메뉴 건너뛰기




Volumn 32, Issue 4, 2005, Pages 968-983

Accurate technique for complete geometric calibration of cone-beam computed tomography systems

Author keywords

Cone beam computed tomography; Flat panel detector; Geometric calibration; Image guidance; Linear accelerator; Radiation therapy

Indexed keywords

BALL BEARINGS; CALIBRATION; GEOMETRY; IMAGE ENHANCEMENT; IMAGE QUALITY; IMAGE RECONSTRUCTION; LINEAR ACCELERATORS; PARAMETER ESTIMATION; PHANTOMS; RADIOTHERAPY; SENSITIVITY ANALYSIS; UNCERTAINTY ANALYSIS; WIRE; X RAY DETECTORS;

EID: 17844380035     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1869652     Document Type: Article
Times cited : (291)

References (31)
  • 2
    • 0020559807 scopus 로고
    • Computed tomography with a linear accelerator with radiotherapy applications
    • W. Swindell, R. G. Simpson, J. R. Oleson et al., "Computed tomography with a linear accelerator with radiotherapy applications," Med. Phys. 10, 416-420 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 416-420
    • Swindell, W.1    Simpson, R.G.2    Oleson, J.R.3
  • 3
    • 0031735489 scopus 로고    scopus 로고
    • Tomotherapeutic portal imaging for radiation treatment verification
    • B. M. Hesse, L. Spies, and B. A. Groh, "Tomotherapeutic portal imaging for radiation treatment verification," Phys. Med. Biol. 43, 3607-3616 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 3607-3616
    • Hesse, B.M.1    Spies, L.2    Groh, B.A.3
  • 5
    • 0031935731 scopus 로고    scopus 로고
    • A feasibility study for megavoltage cone beam CT using commercial EPlD
    • S. Midgley, R. M. Millar, and J. A. Dudson, "A feasibility study for megavoltage cone beam CT using commercial EPlD," Phys. Med. Biol. 43, 155-169 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 155-169
    • Midgley, S.1    Millar, R.M.2    Dudson, J.A.3
  • 6
    • 0031719485 scopus 로고    scopus 로고
    • Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)
    • H. Guan and Y. Zhu, "Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)," Phys. Med. Biol. 43, 2925-2937 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2925-2937
    • Guan, H.1    Zhu, Y.2
  • 7
    • 0032521265 scopus 로고    scopus 로고
    • Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients: A preliminary experience
    • M. Uematsu, A. Shioda, K. Tahara et al. "Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients: A preliminary experience," Cancer 82, 1062-1070 (1998).
    • (1998) Cancer , vol.82 , pp. 1062-1070
    • Uematsu, M.1    Shioda, A.2    Tahara, K.3
  • 8
    • 0036735854 scopus 로고    scopus 로고
    • Kilovision: Thermal modelling of a kilovoltage x-ray source integrated into a medical linear accelerator
    • Y. Cho and P. Munro, "Kilovision: Thermal modelling of a kilovoltage x-ray source integrated into a medical linear accelerator," Med. Phys. 29, 2101-2108 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2101-2108
    • Cho, Y.1    Munro, P.2
  • 9
    • 0035989949 scopus 로고    scopus 로고
    • A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    • B. A. Groh, J. H. Siewerdesen, D. G. Drake, J. W. Wong, and D. A. Jaffray, "A performance comparison of flat-panel imager-based MV and kV cone-beam CT," Med. Phys. 29, 967-975 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 967-975
    • Groh, B.A.1    Siewerdesen, J.H.2    Drake, D.G.3    Wong, J.W.4    Jaffray, D.A.5
  • 10
    • 33646661282 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • D. A. Jaffray and J. H. Siewerdsen, "Cone-beam computed tomography with a flat-panel imager: Initial performance characterization," Med. Phys. 25, 1493-1501 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1493-1501
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 11
    • 0032866087 scopus 로고    scopus 로고
    • A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
    • D. A. Jaffray, D. Drake, M. Moreau et al., "A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets," Int. J. Radiat. Oncol., Biol., Phys. 45, 773-789 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.45 , pp. 773-789
    • Jaffray, D.A.1    Drake, D.2    Moreau, M.3
  • 12
    • 0027952907 scopus 로고
    • A filtered backprojection algorithm for pinhole SPECT with a displaced center of rotation
    • J. Li, R. J. Jaszczak, K. L. Greer et al., "A filtered backprojection algorithm for pinhole SPECT with a displaced center of rotation," Phys. Med. Biol. 39, 165-176 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 165-176
    • Li, J.1    Jaszczak, R.J.2    Greer, K.L.3
  • 13
    • 0027957857 scopus 로고
    • A cone-beam SPECT reconstruction algorithm with a displaced center of rotation
    • J. Li, R. J. Jaszczak, H. Wang et al., "A cone-beam SPECT reconstruction algorithm with a displaced center of rotation," Med. Phys. 21, 145-152 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 145-152
    • Li, J.1    Jaszczak, R.J.2    Wang, H.3
  • 14
    • 0028697033 scopus 로고
    • Geometric calibration method for multiple-head cone-beam SPECT system
    • Ph. Rizo, P. Grangeat, and R. Guillemaud, "Geometric calibration method for multiple-head cone-beam SPECT system," IEEE Trans. Nucl. Sci. 41, 2748-2757 (1994).
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 2748-2757
    • Rizo, Ph.1    Grangeat, P.2    Guillemaud, R.3
  • 15
    • 0031816946 scopus 로고    scopus 로고
    • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation
    • H. Wang, M. F. Smith, C. D. Stone et al., "Astigmatic single photon emission computed tomography imaging with a displaced center of rotation," Med. Phys. 25, 1493-1501 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1493-1501
    • Wang, H.1    Smith, M.F.2    Stone, C.D.3
  • 18
    • 0033954113 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities
    • R. Fahrig and D. Holdsworth. "Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Image-based correction of gantry motion nonidealities." Med. Phys. 27, 30-38 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 30-38
    • Fahrig, R.1    Holdsworth, D.2
  • 19
    • 0041375307 scopus 로고    scopus 로고
    • Three dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection plat-panel imagers
    • J. H. Siewerdsen and D. A. Jaffray. "Three dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection plat-panel imagers." Proc. SPIE Medical Imaging 2001: Physics of Medical Imaging 5030, 92-102 (2003).
    • (2003) Proc. SPIE Medical Imaging 2001: Physics of Medical Imaging , vol.5030 , pp. 92-102
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 20
    • 0029713961 scopus 로고    scopus 로고
    • Dynamic geometric calibration for 3-D cerebral angiography
    • A. Navab, A. Bani-Hashemi, M. Mitshke et al., "Dynamic geometric calibration for 3-D cerebral angiography," Proc. SPIE Medical Imaging 2708, 361-370 (1996).
    • (1996) Proc. SPIE Medical Imaging , vol.2708 , pp. 361-370
    • Navab, A.1    Bani-Hashemi, A.2    Mitshke, M.3
  • 21
    • 84947795740 scopus 로고    scopus 로고
    • 3D reconstruction from projection matrices in a C-arm based 3D-angiography system
    • A. Navab, A. Bani-Hashemi, MS. Nadar et al., "3D reconstruction from projection matrices in a C-arm based 3D-angiography system," MICCAI 1496, 119-129 (1998).
    • (1998) MICCAI , vol.1496 , pp. 119-129
    • Navab, A.1    Bani-Hashemi, A.2    Nadar, M.S.3
  • 22
    • 0027637986 scopus 로고
    • Geometric calibration of x-ray imaging chains for three-dimensional reconstruction
    • A. Rougee, C. Picard, C. Ponchut, and Y. Trousset, "Geometric calibration of x-ray imaging chains for three-dimensional reconstruction," Comput. Med. Imaging Graph. 17, 295-300 (1993).
    • (1993) Comput. Med. Imaging Graph. , vol.17 , pp. 295-300
    • Rougee, A.1    Picard, C.2    Ponchut, C.3    Trousset, Y.4
  • 23
    • 0033781494 scopus 로고    scopus 로고
    • Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
    • F. Noo, R. Clackdoyle, C. Mennessier et al., "Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography," Phys. Med. Biol. 45, 3489-3508 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 3489-3508
    • Noo, F.1    Clackdoyle, R.2    Mennessier, C.3
  • 24
    • 0001091515 scopus 로고    scopus 로고
    • Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements
    • A. V. Bronnikov, "Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements," Opt. Eng. 38, 381-386 (1999).
    • (1999) Opt. Eng. , vol.38 , pp. 381-386
    • Bronnikov, A.V.1
  • 25
    • 0343252974 scopus 로고    scopus 로고
    • A novel technique to characterize the complete motion of a linear accelerator
    • M. Moreau, D. Drake, and D, Jaffray, "A novel technique to characterize the complete motion of a linear accelerator," Med. Phys. 25, A191 (1998).
    • (1998) Med. Phys. , vol.25
    • Moreau, M.1    Drake, D.2    Jaffray, D.3
  • 26
    • 0002383355 scopus 로고
    • An efficient camera calibration techniques for 3D machine vision
    • R. Y. Tsai, "An efficient camera calibration techniques for 3D machine vision," IEEE PAMI 8, 364-374 (1986).
    • (1986) IEEE PAMI , vol.8 , pp. 364-374
    • Tsai, R.Y.1
  • 27
    • 0024070570 scopus 로고
    • Techniques for calibration of the scale factor and image center for high accuracy 3D machine
    • R. K. Lenz and R. Y. Tsai, "Techniques for calibration of the scale factor and image center for high accuracy 3D machine." IEEE PAMI 10(5), 713-720 (1988).
    • (1988) IEEE PAMI , vol.10 , Issue.5 , pp. 713-720
    • Lenz, R.K.1    Tsai, R.Y.2
  • 31
    • 33646659388 scopus 로고
    • Chap. XV, D'etermination d'une Conique (Gauthier-Villars, Paris)
    • B. Niewenglowski, Ours de G'eom'etrie Analytique. Tome II. Chap. XV, D'etermination d'une Conique (Gauthier-Villars, Paris, 1911), pp. 260-289.
    • (1911) Ours de G'eom'etrie Analytique , vol.2 , pp. 260-289
    • Niewenglowski, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.