메뉴 건너뛰기




Volumn 66, Issue 6, 2011, Pages 1682-1688

Improved temporal resolution in cardiac imaging using through-time spiral GRAPPA

Author keywords

cardiac imaging; GRAPPA; non Cartesian; parallel imaging; real time imaging; spiral

Indexed keywords

HEART; SOLDERED JOINTS; TRAJECTORIES;

EID: 81355147810     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22952     Document Type: Article
Times cited : (49)

References (16)
  • 1
    • 0742334051 scopus 로고    scopus 로고
    • Direct parallel imaging reconstruction of radially sampled data using GRAPPA with relative shifts
    • Toronto, Canada
    • Griswold MA, Heidemann RM, Jakob PM,. Direct parallel imaging reconstruction of radially sampled data using GRAPPA with relative shifts. In: Proceedings of the 11th Annual Meeting of the ISMRM. Toronto, Canada; 2003. p 2349.
    • (2003) Proceedings of the 11th Annual Meeting of the ISMRM , pp. 2349
    • Griswold, M.A.1    Heidemann, R.M.2    Jakob, P.M.3
  • 3
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Boernert P, Boesiger P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Boernert, P.3    Boesiger, P.4
  • 4
    • 19544369296 scopus 로고    scopus 로고
    • Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): Constrained image reconstruction using k-space locality in radiofrequency coil encoded data
    • Yeh EN, McKenzie CA, Ohliger MA, Sodickson DK,. Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data. Magn Reson Med 2005; 53: 1383-1392.
    • (2005) Magn Reson Med , vol.53 , pp. 1383-1392
    • Yeh, E.N.1    McKenzie, C.A.2    Ohliger, M.A.3    Sodickson, D.K.4
  • 5
    • 42549123682 scopus 로고    scopus 로고
    • Reconstruction of undersampled non-Cartesian data sets using pseudo-Cartesian GRAPPA in conjunction with GROG
    • Seiberlich N, Breuer F, Heidemann R, Blaimer M, Griswold M, Jakob P,. Reconstruction of undersampled non-Cartesian data sets using pseudo-Cartesian GRAPPA in conjunction with GROG. Magn Reson Med 2008; 59: 1127-1137.
    • (2008) Magn Reson Med , vol.59 , pp. 1127-1137
    • Seiberlich, N.1    Breuer, F.2    Heidemann, R.3    Blaimer, M.4    Griswold, M.5    Jakob, P.6
  • 6
    • 33644804967 scopus 로고    scopus 로고
    • Auto-calibrated parallel spiral imaging
    • Heberlein K, Hu X,. Auto-calibrated parallel spiral imaging. Magn Reson Med 2006; 55: 619-625.
    • (2006) Magn Reson Med , vol.55 , pp. 619-625
    • Heberlein, K.1    Hu, X.2
  • 8
    • 79251579662 scopus 로고    scopus 로고
    • Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging
    • Seiberlich N, Ehses P, Duerk J, Gilkeson R, Griswold M,. Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging. Magn Reson Med 2011; 65: 492-505.
    • (2011) Magn Reson Med , vol.65 , pp. 492-505
    • Seiberlich, N.1    Ehses, P.2    Duerk, J.3    Gilkeson, R.4    Griswold, M.5
  • 12
    • 0346373772 scopus 로고    scopus 로고
    • Time-optimal multidimensional gradient waveform design for rapid imaging
    • Hargreaves BA, Nishimura DG, Conolly SM,. Time-optimal multidimensional gradient waveform design for rapid imaging. Magn Reson Med 2004; 51: 81-92.
    • (2004) Magn Reson Med , vol.51 , pp. 81-92
    • Hargreaves, B.A.1    Nishimura, D.G.2    Conolly, S.M.3
  • 13
    • 0032059889 scopus 로고    scopus 로고
    • Simple correction method for k-space trajectory deviations in MRI
    • Duyn JH, Yang Y, Frank JA, van der Veen JW,. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson 1998; 132: 150-153.
    • (1998) J Magn Reson , vol.132 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    Van Der Veen, J.W.4
  • 14
    • 80051591726 scopus 로고    scopus 로고
    • A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation
    • in press
    • Codella NC, Spincemaille P, Prince M, Wang Y,. A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation. NMR Biomed; in press.
    • NMR Biomed
    • Codella, N.C.1    Spincemaille, P.2    Prince, M.3    Wang, Y.4
  • 15
    • 35248890498 scopus 로고    scopus 로고
    • On NUFFT-based gridding for non-Cartesian MRI
    • Fessler JA,. On NUFFT-based gridding for non-Cartesian MRI. J Magn Reson 2007; 188: 191-195.
    • (2007) J Magn Reson , vol.188 , pp. 191-195
    • Fessler, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.