메뉴 건너뛰기




Volumn 35, Issue 6, 2004, Pages 567-574

Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants: A prospective, controlled clinical study

Author keywords

Distal locking; Exposure to radiation; Fluoroscopy based surgical navigation; Intramedullary nailing; Virtual fluoroscopy

Indexed keywords

ACCURACY; ARTICLE; BONE SCREW; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DRILL; FLUOROSCOPY; HUMAN; IMPLANT; INTERMETHOD COMPARISON; INTRAMEDULLARY NAILING; LEG FRACTURE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RELIABILITY; SURGICAL PATIENT; SURGICAL TECHNIQUE; TIME;

EID: 2342574698     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0020-1383(03)00312-7     Document Type: Article
Times cited : (66)

References (12)
  • 1
    • 0021343937 scopus 로고
    • Radiation exposure to an orthopedic surgeon
    • Barry T.P. Radiation exposure to an orthopedic surgeon. Clin. Orthop. 182:1984;160-164
    • (1984) Clin. Orthop. , vol.182 , pp. 160-164
    • Barry, T.P.1
  • 2
  • 3
    • 0024405999 scopus 로고
    • Locking nailing: An aid to distal targeting
    • Hudson I. Locking nailing: an aid to distal targeting. Injury. 20:1989;129-130
    • (1989) Injury , vol.20 , pp. 129-130
    • Hudson, I.1
  • 5
    • 0023278854 scopus 로고
    • Radiation exposure to the surgeon during closed interlocking intramedullary nailing
    • Levin P.E., Schoen R.W., Browner B.D. Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J. Bone Joint Surg. (Am.). 69:1987;761-766
    • (1987) J. Bone Joint Surg. (Am.) , vol.69 , pp. 761-766
    • Levin, P.E.1    Schoen, R.W.2    Browner, B.D.3
  • 6
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?"
    • Mehlman C.T., DiPasquale T.G. Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?" J. Orthop. Trauma. 11:1997;392-398
    • (1997) J. Orthop. Trauma , vol.11 , pp. 392-398
    • Mehlman, C.T.1    Dipasquale, T.G.2
  • 7
    • 0020684975 scopus 로고
    • Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures
    • Miller M.E., Davis M.L., MacClean C.R., Davis J.G., Smith B.L., Humphries J.R. Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures. J. Bone Joint Surg. (Am.). 65:1983;1-4
    • (1983) J. Bone Joint Surg. (Am.) , vol.65 , pp. 1-4
    • Miller, M.E.1    Davis, M.L.2    MacClean, C.R.3    Davis, J.G.4    Smith, B.L.5    Humphries, J.R.6
  • 9
    • 0035257635 scopus 로고    scopus 로고
    • Novel computer-assisted fluoroscopy system for intraoperative guidance: Feasibility study for distal locking of femoral nails
    • Slomczykowski M.A., Hofstetter R., Sati M., Krettek C., Nolte L.P. Novel computer-assisted fluoroscopy system for intraoperative guidance: feasibility study for distal locking of femoral nails. J. Orthop. Trauma. 15:2001;122-131
    • (2001) J. Orthop. Trauma , vol.15 , pp. 122-131
    • Slomczykowski, M.A.1    Hofstetter, R.2    Sati, M.3    Krettek, C.4    Nolte, L.P.5
  • 10
    • 0023761647 scopus 로고
    • Radiation dosage during AO locking femoral nailing
    • Sugarman I.D., Adam I., Bunker T.D. Radiation dosage during AO locking femoral nailing. Injury. 19:1988;336-368
    • (1988) Injury , vol.19 , pp. 336-368
    • Sugarman, I.D.1    Adam, I.2    Bunker, T.D.3
  • 11
    • 0034463546 scopus 로고    scopus 로고
    • Surgical navigation based on fluoroscopy-clinical application for computer-assisted distal locking of intramedullary implants
    • Suhm N., Jacob A.L., Nolte L.P., Regazzoni P., Messmer P. Surgical navigation based on fluoroscopy-clinical application for computer-assisted distal locking of intramedullary implants. Comput. Aided Surg. 5:2000;391-400
    • (2000) Comput. Aided Surg. , vol.5 , pp. 391-400
    • Suhm, N.1    Jacob, A.L.2    Nolte, L.P.3    Regazzoni, P.4    Messmer, P.5
  • 12
    • 17144455506 scopus 로고    scopus 로고
    • Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery
    • Tremains M.R., Georgiadis G.M., Dennis M.J. Radiation exposure with use of the inverted-c-arm technique in upper-extremity surgery. J. Bone Joint Surg. (Am.). 83:2001;674-678
    • (2001) J. Bone Joint Surg. (Am.) , vol.83 , pp. 674-678
    • Tremains, M.R.1    Georgiadis, G.M.2    Dennis, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.