-
1
-
-
33645301309
-
Assessment of the strategies for reducing VOCs emission from polyurea-formaldehyde resin synthetic fiber leather industry in Taiwan
-
C.T. Chang, and K.L. Lin Assessment of the strategies for reducing VOCs emission from polyurea-formaldehyde resin synthetic fiber leather industry in Taiwan Resour. Conserv. Recycl. 46 2006 321 334
-
(2006)
Resour. Conserv. Recycl.
, vol.46
, pp. 321-334
-
-
Chang, C.T.1
Lin, K.L.2
-
2
-
-
84884552034
-
A high sensitivity gas sensor for formaldehyde based on silver doped lanthanum ferrite
-
Y.M. Zhang, Y.T. Lin, J.L. Chen, J. Zhang, Z.Q. Zhu, and Q.J. Liu A high sensitivity gas sensor for formaldehyde based on silver doped lanthanum ferrite Sens. Actuators B 190 2014 171 176
-
(2014)
Sens. Actuators B
, vol.190
, pp. 171-176
-
-
Zhang, Y.M.1
Lin, Y.T.2
Chen, J.L.3
Zhang, J.4
Zhu, Z.Q.5
Liu, Q.J.6
-
3
-
-
33745947028
-
Fish and food safety: Determination of formaldehyde in 12 fish species by SPME extraction and GC-MS analysis
-
F. Bianchi, M. Careri, M. Musci, and A. Mangia Fish and food safety: determination of formaldehyde in 12 fish species by SPME extraction and GC-MS analysis Food Chem. 100 2007 1049 1053
-
(2007)
Food Chem.
, vol.100
, pp. 1049-1053
-
-
Bianchi, F.1
Careri, M.2
Musci, M.3
Mangia, A.4
-
4
-
-
66149132977
-
Microwave-assisted extraction coupled online with derivatization, restricted access material cleanup, and high-performance liquid chromatography for determination of formaldehyde in aquatic products
-
L. Chen, H. Jin, H. Xu, L. Sun, A. Yu, H. Zhang, and L. Ding Microwave-assisted extraction coupled online with derivatization, restricted access material cleanup, and high-performance liquid chromatography for determination of formaldehyde in aquatic products J. Agric. Food Chem. 57 2009 3989 3994
-
(2009)
J. Agric. Food Chem.
, vol.57
, pp. 3989-3994
-
-
Chen, L.1
Jin, H.2
Xu, H.3
Sun, L.4
Yu, A.5
Zhang, H.6
Ding, L.7
-
5
-
-
84862799530
-
A longitudinal study of aldehydes and volatile organic compounds associated with subjective symptoms related to sick building syndrome in new dwellings in Japan
-
T. Takigawa, Y. Saijo, K. Morimoto, K. Nakayama, E. Shibata, M. Tanaka, T. Yoshimura, H. Chikara, and R. Kishi A longitudinal study of aldehydes and volatile organic compounds associated with subjective symptoms related to sick building syndrome in new dwellings in Japan Sci. Total Environ. 417-418 2012 61 67
-
(2012)
Sci. Total Environ.
, vol.417-418
, pp. 61-67
-
-
Takigawa, T.1
Saijo, Y.2
Morimoto, K.3
Nakayama, K.4
Shibata, E.5
Tanaka, M.6
Yoshimura, T.7
Chikara, H.8
Kishi, R.9
-
6
-
-
25844483804
-
Summary of IARC monographs on formaldehydes 2-butoxyethanol and 1-tert-butoxy-2-propanol
-
V.J. Cogliano, Y. Grosse, R.A. Bean, K. Straif, M.B. Secretan, and F. El Ghissassi Summary of IARC monographs on formaldehydes 2-butoxyethanol and 1-tert-butoxy-2-propanol Environ. Health Perspect. 113 2005 1205 1208
-
(2005)
Environ. Health Perspect.
, vol.113
, pp. 1205-1208
-
-
Cogliano, V.J.1
Grosse, Y.2
Bean, R.A.3
Straif, K.4
Secretan, M.B.5
El Ghissassi, F.6
-
7
-
-
34548496281
-
Formaldehyde 2-butoxyethanol and 1-tert-butoxy-2-propanol in evaluating carcinogenic
-
IARC Formaldehyde 2-butoxyethanol and 1-tert-butoxy-2-propanol in evaluating carcinogenic Risk. Hum. 88 2005 37 325
-
(2005)
Risk. Hum.
, vol.88
, pp. 37-325
-
-
Iarc1
-
9
-
-
0034707717
-
A piezoelectric method for monitoring formaldehyde induced crosslink formation between polylysine and poly-deoxyhuanosine
-
R.L. Bunde, E.J. Jarvi, and J.J. Rosebtreter A piezoelectric method for monitoring formaldehyde induced crosslink formation between polylysine and poly-deoxyhuanosine Talanta 51 2000 159 171
-
(2000)
Talanta
, vol.51
, pp. 159-171
-
-
Bunde, R.L.1
Jarvi, E.J.2
Rosebtreter, J.J.3
-
10
-
-
0037017564
-
A biosensor for monitoring formaldehyde using a new lipophilic tetrathiafulvalene-tetracyanoquinodimethane salt and a polyurethane membrane
-
R. Kataky, M.R. Bryce, L. Goldenberg, S. Hayes, and A. Novak A biosensor for monitoring formaldehyde using a new lipophilic tetrathiafulvalene-tetracyanoquinodimethane salt and a polyurethane membrane Talanta 56 2002 451 458
-
(2002)
Talanta
, vol.56
, pp. 451-458
-
-
Kataky, R.1
Bryce, M.R.2
Goldenberg, L.3
Hayes, S.4
Novak, A.5
-
11
-
-
84899462074
-
Electrospun nanofibrous chitosan membranes modified with polyethyleneimine for formaldehyde detection
-
N. Wang, X. Wang, Y. Jia, X. Li, J. Yu, and B. Ding Electrospun nanofibrous chitosan membranes modified with polyethyleneimine for formaldehyde detection Carbohydr. Polym. 108 2014 192 199
-
(2014)
Carbohydr. Polym.
, vol.108
, pp. 192-199
-
-
Wang, N.1
Wang, X.2
Jia, Y.3
Li, X.4
Yu, J.5
Ding, B.6
-
12
-
-
84861379626
-
Amine-functionalized SBA-15 with uniform morphology and well-defined mesostructure for highly sensitive chemosensors to detect formaldehyde vapor
-
Y.H. Zhu, H. Li, Q. Zheng, J.Q. Xu, and X.X. Li Amine-functionalized SBA-15 with uniform morphology and well-defined mesostructure for highly sensitive chemosensors to detect formaldehyde vapor Langmuir 28 2012 7843 7850
-
(2012)
Langmuir
, vol.28
, pp. 7843-7850
-
-
Zhu, Y.H.1
Li, H.2
Zheng, Q.3
Xu, J.Q.4
Li, X.X.5
-
13
-
-
84902440116
-
Rapid analysis of trace volatile formaldehyde in aquatic products by derivatization reaction-based surface enhanced Raman spectroscopy
-
Z. Zhang, C. Zhao, Y. Ma, and G. Li Rapid analysis of trace volatile formaldehyde in aquatic products by derivatization reaction-based surface enhanced Raman spectroscopy Analyst 139 2014 3614 3621
-
(2014)
Analyst
, vol.139
, pp. 3614-3621
-
-
Zhang, Z.1
Zhao, C.2
Ma, Y.3
Li, G.4
-
14
-
-
76849091676
-
MOF-5 metal-organic framework as sorbent for in-field sampling and preconcentration in combination with thermal desorption GC/MS for determination of atmospheric formaldehyde
-
Z.Y. Gu, G. Wang, and X.P. Yan MOF-5 metal-organic framework as sorbent for in-field sampling and preconcentration in combination with thermal desorption GC/MS for determination of atmospheric formaldehyde Anal. Chem. 82 2010 1365 1370
-
(2010)
Anal. Chem.
, vol.82
, pp. 1365-1370
-
-
Gu, Z.Y.1
Wang, G.2
Yan, X.P.3
-
15
-
-
84875834216
-
Detection of formaldehyde vapor using conductive polymer films
-
S. Antwi-Boampong, and J.J. BelBruno Detection of formaldehyde vapor using conductive polymer films Sens. Actuators B 182 2013 300 306
-
(2013)
Sens. Actuators B
, vol.182
, pp. 300-306
-
-
Antwi-Boampong, S.1
Belbruno, J.J.2
-
16
-
-
10844234636
-
Determination of formaldehyde in shiitake mushroom by ionic liquid-based liquid-phase microextraction coupled with liquid chromatography
-
J.F. Liu, J.F. Peng, Y.G. Chi, and G.B. Jiang Determination of formaldehyde in shiitake mushroom by ionic liquid-based liquid-phase microextraction coupled with liquid chromatography Talanta 65 2005 705 709
-
(2005)
Talanta
, vol.65
, pp. 705-709
-
-
Liu, J.F.1
Peng, J.F.2
Chi, Y.G.3
Jiang, G.B.4
-
17
-
-
84875130823
-
Transportable, fast and high sensitive near real-time analyzers: Formaldehyde detection
-
A. Allouch, M. Guglielmino, P. Bernhardt, C.A. Serra, and S. Le Calve Transportable, fast and high sensitive near real-time analyzers: formaldehyde detection Sens. Actuators B 181 2013 551 558
-
(2013)
Sens. Actuators B
, vol.181
, pp. 551-558
-
-
Allouch, A.1
Guglielmino, M.2
Bernhardt, P.3
Serra, C.A.4
Le Calve, S.5
-
18
-
-
84884233207
-
Fabrication of a Au@SnO2 core-shell structure for gaseous formaldehyde sensing at room temperature
-
F.C. Chung, R.J. Wu, and F.C. Cheng Fabrication of a Au@SnO2 core-shell structure for gaseous formaldehyde sensing at room temperature Sens. Actuators B 190 2014 1 7
-
(2014)
Sens. Actuators B
, vol.190
, pp. 1-7
-
-
Chung, F.C.1
Wu, R.J.2
Cheng, F.C.3
-
19
-
-
40749090882
-
A bio-sniffer stick with FALDH (formaldehydedehydrogenase) for convenient analysis of gaseous formaldehyde
-
K. Mitsubayashi, G. Nishio, M. Sawai, T. Saito, H. Kudo, H. Saito, K. Otsuka, T. Noguer, and I.-L. Marty A bio-sniffer stick with FALDH (formaldehydedehydrogenase) for convenient analysis of gaseous formaldehyde Sens. Actuators B 130 2008 32 37
-
(2008)
Sens. Actuators B
, vol.130
, pp. 32-37
-
-
Mitsubayashi, K.1
Nishio, G.2
Sawai, M.3
Saito, T.4
Kudo, H.5
Saito, H.6
Otsuka, K.7
Noguer, T.8
Marty, I.-L.9
-
20
-
-
47749094627
-
Reagentless amperometric formaldehyde-selective biosensors based on the recombinant yeast formaldehyde dehydrogenase
-
O. Demkiv, O. Smutok, S. Paryzhak, G. Gayda, Y. Sultanov, D. Guschin, H. Shkil, W. Schuhmann, and M. Gonchar Reagentless amperometric formaldehyde-selective biosensors based on the recombinant yeast formaldehyde dehydrogenase Talanta 76 2008 837 846
-
(2008)
Talanta
, vol.76
, pp. 837-846
-
-
Demkiv, O.1
Smutok, O.2
Paryzhak, S.3
Gayda, G.4
Sultanov, Y.5
Guschin, D.6
Shkil, H.7
Schuhmann, W.8
Gonchar, M.9
-
21
-
-
0030480210
-
Direct monitoring of formaldehyde vapour and detection of ethanol vapour using dehydrogenase-based biosensors
-
M.J. Dennison, J.M. Hall, and A.P.F. Turner Direct monitoring of formaldehyde vapour and detection of ethanol vapour using dehydrogenase-based biosensors Analyst 121 1996 1769 1773
-
(1996)
Analyst
, vol.121
, pp. 1769-1773
-
-
Dennison, M.J.1
Hall, J.M.2
Turner, A.P.F.3
-
22
-
-
84901767915
-
Zeolitic imidazolate framework as formaldehyde gas sensor
-
E.X. Chen, H. Yang, and J. Zhang Zeolitic imidazolate framework as formaldehyde gas sensor Inorg. Chem. 53 2014 5411 5413
-
(2014)
Inorg. Chem.
, vol.53
, pp. 5411-5413
-
-
Chen, E.X.1
Yang, H.2
Zhang, J.3
-
23
-
-
84903708410
-
A colorimetric agarose gel for formaldehyde measurement based on nanotechnology involving Tollens reaction
-
J.B. Zeng, S.G. Fan, C.Y. Zhao, Q.R. Wang, T.Y. Zhou, X. Chen, Z.F. Yan, Y.P. Li, W. Xing, and X.D. Wang A colorimetric agarose gel for formaldehyde measurement based on nanotechnology involving Tollens reaction Chem. Commun. 50 2014 8121 8123
-
(2014)
Chem. Commun.
, vol.50
, pp. 8121-8123
-
-
Zeng, J.B.1
Fan, S.G.2
Zhao, C.Y.3
Wang, Q.R.4
Zhou, T.Y.5
Chen, X.6
Yan, Z.F.7
Li, Y.P.8
Xing, W.9
Wang, X.D.10
-
24
-
-
84863338318
-
Fluorescent chemosensors based on spiroring-opening of xanthenes and related derivatives
-
X. Chen, T. Pradhan, F. Wang, J.S. Kim, and J. Yoon Fluorescent chemosensors based on spiroring-opening of xanthenes and related derivatives Chem. Rev. 112 2012 1910 1956
-
(2012)
Chem. Rev.
, vol.112
, pp. 1910-1956
-
-
Chen, X.1
Pradhan, T.2
Wang, F.3
Kim, J.S.4
Yoon, J.5
-
25
-
-
33947177182
-
A self-heating gas sensor with integrated NiO thin-film for formaldehyde detection
-
C.-Y. Lee, C.-M. Chiang, Y.-H. Wang, and R.-H. Ma A self-heating gas sensor with integrated NiO thin-film for formaldehyde detection Sens. Actuators B 122 2007 503 510
-
(2007)
Sens. Actuators B
, vol.122
, pp. 503-510
-
-
Lee, C.-Y.1
Chiang, C.-M.2
Wang, Y.-H.3
Ma, R.-H.4
-
26
-
-
76949107085
-
Silicon-based micro-gas sensors for detecting formaldehyde
-
J. Wang, P. Zhang, J.-Q. Qi, and P.-J. Yao Silicon-based micro-gas sensors for detecting formaldehyde Sens. Actuators B 136 2009 399 404
-
(2009)
Sens. Actuators B
, vol.136
, pp. 399-404
-
-
Wang, J.1
Zhang, P.2
Qi, J.-Q.3
Yao, P.-J.4
-
27
-
-
77953143274
-
Effective analysis of gaseous formaldehyde based on a platinum-deposited screen-printed edge band ultramicroelectrode coated with Nafion as solid polymer electrolyte
-
C.-H. Chou, J.-L. Chang, and J.-M. Zen Effective analysis of gaseous formaldehyde based on a platinum-deposited screen-printed edge band ultramicroelectrode coated with Nafion as solid polymer electrolyte Sens. Actuators B 147 2010 669 675
-
(2010)
Sens. Actuators B
, vol.147
, pp. 669-675
-
-
Chou, C.-H.1
Chang, J.-L.2
Zen, J.-M.3
-
28
-
-
51649098666
-
An enrichment method to detect low concentration formaldehyde
-
J. Wang, L. Liu, S.-Y. Cong, J.-Q. Qi, and B.-K. Xu An enrichment method to detect low concentration formaldehyde Sens. Actuators B 134 2008 1010 1015
-
(2008)
Sens. Actuators B
, vol.134
, pp. 1010-1015
-
-
Wang, J.1
Liu, L.2
Cong, S.-Y.3
Qi, J.-Q.4
Xu, B.-K.5
-
30
-
-
78650628136
-
Real-time detection of formaldehyde by a fluorescence-based sensor
-
M.N. Descamps, T. Bordy, J. Hue, S. Mariano, G. Nonglation, E. Schultz, T.H. Tran-Thi, and S. Vignoud-Despond Real-time detection of formaldehyde by a fluorescence-based sensor Procedia Eng. 5 2010 1009 1012
-
(2010)
Procedia Eng.
, vol.5
, pp. 1009-1012
-
-
Descamps, M.N.1
Bordy, T.2
Hue, J.3
Mariano, S.4
Nonglation, G.5
Schultz, E.6
Tran-Thi, T.H.7
Vignoud-Despond, S.8
-
31
-
-
84864965137
-
Real-time detection of formaldehyde by a sensor
-
M.N. Descamps, T. Bordy, J. Hue, S. Mariano, G. Nonglation, E. Schultz, T.H. Tran-Thi, and S. Vignoud-Despond Real-time detection of formaldehyde by a sensor Sens. Actuators B 170 2012 104 108
-
(2012)
Sens. Actuators B
, vol.170
, pp. 104-108
-
-
Descamps, M.N.1
Bordy, T.2
Hue, J.3
Mariano, S.4
Nonglation, G.5
Schultz, E.6
Tran-Thi, T.H.7
Vignoud-Despond, S.8
-
32
-
-
84865044430
-
A tailor designed fluorescent 'turn-on' sensor of formaldehyde based on the BODIPY motif
-
H. Song, S. Rajendiran, N. Kim, S.K. Jeong, E. Koo, G. Park, T.D. Thangadurai, and S. Yoon A tailor designed fluorescent 'turn-on' sensor of formaldehyde based on the BODIPY motif Tetrahedron Lett. 53 2012 4913 4916
-
(2012)
Tetrahedron Lett.
, vol.53
, pp. 4913-4916
-
-
Song, H.1
Rajendiran, S.2
Kim, N.3
Jeong, S.K.4
Koo, E.5
Park, G.6
Thangadurai, T.D.7
Yoon, S.8
-
34
-
-
84869424975
-
2+-selective fluorescent chemosensor with different charge transfer processses
-
2+-selective fluorescent chemosensor with different charge transfer processses Inorg. Chem. 51 2012 12444 12449
-
(2012)
Inorg. Chem.
, vol.51
, pp. 12444-12449
-
-
Li, Z.1
Zhao, W.2
Li, X.3
Zhu, Y.4
Liu, C.5
Wang, L.6
Yu, M.7
Wei, L.8
Tang, M.9
Zhang, H.10
-
35
-
-
47149102166
-
Reconfigurable cascade circuit in a photo- and chemical-switchable fluorescent diarylethene derivative
-
Z.X. Li, L.Y. Liao, W. Sun, C.H. Xu, C. Zhang, C.J. Fang, and C.H. Yan Reconfigurable cascade circuit in a photo- and chemical-switchable fluorescent diarylethene derivative J. Phys. Chem. C 112 2008 5190 5196
-
(2008)
J. Phys. Chem. C
, vol.112
, pp. 5190-5196
-
-
Li, Z.X.1
Liao, L.Y.2
Sun, W.3
Xu, C.H.4
Zhang, C.5
Fang, C.J.6
Yan, C.H.7
|