3
-
20
-
-
35348977748
-
Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study
-
Heyer CM, Mohr PS, Lemburg SP, Peters SA, Nicolas V. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 2007;245(2): 577-583.
-
(2007)
Radiology
, vol.245
, Issue.2
, pp. 577-583
-
-
Heyer, C.M.1
Mohr, P.S.2
Lemburg, S.P.3
Peters, S.A.4
Nicolas, V.5
-
21
-
-
0017665285
-
A quantitative theory of the Hounsfield unit and its application to dual energy scanning
-
Brooks RA. A quantitative theory of the Hounsfield unit and its application to dual energy scanning. J Comput Assist Tomogr 1977;1(4): 487-493.
-
(1977)
J Comput Assist Tomogr
, vol.1
, Issue.4
, pp. 487-493
-
-
Brooks, R.A.1
-
22
-
-
0033730930
-
Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow
-
Wintermark M, Maeder P, Verdun FR, et al. Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 2000;21(10): 1881-1884.
-
(2000)
AJNR Am J Neuroradiol
, vol.21
, Issue.10
, pp. 1881-1884
-
-
Wintermark, M.1
Maeder, P.2
Verdun, F.R.3
-
23
-
-
1642389455
-
Low-kilovoltage multidetector row chest CT in adults: Feasibility and effect on image quality and iodine dose
-
Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF. Low-kilovoltage multidetector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 2004;231(1): 169-174.
-
(2004)
Radiology
, vol.231
, Issue.1
, pp. 169-174
-
-
Sigal-Cinqualbre, A.B.1
Hennequin, R.2
Abada, H.T.3
Chen, X.4
Paul, J.F.5
-
24
-
-
33750299544
-
Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography
-
Nakayama Y, Awai K, Funama Y, et al. Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 2006;187(5): W490-W497.
-
(2006)
AJR Am J Roentgenol
, vol.187
, Issue.5
-
-
Nakayama, Y.1
Awai, K.2
Funama, Y.3
-
25
-
-
79551524344
-
Fluid tagging for CT colonography: Effectiveness of a 2-hour iodinated oral preparation after incomplete optical colonoscopy
-
Chang KJ, Rekhi SS Jr, Anderson SW, Soto JA. Fluid tagging for CT colonography: effectiveness of a 2-hour iodinated oral preparation after incomplete optical colonoscopy. J Comput Assist Tomogr 2011;35(1): 91-95.
-
(2011)
J Comput Assist Tomogr
, vol.35
, Issue.1
, pp. 91-95
-
-
Chang, K.J.1
Rekhi Jr., S.S.2
Anderson, S.W.3
Soto, J.A.4
-
26
-
-
78649740074
-
Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control
-
Israel GM, Cicchiello L, Brink J, Huda W. Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control. AJR Am J Roentgenol 2010;195(6): 1342-1346.
-
(2010)
AJR Am J Roentgenol
, vol.195
, Issue.6
, pp. 1342-1346
-
-
Israel, G.M.1
Cicchiello, L.2
Brink, J.3
Huda, W.4
-
27
-
-
70449135326
-
Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning
-
Gudjonsdottir J, Svensson JR, Campling S, Brennan PC, Jonsdottir B. Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning. Acta Radiol 2009;50(9): 1035-1041.
-
(2009)
Acta Radiol
, vol.50
, Issue.9
, pp. 1035-1041
-
-
Gudjonsdottir, J.1
Svensson, J.R.2
Campling, S.3
Brennan, P.C.4
Jonsdottir, B.5
-
28
-
-
33846503259
-
Automatic patient centering for MDCT: Effect on radiation dose
-
Li J, Udayasankar UK, Toth TL, Seamans J, Small WC, Kalra MK. Automatic patient centering for MDCT: effect on radiation dose. AJR Am J Roentgenol 2007;188(2): 547-552.
-
(2007)
AJR Am J Roentgenol
, vol.188
, Issue.2
, pp. 547-552
-
-
Li, J.1
Udayasankar, U.K.2
Toth, T.L.3
Seamans, J.4
Small, W.C.5
Kalra, M.K.6
-
29
-
-
63849287809
-
Misoperation of CT automatic tube current modulation systems with inappropriate patient centering: Phantom studies
-
Matsubara K, Koshida K, Ichikawa K, et al. Misoperation of CT automatic tube current modulation systems with inappropriate patient centering: phantom studies. AJR Am J Roentgenol 2009;192(4): 862-865.
-
(2009)
AJR Am J Roentgenol
, vol.192
, Issue.4
, pp. 862-865
-
-
Matsubara, K.1
Koshida, K.2
Ichikawa, K.3
-
30
-
-
77952310162
-
Evaluation of image quality and lesion perception by human readers on 3D CT colonography: Comparison of stan- dard and low radiation dose
-
Fisichella VA, Båth M, Allansdotter Johnsson A, et al. Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of stan- dard and low radiation dose. Eur Radiol 2010;20(3): 630-639.
-
(2010)
Eur Radiol
, vol.20
, Issue.3
, pp. 630-639
-
-
Fisichella, V.A.1
Båth, M.2
Allansdotter Johnsson, A.3
-
31
-
-
36348949103
-
Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study
-
Florie J, van Gelder RE, Schutter MP, et al. Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study. Eur Radiol 2007;17(12): 3112-3122.
-
(2007)
Eur Radiol
, vol.17
, Issue.12
, pp. 3112-3122
-
-
Florie, J.1
Van Gelder, R.E.2
Schutter, M.P.3
-
32
-
-
3242815478
-
CT colonography: Feasibility of substantial dose reduction - Comparison of medium to very low doses in identical patients
-
van Gelder RE, Venema HW, Florie J, et al. CT colonography: feasibility of substantial dose reduction - comparison of medium to very low doses in identical patients. Radiology 2004;232(2): 611-620.
-
(2004)
Radiology
, vol.232
, Issue.2
, pp. 611-620
-
-
Van Gelder, R.E.1
Venema, H.W.2
Florie, J.3
-
33
-
-
0036085139
-
CT colonography at different radiation dose levels: Feasibility of dose reduction
-
van Gelder RE, Venema HW, Serlie IW, et al. CT colonography at different radiation dose levels: feasibility of dose reduction. Radiology 2002;224(1): 25-33.
-
(2002)
Radiology
, vol.224
, Issue.1
, pp. 25-33
-
-
Van Gelder, R.E.1
Venema, H.W.2
Serlie, I.W.3
-
34
-
-
79960546944
-
Low-kilovoltage, high-tube-current MDCT of liver in thin adults: Pilot study evaluating radiation dose, image quality, and display settings
-
Nakaura T, Awai K, Oda S, et al. Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings. AJR Am J Roentgenol 2011;196(6): 1332-1338.
-
(2011)
AJR Am J Roentgenol
, vol.196
, Issue.6
, pp. 1332-1338
-
-
Nakaura, T.1
Awai, K.2
Oda, S.3
-
35
-
-
79551514778
-
A lowkilovolt (peak) high-tube current technique improves venous enhancement and reduces the radiation dose at indirect multidetectorrow CT venography: Initial experience
-
Nakaura T, Awai K, Oda S, et al. A lowkilovolt (peak) high-tube current technique improves venous enhancement and reduces the radiation dose at indirect multidetectorrow CT venography: initial experience. J Comput Assist Tomogr 2011;35(1): 141-147.
-
(2011)
J Comput Assist Tomogr
, vol.35
, Issue.1
, pp. 141-147
-
-
Nakaura, T.1
Awai, K.2
Oda, S.3
-
36
-
-
27744501240
-
Abdominal CT with low tube voltage: Preliminary observations about radiation dose, contrast enhancement, image quality, and noise
-
Nakayama Y, Awai K, Funama Y, et al. Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 2005;237(3): 945-951.
-
(2005)
Radiology
, vol.237
, Issue.3
, pp. 945-951
-
-
Nakayama, Y.1
Awai, K.2
Funama, Y.3
-
37
-
-
79960489253
-
Hepatocellular carcinoma in patients weighing 70 kg or less: Initial trial of compactbolus dynamic CT with low-dose contrast material at 80 kVp
-
Yanaga Y, Awai K, Nakaura T, et al. Hepatocellular carcinoma in patients weighing 70 kg or less: initial trial of compactbolus dynamic CT with low-dose contrast material at 80 kVp. AJR Am J Roentgenol 2011;196(6): 1324-1331.
-
(2011)
AJR Am J Roentgenol
, vol.196
, Issue.6
, pp. 1324-1331
-
-
Yanaga, Y.1
Awai, K.2
Nakaura, T.3
-
38
-
-
0033735138
-
Technique factors and image quality as functions of patient weight at abdominal C.T
-
Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000;217(2): 430-435.
-
(2000)
Radiology
, vol.217
, Issue.2
, pp. 430-435
-
-
Huda, W.1
Scalzetti, E.M.2
Levin, G.3
-
39
-
-
78649653575
-
Appropriate patient selection at abdominal dual-energy CT using 80 kV: Relationship between patient size, image noise, and image quality
-
Guimarães LS, Fletcher JG, Harmsen WS, et al. Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality. Radiology 2010;257(3): 732-742.
-
(2010)
Radiology
, vol.257
, Issue.3
, pp. 732-742
-
-
Guimarães, L.S.1
Fletcher, J.G.2
Harmsen, W.S.3
-
40
-
-
35649025312
-
A three-dimensional statistical approach to improved image quality for multislice helical C.T
-
Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 2007;34(11): 4526-4544.
-
(2007)
Med Phys
, vol.34
, Issue.11
, pp. 4526-4544
-
-
Thibault, J.B.1
Sauer, K.D.2
Bouman, C.A.3
Hsieh, J.4
-
41
-
-
69949096664
-
Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
-
Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 2009;193(3): 764-771.
-
(2009)
AJR Am J Roentgenol
, vol.193
, Issue.3
, pp. 764-771
-
-
Hara, A.K.1
Paden, R.G.2
Silva, A.C.3
Kujak, J.L.4
Lawder, H.J.5
Pavlicek, W.6
-
42
-
-
77954708865
-
Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
-
Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 2010;195(1): 126-131.
-
(2010)
AJR Am J Roentgenol
, vol.195
, Issue.1
, pp. 126-131
-
-
Flicek, K.T.1
Hara, A.K.2
Silva, A.C.3
Wu, Q.4
Peter, M.B.5
Johnson, C.D.6
|