-
1
-
-
0142104467
-
Response to volume resuscitation in children with severe malaria
-
Maitland, K, Pamba, A, Newton, CR, Levin, M, Response to volume resuscitation in children with severe malaria. Pediatr Crit Care Med 4 (2003), 426–431.
-
(2003)
Pediatr Crit Care Med
, vol.4
, pp. 426-431
-
-
Maitland, K.1
Pamba, A.2
Newton, C.R.3
Levin, M.4
-
2
-
-
84861116704
-
Fluid overload is associated with impaired oxygenation and morbidity in critically ill children
-
Arikan, AA, Zappitelli, M, Goldstein, SL, Naipaul, A, Jefferson, LS, Loftis, LL, Fluid overload is associated with impaired oxygenation and morbidity in critically ill children. Pediatr Crit Care Med 13 (2012), 253–258.
-
(2012)
Pediatr Crit Care Med
, vol.13
, pp. 253-258
-
-
Arikan, A.A.1
Zappitelli, M.2
Goldstein, S.L.3
Naipaul, A.4
Jefferson, L.S.5
Loftis, L.L.6
-
3
-
-
84880538029
-
Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense
-
Marik, PE, Cavallazzi, R, Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med 41 (2013), 1774–1781.
-
(2013)
Crit Care Med
, vol.41
, pp. 1774-1781
-
-
Marik, P.E.1
Cavallazzi, R.2
-
4
-
-
33845958648
-
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
-
Osman, D, Ridel, C, Ray, P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 35 (2007), 64–68.
-
(2007)
Crit Care Med
, vol.35
, pp. 64-68
-
-
Osman, D.1
Ridel, C.2
Ray, P.3
-
5
-
-
42449127054
-
Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children
-
Durand, P, Chevret, L, Essouri, S, Haas, V, Devictor, D, Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med 34 (2008), 888–894.
-
(2008)
Intensive Care Med
, vol.34
, pp. 888-894
-
-
Durand, P.1
Chevret, L.2
Essouri, S.3
Haas, V.4
Devictor, D.5
-
6
-
-
79959659600
-
Non-invasive prediction of fluid responsiveness in infants using pleth variability index
-
Renner, J, Broch, O, Gruenewald, M, et al. Non-invasive prediction of fluid responsiveness in infants using pleth variability index. Anaesthesia 66 (2011), 582–589.
-
(2011)
Anaesthesia
, vol.66
, pp. 582-589
-
-
Renner, J.1
Broch, O.2
Gruenewald, M.3
-
7
-
-
84055188819
-
Intraoperative use of transoesophageal Doppler to predict response to volume expansion in infants and neonates
-
Raux, O, Spencer, A, Fesseau, R, et al. Intraoperative use of transoesophageal Doppler to predict response to volume expansion in infants and neonates. Br J Anaesth 108 (2012), 100–107.
-
(2012)
Br J Anaesth
, vol.108
, pp. 100-107
-
-
Raux, O.1
Spencer, A.2
Fesseau, R.3
-
8
-
-
84055182994
-
Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery
-
Renner, J, Broch, O, Duetschke, P, et al. Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery. Br J Anaesth 108 (2012), 108–115.
-
(2012)
Br J Anaesth
, vol.108
, pp. 108-115
-
-
Renner, J.1
Broch, O.2
Duetschke, P.3
-
9
-
-
84872864626
-
Evaluation of central venous pressure monitoring in children undergoing craniofacial reconstruction surgery
-
Stricker, PA, Lin, EE, Fiadjoe, JE, et al. Evaluation of central venous pressure monitoring in children undergoing craniofacial reconstruction surgery. Anesth Analg 116 (2013), 411–419.
-
(2013)
Anesth Analg
, vol.116
, pp. 411-419
-
-
Stricker, P.A.1
Lin, E.E.2
Fiadjoe, J.E.3
-
10
-
-
84889061184
-
Predicting fluid responsiveness in children: a systematic review
-
Gan, H, Cannesson, M, Chandler, JR, Ansermino, JM, Predicting fluid responsiveness in children: a systematic review. Anesth Analg 117 (2013), 1380–1392.
-
(2013)
Anesth Analg
, vol.117
, pp. 1380-1392
-
-
Gan, H.1
Cannesson, M.2
Chandler, J.R.3
Ansermino, J.M.4
-
11
-
-
84875363951
-
Assessment of volume responsiveness during mechanical ventilation: recent advances
-
Monnet, X, Teboul, JL, Assessment of volume responsiveness during mechanical ventilation: recent advances. Crit Care, 17, 2013, 217.
-
(2013)
Crit Care
, vol.17
, pp. 217
-
-
Monnet, X.1
Teboul, J.L.2
-
12
-
-
0036283553
-
Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence
-
Michard, F, Teboul, JL, Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 121 (2002), 2000–2008.
-
(2002)
Chest
, vol.121
, pp. 2000-2008
-
-
Michard, F.1
Teboul, J.L.2
-
13
-
-
84866738251
-
Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis
-
Sandroni, C, Cavallaro, F, Marano, C, Falcone, C, De Santis, P, Antonelli, M, Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis. Intensive Care Med 38 (2012), 1429–1437.
-
(2012)
Intensive Care Med
, vol.38
, pp. 1429-1437
-
-
Sandroni, C.1
Cavallaro, F.2
Marano, C.3
Falcone, C.4
De Santis, P.5
Antonelli, M.6
-
14
-
-
84884143876
-
Monitoring volume and fluid responsiveness: from static to dynamic indicators
-
Guerin, L, Monnet, X, Teboul, JL, Monitoring volume and fluid responsiveness: from static to dynamic indicators. Best Pract Res Clin Anaesthesiol 27 (2013), 177–185.
-
(2013)
Best Pract Res Clin Anaesthesiol
, vol.27
, pp. 177-185
-
-
Guerin, L.1
Monnet, X.2
Teboul, J.L.3
-
15
-
-
79959854628
-
Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index
-
Broch, O, Bein, B, Gruenewald, M, et al. Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index. Acta Anaesthesiol Scand 55 (2011), 686–693.
-
(2011)
Acta Anaesthesiol Scand
, vol.55
, pp. 686-693
-
-
Broch, O.1
Bein, B.2
Gruenewald, M.3
-
16
-
-
84893658401
-
The ability of stroke volume variation measured by a noninvasive cardiac output monitor to predict fluid responsiveness in mechanically ventilated children
-
Lee, JY, Kim, JY, Choi, CH, Kim, HS, Lee, KC, Kwak, HJ, The ability of stroke volume variation measured by a noninvasive cardiac output monitor to predict fluid responsiveness in mechanically ventilated children. Pediatr Cardiol 35 (2014), 289–294.
-
(2014)
Pediatr Cardiol
, vol.35
, pp. 289-294
-
-
Lee, J.Y.1
Kim, J.Y.2
Choi, C.H.3
Kim, H.S.4
Lee, K.C.5
Kwak, H.J.6
-
17
-
-
79957533123
-
Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography
-
Pereira de Souza Neto, E, Grousson, S, Duflo, F, et al. Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth 106 (2011), 856–864.
-
(2011)
Br J Anaesth
, vol.106
, pp. 856-864
-
-
Pereira de Souza Neto, E.1
Grousson, S.2
Duflo, F.3
-
18
-
-
0013978742
-
Development and evaluation of an impedance cardiac output system
-
Kubicek, WG, Karnegis, JN, Patterson, RP, Witsoe, DA, Mattson, RH, Development and evaluation of an impedance cardiac output system. Aerosp Med 37 (1966), 1208–1212.
-
(1966)
Aerosp Med
, vol.37
, pp. 1208-1212
-
-
Kubicek, W.G.1
Karnegis, J.N.2
Patterson, R.P.3
Witsoe, D.A.4
Mattson, R.H.5
-
19
-
-
43349098041
-
Assessment of stroke volume index with three different bioimpedance algorithms: lack of agreement compared to thermodilution
-
de Waal, EE, Konings, MK, Kalkman, CJ, Buhre, WF, Assessment of stroke volume index with three different bioimpedance algorithms: lack of agreement compared to thermodilution. Intensive Care Med 34 (2008), 735–739.
-
(2008)
Intensive Care Med
, vol.34
, pp. 735-739
-
-
de Waal, E.E.1
Konings, M.K.2
Kalkman, C.J.3
Buhre, W.F.4
-
20
-
-
65349115982
-
Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography
-
Fellahi, JL, Caille, V, Charron, C, Deschamps-Berger, PH, Vieillard-Baron, A, Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography. Anesth Analg 108 (2009), 1553–1559.
-
(2009)
Anesth Analg
, vol.108
, pp. 1553-1559
-
-
Fellahi, J.L.1
Caille, V.2
Charron, C.3
Deschamps-Berger, P.H.4
Vieillard-Baron, A.5
-
21
-
-
78650415602
-
Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test
-
Benomar, B, Ouattara, A, Estagnasie, P, Brusset, A, Squara, P, Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med 36 (2010), 1875–1881.
-
(2010)
Intensive Care Med
, vol.36
, pp. 1875-1881
-
-
Benomar, B.1
Ouattara, A.2
Estagnasie, P.3
Brusset, A.4
Squara, P.5
-
22
-
-
84874059490
-
The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients
-
Marik, PE, Levitov, A, Young, A, Andrews, L, The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest 143 (2013), 364–370.
-
(2013)
Chest
, vol.143
, pp. 364-370
-
-
Marik, P.E.1
Levitov, A.2
Young, A.3
Andrews, L.4
-
23
-
-
84887913010
-
Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients
-
Kupersztych-Hagege, E, Teboul, JL, Artigas, A, et al. Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Br J Anaesth 111 (2013), 961–966.
-
(2013)
Br J Anaesth
, vol.111
, pp. 961-966
-
-
Kupersztych-Hagege, E.1
Teboul, J.L.2
Artigas, A.3
-
24
-
-
34547132055
-
Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
-
Keren, H, Burkhoff, D, Squara, P, Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol 293 (2007), H583–H589.
-
(2007)
Am J Physiol Heart Circ Physiol
, vol.293
, pp. H583-H589
-
-
Keren, H.1
Burkhoff, D.2
Squara, P.3
-
25
-
-
9644302430
-
A novel algorithm to estimate the pulse pressure variation index deltaPP
-
Aboy, M, McNames, J, Thong, T, Phillips, CR, Ellenby, MS, Goldstein, B, A novel algorithm to estimate the pulse pressure variation index deltaPP. IEEE Trans Biomed Eng 51 (2004), 2198–2203.
-
(2004)
IEEE Trans Biomed Eng
, vol.51
, pp. 2198-2203
-
-
Aboy, M.1
McNames, J.2
Thong, T.3
Phillips, C.R.4
Ellenby, M.S.5
Goldstein, B.6
-
26
-
-
41349122492
-
The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room
-
Cannesson, M, Slieker, J, Desebbe, O, et al. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg 106 (2008), 1195–1200.
-
(2008)
Anesth Analg
, vol.106
, pp. 1195-1200
-
-
Cannesson, M.1
Slieker, J.2
Desebbe, O.3
-
27
-
-
80053322000
-
Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a ‘gray zone’ approach
-
Cannesson, M, Le Manach, Y, Hofer, CK, et al. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a ‘gray zone’ approach. Anesthesiology 115 (2011), 231–241.
-
(2011)
Anesthesiology
, vol.115
, pp. 231-241
-
-
Cannesson, M.1
Le Manach, Y.2
Hofer, C.K.3
-
28
-
-
0038187644
-
A grey zone for quantitative diagnostic and screening tests
-
Coste, J, Pouchot, J, A grey zone for quantitative diagnostic and screening tests. Int J Epidemiol 32 (2003), 304–313.
-
(2003)
Int J Epidemiol
, vol.32
, pp. 304-313
-
-
Coste, J.1
Pouchot, J.2
-
30
-
-
0032247707
-
Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients
-
Shoemaker, WC, Belzberg, H, Wo, CC, et al. Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. Chest 114 (1998), 1643–1652.
-
(1998)
Chest
, vol.114
, pp. 1643-1652
-
-
Shoemaker, W.C.1
Belzberg, H.2
Wo, C.C.3
-
31
-
-
79953674181
-
Measurement of cardiac output in children by bioreactance
-
Ballestero, Y, Lopez-Herce, J, Urbano, J, et al. Measurement of cardiac output in children by bioreactance. Pediatr Cardiol 32 (2011), 469–472.
-
(2011)
Pediatr Cardiol
, vol.32
, pp. 469-472
-
-
Ballestero, Y.1
Lopez-Herce, J.2
Urbano, J.3
-
32
-
-
84865805243
-
Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography
-
Noori, S, Drabu, B, Soleymani, S, Seri, I, Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed 97 (2012), F340–F343.
-
(2012)
Arch Dis Child Fetal Neonatal Ed
, vol.97
, pp. F340-F343
-
-
Noori, S.1
Drabu, B.2
Soleymani, S.3
Seri, I.4
-
33
-
-
84859722664
-
Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography
-
Weisz, DE, Jain, A, McNamara, PJ, EL-Khuffash, A, Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography. Neonatology 102 (2012), 61–67.
-
(2012)
Neonatology
, vol.102
, pp. 61-67
-
-
Weisz, D.E.1
Jain, A.2
McNamara, P.J.3
EL-Khuffash, A.4
-
34
-
-
84920690069
-
Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients
-
Advance Access published on May 12
-
Vergnaud, E, Vidal, C, Montmayeur Verchere, J, et al. Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients. Paediatr Anaesth, 2014 Advance Access published on May 12 doi:10.1111/pan.12412.
-
(2014)
Paediatr Anaesth
-
-
Vergnaud, E.1
Vidal, C.2
Montmayeur Verchere, J.3
-
35
-
-
84877581329
-
Plethysmographic variability index (PVI) accuracy in predicting fluid responsiveness in anesthetized children
-
Julien, F, Hilly, J, Sallah, TB, et al. Plethysmographic variability index (PVI) accuracy in predicting fluid responsiveness in anesthetized children. Paediatr Anaesth 23 (2013), 536–546.
-
(2013)
Paediatr Anaesth
, vol.23
, pp. 536-546
-
-
Julien, F.1
Hilly, J.2
Sallah, T.B.3
-
36
-
-
84885566049
-
Developmental physiology of the cardiovascular system
-
GA Gregory DB Andropoulos Wiley-Blackwell Oxford
-
Miller-Hance, W, Wilmot, I, Andropoulos, DB, Developmental physiology of the cardiovascular system. Gregory, GA, Andropoulos, DB, (eds.) Gregory's Pediatric Anesthesia, 2012, Wiley-Blackwell, Oxford, 60–94.
-
(2012)
Gregory's Pediatric Anesthesia
, pp. 60-94
-
-
Miller-Hance, W.1
Wilmot, I.2
Andropoulos, D.B.3
-
37
-
-
84893872955
-
The utility of stroke volume variability as a predictor of fluid responsiveness in critically ill children: a pilot study
-
McLean, JR, Inwald, DP, The utility of stroke volume variability as a predictor of fluid responsiveness in critically ill children: a pilot study. Intensive Care Med 40 (2014), 288–289.
-
(2014)
Intensive Care Med
, vol.40
, pp. 288-289
-
-
McLean, J.R.1
Inwald, D.P.2
-
38
-
-
34447131664
-
Noninvasive cardiac output monitoring (NICOM): a clinical validation
-
Squara, P, Denjean, D, Estagnasie, P, Brusset, A, Dib, JC, Dubois, C, Noninvasive cardiac output monitoring (NICOM): a clinical validation. Intensive Care Med 33 (2007), 1191–1194.
-
(2007)
Intensive Care Med
, vol.33
, pp. 1191-1194
-
-
Squara, P.1
Denjean, D.2
Estagnasie, P.3
Brusset, A.4
Dib, J.C.5
Dubois, C.6
-
39
-
-
0344394235
-
Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature
-
Chew, MS, Poelaert, J, Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med 29 (2003), 1889–1894.
-
(2003)
Intensive Care Med
, vol.29
, pp. 1889-1894
-
-
Chew, M.S.1
Poelaert, J.2
-
40
-
-
0029886584
-
Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method
-
Wippermann, CF, Huth, RG, Schmidt, FX, Thul, J, Betancor, M, Schranz, D, Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method. Intensive Care Med 22 (1996), 467–471.
-
(1996)
Intensive Care Med
, vol.22
, pp. 467-471
-
-
Wippermann, C.F.1
Huth, R.G.2
Schmidt, F.X.3
Thul, J.4
Betancor, M.5
Schranz, D.6
|