메뉴 건너뛰기




Volumn 5, Issue 5, 2012, Pages 499-512

Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve

Author keywords

balloon post dilation; stroke; transapical; transcatheter aortic valve implantation; transcatheter aortic valve replacement; transfemoral

Indexed keywords

AGED; AORTA VALVE REGURGITATION; ARTICLE; BALLOON DILATATION; BLOOD VESSEL CALCIFICATION; CONTROLLED STUDY; FEMALE; FOLLOW UP; HUMAN; INCIDENCE; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 84861534743     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2012.02.010     Document Type: Article
Times cited : (189)

References (21)
  • 1
    • 83655184726 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Current and future approaches
    • J. Rodés-Cabau Transcatheter aortic valve implantation: current and future approaches Nat Rev Cardiol 9 2011 15 29
    • (2011) Nat Rev Cardiol , vol.9 , pp. 15-29
    • Rodés-Cabau, J.1
  • 2
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome Results from the German Transcatheter Aortic Valve Interventions Registry
    • German Transcatheter Aortic Valve Interventions Registry Investigators
    • M. Abdel-Wahab, R. Zahn, M. Horack German Transcatheter Aortic Valve Interventions Registry Investigators Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome Results from the German Transcatheter Aortic Valve Interventions Registry Heart 97 2011 899 906
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 3
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • C. Tamburino, D. Capodanno, A. Ramondo Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 4
    • 80255137247 scopus 로고    scopus 로고
    • Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis the UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry
    • N.E. Moat, P. Ludman, M.A. de Belder Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis The UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry J Am Coll Cardiol 58 2011 2130 2138
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2130-2138
    • Moat, N.E.1    Ludman, P.2    De Belder, M.A.3
  • 5
    • 76649123667 scopus 로고    scopus 로고
    • Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis
    • D. John, L. Buellesfeld, S. Yuecel Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis J Am Coll Cardiol Intv 3 2010 233 243
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 233-243
    • John, D.1    Buellesfeld, L.2    Yuecel, S.3
  • 6
    • 80255140488 scopus 로고    scopus 로고
    • Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation
    • S.H. Ewe, A.C. Ng, J.D. Schuijf Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation Am J Cardiol 108 2011 1470 1477
    • (2011) Am J Cardiol , vol.108 , pp. 1470-1477
    • Ewe, S.H.1    Ng, A.C.2    Schuijf, J.D.3
  • 7
    • 84856460597 scopus 로고    scopus 로고
    • Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation
    • K. Takagi, A. Latib, R. Al-Lamee Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation Catheter Cardiovasc Interv 78 2011 432 443
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 432-443
    • Takagi, K.1    Latib, A.2    Al-Lamee, R.3
  • 8
    • 80055107711 scopus 로고    scopus 로고
    • Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis
    • C. Schultz, A. Rossi, N. van Mieghem Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis EuroIntervention 7 2011 564 572
    • (2011) EuroIntervention , vol.7 , pp. 564-572
    • Schultz, C.1    Rossi, A.2    Van Mieghem, N.3
  • 9
    • 80052778092 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: Analysis of risk factors and learning experience in 299 patients
    • J. Kempfert, A. Rastan, D. Holzhey Transapical aortic valve implantation: analysis of risk factors and learning experience in 299 patients Circulation 124 2011 S124 S129
    • (2011) Circulation , vol.124
    • Kempfert, J.1    Rastan, A.2    Holzhey, D.3
  • 10
    • 77951123355 scopus 로고    scopus 로고
    • European Association of Echocardiography recommendations for the assessment of valvular regurgitation Part 1: Aortic and pulmonary regurgitation (native valve disease)
    • P. Lancelloti, C. Tribouilloy, A. Hagendorff European Association of Echocardiography recommendations for the assessment of valvular regurgitation Part 1: aortic and pulmonary regurgitation (native valve disease) Eur J Echocardiogr 11 2010 223 244
    • (2010) Eur J Echocardiogr , vol.11 , pp. 223-244
    • Lancelloti, P.1    Tribouilloy, C.2    Hagendorff, A.3
  • 11
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves
    • W.A. Zoghbi, J.B. Chambers, J.G. Dumesnil Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3
  • 12
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, E. Nikolsky Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium J Am Coll Cardiol 57 2011 253 269
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 13
    • 80054105495 scopus 로고    scopus 로고
    • Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography
    • M.A. Clavel, J. Rodés-Cabau, E. Dumont Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography J Am Coll Cardiol Img 4 2011 1053 1062
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 1053-1062
    • Clavel, M.A.1    Rodés-Cabau, J.2    Dumont, E.3
  • 15
    • 79951635839 scopus 로고    scopus 로고
    • Usefulness of TEE as the primary imaging technique to guide transcatheter transapical aortic valve implantation
    • R. Bagur, J. Rodés-Cabau, D. Doyle Usefulness of TEE as the primary imaging technique to guide transcatheter transapical aortic valve implantation J Am Coll Cardiol Img 4 2011 115 124
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 115-124
    • Bagur, R.1    Rodés-Cabau, J.2    Doyle, D.3
  • 16
    • 79961097900 scopus 로고    scopus 로고
    • Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study (abstr)
    • P. Kahlert, P. Doettger, K. Mori Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study (abstr) Circulation 122 2010 A18122
    • (2010) Circulation , vol.122 , pp. 18122
    • Kahlert, P.1    Doettger, P.2    Mori, K.3
  • 17
    • 79961042044 scopus 로고    scopus 로고
    • Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement
    • W.Y. Szeto, J.G. Augoustides, N.D. Desai Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement J Card Surg 26 2011 348 354
    • (2011) J Card Surg , vol.26 , pp. 348-354
    • Szeto, W.Y.1    Augoustides, J.G.2    Desai, N.D.3
  • 18
    • 84863338349 scopus 로고    scopus 로고
    • Occurrence, hazard, risk factors, and consequences of neurologic events in the PARTNER trial
    • D.C. Miller, E.H. Blackstone, M.J. Mack Occurrence, hazard, risk factors, and consequences of neurologic events in the PARTNER trial J Thorac Cardiovasc Surg 143 2012 832 843
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 832-843
    • Miller, D.C.1    Blackstone, E.H.2    MacK, M.J.3
  • 19
    • 3242675955 scopus 로고    scopus 로고
    • Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography
    • D. Messika-Zeitoun, M.C. Aubry, D. Detaint Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography Circulation 110 2004 356 362
    • (2004) Circulation , vol.110 , pp. 356-362
    • Messika-Zeitoun, D.1    Aubry, M.C.2    Detaint, D.3
  • 20
    • 79953893341 scopus 로고    scopus 로고
    • Measurement of aortic valve calcification using multislice computed tomography: Correlation with haemodynamic severity of aortic stenosis and clinical implication for patients with low ejection fraction
    • C. Cueff, J.M. Serfaty, C. Cimadevilla Measurement of aortic valve calcification using multislice computed tomography: correlation with haemodynamic severity of aortic stenosis and clinical implication for patients with low ejection fraction Heart 97 2011 721 726
    • (2011) Heart , vol.97 , pp. 721-726
    • Cueff, C.1    Serfaty, J.M.2    Cimadevilla, C.3
  • 21
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • PARTNER Trial Investigators
    • C.R. Smith, M.B. Leon, M.J. Mack PARTNER Trial Investigators Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    MacK, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.