메뉴 건너뛰기




Volumn 45, Issue 3, 1999, Pages 603-611

Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation

Author keywords

Breath hold; Lung carcinoma; Respiration gating; Spirometry

Indexed keywords

ADULT; AGED; ARTICLE; BREATH HOLDING; BREATHING; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DENSITY; DOSIMETRY; FEMALE; HUMAN; LUNG CARCINOMA; LUNG NON SMALL CELL CANCER; MALE; PRIORITY JOURNAL; SPIROMETRY; TECHNIQUE;

EID: 0032844267     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(99)00154-6     Document Type: Article
Times cited : (535)

References (22)
  • 2
    • 0025332165 scopus 로고
    • Analysis of movement of intrathoracic neoplasms using ultrafast computed tomography
    • Ross C.S., Hussey D.H., Pennington E.C., et al. Analysis of movement of intrathoracic neoplasms using ultrafast computed tomography. Int J Radiat Oncol Biol Phys. 18:1990;671-677.
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 671-677
    • Ross, C.S.1    Hussey, D.H.2    Pennington, E.C.3
  • 3
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: A technical study
    • Kubo H.D., Hill B.C. Respiration gated radiotherapy treatment A technical study . Phys Med Biol. 41:1996;83-91.
    • (1996) Phys Med Biol , vol.41 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 4
    • 0031895830 scopus 로고    scopus 로고
    • Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation
    • Steene JVd, Huevel Fvd, Bel A., et al. Electronic portal imaging with on-line correction of setup error in thoracic irradiation Clinical evaluation . Int J Radiat Oncol Biol Phys. 40:1998;967-976.
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 967-976
    • Steene, J.1    Huevel, F.2    Bel, A.3
  • 5
    • 0022101788 scopus 로고
    • A simple device for breath-level monitoring during CT
    • Frohlich H., Dohring W. A simple device for breath-level monitoring during CT. Radiology. 156:1985;235.
    • (1985) Radiology , vol.156 , pp. 235
    • Frohlich, H.1    Dohring, W.2
  • 6
    • 0025349284 scopus 로고
    • Measurement of pulmonary parenchymal attenuation: Use of spirometric gating with quantitative CT
    • Kalender W.A., Reinmuller R., Seissler W., et al. Measurement of pulmonary parenchymal attenuation Use of spirometric gating with quantitative CT . Radiology. 175:1990;265-268.
    • (1990) Radiology , vol.175 , pp. 265-268
    • Kalender, W.A.1    Reinmuller, R.2    Seissler, W.3
  • 8
    • 0344705704 scopus 로고    scopus 로고
    • Treatment with active breathing control (ABC) in the thoracic and upper abdominal regions
    • (Abstr.)
    • Wong J.W., Kini V., Sharpe M., et al. Treatment with active breathing control (ABC) in the thoracic and upper abdominal regions. (Abstr.) Med Phys. 25:1998;A127.
    • (1998) Med Phys , vol.25 , pp. 127
    • Wong, J.W.1    Kini, V.2    Sharpe, M.3
  • 9
    • 0025939587 scopus 로고
    • Tolerance of normal tissue to therapeutic irradiation
    • Emami B., Lyman J., Brown A., et al. Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys. 21:1991;109-122.
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 109-122
    • Emami, B.1    Lyman, J.2    Brown, A.3
  • 10
    • 0344466033 scopus 로고
    • Dose-volume histogram and 3-D/CT treatment planning evaluation of patients with radiation pneumonitis
    • Martel M.K., TenHaken R.K., Hazuka M.B., et al. Dose-volume histogram and 3-D/CT treatment planning evaluation of patients with radiation pneumonitis. Int J Radiat Oncol Biol Phys. 24:1992;175.
    • (1992) Int J Radiat Oncol Biol Phys , vol.24 , pp. 175
    • Martel, M.K.1    Tenhaken, R.K.2    Hazuka, M.B.3
  • 11
    • 0027323834 scopus 로고
    • Three-dimensional conformal therapy may improve the therapeutic ratio of high dose radiation therapy for lung cancer
    • Armstrong J.G., Burman C., Leibel S., et al. Three-dimensional conformal therapy may improve the therapeutic ratio of high dose radiation therapy for lung cancer. Int J Radiat Oncol Biol Phys. 26:1993;685-689.
    • (1993) Int J Radiat Oncol Biol Phys , vol.26 , pp. 685-689
    • Armstrong, J.G.1    Burman, C.2    Leibel, S.3
  • 12
    • 0344034909 scopus 로고
    • Standardization of spirometry
    • Standardization of spirometry. AJRCCM. 152:1994.
    • (1994) AJRCCM , vol.152
  • 13
    • 0023761406 scopus 로고
    • A comprehensive three-dimensional radiation treatment planning system
    • Mohan R., Barest G., Brewster L., et al. A comprehensive three-dimensional radiation treatment planning system. Int J Radiat Oncol Biol Phys. 15:1988;481-495.
    • (1988) Int J Radiat Oncol Biol Phys , vol.15 , pp. 481-495
    • Mohan, R.1    Barest, G.2    Brewster, L.3
  • 14
    • 0025095274 scopus 로고
    • Pitfalls in the use of high energy x rays to treat tumors in the lung
    • Ekstrand K.E., Barnes W.H. Pitfalls in the use of high energy x rays to treat tumors in the lung. Int J Radiat Oncol Biol Phys. 18:1990;249-252.
    • (1990) Int J Radiat Oncol Biol Phys , vol.18 , pp. 249-252
    • Ekstrand, K.E.1    Barnes, W.H.2
  • 15
    • 0026093854 scopus 로고
    • Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations
    • Kutcher G.J., Burman C., Brewster L., et al. Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations. Int J Radiat Oncol Biol Phys. 21:1991;137-146.
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 137-146
    • Kutcher, G.J.1    Burman, C.2    Brewster, L.3
  • 16
    • 0022323855 scopus 로고
    • Complication probability as assessed from dose-volume histograms
    • Lyman J.T. Complication probability as assessed from dose-volume histograms. Radiat Res. 104:1985;S13-S19.
    • (1985) Radiat Res , vol.104
    • Lyman, J.T.1
  • 17
    • 0003100941 scopus 로고    scopus 로고
    • Relationship between respiration gated irradiation and actual respiratory movement of tumors
    • Terahara A., Osaka Y., Mizoe J., et al. Relationship between respiration gated irradiation and actual respiratory movement of tumors. Radiother Oncol. 48:1998;S47.
    • (1998) Radiother Oncol , vol.48 , pp. 47
    • Terahara, A.1    Osaka, Y.2    Mizoe, J.3
  • 18
    • 0022638891 scopus 로고
    • Accuracy of lung dose calculations for large-field irradiation with 6 MV x-rays
    • El-Khatib E., Battista J.J. Accuracy of lung dose calculations for large-field irradiation with 6 MV x-rays. Med Phys. 13:1986;111-116.
    • (1986) Med Phys , vol.13 , pp. 111-116
    • El-Khatib, E.1    Battista, J.J.2
  • 19
    • 0027443305 scopus 로고
    • The influence of air cavities on interface doses for photon beams
    • Klein E.E., Chin L.M., Rice R.K., et al. The influence of air cavities on interface doses for photon beams. Int J Radiat Oncol Biol Phys. 27:1993;419-427.
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 419-427
    • Klein, E.E.1    Chin, L.M.2    Rice, R.K.3
  • 20
    • 0025939586 scopus 로고
    • Role of inhomogeneity corrections in three-dimensional photon treatment planning
    • Mohan R. Role of inhomogeneity corrections in three-dimensional photon treatment planning. Int J Radiat Oncol Biol Phys. 21:1991;59-69.
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 59-69
    • Mohan, R.1
  • 21
    • 0029939206 scopus 로고    scopus 로고
    • Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6 MV and 18 MV photons
    • White P.J., Zwicker R.D., Huang D.T. Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6 MV and 18 MV photons. Int J Radiat Oncol Biol Phys. 34:1996.
    • (1996) Int J Radiat Oncol Biol Phys , vol.34
    • White, P.J.1    Zwicker, R.D.2    Huang, D.T.3
  • 22
    • 0012332260 scopus 로고    scopus 로고
    • Verification of inflation level and lung position during breath hold lung treatment using on-line imaging
    • Debois M.M., Hanley J., Mageras G.S., et al. Verification of inflation level and lung position during breath hold lung treatment using on-line imaging. Med Phys. 23:1996;1082.
    • (1996) Med Phys , vol.23 , pp. 1082
    • Debois, M.M.1    Hanley, J.2    Mageras, G.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.