메뉴 건너뛰기




Volumn 64, Issue 13, 2014, Pages 1323-1334

Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: A PARTNER trial cohort-a analysis

(20)  Pibarot, Philippe a   Weissman, Neil J b   Stewart, William J c   Hahn, Rebecca T d,e   Lindman, Brian R f   McAndrew, Thomas e   Kodali, Susheel K d,e   Mack, Michael J g   Thourani, Vinod H h   Miller, D Craig i   Svensson, Lars G c   Herrmann, Howard C j   Smith, Craig R d,e   Rodés Cabau, Josep a   Webb, John k   Lim, Scott l   Xu, Ke e   Hueter, Irene d   Douglas, Pamela S m   Leon, Martin B d,e  


Author keywords

aortic regurgitation; Doppler echocardiography; left ventricular mass regression; mortality

Indexed keywords

AGED; AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTICLE; COHORT ANALYSIS; CONTROLLED STUDY; DISEASE SEVERITY; ECHOCARDIOGRAPHY; FEMALE; HEART LEFT VENTRICLE HYPERTROPHY; HEART LEFT VENTRICLE MASS; HIGH RISK PATIENT; HUMAN; INCIDENCE; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; POSTOPERATIVE PERIOD; PREDICTION; PROSTHESIS PATIENT MISMATCH; RANDOMIZED CONTROLLED TRIAL; SURGICAL MORTALITY; SURGICAL RISK; SURGICAL TECHNIQUE; SURVIVAL RATE; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME; VERY ELDERLY; AORTA VALVE; BIOPROSTHESIS; CONTROLLED CLINICAL TRIAL; DOPPLER ECHOCARDIOGRAPHY; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; LEFT VENTRICULAR MASS REGRESSION; MIDDLE AGED; MORTALITY; MULTICENTER STUDY; PATHOPHYSIOLOGY; PROSTHESIS FAILURE; REGRESSION ANALYSIS; TIME;

EID: 84908290638     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2014.06.1195     Document Type: Article
Times cited : (326)

References (21)
  • 1
    • 79955953134 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch: An update
    • J.G. Dumesnil, and P. Pibarot Prosthesis-patient mismatch: an update Curr Cardiol Rep 13 2011 250 257
    • (2011) Curr Cardiol Rep , vol.13 , pp. 250-257
    • Dumesnil, J.G.1    Pibarot, P.2
  • 2
    • 84863579774 scopus 로고    scopus 로고
    • The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: A systematic review and meta-analysis of 34 observational studies comprising 27,186 patients with 133,141 patient-years
    • S. Head, M. Mokhles, and R. Osnabrugge The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27,186 patients with 133,141 patient-years Eur Heart J 33 2012 1518 1529
    • (2012) Eur Heart J , vol.33 , pp. 1518-1529
    • Head, S.1    Mokhles, M.2    Osnabrugge, R.3
  • 3
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • C.R. Smith, M.B. Leon, and M.J. Mack Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 4
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • S.K. Kodali, M.R. Williams, and C.R. Smith Two-year outcomes after transcatheter or surgical aortic-valve replacement N Engl J Med 366 2012 1686 1695
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 5
    • 65149088915 scopus 로고    scopus 로고
    • Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis
    • M.A. Clavel, J.G. Webb, and P. Pibarot Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis J Am Coll Cardiol 53 2009 1883 1891
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1883-1891
    • Clavel, M.A.1    Webb, J.G.2    Pibarot, P.3
  • 6
    • 77950526783 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis
    • H. Jilaihawi, D. Chin, and T. Spyt Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis Eur Heart J 31 2010 857 864
    • (2010) Eur Heart J , vol.31 , pp. 857-864
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3
  • 7
    • 80054993345 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation
    • S.H. Ewe, M. Muratori, and V. Delgado Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation J Am Coll Cardiol 58 2011 1910 1918
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1910-1918
    • Ewe, S.H.1    Muratori, M.2    Delgado, V.3
  • 8
    • 84872356691 scopus 로고    scopus 로고
    • Patient-prosthesis mismatch after transapical aortic valve implantation: Incidence and impact on survival
    • M. Kukucka, M. Pasic, and S. Dreysse Patient-prosthesis mismatch after transapical aortic valve implantation: incidence and impact on survival J Thorac Cardiovasc Surg 145 2013 391 397
    • (2013) J Thorac Cardiovasc Surg , vol.145 , pp. 391-397
    • Kukucka, M.1    Pasic, M.2    Dreysse, S.3
  • 9
    • 77955691974 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis
    • A. Tzikas, N. Piazza, and M.L. Geleijnse Prosthesis-patient mismatch after transcatheter aortic valve implantation with the medtronic CoreValve system in patients with aortic stenosis Am J Cardiol 106 2010 255 260
    • (2010) Am J Cardiol , vol.106 , pp. 255-260
    • Tzikas, A.1    Piazza, N.2    Geleijnse, M.L.3
  • 10
    • 84881314470 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN prosthesis
    • A. Van Linden, J. Kempfert, and J. Blumenstein Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN prosthesis Thorac Cardiovasc Surg 61 2013 414 420
    • (2013) Thorac Cardiovasc Surg , vol.61 , pp. 414-420
    • Van Linden, A.1    Kempfert, J.2    Blumenstein, J.3
  • 11
    • 33751547284 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement in patients with critical aortic stenosis: Rationale, device descriptions, early clinical experiences, and perspectives
    • M.B. Leon, S. Kodali, and M. Williams Transcatheter aortic valve replacement in patients with critical aortic stenosis: rationale, device descriptions, early clinical experiences, and perspectives Semin Thorac Cardiovasc Surg 18 2006 165 174
    • (2006) Semin Thorac Cardiovasc Surg , vol.18 , pp. 165-174
    • Leon, M.B.1    Kodali, S.2    Williams, M.3
  • 12
    • 84875493388 scopus 로고    scopus 로고
    • Implementation of echocardiography core laboratory best practices: A case study of the PARTNER i trial
    • P.S. Douglas, R.A. Waugh, and G. Bloomfield Implementation of echocardiography core laboratory best practices: a case study of the PARTNER I trial J Am Soc Echocardiogr 26 2013 348 358.e3
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 348-358e3
    • Douglas, P.S.1    Waugh, R.A.2    Bloomfield, G.3
  • 13
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology
    • R.M. Lang, M. Bierig, and R.B. Devereux Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology J Am Soc Echocardiogr 18 2005 1440 1463
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3
  • 14
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves
    • W.A. Zoghbi, J.B. Chambers, and J.G. Dumesnil Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3
  • 15
    • 84879222556 scopus 로고    scopus 로고
    • Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: A longitudinal study of echo parameters in cohort A of the PARTNER Trial
    • R.T. Hahn, P. Pibarot, and W.J. Stewart Comparison of transcatheter and surgical aortic valve replacement in severe aortic stenosis: a longitudinal study of echo parameters in cohort A of the PARTNER Trial J Am Coll Cardiol 61 2013 2514 2521
    • (2013) J Am Coll Cardiol , vol.61 , pp. 2514-2521
    • Hahn, R.T.1    Pibarot, P.2    Stewart, W.J.3
  • 16
    • 80052088476 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation in patients with severe aortic stenosis and small aortic annulus
    • D. Kalavrouziotis, J. Rodés-Cabau, and R. Bagur Transcatheter aortic valve implantation in patients with severe aortic stenosis and small aortic annulus J Am Coll Cardiol 58 2011 1016 1024
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1016-1024
    • Kalavrouziotis, D.1    Rodés-Cabau, J.2    Bagur, R.3
  • 17
    • 84861534743 scopus 로고    scopus 로고
    • Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve
    • L. Nombela-Franco, J. Rodés-Cabau, and R. DeLarochellière Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve J Am Coll Cardiol Intv 5 2012 499 512
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 499-512
    • Nombela-Franco, L.1    Rodés-Cabau, J.2    Delarochellière, R.3
  • 18
    • 84904970354 scopus 로고    scopus 로고
    • Outcomes with post-dilation following transcatheter aortic valve replacement
    • R.T. Hahn, P. Pibarot, and J. Webb Outcomes with post-dilation following transcatheter aortic valve replacement J Am Coll Cardiol Intv 7 2014 781 789
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 781-789
    • Hahn, R.T.1    Pibarot, P.2    Webb, J.3
  • 19
    • 33846929938 scopus 로고    scopus 로고
    • Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement
    • F. Bakhtiary, M. Schiemann, and O. Dzemali Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement J Am Coll Cardiol 49 2007 790 796
    • (2007) J Am Coll Cardiol , vol.49 , pp. 790-796
    • Bakhtiary, F.1    Schiemann, M.2    Dzemali, O.3
  • 20
    • 57949105389 scopus 로고    scopus 로고
    • Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: Influence of age, obesity, and left ventricular dysfunction
    • D. Mohty, J.G. Dumesnil, and N. Echahidi Impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: influence of age, obesity, and left ventricular dysfunction J Am Coll Cardiol 53 2009 39 47
    • (2009) J Am Coll Cardiol , vol.53 , pp. 39-47
    • Mohty, D.1    Dumesnil, J.G.2    Echahidi, N.3
  • 21
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • M. Gilard, H. Eltchaninoff, and B. Iung Registry of transcatheter aortic-valve implantation in high-risk patients N Engl J Med 366 2012 1705 1715
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.