메뉴 건너뛰기




Volumn 73, Issue 1, 2015, Pages 223-232

Comparison of myelin water fraction from multiecho T2 decay curve and steady-state methods

Author keywords

McDESPOT; Myelin water fraction; Steady state imaging; T2 relaxation

Indexed keywords

HEALTHY VOLUNTEERS; MCDESPOT; MULTICOMPONENTS; MYELIN WATER FRACTIONS; RADIO FREQUENCY FIELDS; STEADY STATE; STEADY-STATE METHOD; T2 RELAXATION;

EID: 84919837381     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.25125     Document Type: Article
Times cited : (76)

References (39)
  • 1
    • 0004214945 scopus 로고
    • 2nd ed. New York: Plenum Press
    • Morell P. Myelin. 2nd ed. New York: Plenum Press; 1984.
    • (1984) Myelin
    • Morell, P.1
  • 3
  • 4
    • 0001182288 scopus 로고
    • Quantitative interpretation of NMR relaxation data
    • Whittall KP, MacKay AL. Quantitative interpretation of NMR relaxation data. J Magn Reson 1989;84:134-152.
    • (1989) J Magn Reson , vol.84 , pp. 134-152
    • Whittall, K.P.1    MacKay, A.L.2
  • 5
    • 33845660319 scopus 로고    scopus 로고
    • Normal-Appearing white matter in patients with phenylketonuria: Water content, myelin water fraction, and metabolite concentrations
    • Sirrs SM, Laule C, Mädler B, Brief EE, Tahir SA, Bishop C, MacKay AL. Normal-Appearing white matter in patients with phenylketonuria: water content, myelin water fraction, and metabolite concentrations. Radiology 2007;242:236-243.
    • (2007) Radiology , vol.242 , pp. 236-243
    • Sirrs, S.M.1    Laule, C.2    Mädler, B.3    Brief, E.E.4    Tahir, S.A.5    Bishop, C.6    MacKay, A.L.7
  • 8
    • 0027258743 scopus 로고
    • Spinspin relaxation in experimental allergic encephalomyelitis. Analysis of CPMG data using a non-linear least squares method and linear inverse theory
    • Stewart WA, MacKay AL, Whittall KP, Moore GR, Paty DW. Spinspin relaxation in experimental allergic encephalomyelitis. Analysis of CPMG data using a non-linear least squares method and linear inverse theory. Magn Reson Med 1993;29:767-775.
    • (1993) Magn Reson Med , vol.29 , pp. 767-775
    • Stewart, W.A.1    MacKay, A.L.2    Whittall, K.P.3    Moore, G.R.4    Paty, D.W.5
  • 10
    • 41649098819 scopus 로고    scopus 로고
    • Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
    • Laule C, Kozlowski P, Leung E, Li DKB, Mackay AL, Moore GRW. Myelin water imaging of multiple sclerosis at 7 T: correlations with histopathology. Neuroimage 2008;40:1575-1580.
    • (2008) Neuroimage , vol.40 , pp. 1575-1580
    • Laule, C.1    Kozlowski, P.2    Leung, E.3    Li, D.K.B.4    Mackay, A.L.5    Moore, G.R.W.6
  • 11
    • 77950618784 scopus 로고    scopus 로고
    • Multiexponential T2, magnetization transfer, and quantitative histology in white matter tracts of rat spinal cord
    • Dula AN, Gochberg DF, Valentine HL, Valentine WM, Does MD. Multiexponential T2, magnetization transfer, and quantitative histology in white matter tracts of rat spinal cord. Magn Reson Med 2010;63:902-909.
    • (2010) Magn Reson Med , vol.63 , pp. 902-909
    • Dula, A.N.1    Gochberg, D.F.2    Valentine, H.L.3    Valentine, W.M.4    Does, M.D.5
  • 14
    • 34247238858 scopus 로고    scopus 로고
    • Multislice brain myelin water fractions at 3{T} in multiple sclerosis
    • Oh J, Han E, Lee M, Nelson S, Pelletier D. Multislice brain myelin water fractions at 3{T} in multiple sclerosis. J Neuroimaging 2007;17:156-63.
    • (2007) J Neuroimaging , vol.17 , pp. 156-163
    • Oh, J.1    Han, E.2    Lee, M.3    Nelson, S.4    Pelletier, D.5
  • 15
    • 10744226835 scopus 로고    scopus 로고
    • Abnormalities of myelination in schizophrenia detected in vivo with MRI, and post-mortem with analysis of oligodendrocyte proteins
    • Flynn SW, Lang DJ, Mackay AL, et al. Abnormalities of myelination in schizophrenia detected in vivo with MRI, and post-mortem with analysis of oligodendrocyte proteins. Mol Psychiatry 2003;8:811-820.
    • (2003) Mol Psychiatry , vol.8 , pp. 811-820
    • Flynn, S.W.1    Lang, D.J.2    Mackay, A.L.3
  • 19
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Deoni SCL, Rutt BK, Peters TM. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003;49:515-526.
    • (2003) Magn Reson Med , vol.49 , pp. 515-526
    • Deoni, S.C.L.1    Rutt, B.K.2    Peters, T.M.3
  • 20
    • 57149110446 scopus 로고    scopus 로고
    • Gleaning multicomponent T1 and T2 information from steady-state imaging data
    • Deoni SCL, Rutt BK, Arun T, Pierpaoli C, Jones DK. Gleaning multicomponent T1 and T2 information from steady-state imaging data. Magn Reson Med 2008;60:1372-1387.
    • (2008) Magn Reson Med , vol.60 , pp. 1372-1387
    • Deoni, S.C.L.1    Rutt, B.K.2    Arun, T.3    Pierpaoli, C.4    Jones, D.K.5
  • 21
    • 78651498671 scopus 로고    scopus 로고
    • Rapid three-dimensional multicomponent relaxation imaging of the cervical spinal cord
    • Kolind SH, Deoni SC. Rapid three-dimensional multicomponent relaxation imaging of the cervical spinal cord. Magn Reson Med 2011;65:551-556.
    • (2011) Magn Reson Med , vol.65 , pp. 551-556
    • Kolind, S.H.1    Deoni, S.C.2
  • 22
    • 84866024322 scopus 로고    scopus 로고
    • Investigating white matter development in infancy and early childhood using myelin water faction and relaxation time mapping
    • Deoni SCL, Dean DC 3rd, O'Muircheartaigh J, Dirks H, Jerskey BA. Investigating white matter development in infancy and early childhood using myelin water faction and relaxation time mapping. Neuroimage 2012;63:1038-1053.
    • (2012) Neuroimage , vol.63 , pp. 1038-1053
    • Deoni, S.C.L.1    Dean, D.C.2    O'Muircheartaigh, J.3    Dirks, H.4    Jerskey, B.A.5
  • 24
    • 79952791696 scopus 로고    scopus 로고
    • Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium singlepulse observation of T1 and T2
    • Deoni SCL. Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium singlepulse observation of T1 and T2. Magn Reson Med 2011;65:1021-1035.
    • (2011) Magn Reson Med , vol.65 , pp. 1021-1035
    • Deoni, S.C.L.1
  • 26
    • 84861227345 scopus 로고    scopus 로고
    • Applications of stimulated echo correction to multicomponent T2 analysis
    • Prasloski T, Mädler B, Xiang Q-S, MacKay A, Jones C. Applications of stimulated echo correction to multicomponent T2 analysis. Magn Reson Med 2012;67:1803-1814.
    • (2012) Magn Reson Med , vol.67 , pp. 1803-1814
    • Prasloski, T.1    Mädler, B.2    Xiang, Q.-S.3    MacKay, A.4    Jones, C.5
  • 28
    • 35148865818 scopus 로고    scopus 로고
    • High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
    • Deoni SCL. High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI). J Magn Reson Imaging 2007;26:1106-1111.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1106-1111
    • Deoni, S.C.L.1
  • 29
    • 3543134876 scopus 로고    scopus 로고
    • Rapid T2 estimation with phase-cycled variable nutation steady-state free precession
    • Deoni SCL, Ward HA, Peters TM, Rutt BK. Rapid T2 estimation with phase-cycled variable nutation steady-state free precession. Magn Reson Med 2004;52:435-439.
    • (2004) Magn Reson Med , vol.52 , pp. 435-439
    • Deoni, S.C.L.1    Ward, H.A.2    Peters, T.M.3    Rutt, B.K.4
  • 30
    • 0026258703 scopus 로고
    • Microphone array optimization by stochastic region contraction
    • Berger MF, Silverman HF. Microphone array optimization by stochastic region contraction. IEEE Trans Signal Process 1991;39:2377-2386.
    • (1991) IEEE Trans Signal Process , vol.39 , pp. 2377-2386
    • Berger, M.F.1    Silverman, H.F.2
  • 31
    • 49349118272 scopus 로고
    • The measurement of cross-relaxation effects in the proton NMR spin-lattice relaxation of water in biological systems: Hydrated collagen and muscle
    • Edzes HT, Samulski ET. The measurement of cross-relaxation effects in the proton NMR spin-lattice relaxation of water in biological systems: hydrated collagen and muscle. J Magn Reson 1978;31:207-229.
    • (1978) J Magn Reson , vol.31 , pp. 207-229
    • Edzes, H.T.1    Samulski, E.T.2
  • 32
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Martin Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;327:307-310.
    • (1986) Lancet , vol.327 , pp. 307-310
    • Martin Bland, J.1    Altman, D.2
  • 34
    • 84879414396 scopus 로고    scopus 로고
    • One component? Two components? Three? The effect of including a nonexchanging "free" water component in multicomponent driven equilibrium single pulse observation of T1 and T2
    • Deoni SCL, Matthews L, Kolind SH. One component? Two components? Three? The effect of including a nonexchanging "free" water component in multicomponent driven equilibrium single pulse observation of T1 and T2. Magn Reson Med 2013;70:147-154.
    • (2013) Magn Reson Med , vol.70 , pp. 147-154
    • Deoni, S.C.L.1    Matthews, L.2    Kolind, S.H.3
  • 35
    • 77956395177 scopus 로고    scopus 로고
    • Limitations of rapid myelin water quantification using 3D bSSFP
    • Lenz C, Klarhöfer M, Scheffler K. Limitations of rapid myelin water quantification using 3D bSSFP. MAGMA 2010;23:139-151.
    • (2010) MAGMA , vol.23 , pp. 139-151
    • Lenz, C.1    Klarhöfer, M.2    Scheffler, K.3
  • 36
    • 70449371825 scopus 로고    scopus 로고
    • SSFP signal with finite RF pulses
    • Bieri O, Scheffler K. SSFP signal with finite RF pulses. Magn Reson Med 2009;62:1232-1241.
    • (2009) Magn Reson Med , vol.62 , pp. 1232-1241
    • Bieri, O.1    Scheffler, K.2
  • 37
    • 84872872374 scopus 로고    scopus 로고
    • On the inherent precision of mcDESPOT
    • Lankford CL, Does MD. On the inherent precision of mcDESPOT. Magn Reson Med 2013;69:127-136.
    • (2013) Magn Reson Med , vol.69 , pp. 127-136
    • Lankford, C.L.1    Does, M.D.2
  • 38
    • 73349083009 scopus 로고    scopus 로고
    • Quantitative T2 analysis: The effects of noise, regularization, and multivoxel approaches
    • Bjarnason TA, McCreary CR, Dunn JF, Mitchell JR. Quantitative T2 analysis: the effects of noise, regularization, and multivoxel approaches. Magn Reson Med 2010;63:212-217.
    • (2010) Magn Reson Med , vol.63 , pp. 212-217
    • Bjarnason, T.A.1    McCreary, C.R.2    Dunn, J.F.3    Mitchell, J.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.