메뉴 건너뛰기




Volumn 130, Issue 1, 2008, Pages 32-37

A bio-sniffer stick with FALDH (formaldehyde dehydrogenase) for convenient analysis of gaseous formaldehyde

Author keywords

Bio sniffer; Biosensor; Building materials; Formaldehyde vapor; Gas selectivity; Sniffer stick; VOC

Indexed keywords

AMPEROMETRIC SENSORS; ENZYMES; FORMALDEHYDE;

EID: 40749090882     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.07.086     Document Type: Article
Times cited : (63)

References (22)
  • 1
    • 40749093948 scopus 로고    scopus 로고
    • T. Yoshida, Revision and trend measures of preventive a bad smell code, N.T.S Co., Ltd., Tokyo, 1996, p. 16.
    • T. Yoshida, Revision and trend measures of preventive a bad smell code, N.T.S Co., Ltd., Tokyo, 1996, p. 16.
  • 2
    • 33745085116 scopus 로고    scopus 로고
    • Methods for measurements of indoor air pollution by formaldehyde and volatile organic compounds in residentioal buildings
    • Yamaguchi K., and Okada H. Methods for measurements of indoor air pollution by formaldehyde and volatile organic compounds in residentioal buildings. Environ. Measur. Technol. 6 (1999) 63
    • (1999) Environ. Measur. Technol. , vol.6 , pp. 63
    • Yamaguchi, K.1    Okada, H.2
  • 3
    • 40749162638 scopus 로고    scopus 로고
    • Jap. Environmental & Sanitary Center Ed, A report of chemical malodor analysis (a study for the Japan Enviromental Agency), 1980, pp. 248-250.
    • Jap. Environmental & Sanitary Center Ed, A report of chemical malodor analysis (a study for the Japan Enviromental Agency), 1980, pp. 248-250.
  • 4
    • 33947477650 scopus 로고
    • A new detector for gaseous components using semiconductive thin films
    • Seiyama T., Kato A., Fujiishi K., and Nagatani M. A new detector for gaseous components using semiconductive thin films. Anal. Chem. 34 (1962) 1502-1506
    • (1962) Anal. Chem. , vol.34 , pp. 1502-1506
    • Seiyama, T.1    Kato, A.2    Fujiishi, K.3    Nagatani, M.4
  • 5
    • 0023849922 scopus 로고
    • Current status and future view of development for odorant sensors
    • Tonoike M. Current status and future view of development for odorant sensors. Bull. Electrotechn. Lab. 52 5 (1988) 63-79
    • (1988) Bull. Electrotechn. Lab. , vol.52 , Issue.5 , pp. 63-79
    • Tonoike, M.1
  • 8
    • 0026896695 scopus 로고
    • 3: solubility limit and the effect of doping on the resistivity and ethanol sensitivity
    • 3: solubility limit and the effect of doping on the resistivity and ethanol sensitivity. Sens. Actuators B 9 (1992) 49-53
    • (1992) Sens. Actuators B , vol.9 , pp. 49-53
    • Chen, Z.1    Colbow, K.2
  • 9
    • 0027594648 scopus 로고
    • An integrated array of multiple thin-film metal oxide sensors for quantification of individual components in organic vapor mixtures
    • Wang X., Yee S., and Carey P. An integrated array of multiple thin-film metal oxide sensors for quantification of individual components in organic vapor mixtures. Sens. Actuators B 13-14 (1993) 458-461
    • (1993) Sens. Actuators B , vol.13-14 , pp. 458-461
    • Wang, X.1    Yee, S.2    Carey, P.3
  • 10
    • 40749092702 scopus 로고    scopus 로고
    • Acetaldehyde sensing properties of oxide semiconductor gas sensor
    • Hyodo T., Kohyama M., Shimizu Y., and Egashira M. Acetaldehyde sensing properties of oxide semiconductor gas sensor. Chemical Sensors 16 (Supplement A) (2000) 10-12
    • (2000) Chemical Sensors , vol.16 SUPPL. A , pp. 10-12
    • Hyodo, T.1    Kohyama, M.2    Shimizu, Y.3    Egashira, M.4
  • 11
    • 0030480210 scopus 로고    scopus 로고
    • Direct monitoring offormaldehyde vapour and detection of ethanol vapour using dehydrogenase-basedbiosensors
    • Dennison M.J., Hall J.M., and Turner A.P.F. Direct monitoring offormaldehyde vapour and detection of ethanol vapour using dehydrogenase-basedbiosensors. Analyst 121 (1996) 1769-1773
    • (1996) Analyst , vol.121 , pp. 1769-1773
    • Dennison, M.J.1    Hall, J.M.2    Turner, A.P.F.3
  • 12
    • 0028999650 scopus 로고
    • An amperometric bienzyme electrode for acetaldehyde detection
    • Noguer T., and Marty J.L. An amperometric bienzyme electrode for acetaldehyde detection. Enzyme Microb. Technol. 17 (1995) 453-459
    • (1995) Enzyme Microb. Technol. , vol.17 , pp. 453-459
    • Noguer, T.1    Marty, J.L.2
  • 13
    • 0030751273 scopus 로고    scopus 로고
    • High sensitive bienzymic sensor for the detection of dithiocarbamate fungicides
    • Noguer T., and Marty J.L. High sensitive bienzymic sensor for the detection of dithiocarbamate fungicides. Anal. Chim. Acta 347 (1997) 63-70
    • (1997) Anal. Chim. Acta , vol.347 , pp. 63-70
    • Noguer, T.1    Marty, J.L.2
  • 15
    • 0037086220 scopus 로고    scopus 로고
    • Bioelectronic nose for methyl mercaptan vapor using xenobiotic metabolizing enzyme: flavin-containing monooxygenase
    • Mitsubayashi K., and Hashimoto Y. Bioelectronic nose for methyl mercaptan vapor using xenobiotic metabolizing enzyme: flavin-containing monooxygenase. Sens. Actuators B 83 (2002) 35-40
    • (2002) Sens. Actuators B , vol.83 , pp. 35-40
    • Mitsubayashi, K.1    Hashimoto, Y.2
  • 16
    • 0042938862 scopus 로고    scopus 로고
    • Bioelectronic sniffer device for trimethylamine vapor using flavin containing monooxygenase
    • Mitsubayashi K., and Hashimoto Y. Bioelectronic sniffer device for trimethylamine vapor using flavin containing monooxygenase. IEEE Sens. J. 2 3 (2002) 133-139
    • (2002) IEEE Sens. J. , vol.2 , Issue.3 , pp. 133-139
    • Mitsubayashi, K.1    Hashimoto, Y.2
  • 18
    • 0021529356 scopus 로고
    • A convenient photochemical method to immobilize enzymes
    • Ichimura K. A convenient photochemical method to immobilize enzymes. J. Polym. Sci. 22 (1984) 2817-2828
    • (1984) J. Polym. Sci. , vol.22 , pp. 2817-2828
    • Ichimura, K.1
  • 19
    • 0032919430 scopus 로고    scopus 로고
    • Determination of breath alcohol using a differential-type amperometric biosensor based on alcohol dehydrogenase
    • Park J.K., Yee H.J., Lee K.S., Lee W.Y., Shin M.C., Kim T.H., and Kim S.R. Determination of breath alcohol using a differential-type amperometric biosensor based on alcohol dehydrogenase. Anal. Chim. Acta 390 1-3 (1999) 83-91
    • (1999) Anal. Chim. Acta , vol.390 , Issue.1-3 , pp. 83-91
    • Park, J.K.1    Yee, H.J.2    Lee, K.S.3    Lee, W.Y.4    Shin, M.C.5    Kim, T.H.6    Kim, S.R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.