메뉴 건너뛰기




Volumn 11, Issue 1, 2004, Pages 102-112

Measures and Technologies to Enhance the Insulation Condition Monitoring of Large Electrical Machines

Author keywords

Acoustic probes; Electrical machines; Fractal dimension; Insulation aging; Life extension; On line monitoring; Partial discharge

Indexed keywords

ACOUSTIC WAVES; DATA REDUCTION; DEGRADATION; ELECTRIC POTENTIAL; PARTIAL DISCHARGES; QUALITY CONTROL; SIGNAL INTERFERENCE; TURBOMACHINERY;

EID: 1842477108     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2004.1266323     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 0030106079 scopus 로고    scopus 로고
    • Application of partial discharge testing to motor and generator stator winding maintenance
    • G. C. Stone, H. G. Sedding, and M. J. Costello, "Application of partial discharge testing to motor and generator stator winding maintenance", IEEE Trans. Industr. Appl., Vol. 32, pp. 459-464, 1996.
    • (1996) IEEE Trans. Industr. Appl. , vol.32 , pp. 459-464
    • Stone, G.C.1    Sedding, H.G.2    Costello, M.J.3
  • 2
    • 0026881875 scopus 로고
    • Discrimination of partial discharge patterns using a neural network
    • N. Hozumi, T. Okamoto and T. Imajo, "Discrimination of partial discharge patterns using a neural network", IEEE Trans. Electr. Insul., Vol. 27, pp. 550-556, 1992.
    • (1992) IEEE Trans. Electr. Insul. , vol.27 , pp. 550-556
    • Hozumi, N.1    Okamoto, T.2    Imajo, T.3
  • 3
    • 1842551608 scopus 로고
    • Latest experiences with partial discharge monitoring on rotating electrical machines
    • Graz, Austria
    • R. Schuler, J. Ruhe, and T. Fügulister, "Latest experiences with partial discharge monitoring on rotating electrical machines", 9th Int. Symp. HV Eng., Graz, Austria, pp. 5665/1-4, Vol. 5, 1995.
    • (1995) 9th Int. Symp. HV Eng. , vol.5 , pp. 5665
    • Schuler, R.1    Ruhe, J.2    Fügulister, T.3
  • 5
    • 0029717726 scopus 로고    scopus 로고
    • An automated system for measurement of partial discharges in HV generator insulation utilizing a conventional oscilloscope
    • S. Azizi-Ghannad and J. K. Nelson, "An automated system for measurement of partial discharges in HV generator insulation utilizing a conventional oscilloscope", IEEE Int. Symp. on Electr. Insul., pp. 243-246, 1996.
    • (1996) IEEE Int. Symp. on Electr. Insul. , pp. 243-246
    • Azizi-Ghannad, S.1    Nelson, J.K.2
  • 6
    • 1842447069 scopus 로고    scopus 로고
    • Partial discharge on-line testing of turbine driven generator stator windings
    • C.V. Maughan, "Partial discharge on-line testing of turbine driven generator stator windings", EPRI Report 1001209, 2000.
    • (2000) EPRI Report 1001209
    • Maughan, C.V.1
  • 7
    • 0000486840 scopus 로고
    • Assessment of Deterioration in Epoxy-Mica Insulation
    • Y. J. Kim and J. K. Nelson, "Assessment of Deterioration in Epoxy-Mica Insulation", IEEE Trans. Electr. Insul., Vol. 27, pp. 1026-1039, 1992.
    • (1992) IEEE Trans. Electr. Insul. , vol.27 , pp. 1026-1039
    • Kim, Y.J.1    Nelson, J.K.2
  • 9
    • 0031674723 scopus 로고    scopus 로고
    • Partial discharge Part XXV: Calibration of PD measurements for motor and generator windings - Why it can't be done
    • G. C. Stone, "Partial discharge Part XXV: Calibration of PD measurements for motor and generator windings - why it can't be done", IEEE Electr. Insul. Mag., Vol. 14, No. 1, pp. 9-12, 1998.
    • (1998) IEEE Electr. Insul. Mag. , vol.14 , Issue.1 , pp. 9-12
    • Stone, G.C.1
  • 10
    • 0004083386 scopus 로고
    • VCH Verlagsgesellschaft mbh, D-6940, Wienheim, Germany
    • H. G. Schuster, Deterministic Chaos, VCH Verlagsgesellschaft mbh, D-6940, Wienheim, Germany, 1989.
    • (1989) Deterministic Chaos
    • Schuster, H.G.1
  • 12
    • 0001077204 scopus 로고
    • Stochastic properties of Trichel-pulse corona: A non-Markovian random point process
    • R. J. Van Brunt and S. V. Kulkarni, "Stochastic properties of Trichel-pulse corona: A non-Markovian random point process", Phys. Rev. A, Vol. 42, pp 4908-4932, 1990.
    • (1990) Phys. Rev. A , vol.42 , pp. 4908-4932
    • Van Brunt, R.J.1    Kulkarni, S.V.2
  • 14
    • 0021476651 scopus 로고
    • Application of partial discharge testing to hydrogenerator maintenance
    • M. Kurtz, J. F. Lyles and G. C. Stone, "Application of partial discharge testing to hydrogenerator maintenance", IEEE Trans. Power App. and Syst., Vol. 103, pp. 2148-2157, 1984.
    • (1984) IEEE Trans. Power App. and Syst. , vol.103 , pp. 2148-2157
    • Kurtz, M.1    Lyles, J.F.2    Stone, G.C.3
  • 16
    • 1842447066 scopus 로고    scopus 로고
    • A basis for the prediction of insulation failure in rotating machines
    • J. K. Nelson and H. Li, "A basis for the prediction of insulation failure in rotating machines", EPRI Final Report # TR-110861, 1998.
    • (1998) EPRI Final Report # TR-110861 , vol.TR-110861
    • Nelson, J.K.1    Li, H.2
  • 17
    • 0029356716 scopus 로고
    • PD detection and localization by means of acoustic measurements on hydrogenerator stator bars
    • R. F. Bozzo, J. Guastavino and C. Guerra, "PD detection and localization by means of acoustic measurements on hydrogenerator stator bars", IEEE Trans. Dielectr. Electr. Insul., Vol. 2, pp 660-666, 1995.
    • (1995) IEEE Trans. Dielectr. Electr. Insul. , vol.2 , pp. 660-666
    • Bozzo, R.F.1    Guastavino, J.2    Guerra, C.3
  • 19
    • 0033353175 scopus 로고    scopus 로고
    • Partial discharge source location by acoustic emission analysis in electric machine stators
    • Z. A. Bukhala, and J. K. Nelson, "Partial discharge source location by acoustic emission analysis in electric machine stators", Materials Evaluation., Vol. 57, pp. 1083-1088, 1999.
    • (1999) Materials Evaluation. , vol.57 , pp. 1083-1088
    • Bukhala, Z.A.1    Nelson, J.K.2
  • 20
    • 1842499291 scopus 로고
    • Discussion on "An acoustic diagnostic technique for use with electric machine insulation"
    • J. E. Timperley, Discussion on "An acoustic diagnostic technique for use with electric machine insulation", IEEE Trans. Dielectr. Electr. Insul., Vol. 1, pp. 1194-1195, 1994.
    • (1994) IEEE Trans. Dielectr. Electr. Insul. , vol.1 , pp. 1194-1195
    • Timperley, J.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.