메뉴 건너뛰기




Volumn 62, Issue 3, 2015, Pages 1835-1845

Induction machine insulation health state monitoring based on online switching transient exploitation

Author keywords

AC machines; Condition monitoring; Electric machines; Fault diagnosis; Induction motors; Insulation testing; Motor drives; Pulse width modulated inverters; Rotating machines; Squirrel cage motors

Indexed keywords

ASYNCHRONOUS MACHINERY; CONDITION MONITORING; ELECTRIC DRIVES; ELECTRIC FAULT CURRENTS; ELECTRIC INSULATION; ELECTRIC INSULATION TESTING; ELECTRIC MACHINE THEORY; ELECTRIC MACHINERY; ELECTRIC POWER SYSTEMS; ELECTRIC WINDINGS; FAILURE ANALYSIS; FAULT DETECTION; HEALTH; INDUCTION MOTORS; INSULATION; LOSSES; REPAIR; SIGNAL PROCESSING; SQUIRREL CAGE MOTORS; VARIABLE SPEED DRIVES;

EID: 84923172287     PISSN: 02780046     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIE.2014.2361114     Document Type: Article
Times cited : (75)

References (40)
  • 1
    • 0022206607 scopus 로고
    • Report of large motor reliability survey of industrial and commercial installation, Part i
    • IEEE Committee Report, Jul
    • IEEE Committee Report, "Report of large motor reliability survey of industrial and commercial installation, Part I," IEEE Trans. Ind. Appl., vol. IA-21, no. 4, pp. 853-671, Jul. 1985.
    • (1985) IEEE Trans. Ind. Appl , vol.IA-21 , Issue.4 , pp. 853-671
  • 2
    • 0022204041 scopus 로고
    • Report of large motor reliability survey of industrial and commercial installation, Part II
    • IEEE Committee Report, Jul
    • IEEE Committee Report, "Report of large motor reliability survey of industrial and commercial installation, Part II," IEEE Trans. Ind. Appl., vol. IA-21, no. 4, pp. 865-674, Jul. 1985.
    • (1985) IEEE Trans. Ind. Appl , vol.IA-21 , Issue.4 , pp. 865-674
  • 3
    • 29244467991 scopus 로고    scopus 로고
    • Condition monitoring and fault diagnosis of electrical motors-A review
    • Dec
    • S. Nandi, H. A. Toliyat, and X. Li, "Condition monitoring and fault diagnosis of electrical motors-A review," IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 719-729, Dec. 2005.
    • (2005) IEEE Trans. Energy Convers , vol.20 , Issue.4 , pp. 719-729
    • Nandi, S.1    Toliyat, H.A.2    Li, X.3
  • 4
    • 57749196360 scopus 로고    scopus 로고
    • Advances in diagnostic techniques for induction machines
    • Dec
    • A. Bellini, F. Filippetti, C. Tassoni, and G.-A. Capolino, "Advances in diagnostic techniques for induction machines," IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4109-4126, Dec. 2008.
    • (2008) IEEE Trans. Ind. Electron , vol.55 , Issue.12 , pp. 4109-4126
    • Bellini, A.1    Filippetti, F.2    Tassoni, C.3    Capolino, G.-A.4
  • 5
    • 0036817818 scopus 로고    scopus 로고
    • Advancements during the past quarter century in on-line monitoring of motor and generator winding insulation
    • Oct
    • G. C. Stone, "Advancements during the past quarter century in on-line monitoring of motor and generator winding insulation," IEEE Trans. Dielectr. Electr. Insul., vol. 9, no. 5, pp. 746-751, Oct. 2002.
    • (2002) IEEE Trans. Dielectr. Electr. Insul , vol.9 , Issue.5 , pp. 746-751
    • Stone, G.C.1
  • 6
    • 13844254144 scopus 로고    scopus 로고
    • Recent important changes in IEEE motor and generator winding insulation diagnostic testing standards
    • Jan./Feb
    • G. C. Stone, "Recent important changes in IEEE motor and generator winding insulation diagnostic testing standards," IEEE Trans. Ind. Appl., vol. 41, no. 1, pp. 91-100, Jan./Feb. 2005.
    • (2005) IEEE Trans. Ind. Appl , vol.41 , Issue.1 , pp. 91-100
    • Stone, G.C.1
  • 7
    • 81255197111 scopus 로고    scopus 로고
    • PD activity inside random wire wound motor stator insulation and early failures: A case study analysis
    • F. Guastavino, A. Dardano, E. Torello, and G. F. Massa, "PD activity inside random wire wound motor stator insulation and early failures: A case study analysis," in Proc. IEEE SDEMPED, 2011, pp. 283-287.
    • (2011) Proc. IEEE SDEMPED , pp. 283-287
    • Guastavino, F.1    Dardano, A.2    Torello, E.3    Massa, G.F.4
  • 8
    • 41949093228 scopus 로고    scopus 로고
    • An advanced stator winding insulation quality assessment technique for inverterfed machines
    • Mar./Apr
    • J. Yang, J. Cho, S. B. Lee, J.-Y. Yoo, and H. D. Kim, "An advanced stator winding insulation quality assessment technique for inverterfed machines," IEEE Trans. Ind. Appl., vol. 44, no. 2, pp. 555-564, Mar./Apr. 2008.
    • (2008) IEEE Trans. Ind. Appl , vol.44 , Issue.2 , pp. 555-564
    • Yang, J.1    Cho, J.2    Lee, S.B.3    Yoo, J.-Y.4    Kim, H.D.5
  • 10
    • 57749177424 scopus 로고    scopus 로고
    • A survey on testing and monitoring methods for stator insulation systems of low-voltage induction machines focusing on turn insulation problems
    • Dec
    • S. Grubic, J. M. Aller, B. Lu, and T. G. Habetler, "A survey on testing and monitoring methods for stator insulation systems of low-voltage induction machines focusing on turn insulation problems," IEEE Trans. Ind. Electron., vol. 55, no. 12, pp. 4127-4136, Dec. 2008.
    • (2008) IEEE Trans. Ind. Electron , vol.55 , Issue.12 , pp. 4127-4136
    • Grubic, S.1    Aller, J.M.2    Lu, B.3    Habetler, T.G.4
  • 11
    • 84877748087 scopus 로고    scopus 로고
    • Electrical aging of the insulation of low-voltage machines: Model definition and test with the design of experiments
    • Sep
    • N. Lahoud, J. Faucher, D. Malec, and P. Maussion, "Electrical aging of the insulation of low-voltage machines: Model definition and test with the design of experiments," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4147-4155, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron , vol.60 , Issue.9 , pp. 4147-4155
    • Lahoud, N.1    Faucher, J.2    Malec, D.3    Maussion, P.4
  • 12
    • 81255197113 scopus 로고    scopus 로고
    • Electrical ageing modeling of the insulation of low voltage rotating machines fed by inverters with the design of experiments (DoE) method
    • N. Lahoud, J. Faucher, D. Malec, and P. Maussion, "Electrical ageing modeling of the insulation of low voltage rotating machines fed by inverters with the design of experiments (DoE) method," in Proc. IEEE SDEMPED, 2011, pp. 272-277.
    • (2011) Proc. IEEE SDEMPED , pp. 272-277
    • Lahoud, N.1    Faucher, J.2    Malec, D.3    Maussion, P.4
  • 13
    • 0033898972 scopus 로고    scopus 로고
    • Electrical stress and failure mechanism of the winding insulation in PWMinverter- fed low-voltage induction motors
    • Apr
    • M. Kaufhold, H. Aninger, M. Berth, J. Speck, and M. Eberhardt, "Electrical stress and failure mechanism of the winding insulation in PWMinverter- fed low-voltage induction motors," IEEE Trans. Ind. Electron., vol. 47, no. 2, pp. 396-402, Apr. 2000.
    • (2000) IEEE Trans. Ind. Electron , vol.47 , Issue.2 , pp. 396-402
    • Kaufhold, M.1    Aninger, H.2    Berth, M.3    Speck, J.4    Eberhardt, M.5
  • 14
    • 84877760278 scopus 로고    scopus 로고
    • Wound-rotor induction generator inter-turn short-circuits diagnosis using a new digital neural network
    • Sep
    • S. Toma, L. Capocchi, and G.-A. Capolino, "Wound-rotor induction generator inter-turn short-circuits diagnosis using a new digital neural network," IEEE Trans. Ind. Electron., vol. 60, no. 9, pp. 4043-4052, Sep. 2013.
    • (2013) IEEE Trans. Ind. Electron , vol.60 , Issue.9 , pp. 4043-4052
    • Toma, S.1    Capocchi, L.2    Capolino, G.-A.3
  • 15
    • 81255138809 scopus 로고    scopus 로고
    • Wound-rotor induction generator short-circuit fault classification using a new neural network based on digital data
    • L. Capocchi, S. Toma, G.-A. Capolino, F. Fnaiech, and A. Yazidi, "Wound-rotor induction generator short-circuit fault classification using a new neural network based on digital data," in Proc. IEEE SDEMPED, 2011, pp. 638-644.
    • (2011) Proc. IEEE SDEMPED , pp. 638-644
    • Capocchi, L.1    Toma, S.2    Capolino, G.-A.3    Fnaiech, F.4    Yazidi, A.5
  • 16
    • 33947399741 scopus 로고    scopus 로고
    • Adaptive neural fuzzy inference system for the detection of inter-turn insulation and bearing wear faults in induction motor
    • Feb
    • M. S. Ballal, Z. J. Khan, H. M. Suryawanshi, and R. L. Sonolikar, "Adaptive neural fuzzy inference system for the detection of inter-turn insulation and bearing wear faults in induction motor," IEEE Trans. Ind. Electron., vol. 54, no. 1, pp. 250-258, Feb. 2007.
    • (2007) IEEE Trans. Ind. Electron , vol.54 , Issue.1 , pp. 250-258
    • Ballal, M.S.1    Khan, Z.J.2    Suryawanshi, H.M.3    Sonolikar, R.L.4
  • 17
    • 84876212421 scopus 로고    scopus 로고
    • Inter-turn fault detection in PM synchronous machines by physics-based back electromotive force estimation
    • Aug
    • A. Sarikhani and O. A. Mohammed, "Inter-turn fault detection in PM synchronous machines by physics-based back electromotive force estimation," IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3472-3484, Aug. 2013.
    • (2013) IEEE Trans. Ind. Electron , vol.60 , Issue.8 , pp. 3472-3484
    • Sarikhani, A.1    Mohammed, O.A.2
  • 18
    • 78751498247 scopus 로고    scopus 로고
    • Inter-turn fault diagnosis of PM synchronous generator for variable speed wind applications using floating-space-vector
    • A. Sarikhani, B. Mirafzal, and O. Mohammed, "Inter-turn fault diagnosis of PM synchronous generator for variable speed wind applications using floating-space-vector," in Proc. IEEE IECON, 2010, pp. 2628-2633.
    • (2010) Proc. IEEE IECON , pp. 2628-2633
    • Sarikhani, A.1    Mirafzal, B.2    Mohammed, O.3
  • 19
    • 84876237757 scopus 로고    scopus 로고
    • Using only the dc current information to detect stator turn faults in automotive claw-pole generators
    • Aug
    • S. Cheng and T. G. Habetler, "Using only the dc current information to detect stator turn faults in automotive claw-pole generators," IEEE Trans. Ind. Electron., vol. 60, no. 8, pp. 3462-3471, Aug. 2013.
    • (2013) IEEE Trans. Ind. Electron , vol.60 , Issue.8 , pp. 3462-3471
    • Cheng, S.1    Habetler, T.G.2
  • 20
    • 79954523498 scopus 로고    scopus 로고
    • An impedance identification approach to sensitive detection and location of stator turn-to-turn faults in a closed-loop multiple-motor drive
    • May
    • S. Cheng, P. Zhang, and T. G. Habetler, "An impedance identification approach to sensitive detection and location of stator turn-to-turn faults in a closed-loop multiple-motor drive," IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1545-1554, May 2011.
    • (2011) IEEE Trans. Ind. Electron , vol.58 , Issue.5 , pp. 1545-1554
    • Cheng, S.1    Zhang, P.2    Habetler, T.G.3
  • 21
    • 74349112666 scopus 로고    scopus 로고
    • A new method to detect stator turn-toturn faults in a closed-loop multiple-motor drive system
    • S. Cheng and T. G. Habetler, "A new method to detect stator turn-toturn faults in a closed-loop multiple-motor drive system," in Proc. IEEE SDEMPED, 2009, pp. 1-6.
    • (2009) Proc. IEEE SDEMPED , pp. 1-6
    • Cheng, S.1    Habetler, T.G.2
  • 22
    • 79956284921 scopus 로고    scopus 로고
    • Simple online fault detecting scheme for short-circuited turn in a PMSM through current harmonic monitoring
    • Jun
    • K.-H. Kim, "Simple online fault detecting scheme for short-circuited turn in a PMSM through current harmonic monitoring," IEEE Trans. Ind. Electron., vol. 58, no. 6, pp. 2565-2568, Jun. 2011.
    • (2011) IEEE Trans. Ind. Electron , vol.58 , Issue.6 , pp. 2565-2568
    • Kim, K.-H.1
  • 25
    • 0030106079 scopus 로고    scopus 로고
    • Application of partial discharge testing to motor and generator stator winding maintenance
    • Mar./Apr
    • G. C. Stone, H. G. Sedding, and M. J. Costello, "Application of partial discharge testing to motor and generator stator winding maintenance," IEEE Trans. Ind. Appl., vol. 32, no. 2, pp. 459-464, Mar./Apr. 1996.
    • (1996) IEEE Trans. Ind. Appl , vol.32 , Issue.2 , pp. 459-464
    • Stone, G.C.1    Sedding, H.G.2    Costello, M.J.3
  • 26
    • 1642444779 scopus 로고    scopus 로고
    • New practices for partial discharge detection and localization in large rotating machines
    • Dec
    • A. Kheirmand, M. Leijon, and S. M. Gubanski, "New practices for partial discharge detection and localization in large rotating machines," IEEE Trans. Dielectr. Electr. Insul., vol. 10, no. 6, pp. 1042-1052, Dec. 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul , vol.10 , Issue.6 , pp. 1042-1052
    • Kheirmand, A.1    Leijon, M.2    Gubanski, S.M.3
  • 27
    • 1842477108 scopus 로고    scopus 로고
    • Measures and technologies to enhance the insulation condition monitoring of large electrical machines
    • Feb
    • J. K. Nelson and S. Azizi-Ghannad, "Measures and technologies to enhance the insulation condition monitoring of large electrical machines," IEEE Trans. Dielectr. Electr. Insul., vol. 11, no. 1, pp. 102-112, Feb. 2004.
    • (2004) IEEE Trans. Dielectr. Electr. Insul , vol.11 , Issue.1 , pp. 102-112
    • Nelson, J.K.1    Azizi-Ghannad, S.2
  • 28
    • 84863138051 scopus 로고    scopus 로고
    • Experimental evaluation of using the surge PD test as a predictive maintenance tool for monitoring turn insulation quality in random wound ac motor stator windings
    • Feb
    • J. Yang et al., "Experimental evaluation of using the surge PD test as a predictive maintenance tool for monitoring turn insulation quality in random wound ac motor stator windings," IEEE Trans. Dielectr. Electr. Insul., vol. 19, no. 1, pp. 53-60, Feb. 2012.
    • (2012) IEEE Trans Dielectr. Electr. Insul , vol.19 , Issue.1 , pp. 53-60
    • Yang, J.1
  • 29
    • 77957899770 scopus 로고    scopus 로고
    • On-line capacitance and dissipation factor monitoring of ac stator insulation
    • Oct
    • K. Younsi et al., "On-line capacitance and dissipation factor monitoring of ac stator insulation," IEEE Trans. Dielectr. Electr. Insul., vol. 17, no. 5, pp. 1441-1452, Oct. 2010.
    • (2010) IEEE Trans. Dielectr. Electr. Insul , vol.17 , Issue.5 , pp. 1441-1452
    • Younsi, K.1
  • 30
    • 33746350459 scopus 로고    scopus 로고
    • An online groundwall and phase-to-phase insulation quality assessment technique for acmachine stator windings
    • Jul./Aug
    • S.-B. Lee, J. Yang, K. Younsi, and R. M. Bharadwaj, "An online groundwall and phase-to-phase insulation quality assessment technique for acmachine stator windings," IEEE Trans. Ind. Appl., vol. 42, no. 4, pp. 946- 957, Jul./Aug. 2006.
    • (2006) IEEE Trans. Ind. Appl , vol.42 , Issue.4 , pp. 946-957
    • Lee, S.-B.1    Yang, J.2    Younsi, K.3    Bharadwaj, R.M.4
  • 31
    • 78650093412 scopus 로고    scopus 로고
    • A new concept for online surge testing for the detection of winding insulation deterioration
    • S. Grubic, T. G. Habetler, and J. Restrepo, "A new concept for online surge testing for the detection of winding insulation deterioration," in Proc. IEEE ECCE, 2010, pp. 2747-2754.
    • (2010) Proc. IEEE ECCE , pp. 2747-2754
    • Grubic, S.1    Habetler, T.G.2    Restrepo, J.3
  • 32
    • 84877881090 scopus 로고    scopus 로고
    • Online surge testing applied to an induction machine with emulated insulation breakdown
    • May/Jun
    • S. Grubic, J. Restrepo, and T. G. Habetler, "Online surge testing applied to an induction machine with emulated insulation breakdown," IEEE Trans. Ind. Appl., vol. 49, no. 3, pp. 1358-1366, May/Jun. 2013.
    • (2013) IEEE Trans. Ind. Appl , vol.49 , Issue.3 , pp. 1358-1366
    • Grubic, S.1    Restrepo, J.2    Habetler, T.G.3
  • 33
    • 84891104222 scopus 로고    scopus 로고
    • Exploitation of induction machine's high-frequency behavior for online insulation monitoring
    • P. Nussbaumer, M. A. Vogelsberger, and T. M. Wolbank, "Exploitation of induction machine's high-frequency behavior for online insulation monitoring," in Proc. IEEE SDEMPED, 2013, pp. 579-585.
    • (2013) Proc. IEEE SDEMPED , pp. 579-585
    • Nussbaumer, P.1    Vogelsberger, M.A.2    Wolbank, T.M.3
  • 34
    • 0031143193 scopus 로고    scopus 로고
    • Interaction of drive modulation and cable parameters on ac motor transients
    • May/Jun
    • R. J. Kerkman, D. Leggate, and G. L. Skibinski, "Interaction of drive modulation and cable parameters on ac motor transients," IEEE Trans. Ind. Appl., vol. 33, no. 3, pp. 722-731, May/Jun. 1997.
    • (1997) IEEE Trans. Ind. Appl , vol.33 , Issue.3 , pp. 722-731
    • Kerkman, R.J.1    Leggate, D.2    Skibinski, G.L.3
  • 35
    • 0036079591 scopus 로고    scopus 로고
    • Adverse effects in voltage source inverter-fed drive systems
    • Z. Peroutka and V. Kus, "Adverse effects in voltage source inverter-fed drive systems," in Proc. IEEE APEC, 2002, pp. 557-563.
    • (2002) Proc. IEEE APEC , pp. 557-563
    • Peroutka, Z.1    Kus, V.2
  • 36
    • 84879351193 scopus 로고    scopus 로고
    • Separation of disturbing influences on induction machine's high-frequency behavior to ensure accurate insulation condition monitoring
    • P. Nussbaumer, T. M. Wolbank, and M. A. Vogelsberger, "Separation of disturbing influences on induction machine's high-frequency behavior to ensure accurate insulation condition monitoring," in Proc. IEEE APEC, 2013, pp. 1158-1163.
    • (2013) Proc. IEEE APEC , pp. 1158-1163
    • Nussbaumer, P.1    Wolbank, T.M.2    Vogelsberger, M.A.3
  • 37
    • 70449393052 scopus 로고    scopus 로고
    • Robust diagnostics of stator insulation based on high frequency resonances measurements
    • Oct
    • F. Perisse, D. Mercier, E. Lefevre, and D. Roger, "Robust diagnostics of stator insulation based on high frequency resonances measurements," IEEE Trans. Dielectr. Electr. Insul., vol. 16, no. 5, pp. 1496-1502, Oct. 2009.
    • (2009) IEEE Trans. Dielectr. Electr. Insul , vol.16 , Issue.5 , pp. 1496-1502
    • Perisse, F.1    Mercier, D.2    Lefevre, E.3    Roger, D.4
  • 38
    • 84873661273 scopus 로고    scopus 로고
    • Turn-to-turn capacitance variations correlated to PDIV for ac motors monitoring
    • Feb
    • S. Savin, S. Ait-Amar, and D. Roger, "Turn-to-turn capacitance variations correlated to PDIV for ac motors monitoring," IEEE Trans. Dielectr. Electr. Insul., vol. 20, no. 1, pp. 34-41, Feb. 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.1 , pp. 34-41
    • Savin, S.1    Ait-Amar, S.2    Roger, D.3
  • 39
    • 80054076925 scopus 로고    scopus 로고
    • A simulation method to predict the turn-to-turn voltage spikes in aPWMfed motor winding
    • Oct
    • V. Mihaila, S. Duchesne, and D. Roger, "A simulation method to predict the turn-to-turn voltage spikes in aPWMfed motor winding," IEEE Trans. Dielectr. Electr. Insul., vol. 18, no. 5, pp. 1609-1615, Oct. 2011.
    • (2011) IEEE Trans. Dielectr. Electr. Insul , vol.18 , Issue.5 , pp. 1609-1615
    • Mihaila, V.1    Duchesne, S.2    Roger, D.3
  • 40
    • 77957899991 scopus 로고    scopus 로고
    • Behavior of machine insulation systems subjected to accelerated thermal aging test
    • Oct
    • M. Farahani, E. Gockenbach, H. Borsi, K. Schäfer, and M. Kaufhold, "Behavior of machine insulation systems subjected to accelerated thermal aging test," IEEE Trans. Dielectr. Electr. Insul., vol. 17, no. 5, pp. 1364- 1372, Oct. 2010.
    • (2010) IEEE Trans. Dielectr. Electr. Insul , vol.17 , Issue.5 , pp. 1364-1372
    • Farahani, M.1    Gockenbach, E.2    Borsi, H.3    Schäfer, K.4    Kaufhold, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.