Volumn 1381, Issue , 2015, Pages 149-159

Enantiomers separation by nano-liquid chromatography: Use of a novel sub-2μm vancomycin silica hydride stationary phase

Author keywords

Enantiomers; Herbicides; Nano liquid chromatography; Non steroidal anti inflammatory drugs; Sub 2 m silica hydride particles; Vancomycin stationary phase

Indexed keywords

CAPILLARITY; CHIRALITY; EFFICIENCY; ENANTIOMERS; HERBICIDES; HYDRIDES; LIQUID CHROMATOGRAPHY; LIQUIDS; WEED CONTROL;

EID: 84922827109     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2015.01.015     Document Type: Article
Times cited : (36)

References (44)
  • 1
    • 84889602021 scopus 로고    scopus 로고
    • Importance of instrumentation for fast liquid chromatography in pharmaceutical analysis
    • Fekete S., Kohler I., Rudaz S., Guillarme D. Importance of instrumentation for fast liquid chromatography in pharmaceutical analysis. J. Pharm. Biomed. Anal. 2014, 87:105-119.
    • (2014) J. Pharm. Biomed. Anal. , vol.87 , pp. 105-119
    • Fekete, S.1    Kohler, I.2    Rudaz, S.3    Guillarme, D.4
  • 2
    • 58149105278 scopus 로고    scopus 로고
    • Sense and nonsense of high-temperature liquid chromatography
    • Heinisch S., Rocca J.-L. Sense and nonsense of high-temperature liquid chromatography. J. Chromatogr. A 2009, 1216:642-658.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 642-658
    • Heinisch, S.1    Rocca, J.-L.2
  • 3
    • 84884729894 scopus 로고    scopus 로고
    • Advances in the development of organic polymer monolithic columns and their applications in food analysis-a review
    • Jandera P. Advances in the development of organic polymer monolithic columns and their applications in food analysis-a review. J. Chromatogr. A 2013, 1313:37-53.
    • (2013) J. Chromatogr. A , vol.1313 , pp. 37-53
    • Jandera, P.1
  • 4
    • 79952817768 scopus 로고    scopus 로고
    • Shell particles, trials, tribulations and triumphs
    • Guiochon G., Gritti F. Shell particles, trials, tribulations and triumphs. J. Chromatogr. A 2011, 1218:1915-1938.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 1915-1938
    • Guiochon, G.1    Gritti, F.2
  • 5
    • 84857046162 scopus 로고    scopus 로고
    • Sub-2μm porous silica materials for enhanced separation performance in liquid chromatography
    • Wang Y., Ai F., Ng S.-C., Tan T.T.Y. Sub-2μm porous silica materials for enhanced separation performance in liquid chromatography. J. Chromatogr. A 2012, 1228:99-109.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 99-109
    • Wang, Y.1    Ai, F.2    Ng, S.-C.3    Tan, T.T.Y.4
  • 6
    • 79954629281 scopus 로고    scopus 로고
    • Quantification of glucuronidated and sulfated steroids in human urine by ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry
    • Badoud F., Grata E., Boccard J., Guillarme D., Veuthey J.-L., Rudaz S., Saugy M. Quantification of glucuronidated and sulfated steroids in human urine by ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry. Anal. Bioanal. Chem. 2011, 400:503-516.
    • (2011) Anal. Bioanal. Chem. , vol.400 , pp. 503-516
    • Badoud, F.1    Grata, E.2    Boccard, J.3    Guillarme, D.4    Veuthey, J.-L.5    Rudaz, S.6    Saugy, M.7
  • 7
    • 78049383226 scopus 로고    scopus 로고
    • Capillary liquid chromatography at ultrahigh pressures
    • Jorgenson J.W. Capillary liquid chromatography at ultrahigh pressures. Annu. Rev. Anal. Chem. 2010, 3:129-150.
    • (2010) Annu. Rev. Anal. Chem. , vol.3 , pp. 129-150
    • Jorgenson, J.W.1
  • 8
    • 50849111056 scopus 로고    scopus 로고
    • Multi-residue determination of veterinary drugs in milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry
    • Aguilera-Luiz M.M., Martínez Vidal J.L., Romero-González R., Garrido Frenich A. Multi-residue determination of veterinary drugs in milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry. J. Chromatogr. A 2008, 1205:10-16.
    • (2008) J. Chromatogr. A , vol.1205 , pp. 10-16
    • Aguilera-Luiz, M.M.1    Martínez Vidal, J.L.2    Romero-González, R.3    Garrido Frenich, A.4
  • 9
    • 62349135470 scopus 로고    scopus 로고
    • Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater
    • Bijlsma L., Sancho J.V., Pitarch E., Ibáňez M., Hernández F. Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater. J. Chromatogr. A 2009, 1216:3078-3089.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 3078-3089
    • Bijlsma, L.1    Sancho, J.V.2    Pitarch, E.3    Ibáňez, M.4    Hernández, F.5
  • 10
    • 67649382935 scopus 로고    scopus 로고
    • Simple and high-throughput method for the multimycotoxin analysis in cereals and related foods by ultra-high performance liquid chromatography/tandem mass spectrometry
    • Garrido Frenich A., Martínez Vidal J.L., Romero-González R., del Mar Aguilera-Luiz M. Simple and high-throughput method for the multimycotoxin analysis in cereals and related foods by ultra-high performance liquid chromatography/tandem mass spectrometry. Food Chem. 2009, 117:705-712.
    • (2009) Food Chem. , vol.117 , pp. 705-712
    • Garrido Frenich, A.1    Martínez Vidal, J.L.2    Romero-González, R.3    del Mar Aguilera-Luiz, M.4
  • 12
    • 84857055883 scopus 로고    scopus 로고
    • Fast-liquid chromatography using columns of different internal diameters packed with sub-2μm silica particles
    • D'Orazio G., Rocco A., Fanali S. Fast-liquid chromatography using columns of different internal diameters packed with sub-2μm silica particles. J. Chromatogr. A 2012, 1228:213-220.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 213-220
    • D'Orazio, G.1    Rocco, A.2    Fanali, S.3
  • 13
    • 85010246622 scopus 로고
    • Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography
    • van Deemter J.J., Zuiderweg F.J., Klinkenberg A. Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography. Chem. Eng. Sci. 1956, 5:271-289.
    • (1956) Chem. Eng. Sci. , vol.5 , pp. 271-289
    • van Deemter, J.J.1    Zuiderweg, F.J.2    Klinkenberg, A.3
  • 14
    • 84864614152 scopus 로고    scopus 로고
    • Introducing enantioselective ultrahigh-pressure liquid chromatography (eUHPLC): theoretical inspections and ultrafast separations on a new sub-2-μm Whelk-O1 stationary phase
    • Kotoni D., Ciogli A., Molinaro C., D'Acquarica I., Kocergin J., Szczerba T., Ritchie H., Villani C., Gasparrini F. Introducing enantioselective ultrahigh-pressure liquid chromatography (eUHPLC): theoretical inspections and ultrafast separations on a new sub-2-μm Whelk-O1 stationary phase. Anal. Chem. 2012, 84:6805-6813.
    • (2012) Anal. Chem. , vol.84 , pp. 6805-6813
    • Kotoni, D.1    Ciogli, A.2    Molinaro, C.3    D'Acquarica, I.4    Kocergin, J.5    Szczerba, T.6    Ritchie, H.7    Villani, C.8    Gasparrini, F.9
  • 15
    • 84870326087 scopus 로고    scopus 로고
    • Enantioselective ultra-high and high performance liquid chromatography: a comparative study of columns based on the Whelk-O1 selector
    • Kotoni D., Ciogli A., D'Acquarica I., Kocergin J., Szczerba T., Ritchie H., Villani C., Gasparrini F. Enantioselective ultra-high and high performance liquid chromatography: a comparative study of columns based on the Whelk-O1 selector. J. Chromatogr. A 2012, 1269:226-241.
    • (2012) J. Chromatogr. A , vol.1269 , pp. 226-241
    • Kotoni, D.1    Ciogli, A.2    D'Acquarica, I.3    Kocergin, J.4    Szczerba, T.5    Ritchie, H.6    Villani, C.7    Gasparrini, F.8
  • 16
    • 74049095533 scopus 로고    scopus 로고
    • Transition from enantioselective high performance to ultra-high performance liquid chromatography: a case study of a brush-type chiral stationary phase based on sub-5-micron to sub-2-micron silica particles
    • Cancelliere G., Ciogli A., D'Acquarica I., Gasparrini F., Kocergin J., Misiti D., Pierini M., Ritchie H., Simone P., Villani C. Transition from enantioselective high performance to ultra-high performance liquid chromatography: a case study of a brush-type chiral stationary phase based on sub-5-micron to sub-2-micron silica particles. J. Chromatogr. A 2010, 1217:990-999.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 990-999
    • Cancelliere, G.1    Ciogli, A.2    D'Acquarica, I.3    Gasparrini, F.4    Kocergin, J.5    Misiti, D.6    Pierini, M.7    Ritchie, H.8    Simone, P.9    Villani, C.10
  • 17
    • 84881008482 scopus 로고    scopus 로고
    • Enantioselective separation of dansyl-dl-amino acids and some racemates on click functionalized native α-cyclodextrin based sub-2μm columns
    • Ai F., Wang Y., Chen H., Yang Y., Tan T.T.Y., Ng S.-C. Enantioselective separation of dansyl-dl-amino acids and some racemates on click functionalized native α-cyclodextrin based sub-2μm columns. Analyst 2013, 138:2289-2294.
    • (2013) Analyst , vol.138 , pp. 2289-2294
    • Ai, F.1    Wang, Y.2    Chen, H.3    Yang, Y.4    Tan, T.T.Y.5    Ng, S.-C.6
  • 18
    • 78149358839 scopus 로고    scopus 로고
    • Sub-1-micron mesoporous silica particles functionalized with cyclodextrin derivative for rapid enantioseparations on ultra-high pressure liquid chromatography
    • Ai F., Li L., Ng S.-C., Tan T.T.Y. Sub-1-micron mesoporous silica particles functionalized with cyclodextrin derivative for rapid enantioseparations on ultra-high pressure liquid chromatography. J. Chromatogr. A 2010, 1217:7502-7506.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 7502-7506
    • Ai, F.1    Li, L.2    Ng, S.-C.3    Tan, T.T.Y.4
  • 19
    • 84908087249 scopus 로고    scopus 로고
    • Novel supports in chiral stationary phase development for liquid chromatography. Preparation, characterization and application of ordered mesoporous silica particles
    • Sierra I., Pérez-Quintanilla D., Morante S., Gaňán J. Novel supports in chiral stationary phase development for liquid chromatography. Preparation, characterization and application of ordered mesoporous silica particles. J. Chromatogr. A 2014, 1363:27-40.
    • (2014) J. Chromatogr. A , vol.1363 , pp. 27-40
    • Sierra, I.1    Pérez-Quintanilla, D.2    Morante, S.3    Gaňán, J.4
  • 20
    • 84891372167 scopus 로고    scopus 로고
    • Enantioseparation and selective detection of D-amino acids by ultra-high-performance liquid chromatography/mass spectrometry in analysis of complex biological samples
    • Müller C., Fonseca J.R., Rock T.M., Krauss-Etschmann S., Schmitt-Kopplin P. Enantioseparation and selective detection of D-amino acids by ultra-high-performance liquid chromatography/mass spectrometry in analysis of complex biological samples. J. Chromatogr. A 2014, 1324:109-114.
    • (2014) J. Chromatogr. A , vol.1324 , pp. 109-114
    • Müller, C.1    Fonseca, J.R.2    Rock, T.M.3    Krauss-Etschmann, S.4    Schmitt-Kopplin, P.5
  • 22
    • 84867336783 scopus 로고    scopus 로고
    • Simultaneous determination of DL-lactic acid and DL-3-hydroxybutyric acid enantiomers in saliva of diabetes mellitus patients by high-throughput LC-ESI-MS/MS
    • Tsutsui H., Mochizuki T., Maeda T., Noge I., Kitagawa Y., Min J.Z., Todoroki K., Inoue K., Toyo'oka T. Simultaneous determination of DL-lactic acid and DL-3-hydroxybutyric acid enantiomers in saliva of diabetes mellitus patients by high-throughput LC-ESI-MS/MS. Anal. Bioanal. Chem. 2012, 404:1925-1934.
    • (2012) Anal. Bioanal. Chem. , vol.404 , pp. 1925-1934
    • Tsutsui, H.1    Mochizuki, T.2    Maeda, T.3    Noge, I.4    Kitagawa, Y.5    Min, J.Z.6    Todoroki, K.7    Inoue, K.8    Toyo'oka, T.9
  • 23
    • 84866262138 scopus 로고    scopus 로고
    • A validated enantioselective LC-MS/MS assay for the simultaneous determination of carvedilol and its pharmacologically active 4'-hydroxyphenyl metabolite in human plasma: application to a clinical pharmacokinetic study
    • Furlong M.T., He B., Mylott W., Zhao S., Mariannino T., Shen J., Stouffer B. A validated enantioselective LC-MS/MS assay for the simultaneous determination of carvedilol and its pharmacologically active 4'-hydroxyphenyl metabolite in human plasma: application to a clinical pharmacokinetic study. J. Pharm. Biomed. Anal. 2012, 70:574-579.
    • (2012) J. Pharm. Biomed. Anal. , vol.70 , pp. 574-579
    • Furlong, M.T.1    He, B.2    Mylott, W.3    Zhao, S.4    Mariannino, T.5    Shen, J.6    Stouffer, B.7
  • 24
    • 84861457522 scopus 로고    scopus 로고
    • Simultaneous determination of the absolute configuration of twelve monosaccharide enantiomers from natural products in a single injection by a UPLC-UV/MS method
    • Wang Y.-H., Avula B., Fu X., Wang M., Khan I.A. Simultaneous determination of the absolute configuration of twelve monosaccharide enantiomers from natural products in a single injection by a UPLC-UV/MS method. Planta Med. 2012, 78:834-837.
    • (2012) Planta Med. , vol.78 , pp. 834-837
    • Wang, Y.-H.1    Avula, B.2    Fu, X.3    Wang, M.4    Khan, I.A.5
  • 25
    • 79952614699 scopus 로고    scopus 로고
    • Enantioseparation of dansyl amino acids by ultra-high pressure liquid chromatography using cationic β-cyclodextrins as chiral additives
    • Xiao Y., Tan T.T.Y., Ng S.-C. Enantioseparation of dansyl amino acids by ultra-high pressure liquid chromatography using cationic β-cyclodextrins as chiral additives. Analyst 2011, 136:1433-1439.
    • (2011) Analyst , vol.136 , pp. 1433-1439
    • Xiao, Y.1    Tan, T.T.Y.2    Ng, S.-C.3
  • 26
    • 75849149182 scopus 로고    scopus 로고
    • Fast chiral separation of drugs using columns packed with sub-2μm particles and ultra-high pressure
    • Guillarme D., Bonvin G., Badoud F., Schappler J., Rudaz S., Veuthey J.-L. Fast chiral separation of drugs using columns packed with sub-2μm particles and ultra-high pressure. Chirality 2010, 22:320-330.
    • (2010) Chirality , vol.22 , pp. 320-330
    • Guillarme, D.1    Bonvin, G.2    Badoud, F.3    Schappler, J.4    Rudaz, S.5    Veuthey, J.-L.6
  • 27
    • 67651001565 scopus 로고    scopus 로고
    • Enantioselective determination of trantinterol in rat plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry after derivatization
    • Yang J., Wang Y., Pan L., Li N., Lu X., Guan J., Cheng M., Li F. Enantioselective determination of trantinterol in rat plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry after derivatization. Talanta 2009, 79:1204-1208.
    • (2009) Talanta , vol.79 , pp. 1204-1208
    • Yang, J.1    Wang, Y.2    Pan, L.3    Li, N.4    Lu, X.5    Guan, J.6    Cheng, M.7    Li, F.8
  • 28
    • 0037504139 scopus 로고    scopus 로고
    • Application of diaza-18-crown-6-capped β-cyclodextrin bonded silica particles as chiral stationary phases for ultrahigh pressure capillary liquid chromatography
    • Gong Y., Xiang Y., Yue B., Xue G., Bradshaw J.S., Lee H.K., Lee M.L. Application of diaza-18-crown-6-capped β-cyclodextrin bonded silica particles as chiral stationary phases for ultrahigh pressure capillary liquid chromatography. J. Chromatogr. A 2003, 1002:63-70.
    • (2003) J. Chromatogr. A , vol.1002 , pp. 63-70
    • Gong, Y.1    Xiang, Y.2    Yue, B.3    Xue, G.4    Bradshaw, J.S.5    Lee, H.K.6    Lee, M.L.7
  • 29
    • 0035691839 scopus 로고    scopus 로고
    • Synthesis of crown ether-capped 3-(2-O-β-Cyclodextrin)-2-hydroxypropylsilyl silica particles for use as chiral stationary phases in chromatography
    • Gong Y., Xue G., Bradshaw J.S., Lee M.L., Lee H.K. Synthesis of crown ether-capped 3-(2-O-β-Cyclodextrin)-2-hydroxypropylsilyl silica particles for use as chiral stationary phases in chromatography. J. Heterocycle Chem. 2001, 38:1317-1321.
    • (2001) J. Heterocycle Chem. , vol.38 , pp. 1317-1321
    • Gong, Y.1    Xue, G.2    Bradshaw, J.S.3    Lee, M.L.4    Lee, H.K.5
  • 30
    • 0347381322 scopus 로고    scopus 로고
    • Very fast enantioseparation in high-performance liquid chromatography using cellulose tris(3,5-dimethylphenylcarbamate) coated on monolithic silica support
    • Chankvetadze B., Yamamoto C., Okamoto Y. Very fast enantioseparation in high-performance liquid chromatography using cellulose tris(3,5-dimethylphenylcarbamate) coated on monolithic silica support. Chem. Lett. 2003, 32:850-851.
    • (2003) Chem. Lett. , vol.32 , pp. 850-851
    • Chankvetadze, B.1    Yamamoto, C.2    Okamoto, Y.3
  • 31
    • 33644862381 scopus 로고    scopus 로고
    • High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic silica modified with amylose tris(3,5-dimethylphenylcarbamate)
    • Chankvetadze B., Yamamoto C., Kamigaito M., Tanaka N., Nakanishi K., Okamoto Y. High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic silica modified with amylose tris(3,5-dimethylphenylcarbamate). J. Chromatogr. A 2006, 1110:46-52.
    • (2006) J. Chromatogr. A , vol.1110 , pp. 46-52
    • Chankvetadze, B.1    Yamamoto, C.2    Kamigaito, M.3    Tanaka, N.4    Nakanishi, K.5    Okamoto, Y.6
  • 32
    • 84858800044 scopus 로고    scopus 로고
    • Comparative high-performance liquid chromatography enantioseparations on polysaccharide based chiral stationary phases prepared by coating totally porous and core-shell silica particles
    • Lomsadze K., Jibuti G., Farkas T., Chankvetadze B. Comparative high-performance liquid chromatography enantioseparations on polysaccharide based chiral stationary phases prepared by coating totally porous and core-shell silica particles. J. Chromatogr. A 2012, 1234:50-55.
    • (2012) J. Chromatogr. A , vol.1234 , pp. 50-55
    • Lomsadze, K.1    Jibuti, G.2    Farkas, T.3    Chankvetadze, B.4
  • 34
    • 76649129300 scopus 로고    scopus 로고
    • Our favorite materials: silica hydride stationary phases
    • Pesek J.J., Matyska M.T. Our favorite materials: silica hydride stationary phases. J. Sep. Sci. 2009, 32:3999-4011.
    • (2009) J. Sep. Sci. , vol.32 , pp. 3999-4011
    • Pesek, J.J.1    Matyska, M.T.2
  • 35
    • 33645644672 scopus 로고    scopus 로고
    • Silica hydride surfaces: versatile separation media for chromatographic and electrophoretic analyses
    • Pesek J.J., Matyska M.T. Silica hydride surfaces: versatile separation media for chromatographic and electrophoretic analyses. J. Liq. Chromatogr. Related Technol. 2006, 29:1105-1124.
    • (2006) J. Liq. Chromatogr. Related Technol. , vol.29 , pp. 1105-1124
    • Pesek, J.J.1    Matyska, M.T.2
  • 36
    • 0035104429 scopus 로고    scopus 로고
    • Use of vancomycin silica stationary phase in packed capillary electrochromatography. I. Enantiomer separation of basic compounds
    • Desiderio C., Aturki Z., Fanali S. Use of vancomycin silica stationary phase in packed capillary electrochromatography. I. Enantiomer separation of basic compounds. Electrophoresis 2001, 22:535-543.
    • (2001) Electrophoresis , vol.22 , pp. 535-543
    • Desiderio, C.1    Aturki, Z.2    Fanali, S.3
  • 37
    • 29944443923 scopus 로고    scopus 로고
    • Enantiomeric separation of mirtazapine and its metabolites by nano-liquid chromatography with UV-absorption and mass spectrometric detection
    • Fanali S., Aturki Z., Kašicka V., Raggi M.A., D'Orazio G. Enantiomeric separation of mirtazapine and its metabolites by nano-liquid chromatography with UV-absorption and mass spectrometric detection. J. Sep. Sci. 2005, 28:1719-1728.
    • (2005) J. Sep. Sci. , vol.28 , pp. 1719-1728
    • Fanali, S.1    Aturki, Z.2    Kašicka, V.3    Raggi, M.A.4    D'Orazio, G.5
  • 38
    • 20444400567 scopus 로고    scopus 로고
    • Use of vancomycin chiral stationary phase for the enantiomeric resolution of basic and acidic compounds by nano-liquid chromatography
    • D'Orazio G., Aturki Z., Cristalli M., Quaglia M.G., Fanali S. Use of vancomycin chiral stationary phase for the enantiomeric resolution of basic and acidic compounds by nano-liquid chromatography. J. Chromatogr. A 2005, 1081:105-113.
    • (2005) J. Chromatogr. A , vol.1081 , pp. 105-113
    • D'Orazio, G.1    Aturki, Z.2    Cristalli, M.3    Quaglia, M.G.4    Fanali, S.5
  • 39
    • 10044281520 scopus 로고    scopus 로고
    • Enantiomeric separation of chlorophenoxy acid herbicides by nano liquid chromatography-UV detection on a vancomycin-based chiral stationary phase
    • Rosales-Conrado N., León-González M.E., D'Orazio G., Fanali S. Enantiomeric separation of chlorophenoxy acid herbicides by nano liquid chromatography-UV detection on a vancomycin-based chiral stationary phase. J. Sep. Sci. 2004, 27:1303-1308.
    • (2004) J. Sep. Sci. , vol.27 , pp. 1303-1308
    • Rosales-Conrado, N.1    León-González, M.E.2    D'Orazio, G.3    Fanali, S.4
  • 40
    • 43949161069 scopus 로고
    • Ramped-amplitude cross polarization in magic-angle-spinning NMR
    • Metz G., Wu X.L., Smith S.O. Ramped-amplitude cross polarization in magic-angle-spinning NMR. J. Magn. Reson. Ser. A 1994, 110:219-227.
    • (1994) J. Magn. Reson. Ser. A , vol.110 , pp. 219-227
    • Metz, G.1    Wu, X.L.2    Smith, S.O.3
  • 42
    • 84901913564 scopus 로고    scopus 로고
    • A nano-LC/UV method for the analysis of principal phenolic compounds in commercial citrus juices and evaluation of antioxidant potential
    • Rocco A., Fanali C., Dugo L., Mondello L. A nano-LC/UV method for the analysis of principal phenolic compounds in commercial citrus juices and evaluation of antioxidant potential. Electrophoresis 2014, 35:1701-1708.
    • (2014) Electrophoresis , vol.35 , pp. 1701-1708
    • Rocco, A.1    Fanali, C.2    Dugo, L.3    Mondello, L.4
  • 43
    • 74049114178 scopus 로고    scopus 로고
    • Analysis of phytosterols in extra-virgin olive oil by nano-liquid chromatography
    • Rocco A., Fanali S. Analysis of phytosterols in extra-virgin olive oil by nano-liquid chromatography. J. Chromatogr. A 2009, 1216:7173-7178.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 7173-7178
    • Rocco, A.1    Fanali, S.2
  • 44
    • 0037356508 scopus 로고    scopus 로고
    • NMR investigations of stationary phases
    • Albert K. NMR investigations of stationary phases. J. Sep. Sci. 2003, 26:215-224.
    • (2003) J. Sep. Sci. , vol.26 , pp. 215-224
    • Albert, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.