메뉴 건너뛰기




Volumn 87, Issue , 2014, Pages 105-119

Importance of instrumentation for fast liquid chromatography in pharmaceutical analysis

Author keywords

Core shell; Extra column variance; Gradient dwell volume; Maximum system pressure; UHPLC

Indexed keywords

SOLVENT;

EID: 84889602021     PISSN: 07317085     EISSN: 1873264X     Source Type: Journal    
DOI: 10.1016/j.jpba.2013.03.012     Document Type: Review
Times cited : (131)

References (115)
  • 1
    • 34248573460 scopus 로고    scopus 로고
    • Method transfer for fast liquid chromatography in pharmaceutical analysis: application to short columns packed with small particle. Part I: isocratic separation
    • Guillarme D., Nguyen D.T., Rudaz S., Veuthey J.L. Method transfer for fast liquid chromatography in pharmaceutical analysis: application to short columns packed with small particle. Part I: isocratic separation. Eur. J. Pharm. Biopharm. 2007, 66:475-482.
    • (2007) Eur. J. Pharm. Biopharm. , vol.66 , pp. 475-482
    • Guillarme, D.1    Nguyen, D.T.2    Rudaz, S.3    Veuthey, J.L.4
  • 2
    • 0042347638 scopus 로고    scopus 로고
    • Chromatographic performance of monolithic and particulate stationary phases. Hydrodynamics and adsorption capacity
    • Leinweber F.C., Tallarek U. Chromatographic performance of monolithic and particulate stationary phases. Hydrodynamics and adsorption capacity. J. Chromatogr. A 2003, 1006:207-228.
    • (2003) J. Chromatogr. A , vol.1006 , pp. 207-228
    • Leinweber, F.C.1    Tallarek, U.2
  • 3
    • 34748882992 scopus 로고    scopus 로고
    • Monolithic columns in high-performance liquid chromatography
    • Guiochon G. Monolithic columns in high-performance liquid chromatography. J. Chromatogr. A 2007, 1168:101-168.
    • (2007) J. Chromatogr. A , vol.1168 , pp. 101-168
    • Guiochon, G.1
  • 4
    • 51549097552 scopus 로고    scopus 로고
    • Highlights of HPLC 2008: Part I
    • Majors M.E. Highlights of HPLC 2008: Part I. LCGC North Am. 2008, 26:676-691.
    • (2008) LCGC North Am. , vol.26 , pp. 676-691
    • Majors, M.E.1
  • 5
    • 84855604573 scopus 로고    scopus 로고
    • Morphology and separation efficiency of a new generation of analytical silica monoliths
    • Hormann K., Mullner T., Bruns S., Holtzel A., Tallarek U. Morphology and separation efficiency of a new generation of analytical silica monoliths. J. Chromatogr. A 2012, 1222:46-58.
    • (2012) J. Chromatogr. A , vol.1222 , pp. 46-58
    • Hormann, K.1    Mullner, T.2    Bruns, S.3    Holtzel, A.4    Tallarek, U.5
  • 6
    • 84963101542 scopus 로고
    • Kinetic conditions for optimum speed and resolution in column chromatography
    • Knox J.H., Saleem M. Kinetic conditions for optimum speed and resolution in column chromatography. J. Chromatogr. Sci. 1969, 7:614-622.
    • (1969) J. Chromatogr. Sci. , vol.7 , pp. 614-622
    • Knox, J.H.1    Saleem, M.2
  • 7
    • 0017536981 scopus 로고
    • Practical aspect of LC theory
    • Knox J.H. Practical aspect of LC theory. J. Chromatogr. Sci. 1977, 15:352-364.
    • (1977) J. Chromatogr. Sci. , vol.15 , pp. 352-364
    • Knox, J.H.1
  • 8
    • 0030802374 scopus 로고    scopus 로고
    • Some reflections on speed and efficiency of modern chromatographic methods
    • Poppe H. Some reflections on speed and efficiency of modern chromatographic methods. J. Chromatogr. A 1997, 778:3-21.
    • (1997) J. Chromatogr. A , vol.778 , pp. 3-21
    • Poppe, H.1
  • 10
    • 28544450370 scopus 로고    scopus 로고
    • Advancing LC performance with smaller particles and higher pressure
    • Mazzeo J.R., Neue U.D., Kele M., Plumb R.S. Advancing LC performance with smaller particles and higher pressure. Anal. Chem. 2005, 77:460-467.
    • (2005) Anal. Chem. , vol.77 , pp. 460-467
    • Mazzeo, J.R.1    Neue, U.D.2    Kele, M.3    Plumb, R.S.4
  • 11
    • 85054037218 scopus 로고    scopus 로고
    • Method transfer between conventional HPLC and UHPLC
    • Royal Society of Chemistry, Cambridge, UK, J.L. Veuthey, D. Guillarme (Eds.)
    • Debrus B., Rozet E., Hubert P., Veuthey J.L., Rudaz S., Guillarme D. Method transfer between conventional HPLC and UHPLC. UHPLC in Life Sciences 2012, 67-101. Royal Society of Chemistry, Cambridge, UK. J.L. Veuthey, D. Guillarme (Eds.).
    • (2012) UHPLC in Life Sciences , pp. 67-101
    • Debrus, B.1    Rozet, E.2    Hubert, P.3    Veuthey, J.L.4    Rudaz, S.5    Guillarme, D.6
  • 12
    • 33748427633 scopus 로고    scopus 로고
    • Fast analysis in liquid chromatography using small particle size and high pressure
    • Nguyen D.T., Guillarme D., Rudaz S., Veuthey J.L. Fast analysis in liquid chromatography using small particle size and high pressure. J. Sep. Sci. 2006, 29:1836-1848.
    • (2006) J. Sep. Sci. , vol.29 , pp. 1836-1848
    • Nguyen, D.T.1    Guillarme, D.2    Rudaz, S.3    Veuthey, J.L.4
  • 14
    • 84857054589 scopus 로고    scopus 로고
    • Fast liquid chromatography: the domination of core-shell and very fine particles
    • Fekete S., Olah E., Fekete J. Fast liquid chromatography: the domination of core-shell and very fine particles. J. Chromatogr. A 2012, 1228:57-71.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 57-71
    • Fekete, S.1    Olah, E.2    Fekete, J.3
  • 15
    • 34548421091 scopus 로고    scopus 로고
    • Comparative study of the performance of columns packed with several new fine silica particles. Would the external roughness of the particles affect column properties?
    • Gritti F., Guiochon G. Comparative study of the performance of columns packed with several new fine silica particles. Would the external roughness of the particles affect column properties?. J. Chromatogr. A 2007, 1166:30-46.
    • (2007) J. Chromatogr. A , vol.1166 , pp. 30-46
    • Gritti, F.1    Guiochon, G.2
  • 16
    • 77953596053 scopus 로고    scopus 로고
    • Physical properties and structure of fine core-shell particles used as packing materials for chromatography Relationships between particle characteristics and column performance
    • Gritti F., Leonardis I., Abia J., Guiochon G. Physical properties and structure of fine core-shell particles used as packing materials for chromatography Relationships between particle characteristics and column performance. J. Chromatogr. A 2010, 1217:3819-3843.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3819-3843
    • Gritti, F.1    Leonardis, I.2    Abia, J.3    Guiochon, G.4
  • 17
    • 78751701553 scopus 로고    scopus 로고
    • The mass transfer kinetics in columns packed with Halo-ES shell particles
    • Gritti F., Guiochon G. The mass transfer kinetics in columns packed with Halo-ES shell particles. J. Chromatogr. A 2011, 1218:907-921.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 907-921
    • Gritti, F.1    Guiochon, G.2
  • 18
    • 77952672825 scopus 로고    scopus 로고
    • Comparative study of new shell-type, sub-2 micron fully porous and monolith stationary phases, focusing on mass-transfer resistance
    • Olah E., Fekete S., Fekete J., Ganzler K. Comparative study of new shell-type, sub-2 micron fully porous and monolith stationary phases, focusing on mass-transfer resistance. J. Chromatogr. A 2010, 1217:3642-3653.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3642-3653
    • Olah, E.1    Fekete, S.2    Fekete, J.3    Ganzler, K.4
  • 19
    • 78149495855 scopus 로고    scopus 로고
    • Efficiency of the new sub-2 mum core-shell (Kinetex) column in practice, applied for small and large molecule separation
    • Fekete S., Ganzler K., Fekete J. Efficiency of the new sub-2 mum core-shell (Kinetex) column in practice, applied for small and large molecule separation. J. Pharm. Biomed. Anal. 2011, 54:482-490.
    • (2011) J. Pharm. Biomed. Anal. , vol.54 , pp. 482-490
    • Fekete, S.1    Ganzler, K.2    Fekete, J.3
  • 20
    • 77957875308 scopus 로고    scopus 로고
    • Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance
    • Cabooter D., Fanigliulo A., Bellazzi G., Allieri B., Rottigni A., Desmet G. Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance. J. Chromatogr. A 2010, 1217:7074-7081.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 7074-7081
    • Cabooter, D.1    Fanigliulo, A.2    Bellazzi, G.3    Allieri, B.4    Rottigni, A.5    Desmet, G.6
  • 21
    • 84857038683 scopus 로고    scopus 로고
    • Evaluation of columns packed with shell particles with compounds of pharmaceutical interest
    • Ruta J., Zurlino D., Grivel C., Heinisch S., Veuthey J.L., Guillarme D. Evaluation of columns packed with shell particles with compounds of pharmaceutical interest. J. Chromatogr. A 2012, 1228:221-231.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 221-231
    • Ruta, J.1    Zurlino, D.2    Grivel, C.3    Heinisch, S.4    Veuthey, J.L.5    Guillarme, D.6
  • 22
    • 82955162687 scopus 로고    scopus 로고
    • Analysis of peptides and proteins using sub-2μm fully porous and sub 3-μm shell particles
    • Staub A., Zurlino D., Rudaz S., Veuthey J.L., Guillarme D. Analysis of peptides and proteins using sub-2μm fully porous and sub 3-μm shell particles. J. Chromatogr. A 2011, 1218:8903-8914.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 8903-8914
    • Staub, A.1    Zurlino, D.2    Rudaz, S.3    Veuthey, J.L.4    Guillarme, D.5
  • 25
    • 79960138586 scopus 로고    scopus 로고
    • The impact of extra-column band broadening on the chromatographic efficiency of 5cm long narrow-bore very efficient columns
    • Fekete S., Fekete J. The impact of extra-column band broadening on the chromatographic efficiency of 5cm long narrow-bore very efficient columns. J. Chromatogr. A 2011, 1218:5286-5291.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 5286-5291
    • Fekete, S.1    Fekete, J.2
  • 26
    • 77951205929 scopus 로고    scopus 로고
    • Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments
    • Gritti F., Sanchez C.A., Farkas T., Guiochon G. Achieving the full performance of highly efficient columns by optimizing conventional benchmark high-performance liquid chromatography instruments. J. Chromatogr. A 2010, 1217:3000-3012.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3000-3012
    • Gritti, F.1    Sanchez, C.A.2    Farkas, T.3    Guiochon, G.4
  • 27
    • 67650032931 scopus 로고    scopus 로고
    • Effects of extra-column band spreading, liquid chromatography system operating pressure, and column temperature on the performance of sub-2-μm porous particles
    • Fountain K.J., Neue U.D., Grumbach E.S., Diehl D.M. Effects of extra-column band spreading, liquid chromatography system operating pressure, and column temperature on the performance of sub-2-μm porous particles. J. Chromatogr. A 2009, 1216:5979-5988.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 5979-5988
    • Fountain, K.J.1    Neue, U.D.2    Grumbach, E.S.3    Diehl, D.M.4
  • 28
    • 77954176876 scopus 로고    scopus 로고
    • Evaluation of 1.0mm i.d. column performances on ultra high pressure liquid chromatography instrumentation
    • Lestremau F., Wu D., Szucs R. Evaluation of 1.0mm i.d. column performances on ultra high pressure liquid chromatography instrumentation. J. Chromatogr. A 2010, 1217:4925-4933.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 4925-4933
    • Lestremau, F.1    Wu, D.2    Szucs, R.3
  • 29
    • 84865313284 scopus 로고    scopus 로고
    • Effect of extra-column volume on practical chromatographic parameters of sub-2-mum particle-packed columns in ultra-high pressure liquid chromatography
    • Wu N., Bradley A.C., Welch C.J., Zhang L. Effect of extra-column volume on practical chromatographic parameters of sub-2-mum particle-packed columns in ultra-high pressure liquid chromatography. J. Sep. Sci. 2012, 35:2018-2025.
    • (2012) J. Sep. Sci. , vol.35 , pp. 2018-2025
    • Wu, N.1    Bradley, A.C.2    Welch, C.J.3    Zhang, L.4
  • 30
    • 0017522710 scopus 로고
    • Sampling and extra-column effects in high-performance liquid chromatography; influence of peak skew on plate count calculations
    • Kirkland J.J., Yau W.W., Stoklosa H.J., Dilks C.H. Sampling and extra-column effects in high-performance liquid chromatography; influence of peak skew on plate count calculations. J. Chromatogr. Sci. 1977, 15:303-316.
    • (1977) J. Chromatogr. Sci. , vol.15 , pp. 303-316
    • Kirkland, J.J.1    Yau, W.W.2    Stoklosa, H.J.3    Dilks, C.H.4
  • 31
    • 0019055142 scopus 로고
    • Microbore columns - design, construction, and operation
    • Reese C.E., Scott R.P.W. Microbore columns - design, construction, and operation. J. Chromatogr. Sci. 1980, 18:479-486.
    • (1980) J. Chromatogr. Sci. , vol.18 , pp. 479-486
    • Reese, C.E.1    Scott, R.P.W.2
  • 32
    • 0347630619 scopus 로고
    • Extra-column effects in polarographic versus UV detection in high-performance liquid chromatography
    • Kutner W., Debowski J., Kemula W. Extra-column effects in polarographic versus UV detection in high-performance liquid chromatography. J. Chromatogr. 1981, 218:45-50.
    • (1981) J. Chromatogr. , vol.218 , pp. 45-50
    • Kutner, W.1    Debowski, J.2    Kemula, W.3
  • 33
    • 2442619058 scopus 로고
    • Extra-column band spreading in high-performance liquid chromatography-mass spectrometry using a moving belt interface: Numerical evaluation of system variance
    • Games D.E., Hewlins M.J., Westwood S.A., Morgan D.J. Extra-column band spreading in high-performance liquid chromatography-mass spectrometry using a moving belt interface: Numerical evaluation of system variance. J. Chromatogr. 1982, 205:62-67.
    • (1982) J. Chromatogr. , vol.205 , pp. 62-67
    • Games, D.E.1    Hewlins, M.J.2    Westwood, S.A.3    Morgan, D.J.4
  • 34
    • 0001559228 scopus 로고
    • Use of conventinal instrumentation with microbore column in high-performance liquid chromatography
    • Kok W.T., Brinkman U.A.T., Frei R.W., Hanekamp H.B., Nooitgedacht F., Poppe H. Use of conventinal instrumentation with microbore column in high-performance liquid chromatography. J. Chromatogr. 1982, 237:357-369.
    • (1982) J. Chromatogr. , vol.237 , pp. 357-369
    • Kok, W.T.1    Brinkman, U.A.T.2    Frei, R.W.3    Hanekamp, H.B.4    Nooitgedacht, F.5    Poppe, H.6
  • 35
    • 0020087930 scopus 로고
    • Determination of the extra column dispersion occurring in the different components of a chromatographic system
    • Scott R.P.W., Simpson C.F. Determination of the extra column dispersion occurring in the different components of a chromatographic system. J. Chromatogr. Sci. 1982, 20:62-66.
    • (1982) J. Chromatogr. Sci. , vol.20 , pp. 62-66
    • Scott, R.P.W.1    Simpson, C.F.2
  • 36
    • 0010266142 scopus 로고
    • Minimization of extra-column effects with microbore columns using electrochemical detection
    • Slais K., Kourilova D. Minimization of extra-column effects with microbore columns using electrochemical detection. J. Chromatogr. 1983, 258:57-63.
    • (1983) J. Chromatogr. , vol.258 , pp. 57-63
    • Slais, K.1    Kourilova, D.2
  • 37
    • 0011341448 scopus 로고
    • Role of extra-column volume in the efficiency of high-speed liquid chromatography
    • Kahle V., Krejci M. Role of extra-column volume in the efficiency of high-speed liquid chromatography. J. Chromatogr. 1985, 321:69-79.
    • (1985) J. Chromatogr. , vol.321 , pp. 69-79
    • Kahle, V.1    Krejci, M.2
  • 38
    • 0141534698 scopus 로고
    • A practical method to predict the effect of extra-column variance on observed efficiency in high performance liquid chromatography
    • Cohen K.A., Stuart J.D. A practical method to predict the effect of extra-column variance on observed efficiency in high performance liquid chromatography. J. Chromatogr. Sci. 1987, 25:381-390.
    • (1987) J. Chromatogr. Sci. , vol.25 , pp. 381-390
    • Cohen, K.A.1    Stuart, J.D.2
  • 39
    • 0031584712 scopus 로고    scopus 로고
    • Prediction of the preparative chromatography performance with a very small column
    • Kaltenbrunner O., Jungbauer A., Yamamoto S. Prediction of the preparative chromatography performance with a very small column. J. Chromatogr. A 1997, 760:41-53.
    • (1997) J. Chromatogr. A , vol.760 , pp. 41-53
    • Kaltenbrunner, O.1    Jungbauer, A.2    Yamamoto, S.3
  • 40
    • 0034667825 scopus 로고    scopus 로고
    • Peak broadening in protein chromatography with monoliths at very fast separations
    • Hahn R., Jungbauer A. Peak broadening in protein chromatography with monoliths at very fast separations. Anal. Chem. 2000, 72:4853-4858.
    • (2000) Anal. Chem. , vol.72 , pp. 4853-4858
    • Hahn, R.1    Jungbauer, A.2
  • 41
    • 2442587458 scopus 로고    scopus 로고
    • Extra-column dispersion of macromolecular solutes in aqueous-phase size-exclusion chromatography
    • Grznarova G., Polakovic M., Acai P., Gorner T. Extra-column dispersion of macromolecular solutes in aqueous-phase size-exclusion chromatography. J. Chromatogr. A 2004, 1040:33-43.
    • (2004) J. Chromatogr. A , vol.1040 , pp. 33-43
    • Grznarova, G.1    Polakovic, M.2    Acai, P.3    Gorner, T.4
  • 42
    • 0003381083 scopus 로고
    • Dispersion of soluble matter in solvent flowing slowly through a tube
    • Taylor G. Dispersion of soluble matter in solvent flowing slowly through a tube. Proc. R. Soc. Lond. A 1953, 219:186-203.
    • (1953) Proc. R. Soc. Lond. A , vol.219 , pp. 186-203
    • Taylor, G.1
  • 43
    • 0001450380 scopus 로고
    • The dispersion of matter in turbulent flow through a pipe
    • Taylor G. The dispersion of matter in turbulent flow through a pipe. Proc. R. Soc. Lond. A 1954, 223:446-468.
    • (1954) Proc. R. Soc. Lond. A , vol.223 , pp. 446-468
    • Taylor, G.1
  • 44
    • 0002864183 scopus 로고
    • On the dispersion of a solute in a fluid flowing through a tube
    • Aris R. On the dispersion of a solute in a fluid flowing through a tube. Proc. R. Soc. Lond. A 1956, 235:67-77.
    • (1956) Proc. R. Soc. Lond. A , vol.235 , pp. 67-77
    • Aris, R.1
  • 45
    • 0001445029 scopus 로고
    • Conditions under which dispersion of a solute in a stream of solvent can be used to measure molecular diffusion
    • Taylor G. Conditions under which dispersion of a solute in a stream of solvent can be used to measure molecular diffusion. Proc. R. Soc. Lond. A 1954, 225:473-477.
    • (1954) Proc. R. Soc. Lond. A , vol.225 , pp. 473-477
    • Taylor, G.1
  • 46
    • 0000746069 scopus 로고
    • Laminar dispersion in capillaries: Part I. Mathematical analysis
    • Ananthakrishnan V., Gill W.N., Barduhn A.J. Laminar dispersion in capillaries: Part I. Mathematical analysis. AIChE J. 1965, 11:1063-1072.
    • (1965) AIChE J. , vol.11 , pp. 1063-1072
    • Ananthakrishnan, V.1    Gill, W.N.2    Barduhn, A.J.3
  • 47
    • 0001511366 scopus 로고
    • Early phases of the dispersion of a sample injected in poiseuille flow
    • Golay M.J.E., Atwood J.G. Early phases of the dispersion of a sample injected in poiseuille flow. J. Chromatogr. 1979, 186:353-370.
    • (1979) J. Chromatogr. , vol.186 , pp. 353-370
    • Golay, M.J.E.1    Atwood, J.G.2
  • 48
    • 0002029738 scopus 로고
    • Dispersion of peaks by short straight open tubes in liquid chromatography systems
    • Atwood J.G., Golay M.J.E. Dispersion of peaks by short straight open tubes in liquid chromatography systems. J. Chromatogr. 1981, 218:97-122.
    • (1981) J. Chromatogr. , vol.218 , pp. 97-122
    • Atwood, J.G.1    Golay, M.J.E.2
  • 50
    • 0001535486 scopus 로고    scopus 로고
    • Marcel Dekker, New York, J.C. Giddings, R.A. Keller (Eds.)
    • Sternberg J.C. Advances in Chromatography 1996, Marcel Dekker, New York. J.C. Giddings, R.A. Keller (Eds.).
    • (1996) Advances in Chromatography
    • Sternberg, J.C.1
  • 51
    • 79959350827 scopus 로고    scopus 로고
    • Accurate measurements of peak variances: importance of this accuracy in the determination of the true corrected plate heights of chromatographic columns
    • Gritti F., Guiochon G. Accurate measurements of peak variances: importance of this accuracy in the determination of the true corrected plate heights of chromatographic columns. J. Chromatogr. A 2011, 1218:4452-4461.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 4452-4461
    • Gritti, F.1    Guiochon, G.2
  • 52
    • 79959538989 scopus 로고    scopus 로고
    • On the minimization of the band-broadening contributions of a modern, very high pressure liquid chromatograph
    • Gritti F., Guiochon G. On the minimization of the band-broadening contributions of a modern, very high pressure liquid chromatograph. J. Chromatogr. A 2011, 1218:4632-4648.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 4632-4648
    • Gritti, F.1    Guiochon, G.2
  • 53
    • 33750938293 scopus 로고    scopus 로고
    • Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters
    • Gritti F., Felinger A., Guiochon G. Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters. J. Chromatogr. A 2006, 1136:57-72.
    • (2006) J. Chromatogr. A , vol.1136 , pp. 57-72
    • Gritti, F.1    Felinger, A.2    Guiochon, G.3
  • 54
    • 84872264899 scopus 로고    scopus 로고
    • The effect of pressure and mobile phase velocity on the retention properties of small analytes and large biomolecules in ultra-high pressure liquid chromatography
    • Fekete S., Veuthey J.L., McCalley D.V., Guillarme D. The effect of pressure and mobile phase velocity on the retention properties of small analytes and large biomolecules in ultra-high pressure liquid chromatography. J. Chromatogr. A 2012, 1270:127-138.
    • (2012) J. Chromatogr. A , vol.1270 , pp. 127-138
    • Fekete, S.1    Veuthey, J.L.2    McCalley, D.V.3    Guillarme, D.4
  • 55
    • 84866926481 scopus 로고    scopus 로고
    • Effect of column dimension on observed column efficiency in very high pressure liquid chromatography
    • Wu N., Bradley A.C. Effect of column dimension on observed column efficiency in very high pressure liquid chromatography. J. Chromatogr. A 2012, 1261:113-120.
    • (2012) J. Chromatogr. A , vol.1261 , pp. 113-120
    • Wu, N.1    Bradley, A.C.2
  • 56
    • 79960368111 scopus 로고    scopus 로고
    • Modifying conventional high-performance liquid chromatography systems to achieve fast separations with fused-core columns: a case study
    • Alexander A.J., Waeghe T.J., Himes K.W., Tomasella F.P., Hooker T.F. Modifying conventional high-performance liquid chromatography systems to achieve fast separations with fused-core columns: a case study. J. Chromatogr. A 2011, 1218:5456-5469.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 5456-5469
    • Alexander, A.J.1    Waeghe, T.J.2    Himes, K.W.3    Tomasella, F.P.4    Hooker, T.F.5
  • 57
    • 79952179851 scopus 로고    scopus 로고
    • Structural variation of solid core and thickness of porous shell of 1.7 mum core-shell silica particles on chromatographic performance: narrow bore columns
    • Omamogho J.O., Hanrahan J.P., Tobin J., Glennon J.D. Structural variation of solid core and thickness of porous shell of 1.7 mum core-shell silica particles on chromatographic performance: narrow bore columns. J. Chromatogr. A 2011, 1218:1942-1953.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 1942-1953
    • Omamogho, J.O.1    Hanrahan, J.P.2    Tobin, J.3    Glennon, J.D.4
  • 58
    • 84857041374 scopus 로고    scopus 로고
    • Performance optimizing injection sequence for minimizing injection band broadening contributions in high efficiency liquid chromatographic separations
    • Sanchez A.C., Anspach J.A., Farkas T. Performance optimizing injection sequence for minimizing injection band broadening contributions in high efficiency liquid chromatographic separations. J. Chromatogr. A 2012, 1228:338-348.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 338-348
    • Sanchez, A.C.1    Anspach, J.A.2    Farkas, T.3
  • 59
    • 84859984807 scopus 로고    scopus 로고
    • Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6mm I.D. silica monolithic columns
    • Gritti F., Guiochon G. Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6mm I.D. silica monolithic columns. J. Chromatogr. A 2012, 1238:77-90.
    • (2012) J. Chromatogr. A , vol.1238 , pp. 77-90
    • Gritti, F.1    Guiochon, G.2
  • 60
    • 80054871764 scopus 로고    scopus 로고
    • Viscous fingering in packed chromatographic columns: non-linear dynamics
    • Rousseaux G., Martin M., De Wit A. Viscous fingering in packed chromatographic columns: non-linear dynamics. J. Chromatogr. A 2011, 1218:8353-8361.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 8353-8361
    • Rousseaux, G.1    Martin, M.2    De Wit, A.3
  • 61
    • 0018818408 scopus 로고
    • Gradient elution in liquid chromatography: XII. Optimization of conditions for gradient elution
    • Jandera P., Churacek J. Gradient elution in liquid chromatography: XII. Optimization of conditions for gradient elution. J. Chromatogr. 1980, 192:19-36.
    • (1980) J. Chromatogr. , vol.192 , pp. 19-36
    • Jandera, P.1    Churacek, J.2
  • 63
    • 0000254966 scopus 로고
    • Influence of organic modifiers on the retention behavior in reversed-phase liquid chromatography and its consequences for gradient elution
    • Schoenmakers P.J., Billiet H.A.H., De Galan L. Influence of organic modifiers on the retention behavior in reversed-phase liquid chromatography and its consequences for gradient elution. J. Chromatogr. 1979, 185:179-195.
    • (1979) J. Chromatogr. , vol.185 , pp. 179-195
    • Schoenmakers, P.J.1    Billiet, H.A.H.2    De Galan, L.3
  • 64
    • 49049152778 scopus 로고
    • Use of gradient elution for rapid selection of isocratic conditions in reversed-phase high-performance liquid chormatography
    • Schoenmakers P.J., Billiet H.A.H., De Galan L. Use of gradient elution for rapid selection of isocratic conditions in reversed-phase high-performance liquid chormatography. J. Chromatogr. 1981, 205:13-30.
    • (1981) J. Chromatogr. , vol.205 , pp. 13-30
    • Schoenmakers, P.J.1    Billiet, H.A.H.2    De Galan, L.3
  • 65
    • 0025737712 scopus 로고
    • Gradient elution methods for predicting isocratic conditions
    • Schoenmakers P.J., Bartha A., Billiet H.A.H. Gradient elution methods for predicting isocratic conditions. J. Chromatogr. 1991, 550:425-447.
    • (1991) J. Chromatogr. , vol.550 , pp. 425-447
    • Schoenmakers, P.J.1    Bartha, A.2    Billiet, H.A.H.3
  • 66
    • 49249142565 scopus 로고
    • Gradient elution in high-performance liquid chromatography. I. Theoretical basis for reversed-phase systems
    • Snyder L.R., Dolan J.W., Gant J.R. Gradient elution in high-performance liquid chromatography. I. Theoretical basis for reversed-phase systems. J. Chromatogr. 1979, 165:3-30.
    • (1979) J. Chromatogr. , vol.165 , pp. 3-30
    • Snyder, L.R.1    Dolan, J.W.2    Gant, J.R.3
  • 67
    • 0038998024 scopus 로고
    • Gradient elution in high-performance liquid chromatography. II. Practical application to reversed-phase systems
    • Dolan J.W., Gant J.R., Snyder L.R. Gradient elution in high-performance liquid chromatography. II. Practical application to reversed-phase systems. J. Chromatogr. 1979, 165:31-58.
    • (1979) J. Chromatogr. , vol.165 , pp. 31-58
    • Dolan, J.W.1    Gant, J.R.2    Snyder, L.R.3
  • 68
    • 0030069584 scopus 로고    scopus 로고
    • Initial experiments in high-performance liquid chromatographic method development. I. Use of a starting gradient run
    • Snyder L.R., Dolan J.W. Initial experiments in high-performance liquid chromatographic method development. I. Use of a starting gradient run. J. Chromatogr. A 1996, 721:3-14.
    • (1996) J. Chromatogr. A , vol.721 , pp. 3-14
    • Snyder, L.R.1    Dolan, J.W.2
  • 69
    • 37849007036 scopus 로고    scopus 로고
    • Method transfer for fast liquid chromatography in pharmaceutical analysis: application to short columns packed with small particle. Part II: gradient experiments
    • Guillarme D., Nguyen D.T., Rudaz S., Veuthey J.L. Method transfer for fast liquid chromatography in pharmaceutical analysis: application to short columns packed with small particle. Part II: gradient experiments. Eur. J. Pharm. Biopharm. 2008, 68:430-440.
    • (2008) Eur. J. Pharm. Biopharm. , vol.68 , pp. 430-440
    • Guillarme, D.1    Nguyen, D.T.2    Rudaz, S.3    Veuthey, J.L.4
  • 70
    • 33745107531 scopus 로고    scopus 로고
    • Dwell volume revisited
    • Dolan J.W. Dwell volume revisited. LCGC North Am. 2006, 24:458-466.
    • (2006) LCGC North Am. , vol.24 , pp. 458-466
    • Dolan, J.W.1
  • 71
    • 85067747445 scopus 로고    scopus 로고
    • School of Pharmaceutical Sciences, Pharmaceutical Analytical Chemistry, HPLC calculator download, (12.01.2013).
    • School of Pharmaceutical Sciences, Pharmaceutical Analytical Chemistry, HPLC calculator download, (12.01.2013). http://www.unige.ch/sciences/pharm/fanal/lcap/telechargement-en.htm.
  • 72
    • 0032513177 scopus 로고    scopus 로고
    • Maintaining fixed band spacing when changing column dimensions in gradient elution
    • Dolan J.W., Snyder L.R. Maintaining fixed band spacing when changing column dimensions in gradient elution. J. Chromatogr. A 1998, 799:21-34.
    • (1998) J. Chromatogr. A , vol.799 , pp. 21-34
    • Dolan, J.W.1    Snyder, L.R.2
  • 73
    • 85067743962 scopus 로고    scopus 로고
    • Agilent Technologies, Agilent 1290 Infinity LC with Intelligent System Emulation Technology, 2013, 5990-8670EN.
    • Agilent Technologies, Agilent 1290 Infinity LC with Intelligent System Emulation Technology, 2013, 5990-8670EN.
  • 74
    • 34547356103 scopus 로고    scopus 로고
    • Ultrahigh-pressure LC in pharmaceutical analysis: performance and practical issues
    • Dong M.W. Ultrahigh-pressure LC in pharmaceutical analysis: performance and practical issues. LCGC North Am. 2007, 25:656-666.
    • (2007) LCGC North Am. , vol.25 , pp. 656-666
    • Dong, M.W.1
  • 75
    • 84888392827 scopus 로고    scopus 로고
    • Ultra-high-pressure LC in pharmaceutical analysis: benefits, impacts and issues
    • John Wiley & Sons, Hoboken, New Jersey, R.L. Wixom, C.W. Gehrke (Eds.)
    • Dong M.W. Ultra-high-pressure LC in pharmaceutical analysis: benefits, impacts and issues. Chromatography: A Science of Discovery 2010, 328-332. John Wiley & Sons, Hoboken, New Jersey. R.L. Wixom, C.W. Gehrke (Eds.).
    • (2010) Chromatography: A Science of Discovery , pp. 328-332
    • Dong, M.W.1
  • 76
    • 0031569131 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns
    • MacNair J.E., Lewis K.C., Jorgenson J.W. Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns. Anal. Chem. 1997, 69:983-989.
    • (1997) Anal. Chem. , vol.69 , pp. 983-989
    • MacNair, J.E.1    Lewis, K.C.2    Jorgenson, J.W.3
  • 77
    • 0033082675 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0-micron particles
    • MacNair J.E., Patel K.D., Jorgenson J.W. Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0-micron particles. Anal. Chem. 1999, 71:700-708.
    • (1999) Anal. Chem. , vol.71 , pp. 700-708
    • MacNair, J.E.1    Patel, K.D.2    Jorgenson, J.W.3
  • 78
    • 11444269089 scopus 로고    scopus 로고
    • The use of micrometer-sized particles in ultrahigh pressure liquid chromatography
    • Jerkovich A.D., Mellors J.S., Jorgenson J.W. The use of micrometer-sized particles in ultrahigh pressure liquid chromatography. LCGC Eur. 2003, 16:20-23.
    • (2003) LCGC Eur. , vol.16 , pp. 20-23
    • Jerkovich, A.D.1    Mellors, J.S.2    Jorgenson, J.W.3
  • 79
    • 4544276272 scopus 로고    scopus 로고
    • Use of 1.5-microm porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography
    • Mellors J.S., Jorgenson J.W. Use of 1.5-microm porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography. Anal. Chem. 2004, 76:5441-5450.
    • (2004) Anal. Chem. , vol.76 , pp. 5441-5450
    • Mellors, J.S.1    Jorgenson, J.W.2
  • 80
    • 26444517328 scopus 로고    scopus 로고
    • Linear velocity surge caused by mobile-phase compression as a source of band broadening in isocratic ultrahigh-pressure liquid chromatography
    • Jerkovich A.D., Mellors J.S., Thompson J.W., Jorgenson J.W. Linear velocity surge caused by mobile-phase compression as a source of band broadening in isocratic ultrahigh-pressure liquid chromatography. Anal. Chem. 2005, 77:6292-6299.
    • (2005) Anal. Chem. , vol.77 , pp. 6292-6299
    • Jerkovich, A.D.1    Mellors, J.S.2    Thompson, J.W.3    Jorgenson, J.W.4
  • 81
    • 0000470652 scopus 로고    scopus 로고
    • Fast ultrahigh-pressure liquid chromatography: on-column UV and time-of-flight mass spectrometric detection
    • Lippert J.A., Xin B., Wu N., Lee M.L. Fast ultrahigh-pressure liquid chromatography: on-column UV and time-of-flight mass spectrometric detection. J. Microcol. Sep. 1999, 11:631-643.
    • (1999) J. Microcol. Sep. , vol.11 , pp. 631-643
    • Lippert, J.A.1    Xin, B.2    Wu, N.3    Lee, M.L.4
  • 82
    • 0035831394 scopus 로고    scopus 로고
    • Practical aspects of ultrahigh pressure capillary liquid chromatography
    • Wu N., Lippert J.A., Lee M.L. Practical aspects of ultrahigh pressure capillary liquid chromatography. J. Chromatogr. A 2001, 911:1-12.
    • (2001) J. Chromatogr. A , vol.911 , pp. 1-12
    • Wu, N.1    Lippert, J.A.2    Lee, M.L.3
  • 83
    • 0037841778 scopus 로고    scopus 로고
    • Synthesis of micron diameter polybutadiene-encapsulated non-porous zirconia particles for ultrahigh pressure liquid chromatography
    • Xiang Y., Yan B., McNeff C.V., Carr P.W., Lee M.L. Synthesis of micron diameter polybutadiene-encapsulated non-porous zirconia particles for ultrahigh pressure liquid chromatography. J. Chromatogr. A 2003, 1002:71-78.
    • (2003) J. Chromatogr. A , vol.1002 , pp. 71-78
    • Xiang, Y.1    Yan, B.2    McNeff, C.V.3    Carr, P.W.4    Lee, M.L.5
  • 84
    • 1842844253 scopus 로고    scopus 로고
    • Elevated-temperature ultrahigh-pressure liquid chromatography using very small polybutadiene-coated nonporous zirconia particles
    • Xiang Y., Yan B., Yue B., McNeff C.V., Carr P.W., Lee M.L. Elevated-temperature ultrahigh-pressure liquid chromatography using very small polybutadiene-coated nonporous zirconia particles. J. Chromatogr. A 2003, 983:83-89.
    • (2003) J. Chromatogr. A , vol.983 , pp. 83-89
    • Xiang, Y.1    Yan, B.2    Yue, B.3    McNeff, C.V.4    Carr, P.W.5    Lee, M.L.6
  • 85
    • 30744448972 scopus 로고    scopus 로고
    • Ultrahigh pressure liquid chromatography using elevated temperature
    • Xiang Y., Liu Y., Lee M.L. Ultrahigh pressure liquid chromatography using elevated temperature. J. Chromatogr. A 2006, 1104:198-202.
    • (2006) J. Chromatogr. A , vol.1104 , pp. 198-202
    • Xiang, Y.1    Liu, Y.2    Lee, M.L.3
  • 86
    • 33744953372 scopus 로고    scopus 로고
    • Use of ultra-performance liquid chromatography in pharmaceutical development
    • Wren S.A., Tchelitcheff P. Use of ultra-performance liquid chromatography in pharmaceutical development. J. Chromatogr. A 2006, 1119:140-146.
    • (2006) J. Chromatogr. A , vol.1119 , pp. 140-146
    • Wren, S.A.1    Tchelitcheff, P.2
  • 87
    • 37848999751 scopus 로고    scopus 로고
    • Fused-core particle technology as an alternative to sub-2-microm particles to achieve high separation efficiency with low backpressure
    • Cunliffe J.M., Maloney T.D. Fused-core particle technology as an alternative to sub-2-microm particles to achieve high separation efficiency with low backpressure. J. Sep. Sci. 2007, 30:3104-3109.
    • (2007) J. Sep. Sci. , vol.30 , pp. 3104-3109
    • Cunliffe, J.M.1    Maloney, T.D.2
  • 88
    • 0037418781 scopus 로고    scopus 로고
    • Safety concerns in ultrahigh pressure capillary liquid chromatography using air-driven pumps
    • Xiang Y., Maynes D.R., Lee M.L. Safety concerns in ultrahigh pressure capillary liquid chromatography using air-driven pumps. J. Chromatogr. A 2003, 991:189-196.
    • (2003) J. Chromatogr. A , vol.991 , pp. 189-196
    • Xiang, Y.1    Maynes, D.R.2    Lee, M.L.3
  • 89
    • 70449641110 scopus 로고    scopus 로고
    • A review of current trends and advances in modern bio-analytical methods: chromatography and sample preparation
    • Novakova L., Vlckova H. A review of current trends and advances in modern bio-analytical methods: chromatography and sample preparation. Anal. Chim. Acta 2009, 656:8-35.
    • (2009) Anal. Chim. Acta , vol.656 , pp. 8-35
    • Novakova, L.1    Vlckova, H.2
  • 91
    • 33749258520 scopus 로고    scopus 로고
    • Effects of the thermal heterogeneity of the column on chromatographic results
    • Gritti F., Guiochon G. Effects of the thermal heterogeneity of the column on chromatographic results. J. Chromatogr. A 2006, 1131:151-165.
    • (2006) J. Chromatogr. A , vol.1131 , pp. 151-165
    • Gritti, F.1    Guiochon, G.2
  • 92
    • 66149118617 scopus 로고    scopus 로고
    • Influence of viscous friction heating on the efficiency of columns operated under very high pressures
    • Gritti F., Martin M., Guiochon G. Influence of viscous friction heating on the efficiency of columns operated under very high pressures. Anal. Chem. 2009, 81:3365-3384.
    • (2009) Anal. Chem. , vol.81 , pp. 3365-3384
    • Gritti, F.1    Martin, M.2    Guiochon, G.3
  • 93
    • 33645975885 scopus 로고    scopus 로고
    • Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns
    • de Villiers A., Lauer H., Szucs R., Goodall S., Sandra P. Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns. J. Chromatogr. A 2006, 1113:84-91.
    • (2006) J. Chromatogr. A , vol.1113 , pp. 84-91
    • de Villiers, A.1    Lauer, H.2    Szucs, R.3    Goodall, S.4    Sandra, P.5
  • 94
    • 85067747007 scopus 로고    scopus 로고
    • Increasing productivity in the analysis of impurities of metoclopramide hydrochloride formulations using the Agilent 1920 Infinity LC system, Agilent Technologies Application Note, 5990-3981EN.
    • G. Vanhoenacker, F. David, P. Sandra, Increasing productivity in the analysis of impurities of metoclopramide hydrochloride formulations using the Agilent 1920 Infinity LC system, Agilent Technologies Application Note, 2009, 5990-3981EN.
    • (2009)
    • Vanhoenacker, G.1    David, F.2    Sandra, P.3
  • 95
    • 80053946563 scopus 로고    scopus 로고
    • Practical method transfer from high performance liquid chromatography to ultra-high performance liquid chromatography: the importance of frictional heating
    • Novakova L., Veuthey J.L., Guillarme D. Practical method transfer from high performance liquid chromatography to ultra-high performance liquid chromatography: the importance of frictional heating. J. Chromatogr. A 2011, 1218:7971-7981.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 7971-7981
    • Novakova, L.1    Veuthey, J.L.2    Guillarme, D.3
  • 97
    • 33947483485 scopus 로고
    • Comparison of theoretical limit of separating speed in gas and liquid chromatography
    • Giddings J.C. Comparison of theoretical limit of separating speed in gas and liquid chromatography. Anal. Chem. 1965, 37:60-63.
    • (1965) Anal. Chem. , vol.37 , pp. 60-63
    • Giddings, J.C.1
  • 98
    • 22144438718 scopus 로고    scopus 로고
    • Kinetic plots to directly compare the performance of LC supports
    • Desmet G., Gzil P., Clicq D. Kinetic plots to directly compare the performance of LC supports. LCGC Eur. 2005, 18:403-409.
    • (2005) LCGC Eur. , vol.18 , pp. 403-409
    • Desmet, G.1    Gzil, P.2    Clicq, D.3
  • 99
    • 44949180742 scopus 로고    scopus 로고
    • Comparison techniques for HPLC column performance
    • Desmet G. Comparison techniques for HPLC column performance. LCGC North Am. 2008, 21:310-320.
    • (2008) LCGC North Am. , vol.21 , pp. 310-320
    • Desmet, G.1
  • 100
    • 70350143076 scopus 로고    scopus 로고
    • Are short columns always the best option?
    • Desmet G., Cabooter D. Are short columns always the best option?. LCGC Eur. 2009, 22:70-77.
    • (2009) LCGC Eur. , vol.22 , pp. 70-77
    • Desmet, G.1    Cabooter, D.2
  • 101
    • 84857048746 scopus 로고    scopus 로고
    • Kinetic plot based comparison of the efficiency and peak capacity of high-performance liquid chromatography columns: theoretical background and selected examples
    • Broeckhoven K., Cabooter D., Eeltink S., Desmet G. Kinetic plot based comparison of the efficiency and peak capacity of high-performance liquid chromatography columns: theoretical background and selected examples. J. Chromatogr. A 2012, 1228:20-30.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 20-30
    • Broeckhoven, K.1    Cabooter, D.2    Eeltink, S.3    Desmet, G.4
  • 102
    • 33645666340 scopus 로고    scopus 로고
    • Practical constraints in the kinetic plot representation of chromatographic performance data: theory and application to experimental data
    • Desmet G., Clicq D., Nguyen D.T., Guillarme D., Rudaz S., Veuthey J.L., Vervoort N., Torok G., Cabooter D., Gzil P. Practical constraints in the kinetic plot representation of chromatographic performance data: theory and application to experimental data. Anal. Chem. 2006, 78:2150-2162.
    • (2006) Anal. Chem. , vol.78 , pp. 2150-2162
    • Desmet, G.1    Clicq, D.2    Nguyen, D.T.3    Guillarme, D.4    Rudaz, S.5    Veuthey, J.L.6    Vervoort, N.7    Torok, G.8    Cabooter, D.9    Gzil, P.10
  • 103
    • 84867900827 scopus 로고    scopus 로고
    • High-resolution separations of tryptic digest mixtures using core-shell particulate columns operated at 1,200bar
    • De Vos J., Stassen C., Vaast A., Desmet G., Eeltink S. High-resolution separations of tryptic digest mixtures using core-shell particulate columns operated at 1,200bar. J. Chromatogr. A 2012, 1264:57-62.
    • (2012) J. Chromatogr. A , vol.1264 , pp. 57-62
    • De Vos, J.1    Stassen, C.2    Vaast, A.3    Desmet, G.4    Eeltink, S.5
  • 104
    • 84865396625 scopus 로고    scopus 로고
    • Maximizing the peak capacity using coupled columns packed with 2.6 mum core-shell particles operated at 1200bar
    • Vaast A., De Vos J., Broeckhoven K., Verstraeten M., Eeltink S., Desmet G. Maximizing the peak capacity using coupled columns packed with 2.6 mum core-shell particles operated at 1200bar. J. Chromatogr. A 2012, 1256:72-79.
    • (2012) J. Chromatogr. A , vol.1256 , pp. 72-79
    • Vaast, A.1    De Vos, J.2    Broeckhoven, K.3    Verstraeten, M.4    Eeltink, S.5    Desmet, G.6
  • 105
    • 85067767320 scopus 로고    scopus 로고
    • Coupling ultra high-pressure liquid chromatography with mass spectrometry: constraints and possible applications
    • Rodriguez-Aller M., Gurny R., Veuthey J.L., Guillarme D. Coupling ultra high-pressure liquid chromatography with mass spectrometry: constraints and possible applications. J. Chromatogr. A 2012, 10.1016/j.chroma.2012.1009.1061.
    • (2012) J. Chromatogr. A
    • Rodriguez-Aller, M.1    Gurny, R.2    Veuthey, J.L.3    Guillarme, D.4
  • 106
    • 73249131951 scopus 로고    scopus 로고
    • Coupling high-pressure liquid chromatography with mass spectrometry
    • Guillarme D., Schappler J., Rudaz S., Veuthey J.L. Coupling high-pressure liquid chromatography with mass spectrometry. Trends Anal. Chem. 2010, 29:15-27.
    • (2010) Trends Anal. Chem. , vol.29 , pp. 15-27
    • Guillarme, D.1    Schappler, J.2    Rudaz, S.3    Veuthey, J.L.4
  • 107
    • 75949096893 scopus 로고    scopus 로고
    • Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography
    • Gritti F., Guiochon G. Performance of columns packed with the new shell Kinetex-C18 particles in gradient elution chromatography. J. Chromatogr. A 2010, 1217:1604-1615.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 1604-1615
    • Gritti, F.1    Guiochon, G.2
  • 108
    • 0033168524 scopus 로고    scopus 로고
    • High-throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12hours
    • Zweigenbaum J., Heinig K., Steinborner S., Wachs T., Henion J. High-throughput bioanalytical LC/MS/MS determination of benzodiazepines in human urine: 1000 samples per 12hours. Anal. Chem. 1999, 71:2294-2300.
    • (1999) Anal. Chem. , vol.71 , pp. 2294-2300
    • Zweigenbaum, J.1    Heinig, K.2    Steinborner, S.3    Wachs, T.4    Henion, J.5
  • 109
    • 19944388647 scopus 로고    scopus 로고
    • A protocol for high-throughput drug mixture quantitation: fast LC-MS or flow injection analysis-MS?
    • Yu K., Balogh M. A protocol for high-throughput drug mixture quantitation: fast LC-MS or flow injection analysis-MS?. LCGC North Am. 2001, 19:60-72.
    • (2001) LCGC North Am. , vol.19 , pp. 60-72
    • Yu, K.1    Balogh, M.2
  • 110
    • 0036815607 scopus 로고    scopus 로고
    • Multidimensionnal liquid chromatography in proteomic studies
    • Wehr T. Multidimensionnal liquid chromatography in proteomic studies. LCGC North Am. 2002, 20:954-962.
    • (2002) LCGC North Am. , vol.20 , pp. 954-962
    • Wehr, T.1
  • 111
    • 84864553469 scopus 로고    scopus 로고
    • Repeatability of the efficiency of columns packed with sub-3mum core-shell particles: Part I. 2.6mum Kinetex-C(18) particles in 4.6mm and 2.1mm×100mm column formats
    • Gritti F., Guiochon G. Repeatability of the efficiency of columns packed with sub-3mum core-shell particles: Part I. 2.6mum Kinetex-C(18) particles in 4.6mm and 2.1mm×100mm column formats. J. Chromatogr. A 2012, 1252:31-44.
    • (2012) J. Chromatogr. A , vol.1252 , pp. 31-44
    • Gritti, F.1    Guiochon, G.2
  • 112
    • 84864530278 scopus 로고    scopus 로고
    • Repeatability of the efficiency of columns packed with sub-3mum core-shell particles: Part II. 2.7mum Halo-ES-Peptide-C18 particles in 4.6mm and 2.1mm×100mm column formats
    • Gritti F., Guiochon G. Repeatability of the efficiency of columns packed with sub-3mum core-shell particles: Part II. 2.7mum Halo-ES-Peptide-C18 particles in 4.6mm and 2.1mm×100mm column formats. J. Chromatogr. A 2012, 1252:45-55.
    • (2012) J. Chromatogr. A , vol.1252 , pp. 45-55
    • Gritti, F.1    Guiochon, G.2
  • 113
    • 84864533321 scopus 로고    scopus 로고
    • Repeatability of the efficiency of columns packed with sub-3mum core-shell particles: Part III. 2.7mum Poroshell 120 EC-C18 particles in 4.6mm and 2.1mm ×100mm column formats
    • Gritti F., Guiochon G. Repeatability of the efficiency of columns packed with sub-3mum core-shell particles: Part III. 2.7mum Poroshell 120 EC-C18 particles in 4.6mm and 2.1mm ×100mm column formats. J. Chromatogr. A 2012, 1252:56-66.
    • (2012) J. Chromatogr. A , vol.1252 , pp. 56-66
    • Gritti, F.1    Guiochon, G.2
  • 114
    • 85067748755 scopus 로고    scopus 로고
    • System optimization manual, (06.02.2013).
    • System optimization manual, (06.02.2013). https://phenomenex.blob.core.windows.net/documents/ad6882fd-5ad1-478a-ab0a-5ad746734529.pdf.
  • 115
    • 48949098856 scopus 로고    scopus 로고
    • Kinetic plot equations for evaluating the real performance of the combined use of high temperature and ultra-high pressure in liquid chromatography. Application to commercial instruments and 2.1 and 1mm I.D. columns
    • Heinisch S., Desmet G., Clicq D., Rocca J.L. Kinetic plot equations for evaluating the real performance of the combined use of high temperature and ultra-high pressure in liquid chromatography. Application to commercial instruments and 2.1 and 1mm I.D. columns. J. Chromatogr. A 2008, 1203:124-136.
    • (2008) J. Chromatogr. A , vol.1203 , pp. 124-136
    • Heinisch, S.1    Desmet, G.2    Clicq, D.3    Rocca, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.