-
1
-
-
84874751053
-
A trial of imaging selection and endovascular treatment for ischemic stroke
-
Kidwell CS, Jahan R, Gornbein J, Alger JR, Nenov V, Ajani Z, Feng L, Meyer BC, Olson S, Schwamm LH, Yoo AJ, Marshall RS, Meyers PM, Yavagal DR, Wintermark M, Guzy J, Starkman S, Saver JL. A trial of imaging selection and endovascular treatment for ischemic stroke. N. Engl. J. Med. 2013; 368: 914-923.
-
(2013)
N. Engl. J. Med.
, vol.368
, pp. 914-923
-
-
Kidwell, C.S.1
Jahan, R.2
Gornbein, J.3
Alger, J.R.4
Nenov, V.5
Ajani, Z.6
Feng, L.7
Meyer, B.C.8
Olson, S.9
Schwamm, L.H.10
Yoo, A.J.11
Marshall, R.S.12
Meyers, P.M.13
Yavagal, D.R.14
Wintermark, M.15
Guzy, J.16
Starkman, S.17
Saver, J.L.18
-
2
-
-
0019822988
-
Thresholds in cerebral ischemia - the ischemic penumbra
-
Astrup J, Siejo BK, Symon L. Thresholds in cerebral ischemia - the ischemic penumbra. Stroke 1981; 12: 723-725.
-
(1981)
Stroke
, vol.12
, pp. 723-725
-
-
Astrup, J.1
Siejo, B.K.2
Symon, L.3
-
3
-
-
0027982679
-
Viability thresholds and the penumbra of focal ischemia
-
Hossmann K. Viability thresholds and the penumbra of focal ischemia. Ann. Neurol. 1994; 36: 557-565.
-
(1994)
Ann. Neurol.
, vol.36
, pp. 557-565
-
-
Hossmann, K.1
-
4
-
-
84892838268
-
Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI
-
doi: 10.1002/nbm.3048.
-
Tietze A, Blicher J, Mikkelsen IK, Østergaard L, Strother MK, Smith SA, Donahue MJ. Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI. NMR Biomed. 2013; doi: 10.1002/nbm.3048.
-
(2013)
NMR Biomed.
-
-
Tietze, A.1
Blicher, J.2
Mikkelsen, I.K.3
Østergaard, L.4
Strother, M.K.5
Smith, S.A.6
Donahue, M.J.7
-
5
-
-
0042466426
-
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
-
Zhou J, Payen J, Wilson DA, Traystman RJ, van Zijl PCM. Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nat. Med. 2003; 9: 1085-1090.
-
(2003)
Nat. Med.
, vol.9
, pp. 1085-1090
-
-
Zhou, J.1
Payen, J.2
Wilson, D.A.3
Traystman, R.J.4
van Zijl, P.C.M.5
-
6
-
-
84855998868
-
Imaging acute ischemic tissue acidosis with pH-sensitive endogenous amide proton transfer (APT) MRI - correction of tissue relaxation and concomitant RF irradiation effects toward mapping quantitative cerebral tissue pH
-
Sun PZ, Wang E, Cheung JS. Imaging acute ischemic tissue acidosis with pH-sensitive endogenous amide proton transfer (APT) MRI - correction of tissue relaxation and concomitant RF irradiation effects toward mapping quantitative cerebral tissue pH. Neuroimage 2012; 60: 1-6.
-
(2012)
Neuroimage
, vol.60
, pp. 1-6
-
-
Sun, P.Z.1
Wang, E.2
Cheung, J.S.3
-
7
-
-
34249276387
-
Detection of the ischemic penumbra using pH-weighted MRI
-
Sun PZ, Zhou J, Sun W, Huang J, van Zijl PCM. Detection of the ischemic penumbra using pH-weighted MRI. J. Cereb. Blood Flow Metab. 2007; 27: 1129-1136.
-
(2007)
J. Cereb. Blood Flow Metab.
, vol.27
, pp. 1129-1136
-
-
Sun, P.Z.1
Zhou, J.2
Sun, W.3
Huang, J.4
van Zijl, P.C.M.5
-
8
-
-
79961014873
-
Association between pH-weighted endogenous amide proton chemical exchange saturation transfer MRI and tissue lactic acidosis during acute ischemic stroke
-
Sun PZ, Cheung JS, Wang E, Lo EH. Association between pH-weighted endogenous amide proton chemical exchange saturation transfer MRI and tissue lactic acidosis during acute ischemic stroke. J. Cereb. Blood Flow Metab. 2011; 31: 1743-1750.
-
(2011)
J. Cereb. Blood Flow Metab.
, vol.31
, pp. 1743-1750
-
-
Sun, P.Z.1
Cheung, J.S.2
Wang, E.3
Lo, E.H.4
-
9
-
-
34248337816
-
Proton transfer ratio, lactate, and intracellular pH in acute cerebral ischemia
-
Jokivarsi KT, Gröhn HI, Gröhn OH, Kauppinen RA. Proton transfer ratio, lactate, and intracellular pH in acute cerebral ischemia. Magn. Reson. Med. 2007; 57: 647-653.
-
(2007)
Magn. Reson. Med.
, vol.57
, pp. 647-653
-
-
Jokivarsi, K.T.1
Gröhn, H.I.2
Gröhn, O.H.3
Kauppinen, R.A.4
-
10
-
-
80052979511
-
Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3T
-
Zhao X, Wen Z, Huang F, Lu S, Wang X, Hu S, Zu D, Zhou J. Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3T. Magn. Reson. Med. 2011; 66: 1033-1041.
-
(2011)
Magn. Reson. Med.
, vol.66
, pp. 1033-1041
-
-
Zhao, X.1
Wen, Z.2
Huang, F.3
Lu, S.4
Wang, X.5
Hu, S.6
Zu, D.7
Zhou, J.8
-
11
-
-
84879603466
-
Chemical exchange saturation transfer MR imaging: potential clinical applications
-
Polders DL, Hoogduin JM. Chemical exchange saturation transfer MR imaging: potential clinical applications. PET Clin. 2013; 8: 245-257.
-
(2013)
PET Clin.
, vol.8
, pp. 245-257
-
-
Polders, D.L.1
Hoogduin, J.M.2
-
12
-
-
79952782590
-
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
-
van Zijl PCM, Yadav NN. Chemical exchange saturation transfer (CEST): what is in a name and what isn't? Magn. Reson. Med. 2011; 65: 927-948.
-
(2011)
Magn. Reson. Med.
, vol.65
, pp. 927-948
-
-
van Zijl, P.C.M.1
Yadav, N.N.2
-
13
-
-
33744523144
-
Paramagnetic lanthanide complexes as PARACEST agents for medical imaging
-
Woods M, Woessner DE, Sherry AD. Paramagnetic lanthanide complexes as PARACEST agents for medical imaging. Chem. Soc. Rev. 2006; 35: 500-511.
-
(2006)
Chem. Soc. Rev.
, vol.35
, pp. 500-511
-
-
Woods, M.1
Woessner, D.E.2
Sherry, A.D.3
-
14
-
-
33747238228
-
Chemical exchange saturation transfer imaging and spectroscopy
-
Zhou J, van Zijl PCM. Chemical exchange saturation transfer imaging and spectroscopy. Prog. Nucl. Magn. Reson. Spectrosc. 2006; 48: 109-136.
-
(2006)
Prog. Nucl. Magn. Reson. Spectrosc.
, vol.48
, pp. 109-136
-
-
Zhou, J.1
van Zijl, P.C.M.2
-
15
-
-
33645772151
-
Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): pH calibration for poly-L-lysine and a starburst dendrimer
-
McMahon MT, Gilad AA, Zhou J, Sun PZ, Bulte JWM, van Zijl PCM. Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): pH calibration for poly-L-lysine and a starburst dendrimer. Magn. Reson. Med. 2006; 55: 836-847.
-
(2006)
Magn. Reson. Med.
, vol.55
, pp. 836-847
-
-
McMahon, M.T.1
Gilad, A.A.2
Zhou, J.3
Sun, P.Z.4
Bulte, J.W.M.5
van Zijl, P.C.M.6
-
16
-
-
84857656352
-
Defining an acidosis-based ischemic penumbra from pH-weighted MRI
-
Zhou J, van Zijl PCM. Defining an acidosis-based ischemic penumbra from pH-weighted MRI. Transl. Stroke Res. 2012; 3: 76-83.
-
(2012)
Transl. Stroke Res.
, vol.3
, pp. 76-83
-
-
Zhou, J.1
van Zijl, P.C.M.2
-
17
-
-
84876700384
-
Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7T
-
Jones CK, Huang A, Xu J, Edden RAE, Schär M, Hua J, Oskolkov N, Zacà D, Zhou J, McMahon MT, Pillai JJ, van Zijl PCM. Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7T. Neuroimage 2013; 77: 114-124.
-
(2013)
Neuroimage
, vol.77
, pp. 114-124
-
-
Jones, C.K.1
Huang, A.2
Xu, J.3
Edden, R.A.E.4
Schär, M.5
Hua, J.6
Oskolkov, N.7
Zacà, D.8
Zhou, J.9
McMahon, M.T.10
Pillai, J.J.11
van Zijl, P.C.M.12
-
18
-
-
84881139836
-
Quantitative Bayesian model-based analysis of amide proton transfer MRI
-
Chappell MA, Donahue MJ, Tee YK, Khrapitchev AA, Sibson NR, Jezzard P, Payne SJ. Quantitative Bayesian model-based analysis of amide proton transfer MRI. Magn. Reson. Med. 2012; 70: 556-567.
-
(2012)
Magn. Reson. Med.
, vol.70
, pp. 556-567
-
-
Chappell, M.A.1
Donahue, M.J.2
Tee, Y.K.3
Khrapitchev, A.A.4
Sibson, N.R.5
Jezzard, P.6
Payne, S.J.7
-
19
-
-
71649104936
-
Methods for an improved detection of the MRI-CEST effect
-
Terreno E, Stancanello J, Longo D, Delli Castelli D, Milone L, Sanders HMHF, Kok MB, Uggeri F, Aime S. Methods for an improved detection of the MRI-CEST effect. Contrast Media Mol. Imaging 2009; 4: 237-247.
-
(2009)
Contrast Media Mol. Imaging
, vol.4
, pp. 237-247
-
-
Terreno, E.1
Stancanello, J.2
Longo, D.3
Delli Castelli, D.4
Milone, L.5
Sanders, H.M.H.F.6
Kok, M.B.7
Uggeri, F.8
Aime, S.9
-
20
-
-
33846784003
-
Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia
-
Sun PZ, Zhou J, Huang J, van Zijl P. Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia. Magn. Reson. Med. 2007; 57: 405-410.
-
(2007)
Magn. Reson. Med.
, vol.57
, pp. 405-410
-
-
Sun, P.Z.1
Zhou, J.2
Huang, J.3
van Zijl, P.4
-
21
-
-
84861228996
-
In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7T
-
Jones CK, Polders D, Hua J, Zhu H, Hoogduin HJ, Zhou J, Luijten P, van Zijl PC. In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7T. Magn. Reson. Med. 2012; 67: 1579-1589.
-
(2012)
Magn. Reson. Med.
, vol.67
, pp. 1579-1589
-
-
Jones, C.K.1
Polders, D.2
Hua, J.3
Zhu, H.4
Hoogduin, H.J.5
Zhou, J.6
Luijten, P.7
van Zijl, P.C.8
-
22
-
-
84859109553
-
Understanding quantitative pulsed CEST in the presence of MT
-
Desmond KL, Stanisz GJ. Understanding quantitative pulsed CEST in the presence of MT. Magn. Reson. Med. 2012; 67: 979-990.
-
(2012)
Magn. Reson. Med.
, vol.67
, pp. 979-990
-
-
Desmond, K.L.1
Stanisz, G.J.2
-
23
-
-
84865142753
-
Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST)
-
Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA. Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST). J. Magn. Reson. 2012; 222: 88-95.
-
(2012)
J. Magn. Reson.
, vol.222
, pp. 88-95
-
-
Tee, Y.K.1
Khrapitchev, A.A.2
Sibson, N.R.3
Payne, S.J.4
Chappell, M.A.5
-
24
-
-
84886790393
-
Optimal sampling schedule for chemical exchange saturation transfer
-
Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA. Optimal sampling schedule for chemical exchange saturation transfer. Magn. Reson. Med. 2013; 70: 1251-1262.
-
(2013)
Magn. Reson. Med.
, vol.70
, pp. 1251-1262
-
-
Tee, Y.K.1
Khrapitchev, A.A.2
Sibson, N.R.3
Payne, S.J.4
Chappell, M.A.5
-
25
-
-
16444362041
-
Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI
-
Woessner DE, Zhang S, Merritt ME, Sherry AD. Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI. Magn. Reson. Med. 2005; 53: 790-799.
-
(2005)
Magn. Reson. Med.
, vol.53
, pp. 790-799
-
-
Woessner, D.E.1
Zhang, S.2
Merritt, M.E.3
Sherry, A.D.4
-
26
-
-
55749088003
-
Four-pool modeling of proton exchange processes in biological systems in the presence of MRI-paramagnetic chemical exchange saturation transfer (PARACEST) agents
-
Li AX, Hudson RHE, Barrett JW, Jones CK, Pasternak SH, Bartha R. Four-pool modeling of proton exchange processes in biological systems in the presence of MRI-paramagnetic chemical exchange saturation transfer (PARACEST) agents. Magn. Reson. Med. 2008; 60: 1197-1206.
-
(2008)
Magn. Reson. Med.
, vol.60
, pp. 1197-1206
-
-
Li, A.X.1
Hudson, R.H.E.2
Barrett, J.W.3
Jones, C.K.4
Pasternak, S.H.5
Bartha, R.6
-
27
-
-
35048879622
-
Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain
-
Hua J, Jones CK, Blakeley J, Smith SA, van Zijl PCM, Zhou J. Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain. Magn. Reson. Med. 2007; 58: 786-793.
-
(2007)
Magn. Reson. Med.
, vol.58
, pp. 786-793
-
-
Hua, J.1
Jones, C.K.2
Blakeley, J.3
Smith, S.A.4
van Zijl, P.C.M.5
Zhou, J.6
-
28
-
-
0036828879
-
Fast robust automated brain extraction
-
Smith SM. Fast robust automated brain extraction. Hum. Brain Mapp. 2002; 17: 143-155.
-
(2002)
Hum. Brain Mapp.
, vol.17
, pp. 143-155
-
-
Smith, S.M.1
-
29
-
-
0036425968
-
Improved optimization for the robust and accurate linear registration and motion correction of brain images
-
Jenkinson M, Bannister P, Brady M, Smith S. Improved optimization for the robust and accurate linear registration and motion correction of brain images. Neuroimage 2002; 17: 825-841.
-
(2002)
Neuroimage
, vol.17
, pp. 825-841
-
-
Jenkinson, M.1
Bannister, P.2
Brady, M.3
Smith, S.4
-
31
-
-
0034745001
-
Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm
-
Zhang Y, Brady M, Smith S. Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm. IEEE Trans. Med. Imaging 2001; 20: 45-57.
-
(2001)
IEEE Trans. Med. Imaging
, vol.20
, pp. 45-57
-
-
Zhang, Y.1
Brady, M.2
Smith, S.3
-
32
-
-
84927797532
-
Quantification of amide proton transfer effect pre- and post-gadolinium contrast agent administration
-
doi: 10.1002/jmri.24441.
-
Tee YK, Donahue MJ, Harston GW, Payne SJ, Chappell MA. Quantification of amide proton transfer effect pre- and post-gadolinium contrast agent administration. J. Magn. Reson. Imaging 2013; doi: 10.1002/jmri.24441.
-
(2013)
J. Magn. Reson. Imaging
-
-
Tee, Y.K.1
Donahue, M.J.2
Harston, G.W.3
Payne, S.J.4
Chappell, M.A.5
-
33
-
-
80054810981
-
Amide proton transfer imaging with improved robustness to magnetic field inhomogeneity and magnetization transfer asymmetry using saturation with frequency alternating RF irradiation
-
Scheidegger R, Vinogradov E, Alsop DC. Amide proton transfer imaging with improved robustness to magnetic field inhomogeneity and magnetization transfer asymmetry using saturation with frequency alternating RF irradiation. Magn. Reson. Med. 2011; 66: 1275-1285.
-
(2011)
Magn. Reson. Med.
, vol.66
, pp. 1275-1285
-
-
Scheidegger, R.1
Vinogradov, E.2
Alsop, D.C.3
-
34
-
-
84874383842
-
MR imaging of the amide-proton transfer effect and the pH-insensitive nuclear Overhauser effect at 9.4T
-
Jin T, Wang P, Zong A, Kim S. MR imaging of the amide-proton transfer effect and the pH-insensitive nuclear Overhauser effect at 9.4T. Magn. Reson. Med. 2012; 69: 760-770.
-
(2012)
Magn. Reson. Med.
, vol.69
, pp. 760-770
-
-
Jin, T.1
Wang, P.2
Zong, A.3
Kim, S.4
-
35
-
-
84881140299
-
APT-weighted and NOE-weighted image contrasts in glioma with different RF saturation powers based on magnetization transfer ratio asymmetry analyses
-
Zhou J, Hong X, Zhao X, Gao J, Yuan J. APT-weighted and NOE-weighted image contrasts in glioma with different RF saturation powers based on magnetization transfer ratio asymmetry analyses. Magn. Reson. Med. 2013; 70: 320-327.
-
(2013)
Magn. Reson. Med.
, vol.70
, pp. 320-327
-
-
Zhou, J.1
Hong, X.2
Zhao, X.3
Gao, J.4
Yuan, J.5
-
37
-
-
0035970882
-
Magnetic resonance lipid signals in rat brain after experimental stroke correlate with neutral lipid accumulation
-
Gasparovic C, Rosenberg GA, Wallace JA, Estrada EY, Roberts K, Pastuszyn A, Ahmed W, Graham GD. Magnetic resonance lipid signals in rat brain after experimental stroke correlate with neutral lipid accumulation. Neurosci. Lett. 2001; 301: 87-90.
-
(2001)
Neurosci. Lett.
, vol.301
, pp. 87-90
-
-
Gasparovic, C.1
Rosenberg, G.A.2
Wallace, J.A.3
Estrada, E.Y.4
Roberts, K.5
Pastuszyn, A.6
Ahmed, W.7
Graham, G.D.8
-
38
-
-
79960699853
-
Optimizing pulsed-chemical exchange saturation transfer imaging sequences
-
Zu Z, Li K, Janve VA, Does MD, Gochberg DF. Optimizing pulsed-chemical exchange saturation transfer imaging sequences. Magn. Reson. Med. 2011; 66: 1100-1108.
-
(2011)
Magn. Reson. Med.
, vol.66
, pp. 1100-1108
-
-
Zu, Z.1
Li, K.2
Janve, V.A.3
Does, M.D.4
Gochberg, D.F.5
|