A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging

Author keywords

C arm fluoroscopy; Image stitching; Multi planar radiography; Quantitative C arm; TC arm; Tracked C arm

Indexed keywords

ACCURACY; ANATOMIC LANDMARK; ARTICLE; CALIBRATION; COMPUTER INTERFACE; ELECTRONIC SENSOR; FEMUR; FLUOROSCOPY; FLUOROSCOPY SYSTEM; IMAGE RECONSTRUCTION; IMAGING PHANTOM; INTRAOPERATIVE PERIOD; KINEMATICS; LUMBAR SPINE; PANORAMIC RADIOGRAPHY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; THREE DIMENSIONAL IMAGING; TRACKED C ARM SYSTEM;

EID: 84908545027     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-013-0957-9     Document Type: Article
Times cited : (16)

References (36)
  • 1
    • 0032822724 scopus 로고    scopus 로고
    • Fluoroscopy as an imaging means for computer-assisted surgical navigation
    • COI: 1:STN:280:DyaK1MvisFequw%3D%3D
    • Hofstetter R, Slomczykowski M, Sati M (1999) Fluoroscopy as an imaging means for computer-assisted surgical navigation. Comput Aid Surg 4(2):65–76
    • (1999) Comput Aid Surg , vol.4 , Issue.2 , pp. 65-76
    • Hofstetter, R.1    Slomczykowski, M.2    Sati, M.3
  • 3
    • 0034523472 scopus 로고    scopus 로고
    • Hofstetter R, Slomczykowski M, Krettek C, Koppen G, Sati M, Nolte LP (2000) Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction. Comput Aid Surg 5(5):311–325
    • Hofstetter R, Slomczykowski M, Krettek C, Koppen G, Sati M, Nolte LP (2000) Computer-assisted fluoroscopy-based reduction of femoral fractures and antetorsion correction. Comput Aid Surg 5(5):311–325. doi:10.1002/1097-0150(2000)5:5<311:Aid-Igs1>3.0.Co;2-J
  • 4
    • 17644405424 scopus 로고    scopus 로고
    • Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model
    • PID: 15795574
    • Collinge C, Coons D, Tornetta P, Aschenbrenner J (2005) Standard multiplanar fluoroscopy versus a fluoroscopically based navigation system for the percutaneous insertion of iliosacral screws: a cadaver model. J Orthop Trauma 19(4):254–258
    • (2005) J Orthop Trauma , vol.19 , Issue.4 , pp. 254-258
    • Collinge, C.1    Coons, D.2    Tornetta, P.3    Aschenbrenner, J.4
  • 5
    • 0035865652 scopus 로고    scopus 로고
    • Virtual fluoroscopy: computer-assisted fluoroscopic navigation
    • Foley KT, Simon DA, Rampersaud YR (2001) Virtual fluoroscopy: computer-assisted fluoroscopic navigation. Spine 26(4):347–351
    • (2001) Spine , vol.26 , Issue.4 , pp. 347-351
    • Foley, K.T.1    Simon, D.A.2    Rampersaud, Y.R.3
  • 6
    • 2342574698 scopus 로고    scopus 로고
    • Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants
    • PID: 15135275
    • Suhm N, Messmer P, Zuna I, Regazzoni P (2004) Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants. Injury 35(6):567–574. doi:10.1016/S0020-1383(03)00312-7
    • (2004) Injury , vol.35 , Issue.6 , pp. 567-574
    • Suhm, N.1    Messmer, P.2    Zuna, I.3    Regazzoni, P.4
  • 7
    • 84871964324 scopus 로고    scopus 로고
    • Precise X-ray and video overlay for augmented reality fluoroscopy
    • COI: 1:CAS:528:DC%2BC3sXhtVKgtbnP, PID: 22592259
    • Chen X, Wang L, Fallavollita P, Navab N (2013) Precise X-ray and video overlay for augmented reality fluoroscopy. Int J Comput Assist Radiol Surg 8(1):29–38. doi:10.1007/S11548-012-0746-X
    • (2013) Int J Comput Assist Radiol Surg , vol.8 , Issue.1 , pp. 29-38
    • Chen, X.1    Wang, L.2    Fallavollita, P.3    Navab, N.4
  • 10
    • 84867527618 scopus 로고    scopus 로고
    • A multiplanar radiography method for assessing cup orientation in total hip arthroplasty
    • Amiri S, Masri BA, Garbuz D, Anglin C, Wilson DR (2012) A multiplanar radiography method for assessing cup orientation in total hip arthroplasty. J Biomech Eng 134(10):101008. doi:10.1115/1.4007664
    • (2012) J Biomech Eng 134(10)
    • Amiri, S.1    Masri, B.A.2    Garbuz, D.3    Anglin, C.4    Wilson, D.R.5
  • 11
    • 79956159795 scopus 로고    scopus 로고
    • A novel multi-planar radiography method for three dimensional pose reconstruction of the patellofemoral and tibiofemoral joints after arthroplasty
    • Amiri S, Wilson DR, Masri BA, Sharma G, Anglin C (2011) A novel multi-planar radiography method for three dimensional pose reconstruction of the patellofemoral and tibiofemoral joints after arthroplasty. J Biomech 44(9):1757–1764. doi:10.1016/J.Jbiomech.2011.04.006
    • (2011) J Biomech , vol.44 , Issue.9 , pp. 1757-1764
    • Amiri, S.1    Wilson, D.R.2    Masri, B.A.3    Sharma, G.4    Anglin, C.5
  • 12
    • 84859917069 scopus 로고    scopus 로고
    • A model-free feature-based bi-planar RSA method for kinematic analysis of total knee arthroplasty
    • Amiri S, Anglin C, Agbanlog K, Masri BA, Wilson DR (2012) A model-free feature-based bi-planar RSA method for kinematic analysis of total knee arthroplasty. J Biomech Eng 134(3):031009. doi:10.1115/1.4006198
    • (2012) J Biomech Eng 134(3) , vol.31009
    • Amiri, S.1    Anglin, C.2    Agbanlog, K.3    Masri, B.A.4    Wilson, D.R.5
  • 13
    • 84899585488 scopus 로고    scopus 로고
    • Amiri S, Masri BA, Anglin C, Wilson DR (2013) A method for assessing joint line shift post knee arthroplasty considering the preoperative joint space. The Knee (in press)
    • Amiri S, Masri BA, Anglin C, Wilson DR (2013) A method for assessing joint line shift post knee arthroplasty considering the preoperative joint space. The Knee (in press). doi:10.1016/J.Knee.2013.03.011
  • 14
    • 0346076621 scopus 로고    scopus 로고
    • Long bone panoramas from fluoroscopic X-ray images
    • PID: 14719684
    • Yaniv Z, Joskowicz L (2004) Long bone panoramas from fluoroscopic X-ray images. IEEE Trans Med Imaging 23(1):26–35. doi:10.1109/Tmi.2003.819931
    • (2004) IEEE Trans Med Imaging , vol.23 , Issue.1 , pp. 26-35
    • Yaniv, Z.1    Joskowicz, L.2
  • 16
    • 77954624420 scopus 로고    scopus 로고
    • Parallax-free intra-operative X-ray image stitching
    • PID: 20561811
    • Wang L, Traub J, Weidert S, Euler E, Navab N (2010) Parallax-free intra-operative X-ray image stitching. Med Image Anal 14(5):674–686. doi:10.1016/J.Media.2010.05.007
    • (2010) Med Image Anal , vol.14 , Issue.5 , pp. 674-686
    • Wang, L.1    Traub, J.2    Weidert, S.3    Euler, E.4    Navab, N.5
  • 17
    • 23044447057 scopus 로고    scopus 로고
    • Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system
    • Jenny JY, Boeri C, Picard F, Leitner F (2004) Reproducibility of intra-operative measurement of the mechanical axes of the lower limb during total knee replacement with a non-image-based navigation system. Comput Aid Surg 9(4):161–165. doi:10.3109/10929080500095517
    • (2004) Comput Aid Surg , vol.9 , Issue.4 , pp. 161-165
    • Jenny, J.Y.1    Boeri, C.2    Picard, F.3    Leitner, F.4
  • 18
    • 84873104064 scopus 로고    scopus 로고
    • First test on three stitching methods with digital detectors used in radiography
    • PID: 23143713
    • Bassi S, Baldini S, Rebuffat C, Sarti R, Ferretti F (2013) First test on three stitching methods with digital detectors used in radiography. Radiol Phys Technol 6(1):187–196. doi:10.1007/S12194-012-0187-9
    • (2013) Radiol Phys Technol , vol.6 , Issue.1 , pp. 187-196
    • Bassi, S.1    Baldini, S.2    Rebuffat, C.3    Sarti, R.4    Ferretti, F.5
  • 21
    • 84855416787 scopus 로고    scopus 로고
    • Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting
    • Bo LE, Leira HO, Tangen GA, Hofstad EF (2012) Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting. Med Phys 39(1):399–406. doi:10.1118/1.3666768
    • (2012) Med Phys , vol.39 , Issue.1 , pp. 399-406
    • Bo, L.E.1    Leira, H.O.2    Tangen, G.A.3    Hofstad, E.F.4
  • 22
    • 33646493693 scopus 로고    scopus 로고
    • Evaluation of a new electromagnetic tracking system using a standardized assessment protocol
    • COI: 1:STN:280:DC%2BD283ltFansg%3D%3D, PID: 16675856
    • Hummel J, Figl M, Birkfellner W, Bax Mr, Shahidi R, Maurer CR Jr, Bergmann H (2006) Evaluation of a new electromagnetic tracking system using a standardized assessment protocol. Phys Med Biol 51(10):N205–N210
    • (2006) Phys Med Biol , vol.51 , Issue.10 , pp. N205-N210
    • Hummel, J.1    Figl, M.2    Birkfellner, W.3    Bax, M.4    Shahidi, R.5    Maurer, C.R.6    Bergmann, H.7
  • 23
    • 77955984187 scopus 로고    scopus 로고
    • C-arm rotation encoding with accelerometers
    • PID: 20383597
    • Grzeda V, Fichtinger G (2010) C-arm rotation encoding with accelerometers. Int J Comput Assist Radiol Surg 5(4):385–391. doi:10.1007/S11548-010-0415-X
    • (2010) Int J Comput Assist Radiol Surg , vol.5 , Issue.4 , pp. 385-391
    • Grzeda, V.1    Fichtinger, G.2
  • 24
    • 84883842446 scopus 로고    scopus 로고
    • Rotational encoding of C-arm fluoroscope with tilt sensing accelerometer
    • Grzeda V, Fichtinger G (2010) Rotational encoding of C-arm fluoroscope with tilt sensing accelerometer. Lect Notes Comput Sci 6363:424–431
    • (2010) Lect Notes Comput Sci , vol.6363 , pp. 424-431
    • Grzeda, V.1    Fichtinger, G.2
  • 25
    • 77957956115 scopus 로고    scopus 로고
    • Accuracy of percutaneous lumbar pedicle screw placement using the oblique or ”owl’s-eye” view and novel guidance technology
    • Idler C, Rolfe KW, Gorek JE (2010) Accuracy of percutaneous lumbar pedicle screw placement using the oblique or ”owl’s-eye” view and novel guidance technology. J Neurosurg Spine 13(4):509–515. doi:10.3171/2010.4.Spine09580
    • (2010) J Neurosurg Spine , vol.13 , Issue.4 , pp. 509-515
    • Idler, C.1    Rolfe, K.W.2    Gorek, J.E.3
  • 26
    • 84870189587 scopus 로고    scopus 로고
    • Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: perioperative results of a prospective, comparative multicenter study
    • Yang BP, Wahl MM, Idler CS (2012) Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: perioperative results of a prospective, comparative multicenter study. Spine 37(24):2055–2060. doi:10.1097/Brs.0b013e31825c05cd
    • (2012) Spine , vol.37 , Issue.24 , pp. 2055-2060
    • Yang, B.P.1    Wahl, M.M.2    Idler, C.S.3
  • 27
    • 84944077375 scopus 로고    scopus 로고
    • Robust automatic C-arm calibration for fluoroscopy-based navigation: a practical approach. In: Dohi T, Kikinis R (eds) Medical image computing and computer-assisted intervention—Miccai 2002, vol 2489, Lecture notes in computer science. Springer, Berlin Heidelberg, pp 60–68
    • Livyatan H, Yaniv Z, Joskowicz L (2002) Robust automatic C-arm calibration for fluoroscopy-based navigation: a practical approach. In: Dohi T, Kikinis R (eds) Medical image computing and computer-assisted intervention—Miccai 2002, vol 2489, Lecture notes in computer science. Springer, Berlin Heidelberg, pp 60–68. doi:10.1007/3-540-45787-9_8
    • (2002) doi:10.1007/3-540-45787-9_8
    • Livyatan, H.1    Yaniv, Z.2    Joskowicz, L.3
  • 28
    • 35148836999 scopus 로고    scopus 로고
    • A cheap and easy method for 3D C-arm reconstruction using elliptic curves. In: Proceedings of the SPIE 6509
    • Burkhardt D, Jain A, Fichtinger G (2007) A cheap and easy method for 3D C-arm reconstruction using elliptic curves. In: Proceedings of the SPIE 6509. doi:Artn 65090b doi:10.1117/12.712395
    • (2007) doi:Artn 65090b doi:10.1117/12.712395
    • Burkhardt, D.1    Jain, A.2    Fichtinger, G.3
  • 31
    • 17844380035 scopus 로고    scopus 로고
    • Accurate technique for complete geometric calibration of cone-beam computed tomography systems
    • Cho Y, Moseley DJ, Jaffray DA (2005) Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Med Phys 32(4):968–983
    • (2005) Med Phys , vol.32 , Issue.4 , pp. 968-983
    • Cho, Y.1    Moseley, D.J.2    Jaffray, D.A.3
  • 32
    • 42949122453 scopus 로고    scopus 로고
    • Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    • Daly MJ, Siewerdsen JH (2008) Geometric calibration of a mobile C-arm for intraoperative cone-beam CT. Med Phys 35(5):2124–2136
    • (2008) Med Phys , vol.35 , Issue.5 , pp. 2124-2136
    • Daly, M.J.1    Siewerdsen, J.H.2
  • 34
    • 80052146811 scopus 로고    scopus 로고
    • Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation
    • Dehghan E, Jain AK, Morris WJ, Salcudean SE (2011) Brachytherapy seed reconstruction with joint-encoded C-arm single-axis rotation and motion compensation. Med Image Anal 15(5):760–771. doi:10.1016/J.Media.2011.05.017
    • (2011) Med Image Anal , vol.15 , Issue.5 , pp. 760-771
    • Dehghan, E.1    Jain, A.K.2    Morris, W.J.3    Salcudean, S.E.4
  • 36
    • 80053589112 scopus 로고    scopus 로고
    • Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis
    • PID: 21992346
    • Dehghan E, Moradi M, Wen X, French D, Lobo J, Fichtinger G (2011) Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis. Med Phys 38(10):5290–5302. doi:10.1118/1.3633897
    • (2011) Med Phys , vol.38 , Issue.10 , pp. 5290-5302
    • Dehghan, E.1    Moradi, M.2    Wen, X.3    French, D.4    Lobo, J.5    Fichtinger, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.