3
-
-
0020434377
-
Determination of formaldehyde and other aldehydes in automobile exhaust with an improved 2,4-dinitrophenyl-hydrazine method
-
F. Lipari, and S.J. Swarin Determination of formaldehyde and other aldehydes in automobile exhaust with an improved 2,4-dinitrophenylhydrazine method Journal of Chromatography A 247 1982 297 306 (Pubitemid 13203399)
-
(1982)
Journal of Chromatography
, vol.247
, Issue.2
, pp. 297-306
-
-
Lipari, F.1
Swarin, S.J.2
-
5
-
-
40749090882
-
A bio-sniffer stick with FALDH (formaldehyde dehydrogenase) for convenient analysis of gaseous formaldehyde
-
DOI 10.1016/j.snb.2007.07.086, PII S0925400507005436
-
K. Mitsubayashi, G. Nishio, M. Sawai, T. Saito, H. Kudo, and H. Saito A bio-sniffer stick with FALDH (formaldehyde dehydrogenase) for convenient analysis of gaseous formaldehyde Sensors and Actuators B: Chemical 130 2008 32 37 (Pubitemid 351380382)
-
(2008)
Sensors and Actuators, B: Chemical
, vol.130
, Issue.1
, pp. 32-37
-
-
Mitsubayashi, K.1
Nishio, G.2
Sawai, M.3
Saito, T.4
Kudo, H.5
Saito, H.6
Otsuka, K.7
Noguer, T.8
Marty, J.-L.9
-
6
-
-
33748142850
-
Formaldehyde measurements in libraries: Comparison between infrared diode laser spectroscopy and a DNPH-derivatization method
-
DOI 10.1016/j.atmosenv.2006.05.017, PII S1352231006004961
-
B. Hanoune, T. LeBris, L. Allou, C. Marchand, and S. Le Calvé Formaldehyde measurements in libraries: comparison between infrared diode laser spectroscopy and a DNPH-derivatization method Atmospheric Environment 40 2006 5768 5775 (Pubitemid 44311059)
-
(2006)
Atmospheric Environment
, vol.40
, Issue.30
, pp. 5768-5775
-
-
Hanoune, B.1
LeBris, T.2
Allou, L.3
Marchand, C.4
Le Calve, S.5
-
7
-
-
21244481002
-
Air formaldehyde and solvent concentrations during surface coating with acid-curing lacquers and paints in the woodworking and furniture industry
-
DOI 10.1039/b418887j
-
S. Thorud, M. Gjolstad, D.G. Ellingsen, and P. Molander Air formaldehyde and solvent concentrations during surface coating with acid-curing lacquers and paints in the woodworking and furniture industry Journal of Environmental Monitoring 7 2005 586 591 (Pubitemid 40896060)
-
(2005)
Journal of Environmental Monitoring
, vol.7
, Issue.6
, pp. 586-591
-
-
Thorud, S.1
Gjolstad, M.2
Ellingsen, D.G.3
Molander, P.4
-
8
-
-
78651449987
-
Liquid-phase microextraction with in-drop derivatization combined with microvolume fluorospectrometry for free and hydrolyzed formaldehyde determination in textile samples
-
M. Saenz, J. Alvarado, F. Pena-Pereira, S. Senra-Ferreiro, I. Lavilla, and C. Bendicho Liquid-phase microextraction with in-drop derivatization combined with microvolume fluorospectrometry for free and hydrolyzed formaldehyde determination in textile samples Analytica Chimica Acta 687 2011 50 55
-
(2011)
Analytica Chimica Acta
, vol.687
, pp. 50-55
-
-
Saenz, M.1
Alvarado, J.2
Pena-Pereira, F.3
Senra-Ferreiro, S.4
Lavilla, I.5
Bendicho, C.6
-
10
-
-
0037454741
-
Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa, Mexico
-
DOI 10.1016/S0048-9697(02)00344-3, PII S0048969702003443
-
A. Baez, H. Padilla, R. Garcia, Md.C. Torres, I. Rosas, and R. Belmont Carbonyl levels in indoor and outdoor air in Mexico City and Xalapa Mexico Science of The Total Environment 302 2003 211 226 (Pubitemid 36071299)
-
(2003)
Science of the Total Environment
, vol.302
, Issue.1-3
, pp. 211-226
-
-
Baez, A.1
Padilla, H.2
Garcia, R.3
Torres, M.D.C.4
Rosas, I.5
Belmont, R.6
-
11
-
-
67749106471
-
Assessment and predictor determination of indoor aldehyde levels in Paris newborn babies' homes
-
C. Dassonville, C. Demattei, A.M. Laurent, Y. Le Moullec, N. Seta, and I. Momas Assessment and predictor determination of indoor aldehyde levels in Paris newborn babies' homes Indoor Air 19 2009 314 323
-
(2009)
Indoor Air
, vol.19
, pp. 314-323
-
-
Dassonville, C.1
Demattei, C.2
Laurent, A.M.3
Le Moullec, Y.4
Seta, N.5
Momas, I.6
-
12
-
-
65949085369
-
Formaldehyde and volatile organic compounds in Hong Kong homes: Concentrations and impact factors
-
H. Guo, N.H. Kwok, H.R. Cheng, S.C. Lee, W.T. Hung, and Y.S. Li Formaldehyde and volatile organic compounds in Hong Kong homes: concentrations and impact factors Indoor Air 19 2009 206 217
-
(2009)
Indoor Air
, vol.19
, pp. 206-217
-
-
Guo, H.1
Kwok, N.H.2
Cheng, H.R.3
Lee, S.C.4
Hung, W.T.5
Li, Y.S.6
-
13
-
-
31044444887
-
Aldehyde measurements in indoor environments in Strasbourg (France)
-
DOI 10.1016/j.atmosenv.2005.10.027, PII S1352231005010034
-
C. Marchand, B. Bulliot, S. Le Calvé, and P. Mirabel Aldehyde measurements in indoor environments in Strasbourg (France) Atmospheric Environment 40 2006 1336 1345 (Pubitemid 43120755)
-
(2006)
Atmospheric Environment
, vol.40
, Issue.7
, pp. 1336-1345
-
-
Marchand, C.1
Bulliot, B.2
Le Calve, S.3
Mirabel, P.4
-
15
-
-
84864965137
-
Real-time detection of formaldehyde by a sensor
-
M.N. Descamps, T. Bordy, J. Hue, S. Mariano, G. Nonglaton, and E. Schultz Real-time detection of formaldehyde by a sensor Sensors and Actuators B: Chemical 170 2012 104 108
-
(2012)
Sensors and Actuators B: Chemical
, vol.170
, pp. 104-108
-
-
Descamps, M.N.1
Bordy, T.2
Hue, J.3
Mariano, S.4
Nonglaton, G.5
Schultz, E.6
-
17
-
-
33845377084
-
Determination of sub-part-per-million levels of formaldehyde in air using active or passive sampling on 2,4-dinitrophenylhydrazine-coated glass fiber filters and high-performance liquid chromatography
-
J. Levin, K. Andersson, R. Linndahl, and C. Nilsson Determination of sub-parts-per-million levels of formaldehyde in air using active and passive sampling on 2,4-dinitrophenylhydrazine coated glass fibre and high-performance liquid chromatography Analytical Chemistry 57 1985 1032 1035 (Pubitemid 15077644)
-
(1985)
Analytical Chemistry
, vol.57
, Issue.6
, pp. 1032-1035
-
-
Levin, J.-O.1
Andersson, K.2
Lindahl, R.3
Nilsson, C.-A.4
-
18
-
-
0038739304
-
A simplified apparatus for ambient formaldehyde detection via GC-pHID
-
DOI 10.1016/S1352-2310(03)00178-X
-
J.R. Hopkins, T. Still, S. Al-Haider, I.R. Fisher, A.C. Lewis, and P.W. Seakins A simplified apparatus for ambient formaldehyde detection via GC-pHID Atmospheric Environment 37 2003 2557 2565 (Pubitemid 36561444)
-
(2003)
Atmospheric Environment
, vol.37
, Issue.18
, pp. 2557-2565
-
-
Hopkins, J.R.1
Still, T.2
Al-Haider, S.3
Fisher, I.R.4
Lewis, A.C.5
Seakins, P.W.6
-
19
-
-
0019596772
-
Determination of formaldehyde in clean air
-
DOI 10.1021/es00089a007
-
D.C. Lowe, U. Schmidt, D.H. Ehhalt, C.G.B. Frischkom, and H.W. Nürnberg Determination of formaldehyde in clean air Environmental Science and Technology 15 1981 819 823 (Pubitemid 11009928)
-
(1981)
Environmental Science and Technology
, vol.15
, Issue.7
, pp. 819-823
-
-
Lowe, D.C.1
Schmidt, U.2
Ehhalt, D.H.3
-
20
-
-
33947177182
-
A self-heating gas sensor with integrated NiO thin-film for formaldehyde detection
-
DOI 10.1016/j.snb.2006.06.018, PII S0925400506004552
-
C.-Y. Lee, C.-M. Chiang, Y.-H. Wang, and R.-H. Ma A self-heating gas sensor with integrated NiO thin-film for formaldehyde detection Sensors and Actuators B: Chemical 122 2007 503 510 (Pubitemid 46401210)
-
(2007)
Sensors and Actuators, B: Chemical
, vol.122
, Issue.2
, pp. 503-510
-
-
Lee, C.-Y.1
Chiang, C.-M.2
Wang, Y.-H.3
Ma, R.-H.4
-
22
-
-
77953143274
-
Effective analysis of gaseous formaldehyde based on a platinum-deposited screen-printed edge band ultramicroelectrode coated with Nafion as solid polymer electrolyte
-
C.-H. Chou, J.-L. Chang, and J.-M. Zen Effective analysis of gaseous formaldehyde based on a platinum-deposited screen-printed edge band ultramicroelectrode coated with Nafion as solid polymer electrolyte Sensors and Actuators B: Chemical 147 2010 669 675
-
(2010)
Sensors and Actuators B: Chemical
, vol.147
, pp. 669-675
-
-
Chou, C.-H.1
Chang, J.-L.2
Zen, J.-M.3
-
23
-
-
51649098666
-
An enrichment method to detect low concentration formaldehyde
-
J. Wang, L. Liu, S.-Y. Cong, J.-Q. Qi, and B.-K. Xu An enrichment method to detect low concentration formaldehyde Sensors and Actuators B: Chemical 134 2008 1010 1015
-
(2008)
Sensors and Actuators B: Chemical
, vol.134
, pp. 1010-1015
-
-
Wang, J.1
Liu, L.2
Cong, S.-Y.3
Qi, J.-Q.4
Xu, B.-K.5
-
24
-
-
43749118183
-
2-NiO sensitive film for indoor formaldehyde detection
-
DOI 10.1016/j.snb.2008.01.018, PII S0925400508000282
-
2-NiO sensitive film for indoor formaldehyde detection Sensors and Actuators B: Chemical 132 2008 74 80 (Pubitemid 351694406)
-
(2008)
Sensors and Actuators, B: Chemical
, vol.132
, Issue.1
, pp. 74-80
-
-
Lv, P.1
Tang, Z.A.2
Yu, J.3
Zhang, F.T.4
Wei, G.F.5
Huang, Z.X.6
Hu, Y.7
-
25
-
-
70350394909
-
Highly sensitive gaseous formaldehyde sensor with CdTe quantum dots multilayer films
-
Q. Ma, H. Cui, and X. Su Highly sensitive gaseous formaldehyde sensor with CdTe quantum dots multilayer films Biosensors and Bioelectronics 25 2009 839 844
-
(2009)
Biosensors and Bioelectronics
, vol.25
, pp. 839-844
-
-
Ma, Q.1
Cui, H.2
Su, X.3
-
27
-
-
84875158769
-
-
http://www.arb.ca.gov/airways/crpaqs/STI/AppA11.pdf
-
-
-
-
28
-
-
0033140258
-
An automatic monitor of formaldehyde in air by a monitoring tape method
-
N. Nakano, and K. Nagashima An automatic monitor of formaldehyde in air by a monitoring tape method Journal of Environmental Monitoring 1 1999 255 258 (Pubitemid 129503940)
-
(1999)
Journal of Environmental Monitoring
, vol.1
, Issue.3
, pp. 255-258
-
-
Nakano, N.1
Nagashima, K.2
-
29
-
-
0348012951
-
Portable Sick House Syndrome Gas Monitoring System Based on Novel Colorimetric Reagents for the Highly Selective and Sensitive Detection of Formaldehyde
-
DOI 10.1021/es0305050
-
Y. Suzuki, N. Nakano, and K. Suzuki Portable sick house syndrome gas monitoring system based on novel colorimetric reagents for the highly selective and sensitive detection of formaldehyde Environmental Science and Technology 37 2003 5695 5700 (Pubitemid 37541742)
-
(2003)
Environmental Science and Technology
, vol.37
, Issue.24
, pp. 5695-5700
-
-
Suzuki, Y.1
Nakano, N.2
Suzuki, K.3
-
31
-
-
38949143987
-
Development of formaldehyde sensing element using porous glass impregnated with Schiff's reagent
-
DOI 10.1016/j.snb.2007.09.002, PII S0925400507006946
-
Y.Y. Maruo, J. Nakamura, M. Uchiyama, M. Higuchi, and K. Izumi Development of formaldehyde sensing element using porous glass impregnated with Schiff's reagent Sensors and Actuators B: Chemical 129 2008 544 550 (Pubitemid 351221262)
-
(2008)
Sensors and Actuators, B: Chemical
, vol.129
, Issue.2
, pp. 544-550
-
-
Maruo, Y.Y.1
Nakamura, J.2
Uchiyama, M.3
Higuchi, M.4
Izumi, K.5
-
32
-
-
38149044112
-
Development of formaldehyde sensing element using porous glass impregnated with beta-diketone
-
Y.Y. Maruo, J. Nakamura, and M. Uchiyama Development of formaldehyde sensing element using porous glass impregnated with beta-diketone Talanta 74 2008 1141 1147
-
(2008)
Talanta
, vol.74
, pp. 1141-1147
-
-
Maruo, Y.Y.1
Nakamura, J.2
Uchiyama, M.3
-
33
-
-
78349291493
-
Formaldehyde measurements in residential indoor air using a developed sensor element in the Kanto area of Japan
-
Y.Y. Maruo, T. Yamada, J. Nakamura, K. Izumi, and M. Uchiyama Formaldehyde measurements in residential indoor air using a developed sensor element in the Kanto area of Japan Indoor Air 20 2010 486 493
-
(2010)
Indoor Air
, vol.20
, pp. 486-493
-
-
Maruo, Y.Y.1
Yamada, T.2
Nakamura, J.3
Izumi, K.4
Uchiyama, M.5
-
34
-
-
80051472236
-
Portable formaldehyde monitoring device using porous glass sensor and its applications in indoor air quality studies
-
Y.Y. Maruo, and J. Nakamura Portable formaldehyde monitoring device using porous glass sensor and its applications in indoor air quality studies Analytica Chimica Acta 702 2011 247 253
-
(2011)
Analytica Chimica Acta
, vol.702
, pp. 247-253
-
-
Maruo, Y.Y.1
Nakamura, J.2
-
35
-
-
78650596450
-
Colorimetric detection of formaldehyde: A sensor for air quality measurements and a pollution-warning kit for homes
-
S. Mariano, W. Wang, G. Brunelle, Y. Bigay, and T.H. Tran-Thi Colorimetric detection of formaldehyde: a sensor for air quality measurements and a pollution-warning kit for homes Procedia Engineering 5 2010 1184 1187
-
(2010)
Procedia Engineering
, vol.5
, pp. 1184-1187
-
-
Mariano, S.1
Wang, W.2
Brunelle, G.3
Bigay, Y.4
Tran-Thi, T.H.5
-
36
-
-
72249086070
-
Sol-gel based sensor for selective formaldehyde determination
-
O. Bunkoed, F. Davis, P. Kanatharana, P. Thavarungkul, and S.P.J Higson Sol-gel based sensor for selective formaldehyde determination Analytica Chimica Acta 659 2010 251 257
-
(2010)
Analytica Chimica Acta
, vol.659
, pp. 251-257
-
-
Bunkoed, O.1
Davis, F.2
Kanatharana, P.3
Thavarungkul, P.4
Higson, P.J.5
-
37
-
-
3142688177
-
Continuous fluorescence determination of formaldehyde in air
-
DOI 10.1016/j.aca.2004.05.033, PII S0003267004006427
-
K. Motyka, and P. Mikuska Continuous fluorescence determination of formaldehyde in air Analytica Chimica Acta 518 2004 51 57 (Pubitemid 38917054)
-
(2004)
Analytica Chimica Acta
, vol.518
, Issue.1-2
, pp. 51-57
-
-
Motyka, K.1
Mikuska, P.2
-
38
-
-
13844281289
-
Portable system for near-real time measurement of gaseous formaldehyde by means of parallel scrubber stopped-flow absorptiometry
-
DOI 10.1016/j.aca.2004.08.070, PII S0003267004011511
-
K. Toda, K.-I. Yoshioka, K. Mori, and S. Hirata Portable system for near-real time measurement of gaseous formaldehyde by means of parallel scrubber stopped-flow absorptiometry Analytica Chimica Acta 531 2005 41 49 (Pubitemid 40255172)
-
(2005)
Analytica Chimica Acta
, vol.531
, Issue.1
, pp. 41-49
-
-
Toda, K.1
Yoshioka, K.-I.2
Mori, K.3
Hirata, S.4
-
39
-
-
0346496493
-
Determination of nitrite by flow injection spectrophotometry using a home-made
-
S. Hirata, B.V. Amma, S. Karthikeyan, and K. Toda Determination of nitrite by flow injection spectrophotometry using a home-made Analytical Sciences 19 2003 687 689
-
(2003)
Analytical Sciences
, vol.19
, pp. 687-689
-
-
Hirata, S.1
Amma, B.V.2
Karthikeyan, S.3
Toda, K.4
-
40
-
-
46149101171
-
On-site determination of formaldehyde: A low cost measurement device for museum environments
-
L.T. Gibson, W.J. Kerr, A. Nordon, J. Reglinski, C. Robertson, and L. Turnbull On-site determination of formaldehyde: a low cost measurement device for museum environments Analytica Chimica Acta 623 2008 109 116
-
(2008)
Analytica Chimica Acta
, vol.623
, pp. 109-116
-
-
Gibson, L.T.1
Kerr, W.J.2
Nordon, A.3
Reglinski, J.4
Robertson, C.5
Turnbull, L.6
-
41
-
-
84860785580
-
Mobile monitoring along a street canyon and stationary forest air monitoring of formaldehyde by means of a micro-gas analysis system
-
K. Toda, W. Tokunaga, Y. Gushiken, K. Hirota, T. Nose, and D. Suda Mobile monitoring along a street canyon and stationary forest air monitoring of formaldehyde by means of a micro-gas analysis system Journal of Environmental Monitoring 14 2012 1462 1472
-
(2012)
Journal of Environmental Monitoring
, vol.14
, pp. 1462-1472
-
-
Toda, K.1
Tokunaga, W.2
Gushiken, Y.3
Hirota, K.4
Nose, T.5
Suda, D.6
-
42
-
-
79955471566
-
Henry's law constant measurements for formaldehyde and benzaldehyde as a function of temperature and water composition
-
L. Allou, L. El Maimouni, and S. Le Calvé Henry's law constant measurements for formaldehyde and benzaldehyde as a function of temperature and water composition Atmospheric Environment 45 2011 2991 2998
-
(2011)
Atmospheric Environment
, vol.45
, pp. 2991-2998
-
-
Allou, L.1
El Maimouni, L.2
Le Calvé, S.3
-
44
-
-
46549089960
-
Micro gas analyzers for environmental and medical applications
-
S.-I. Ohira, and K. Toda Micro gas analyzers for environmental and medical applications Analytica Chimica Acta 619 2008 143 156
-
(2008)
Analytica Chimica Acta
, vol.619
, pp. 143-156
-
-
Ohira, S.-I.1
Toda, K.2
|