A simulation method to predict the turn-to-turn voltage spikes in a PWM fed motor winding

Author keywords

equivalent circuit; Motor winding; simulation tool; steep fronted pulse; voltage stress

Indexed keywords

HIGH FREQUENCY HF; HIGH RELIABILITY; MOTOR WINDING; MOTOR WINDINGS; NUMERICAL SIMULATION METHOD; PWM INVERTER; SIMULATION METHODS; SIMULATION PACKAGES; SIMULATION RESULT; SIMULATION TOOL; STATOR SLOT; STEEP FRONTED PULSE; VOLTAGE DISTRIBUTION; VOLTAGE SPIKES; VOLTAGE STRESS;

EID: 80054076925     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2011.6032831     Document Type: Conference Paper
Times cited : (71)

References (21)
  • 1
    • 0033898972 scopus 로고    scopus 로고
    • Electrical stress and failure mechanism of the winding insulation in PWM-inverter-fed low-voltage induction motors
    • M. Kaufhold, H. Auinger, M. Berth, J. Speck, and M. Eberhardt, "Electrical stress and failure mechanism of the winding insulation in PWM-inverter-fed low-voltage induction motors", IEEE Trans. Industrial Electronics, Vol. 47, No. 2, pp. 396-402, 2000.
    • (2000) IEEE Trans. Industrial Electronics , vol.47 , Issue.2 , pp. 396-402
    • Kaufhold, M.1    Auinger, H.2    Berth, M.3    Speck, J.4    Eberhardt, M.5
  • 2
    • 0030247001 scopus 로고    scopus 로고
    • Failure mechanism of the interturn insulation of low voltage electric machines fed by pulsecontrolled inverters
    • M. Kaufhold, G. Borner, M. Eberhardt, and J. Speck, "Failure mechanism of the interturn insulation of low voltage electric machines fed by pulsecontrolled inverters", IEEE Electr. lnsul. Mag., Vol. 12, No. 5, pp. 9-16, 1996.
    • (1996) IEEE Electr. lnsul. Mag. , vol.12 , Issue.5 , pp. 9-16
    • Kaufhold, M.1    Borner, G.2    Eberhardt, M.3    Speck, J.4
  • 5
    • 69249174459 scopus 로고    scopus 로고
    • Reliability and statistical lifetime-prognosis of motor winding insulation in low-voltage power drive systems
    • F. Schemmel, K. Bauer, and M. Kaufhold, "Reliability and statistical lifetime-prognosis of motor winding insulation in low-voltage power drive systems", IEEE Electr. lnsul. Mag., Vol. 25, No. 4, pp. 6-13, 2009.
    • (2009) IEEE Electr. lnsul. Mag. , vol.25 , Issue.4 , pp. 6-13
    • Schemmel, F.1    Bauer, K.2    Kaufhold, M.3
  • 7
    • 0032120373 scopus 로고    scopus 로고
    • Effect of surge voltage risetime on the insulation of low-voltage machines fed by PWM converters
    • M. Melfi, A. M. J. Sung, S. Bell, and G. L. Skibinski, "Effect of surge voltage risetime on the insulation of low-voltage machines fed by PWM converters", IEEE Trans. Ind. Appl., Vol. 34, No.4, pp. 766-775, 1998.
    • (1998) IEEE Trans. Ind. Appl. , vol.34 , Issue.4 , pp. 766-775
    • Melfi, M.1    Sung, A.M.J.2    Bell, S.3    Skibinski, G.L.4
  • 8
    • 0031276106 scopus 로고    scopus 로고
    • Failure mechanism of winding insulations in inverter-fed motors
    • W. Yin, "Failure mechanism of winding insulations in inverter-fed motors", IEEE Electr. Insul. Mag., Vol. 13, No. 6, pp. 18-23, 1997.
    • (1997) IEEE Electr. Insul. Mag. , vol.13 , Issue.6 , pp. 18-23
    • Yin, W.1
  • 9
    • 0037300762 scopus 로고    scopus 로고
    • Development of a new off-line test procedure for low voltage rotating machines fed by adjustable speed drives (ASD)
    • P. Bidan, T. Lebey, and C. Neacsu, "Development of a new off-line test procedure for low voltage rotating machines fed by adjustable speed drives (ASD)", IEEE Trans. Dielectr. Electr. Insul., Vol. 10, No. 1, pp. 168-175, 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , Issue.1 , pp. 168-175
    • Bidan, P.1    Lebey, T.2    Neacsu, C.3
  • 10
    • 0030217469 scopus 로고    scopus 로고
    • Existence of partial discharges in low-voltage induction machines supplied by PWM drives
    • A. Mbaye, F. Grigorescu, T. Lebey, and B. Ai, "Existence of partial discharges in low-voltage induction machines supplied by PWM drives", IEEE Trans. Dielectr. Electr. Insul., Vol. 3, No.4, pp. 554-560, 1996.
    • (1996) IEEE Trans. Dielectr. Electr. Insul. , vol.3 , Issue.4 , pp. 554-560
    • Mbaye, A.1    Grigorescu, F.2    Lebey, T.3    Ai, B.4
  • 11
  • 12
    • 0030107454 scopus 로고    scopus 로고
    • Calculation of machine winding electrical parameters at High Frequencies for switching transient studies
    • J. L. Guardado and K. J. Cornick, "Calculation of machine winding electrical parameters at High Frequencies for switching transient studies", IEEE Trans. Energy Conversion, Vol. 11, No.1, pp. 33-40, 1996.
    • (1996) IEEE Trans. Energy Conversion , vol.11 , Issue.1 , pp. 33-40
    • Guardado, J.L.1    Cornick, K.J.2
  • 13
    • 0030682987 scopus 로고    scopus 로고
    • An equivalent circuit for calculation of interturn voltage distribution of stator windings in the presence of slot discharges
    • Seoul, South Korea
    • S. Islam and G. Ledwich, "An equivalent circuit for calculation of interturn voltage distribution of stator windings in the presence of slot discharges", IEEE 5th Int'l. Conf. Properties and Applications of Dielectr. Materials, Seoul, South Korea, pp. 507-510, 1997.
    • (1997) IEEE 5th Int'l. Conf. Properties and Applications of Dielectr. Materials , pp. 507-510
    • Islam, S.1    Ledwich, G.2
  • 14
    • 59649085883 scopus 로고    scopus 로고
    • Determination of parameters in the universal Induction Motor model
    • B. Mirafzal, G. L. Skibinski, and R. M. Tallam, "Determination of parameters in the universal Induction Motor model", IEEE Trans. Ind. Appl., Vol. 45, No.1, pp. 142-151, 2009.
    • (2009) IEEE Trans. Ind. Appl. , vol.45 , Issue.1 , pp. 142-151
    • Mirafzal, B.1    Skibinski, G.L.2    Tallam, R.M.3
  • 15
    • 35348877535 scopus 로고    scopus 로고
    • A new method for AC machine turn insulation diagnostic based on High Frequency resonances
    • F. Perisse, P. Werynski, and D. Roger, "A new method for AC machine turn insulation diagnostic based on High Frequency resonances", IEEE Trans. Dielectr. Electr. Insul., Vol. 14, No. 5, pp. 1308-1315, 2007.
    • (2007) IEEE Trans. Dielectr. Electr. Insul. , vol.14 , Issue.5 , pp. 1308-1315
    • Perisse, F.1    Werynski, P.2    Roger, D.3
  • 16
    • 0032761530 scopus 로고    scopus 로고
    • Predicting the transient effects of PWM voltage waveform on the stator windings of random wound induction motors
    • G. Suresh, H. A. Toliyat, D. A. Rendusara, and P. N. Enjeti, "Predicting the transient effects of PWM voltage waveform on the stator windings of random wound induction motors", IEEE Trans. Power Electronics, Vol. 14, No. 1, pp. 23-30, 1999.
    • (1999) IEEE Trans. Power Electronics , vol.14 , Issue.1 , pp. 23-30
    • Suresh, G.1    Toliyat, H.A.2    Rendusara, D.A.3    Enjeti, P.N.4
  • 17
    • 51649105715 scopus 로고    scopus 로고
    • Modeling of non-salient PM synchronous machines under stator winding inter-turn fault condition: Dynamic model-FEM model
    • Arlington, USA
    • B. Vaseghi, B. Nahid-Mobarakeh, N. Takorabet, and F. Meibody-Tabar, "Modeling of non-salient PM synchronous machines under stator winding inter-turn fault condition: Dynamic model-FEM model", IEEE Vehicle Power and Propulsion Conf. (VPPC), Arlington, USA, pp. 635-640, 2007.
    • (2007) IEEE Vehicle Power and Propulsion Conf. (VPPC) , pp. 635-640
    • Vaseghi, B.1    Nahid-Mobarakeh, B.2    Takorabet, N.3    Meibody-Tabar, F.4
  • 18
    • 0035072125 scopus 로고    scopus 로고
    • Transient voltage distribution in inverter fed motor windings: Experimental study and modeling
    • P. Bidan, T. Lebey, G. Montseny, C. Neacsu, and J. Saint-Michel, "Transient voltage distribution in inverter fed motor windings: Experimental study and modeling", IEEE Trans. Power Electronics, Vol. 16, No. 1, pp. 92-100, 2001.
    • (2001) IEEE Trans. Power Electronics , vol.16 , Issue.1 , pp. 92-100
    • Bidan, P.1    Lebey, T.2    Montseny, G.3    Neacsu, C.4    Saint-Michel, J.5
  • 19
    • 1542285820 scopus 로고    scopus 로고
    • Analysis of the voltage distribution in a motor stator winding subjected to steep-fronted surge voltages by means of a multiconductor lossy transmission line model
    • C. Petrarca, A. Maffucci, V. Tucci, and M. Vitelli, "Analysis of the voltage distribution in a motor stator winding subjected to steep-fronted surge voltages by means of a multiconductor lossy transmission line model", IEEE Trans. Energy Conversion, Vol. 19, No. 1, pp. 7-17, 2004.
    • (2004) IEEE Trans. Energy Conversion , vol.19 , Issue.1 , pp. 7-17
    • Petrarca, C.1    Maffucci, A.2    Tucci, V.3    Vitelli, M.4
  • 20
    • 50649110472 scopus 로고    scopus 로고
    • Frequencydomain model for calculation of voltage distribution through random wound coils and its interaction with stray capacitances
    • J. M. Martinez-Tarifa, H. Amaris-Duarte, and J. Sanz-Feito, "Frequencydomain model for calculation of voltage distribution through random wound coils and its interaction with stray capacitances", IEEE Trans. Energy Conversion, Vol. 23, No. 3, pp. 742-751, 2008.
    • (2008) IEEE Trans. Energy Conversion , vol.23 , Issue.3 , pp. 742-751
    • Martinez-Tarifa, J.M.1    Amaris-Duarte, H.2    Sanz-Feito, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.