메뉴 건너뛰기




Volumn 36, Issue 11, 2010, Pages 1875-1881

Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test

Author keywords

Cardiac output; Fluid response; Monitoring

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; DEVICE; FEMALE; FLUID RESPONSIVENESS; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HEART STROKE VOLUME; HEMODYNAMICS; HUMAN; LEG MOVEMENT; MAJOR CLINICAL STUDY; MALE; NON INVASIVE MEASUREMENT; PREDICTION; PROSPECTIVE STUDY; SENSITIVITY ANALYSIS;

EID: 78650415602     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-010-1990-6     Document Type: Article
Times cited : (103)

References (40)
  • 1
    • 0024273739 scopus 로고
    • Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients
    • Shoemaker W, Appel P, Kram H, Waxman K, Lee T (1988) Prospective trial of supranormal values of survivors as therapeutic goals in high-risk surgical patients. Chest 94:1176-1186
    • (1988) Chest , vol.94 , pp. 1176-1186
    • Shoemaker, W.1    Appel, P.2    Kram, H.3    Waxman, K.4    Lee, T.5
  • 2
    • 0027427633 scopus 로고
    • A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients
    • Boyd O, Grounds RM, Bennett ED (1993) A randomized clinical trial of the effect of deliberate perioperative increase of oxygen delivery on mortality in high-risk surgical patients. JAMA 270:2699-2707
    • (1993) JAMA , vol.270 , pp. 2699-2707
    • Boyd, O.1    Grounds, R.M.2    Bennett, E.D.3
  • 4
    • 22944483442 scopus 로고    scopus 로고
    • Intraoperative fluid restriction improves outcome after major elective gastrointestinal surgery
    • Joshi GP (2005) Intraoperative fluid restriction improves outcome after major elective gastrointestinal surgery. Anesth Analg 101:601-605
    • (2005) Anesth Analg , vol.101 , pp. 601-605
    • Joshi, G.P.1
  • 5
    • 0036288683 scopus 로고    scopus 로고
    • Perioperative beta-blockers in high-risk patients
    • Martinez EA, Pronovost P (2002) Perioperative beta-blockers in high-risk patients. J Crit Care 17:105-113
    • (2002) J Crit Care , vol.17 , pp. 105-113
    • Martinez, E.A.1    Pronovost, P.2
  • 7
    • 34248163905 scopus 로고    scopus 로고
    • Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: A randomized controlled trial
    • Chytra I, Pradl R, Bosman R, Pelnar P, Kasal E, Zidkova A (2007) Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: A randomized controlled trial. Crit Care 11:R24
    • (2007) Crit Care , vol.11
    • Chytra, I.1    Pradl, R.2    Bosman, R.3    Pelnar, P.4    Kasal, E.5    Zidkova, A.6
  • 8
    • 0030843904 scopus 로고    scopus 로고
    • Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial
    • Sinclair S, James S, Singer M (1997) Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: Randomised controlled trial. BMJ 315:909-912
    • (1997) BMJ , vol.315 , pp. 909-912
    • Sinclair, S.1    James, S.2    Singer, M.3
  • 9
    • 55949131423 scopus 로고    scopus 로고
    • Improving perioperative outcomes: Fluid optimization with the esophageal Doppler monitor, a metaanalysis and review
    • Phan T, Ismail H, Heriot A, Ho K (2008) Improving perioperative outcomes: fluid optimization with the esophageal Doppler monitor, a metaanalysis and review. J Am Coll Surg 207:935-941
    • (2008) J Am Coll Surg , vol.207 , pp. 935-941
    • Phan, T.1    Ismail, H.2    Heriot, A.3    Ho, K.4
  • 10
    • 64949201153 scopus 로고    scopus 로고
    • Less is more: Improved outcomes in surgical patients with conservative fluid administration and central venous catheter monitoring
    • discussion 735-727
    • Stewart R, Park P, Hunt J, McIntyre RJ, McCarthy J, Zarzabal L, Michalek J (2009) Less is more: Improved outcomes in surgical patients with conservative fluid administration and central venous catheter monitoring. J Am Coll Surg 208:725-735; discussion 735-727
    • (2009) J Am Coll Surg , vol.208 , pp. 725-735
    • Stewart, R.1    Park, P.2    Hunt, J.3    McIntyre, R.J.4    McCarthy, J.5    Zarzabal, L.6    Michalek, J.7
  • 14
    • 43449086396 scopus 로고    scopus 로고
    • Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity
    • Teboul J, Monnet X (2008) Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity. Curr Opin Crit Care 14:334-339
    • (2008) Curr Opin Crit Care , vol.14 , pp. 334-339
    • Teboul, J.1    Monnet, X.2
  • 17
    • 34447117107 scopus 로고    scopus 로고
    • Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity
    • Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL (2007) Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 33:1125-1132
    • (2007) Intensive Care Med , vol.33 , pp. 1125-1132
    • Lamia, B.1    Ochagavia, A.2    Monnet, X.3    Chemla, D.4    Richard, C.5    Teboul, J.L.6
  • 18
    • 68849121782 scopus 로고    scopus 로고
    • Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies: with specific reference to the measurement of cardiac output
    • Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds R (2009) Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies: with specific reference to the measurement of cardiac output. Crit Care 13:201
    • (2009) Crit Care , vol.13 , pp. 201
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, R.5
  • 19
    • 58549089484 scopus 로고    scopus 로고
    • Passive leg raising for predicting fluid responsiveness: Importance of the postural change
    • Jabot J, Teboul J, Richard C, Monnet X (2009) Passive leg raising for predicting fluid responsiveness: Importance of the postural change. Intensive Care Med 35:85-90
    • (2009) Intensive Care Med , vol.35 , pp. 85-90
    • Jabot, J.1    Teboul, J.2    Richard, C.3    Monnet, X.4
  • 20
    • 33847038782 scopus 로고    scopus 로고
    • Monitoring of perioperative fluid administration by individualized goal-directed therapy
    • Bundgaard-Nielsen M, Holte K, Secher N, Kehlet H (2007) Monitoring of perioperative fluid administration by individualized goal-directed therapy. Acta Anaesthesiol Scand 51:331-340
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 331-340
    • Bundgaard-Nielsen, M.1    Holte, K.2    Secher, N.3    Kehlet, H.4
  • 21
    • 67249088798 scopus 로고    scopus 로고
    • Non invasive cardiac output monitoring (NICOM compared to minimally invasive monitoring (VIGILEO)
    • Marqué S, Cariou A, Chiche J, Squara P (2009) Non invasive cardiac output monitoring (NICOM) compared to minimally invasive monitoring (VIGILEO). Crit Care 13:R73
    • (2009) Crit Care , vol.13
    • Marqué, S.1    Cariou, A.2    Chiche, J.3    Squara, P.4
  • 24
    • 68849112910 scopus 로고    scopus 로고
    • Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers
    • Squara P, Rotcajg D, Denjean D, Estagnasie P, Brusset A (2009) Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers. Crit Care 13:125
    • (2009) Crit Care , vol.13 , pp. 125
    • Squara, P.1    Rotcajg, D.2    Denjean, D.3    Estagnasie, P.4    Brusset, A.5
  • 25
    • 0038293048 scopus 로고    scopus 로고
    • A computer program for interpreting pulmonary artery catheterization data: Results of the European HEMODYN Resident Study
    • Squara P, Fourquet E, Jacquet L, Broccard A, Uhlig T, Rhodes A, Bakker J, Perret C (2003) A computer program for interpreting pulmonary artery catheterization data: Results of the European HEMODYN Resident Study. Intensive Care Med 29:735-741
    • (2003) Intensive Care Med , vol.29 , pp. 735-741
    • Squara, P.1    Fourquet, E.2    Jacquet, L.3    Broccard, A.4    Uhlig, T.5    Rhodes, A.6    Bakker, J.7    Perret, C.8
  • 27
    • 0030063520 scopus 로고    scopus 로고
    • Clinical usefulness of riskstratified outcome analysis in cardiac surgery in New Jersey
    • Parsonnet V, Bernstein A, Gera M (1996) Clinical usefulness of riskstratified outcome analysis in cardiac surgery in New Jersey. Ann Thorac Surg 61:S8-11
    • (1996) Ann Thorac Surg , vol.61
    • Parsonnet, V.1    Bernstein, A.2    Gera, M.3
  • 28
    • 19644367302 scopus 로고    scopus 로고
    • EuroSCORE predicts intensive care unit stay and costs of open heart surgery
    • Nilsson J, Algotsson L, Höglund P, Lührs C, Brandt J (2004) EuroSCORE predicts intensive care unit stay and costs of open heart surgery. Ann Thorac Surg 78:1528-1534
    • (2004) Ann Thorac Surg , vol.78 , pp. 1528-1534
    • Nilsson, J.1    Algotsson, L.2    Höglund, P.3    Lührs, C.4    Brandt, J.5
  • 29
    • 77951203597 scopus 로고    scopus 로고
    • Greater cardiac response of colloid than saline fluid loading in septic and non-septic critically ill patients with clinical hypovolaemia
    • Trof R, Sukul S, Twisk J, Girbes A, Groeneveld A (2010) Greater cardiac response of colloid than saline fluid loading in septic and non-septic critically ill patients with clinical hypovolaemia. Intensive Care Med 36:697-701
    • (2010) Intensive Care Med , vol.36 , pp. 697-701
    • Trof, R.1    Sukul, S.2    Twisk, J.3    Girbes, A.4    Groeneveld, A.5
  • 30
    • 72449201516 scopus 로고    scopus 로고
    • Tracking changes in cardiac output; methodological considerations for the validation of monitoring devices
    • Squara P, Cecconi C, Singer M, Rhodes A, Chiche J (2009) Tracking changes in cardiac output; methodological considerations for the validation of monitoring devices. Intensive Care Med 35:1801-1808
    • (2009) Intensive Care Med , vol.35 , pp. 1801-1808
    • Squara, P.1    Cecconi, C.2    Singer, M.3    Rhodes, A.4    Chiche, J.5
  • 31
    • 0033931867 scopus 로고    scopus 로고
    • Assessing the accuracy of prediction algorithms for classification: An overview
    • Baldi P, Brunak S, Chauvin Y, Andersen C, Nielsen H (2000) Assessing the accuracy of prediction algorithms for classification: An overview. Bioinformatics 16:412-424
    • (2000) Bioinformatics , vol.16 , pp. 412-424
    • Baldi, P.1    Brunak, S.2    Chauvin, Y.3    Andersen, C.4    Nielsen, H.5
  • 33
    • 74549152648 scopus 로고    scopus 로고
    • A simple physiologic algorithm for managing hemodynamics using stroke volume and stroke volume variation: Physiologic optimization program
    • McGee W (2009) A simple physiologic algorithm for managing hemodynamics using stroke volume and stroke volume variation: Physiologic optimization program. J Intensive Care Med 24:352-360
    • (2009) J Intensive Care Med , vol.24 , pp. 352-360
    • McGee, W.1
  • 35
    • 78650416044 scopus 로고
    • Changes in canine cardiac function and venous return curves by the carotid baroreflex
    • Greene A, Shoukas A (1986) Changes in canine cardiac function and venous return curves by the carotid baroreflex. Am J Physiol 25:1288-1296
    • (1986) Am J Physiol , vol.25 , pp. 1288-1296
    • Greene, A.1    Shoukas, A.2
  • 36
    • 0025597892 scopus 로고
    • Effects of abdominal pressure on venous return: Abdominal vascular zone conditions
    • Takata M, Wise R, Robotham J (1990) Effects of abdominal pressure on venous return: Abdominal vascular zone conditions. J Appl Physiol 69:1961-1972
    • (1990) J Appl Physiol , vol.69 , pp. 1961-1972
    • Takata, M.1    Wise, R.2    Robotham, J.3
  • 38
    • 0027716297 scopus 로고
    • Effects of positive end-expiratory pressure and body position on pressure in the thoracic great veins
    • Fessler H, Brower R, Shapiro E, Permutt S (1993) Effects of positive end-expiratory pressure and body position on pressure in the thoracic great veins. Am Rev Respir Dis 148:1657-1664
    • (1993) Am Rev Respir Dis , vol.148 , pp. 1657-1664
    • Fessler, H.1    Brower, R.2    Shapiro, E.3    Permutt, S.4
  • 39
    • 60449102439 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement in the critically ill patient: Determination of precision of the technique
    • Cecconi M, Dawson D, Grounds R, Rhodes A (2009) Lithium dilution cardiac output measurement in the critically ill patient: Determination of precision of the technique. Intensive Care Med 35:498-504
    • (2009) Intensive Care Med , vol.35 , pp. 498-504
    • Cecconi, M.1    Dawson, D.2    Grounds, R.3    Rhodes, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.