메뉴 건너뛰기




Volumn 50, Issue 6, 2015, Pages 367-375

Free-breathing liver perfusion imaging using 3-dimensional through-time spiral generalized autocalibrating partially parallel acquisition acceleration

Author keywords

DCE MRI; liver perfusion; through time spiral GRAPPA

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; ARTIFACT; BODY MOVEMENT; BREATH HOLDING; CASE REPORT; COMPARTMENT MODEL; CONTRAST ENHANCEMENT; CONTROLLED STUDY; FEMALE; HISTIOCYTOMA; HUMAN; IMAGE QUALITY; LIVER; LIVER PERFUSION; LIVER SCINTISCANNING; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; THICKNESS; THREE DIMENSIONAL IMAGING; BREATHING; IMAGE ENHANCEMENT; IMAGE PROCESSING; LIVER DISEASES; PATHOLOGY; PROCEDURES; PROSPECTIVE STUDY; REPRODUCIBILITY; YOUNG ADULT;

EID: 84929313745     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0000000000000135     Document Type: Article
Times cited : (27)

References (32)
  • 1
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    • Hanley J, Debois MM, Mah D, et al. Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. Int J Radiat Oncol Biol Phys. 1999;45:603-611.
    • (1999) Int J Radiat Oncol Biol Phys. , vol.45 , pp. 603-611
    • Hanley, J.1    Debois, M.M.2    Mah, D.3
  • 2
    • 84890558622 scopus 로고    scopus 로고
    • Clinical evaluation of CAIPIRINHA: Comparison against a GRAPPA standard
    • Wright KL, Harrell MW, Jesberger JA, et al. Clinical evaluation of CAIPIRINHA: Comparison against a GRAPPA standard. J Magn Reson Imaging. 2014;39: 189-194.
    • (2014) J Magn Reson Imaging. , vol.39 , pp. 189-194
    • Wright, K.L.1    Harrell, M.W.2    Jesberger, J.A.3
  • 3
    • 84879958003 scopus 로고    scopus 로고
    • Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: A comparison with generalized autocalibrating partially parallel acquisitions parallel imaging
    • Riffel P, Attenberger UI, Kannengiesser S, et al. Highly accelerated T1-weighted abdominal imaging using 2-dimensional controlled aliasing in parallel imaging results in higher acceleration: a comparison with generalized autocalibrating partially parallel acquisitions parallel imaging. Invest Radiol. 2013;48:554-561.
    • (2013) Invest Radiol. , vol.48 , pp. 554-561
    • Riffel, P.1    Attenberger, U.I.2    Kannengiesser, S.3
  • 4
    • 84880315434 scopus 로고    scopus 로고
    • CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): A new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution
    • Michaely HJ, Morelli JN, Budjan J, et al. CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE): a new technique for fast time-resolved dynamic 3-dimensional imaging of the abdomen with high spatial resolution. Invest Radiol. 2013;48:590-597.
    • (2013) Invest Radiol. , vol.48 , pp. 590-597
    • Michaely, H.J.1    Morelli, J.N.2    Budjan, J.3
  • 5
    • 84894091067 scopus 로고    scopus 로고
    • Usefulness of controlled aliasing in parallel imaging results in higher acceleration in gadoxetic acid-enhanced liver magnetic resonance imaging to clarify the hepatic arterial phase
    • Park YS, Lee CH, Kim IS, et al. Usefulness of controlled aliasing in parallel imaging results in higher acceleration in gadoxetic acid-enhanced liver magnetic resonance imaging to clarify the hepatic arterial phase. Invest Radiol. 2014;49: 183-188.
    • (2014) Invest Radiol. , vol.49 , pp. 183-188
    • Park, Y.S.1    Lee, C.H.2    Kim, I.S.3
  • 6
    • 13844272509 scopus 로고    scopus 로고
    • Perfusion imaging of the liver: Current challenges and future goals
    • Pandharipande PV, Krinsky GA, Rusinek H, et al. Perfusion imaging of the liver: current challenges and future goals. Radiology. 2005;234:661-673.
    • (2005) Radiology. , vol.234 , pp. 661-673
    • Pandharipande, P.V.1    Krinsky, G.A.2    Rusinek, H.3
  • 7
    • 40949099048 scopus 로고    scopus 로고
    • Advanced liver fibrosis: Diagnosis with 3D whole-liver perfusion MR imaging -initial experience
    • Hagiwara M, Rusinek H, Lee VS, et al. Advanced liver fibrosis: diagnosis with 3D whole-liver perfusion MR imaging -initial experience. Radiology. 2008; 246:926-934.
    • (2008) Radiology. , vol.246 , pp. 926-934
    • Hagiwara, M.1    Rusinek, H.2    Lee, V.S.3
  • 8
    • 53749095872 scopus 로고    scopus 로고
    • Hepatic metastases: In vivo assessment of perfusion parameters at dynamic contrast-enhanced MR imaging with dual-input two-compartment tracer kinetics model
    • Koh TS, Thng CH, Lee PS, et al. Hepatic metastases: in vivo assessment of perfusion parameters at dynamic contrast-enhanced MR imaging with dual-input two-compartment tracer kinetics model. Radiology. 2008;249:307-320.
    • (2008) Radiology. , vol.249 , pp. 307-320
    • Koh, T.S.1    Thng, C.H.2    Lee, P.S.3
  • 9
    • 79251626883 scopus 로고    scopus 로고
    • Technical aspects of MR perfusion
    • Sourbron S. Technical aspects of MR perfusion. Eur J Radiol. 2010;76:304-313.
    • (2010) Eur J Radiol. , vol.76 , pp. 304-313
    • Sourbron, S.1
  • 10
    • 84861323740 scopus 로고    scopus 로고
    • Neuroendocrine tumor liver metastases: Use of dynamic contrast-enhanced MR imaging to monitor and predict radiolabeled octreotide therapy response
    • Miyazaki K, Orton MR, Davidson RL, et al. Neuroendocrine tumor liver metastases: use of dynamic contrast-enhanced MR imaging to monitor and predict radiolabeled octreotide therapy response. Radiology. 2012;263:139-148.
    • (2012) Radiology. , vol.263 , pp. 139-148
    • Miyazaki, K.1    Orton, M.R.2    Davidson, R.L.3
  • 11
    • 85027934963 scopus 로고    scopus 로고
    • Golden-angle radial sparse parallelMRI: Combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI
    • Feng L, Grimm R, Block KT, et al. Golden-angle radial sparse parallelMRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI. Magn Reson Med. 2014; 72:707-717.
    • (2014) Magn Reson Med. , vol.72 , pp. 707-717
    • Feng, L.1    Grimm, R.2    Block, K.T.3
  • 12
    • 84871607756 scopus 로고    scopus 로고
    • Free-breathing contrast-enhanced multiphaseMRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling
    • Chandarana H, Feng L, Block TK, et al. Free-breathing contrast-enhanced multiphaseMRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling. Invest Radiol. 2013;48:10-16.
    • (2013) Invest Radiol. , vol.48 , pp. 10-16
    • Chandarana, H.1    Feng, L.2    Block, T.K.3
  • 13
    • 81355147810 scopus 로고    scopus 로고
    • Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA
    • Seiberlich N, Lee G, Ehses P, et al. Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA. Magn Reson Med. 2011;66:1682-1688.
    • (2011) Magn Reson Med. , vol.66 , pp. 1682-1688
    • Seiberlich, N.1    Lee, G.2    Ehses, P.3
  • 14
    • 36049040334 scopus 로고    scopus 로고
    • Registration of dynamic contrastenhancedMRI using a progressive principal component registration (PPCR)
    • Melbourne A, Atkinson D, White M, et al. Registration of dynamic contrastenhancedMRI using a progressive principal component registration (PPCR). Phys Med Biol. 2007;52:5147-5156.
    • (2007) Phys Med Biol. , vol.52 , pp. 5147-5156
    • Melbourne, A.1    Atkinson, D.2    White, M.3
  • 16
    • 84927786087 scopus 로고    scopus 로고
    • Three-dimensional through-time radial GRAPPA for renal MR angiography
    • Wright K, Lee G, Ehses P, et al. Three-dimensional through-time radial GRAPPA for renal MR angiography. J Magn Reson Imaging. 2014;40:864-874.
    • (2014) J Magn Reson Imaging. , vol.40 , pp. 864-874
    • Wright, K.1    Lee, G.2    Ehses, P.3
  • 17
    • 35248890498 scopus 로고    scopus 로고
    • On NUFFT-based gridding for non-Cartesian MRI
    • Fessler JA. On NUFFT-based gridding for non-Cartesian MRI. J Magn Reson. 2007;188:191-195.
    • (2007) J Magn Reson. , vol.188 , pp. 191-195
    • Fessler, J.A.1
  • 19
    • 33646198875 scopus 로고    scopus 로고
    • Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla
    • Pintaske J, Martirosian P, Graf H, et al. Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in human blood plasma at 0.2, 1.5, and 3 Tesla. Invest Radiol. 2006;41:213-221.
    • (2006) Invest Radiol. , vol.41 , pp. 213-221
    • Pintaske, J.1    Martirosian, P.2    Graf, H.3
  • 20
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3 T
    • Stanisz GJ, Odrobina EE, Pun J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3 T. Magn Reson Med. 2005;54:507-512.
    • (2005) Magn Reson Med. , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 21
    • 0036136989 scopus 로고    scopus 로고
    • Assessment of hepatic perfusion parameters with dynamic MRI
    • Materne R, Smith AM, Peeters F, et al. Assessment of hepatic perfusion parameters with dynamic MRI. Magn Reson Med. 2002;47:135-142.
    • (2002) Magn Reson Med. , vol.47 , pp. 135-142
    • Materne, R.1    Smith, A.M.2    Peeters, F.3
  • 22
    • 0035115565 scopus 로고    scopus 로고
    • Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity
    • Van Beers BE, Leconte I, Materne R, et al. Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity. Am J Roentgenol. 2001;176:667-673.
    • (2001) Am J Roentgenol. , vol.176 , pp. 667-673
    • Van Beers, B.E.1    Leconte, I.2    Materne, R.3
  • 23
    • 0042913145 scopus 로고    scopus 로고
    • The origin of blood supply for cavernous hemangioma of the liver
    • Li G-W, Chen Q-L, Jiang J-T, et al. The origin of blood supply for cavernous hemangioma of the liver. Hepatobiliary Pancreat Dis Int. 2003;2:367-370.
    • (2003) Hepatobiliary Pancreat Dis Int. , vol.2 , pp. 367-370
    • Li, G.-W.1    Chen, Q.-L.2    Jiang, J.-T.3
  • 24
    • 0037208643 scopus 로고    scopus 로고
    • Hepatic hemangioma: Atypical appearances on CT, MR imaging, and sonography
    • Jang H-J, Kim TK, Lim HK, et al. Hepatic hemangioma: atypical appearances on CT, MR imaging, and sonography. Am J Roentgenol. 2003;180:135-141.
    • (2003) Am J Roentgenol. , vol.180 , pp. 135-141
    • Jang, H.-J.1    Kim, T.K.2    Lim, H.K.3
  • 25
    • 84894466006 scopus 로고    scopus 로고
    • High-spatial and high-temporal resolution dynamic contrast-enhanced perfusion imaging of the liver with timeresolved three-dimensional radial MRI
    • Brodsky EK, Bultman EM, Johnson KM, et al. High-spatial and high-temporal resolution dynamic contrast-enhanced perfusion imaging of the liver with timeresolved three-dimensional radial MRI. Magn Reson Med. 2014;71:934-941.
    • (2014) Magn Reson Med. , vol.71 , pp. 934-941
    • Brodsky, E.K.1    Bultman, E.M.2    Johnson, K.M.3
  • 26
    • 84877142340 scopus 로고    scopus 로고
    • Free-breathing dynamic contrast-enhancedMRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC)
    • KimKW, Lee JM, JeonYS, et al. Free-breathing dynamic contrast-enhancedMRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC). Eur Radiol. 2013;23:1352-1360.
    • (2013) Eur Radiol. , vol.23 , pp. 1352-1360
    • Kim, K.W.1    Lee, J.M.2    Jeon, Y.S.3
  • 27
    • 84872954393 scopus 로고    scopus 로고
    • Fast 3D contrast enhanced MRI of the liver using temporal resolution acceleration with constrained evolution reconstruction
    • Xu B, Spincemaille P, Chen G, et al. Fast 3D contrast enhanced MRI of the liver using temporal resolution acceleration with constrained evolution reconstruction. Magn Reson Med. 2013;69:370-381.
    • (2013) Magn Reson Med. , vol.69 , pp. 370-381
    • Xu, B.1    Spincemaille, P.2    Chen, G.3
  • 28
    • 84862487917 scopus 로고    scopus 로고
    • Combined quantification of liver perfusion and function with dynamic gadoxetic acid-enhanced MR imaging
    • Sourbron S, Reiser MF, Zech CJ. Combined quantification of liver perfusion and function with dynamic gadoxetic acid-enhanced MR imaging. Radiology. 2012; 263:874-883.
    • (2012) Radiology. , vol.263 , pp. 874-883
    • Sourbron, S.1    Reiser, M.F.2    Zech, C.J.3
  • 29
    • 84925780147 scopus 로고    scopus 로고
    • Quantitative high-resolution renal perfusion imaging using 3-dimensional through-time radial generalized autocalibrating partially parallel acquisition
    • Wright KL, Chen Y, Saybasili H, et al. Quantitative high-resolution renal perfusion imaging using 3-dimensional through-time radial generalized autocalibrating partially parallel acquisition. Invest Radiol. 2014;49:666-674.
    • (2014) Invest Radiol. , vol.49 , pp. 666-674
    • Wright, K.L.1    Chen, Y.2    Saybasili, H.3
  • 30
    • 79954442395 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced MRI of neuroendocrine hepatic metastases: A feasibility study using a dual-input twocompartment model
    • Koh TS, Thng CH, Hartono S, et al. Dynamic contrast-enhanced MRI of neuroendocrine hepatic metastases: A feasibility study using a dual-input twocompartment model. Magn Reson Med. 2011;65:250-260.
    • (2011) Magn Reson Med. , vol.65 , pp. 250-260
    • Koh, T.S.1    Thng, C.H.2    Hartono, S.3
  • 31
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • GriswoldMA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202-1210.
    • (2002) Magn Reson Med. , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 32
    • 84901021545 scopus 로고    scopus 로고
    • Real-time imaging with radial GRAPPA: Implementation on a heterogeneous architecture for low-latency reconstructions
    • Saybasili H, Herzka DA, Seiberlich N, et al. Real-time imaging with radial GRAPPA: implementation on a heterogeneous architecture for low-latency reconstructions. Magn Reson Imaging. 2014;32:747-758.
    • (2014) Magn Reson Imaging. , vol.32 , pp. 747-758
    • Saybasili, H.1    Herzka, D.A.2    Seiberlich, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.