메뉴 건너뛰기




Volumn 66, Issue 4, 2011, Pages 1033-1041

Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3 T

Author keywords

APT; brain tumor; chemical exchange saturation transfer; saturation power; stroke

Indexed keywords

AMIDES; BRAIN; DISEASES; PATHOLOGY; PH EFFECTS; PROTEINS; PROTON TRANSFER; SIGNAL SYSTEMS; TUMORS;

EID: 80052979511     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22891     Document Type: Article
Times cited : (142)

References (40)
  • 1
    • 0037434981 scopus 로고    scopus 로고
    • Disease proteomics
    • DOI 10.1038/nature01514
    • Hanash S,. Disease proteomics. Nature 2003; 422: 226-232. (Pubitemid 36362760)
    • (2003) Nature , vol.422 , Issue.6928 , pp. 226-232
    • Hanash, S.1
  • 2
    • 77956418572 scopus 로고    scopus 로고
    • Glioma proteomics: Status and perspectives
    • Niclou SP, Fack F, Rajcevic U,. Glioma proteomics: status and perspectives. J Proteomics 2010; 73: 1823-1838.
    • (2010) J Proteomics , vol.73 , pp. 1823-1838
    • Niclou, S.P.1    Fack, F.2    Rajcevic, U.3
  • 3
    • 0034145982 scopus 로고    scopus 로고
    • A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
    • Ward KM, Aletras AH, Balaban RS,. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J Magn Reson 2000; 143: 79-87.
    • (2000) J Magn Reson , vol.143 , pp. 79-87
    • Ward, K.M.1    Aletras, A.H.2    Balaban, R.S.3
  • 4
    • 33747238228 scopus 로고    scopus 로고
    • Chemical exchange saturation transfer imaging and spectroscopy
    • Zhou J, van Zijl PC,. Chemical exchange saturation transfer imaging and spectroscopy. Progr NMR Spectrosc 2006; 48: 109-136.
    • (2006) Progr NMR Spectrosc , vol.48 , pp. 109-136
    • Zhou, J.1    Van Zijl, P.C.2
  • 5
    • 50249145152 scopus 로고    scopus 로고
    • Chemical exchange saturation transfer contrast agents for magnetic resonance imaging
    • Sherry AD, Woods M,. Chemical exchange saturation transfer contrast agents for magnetic resonance imaging. Annu Rev Biomed Eng 2008; 10: 391-411.
    • (2008) Annu Rev Biomed Eng , vol.10 , pp. 391-411
    • Sherry, A.D.1    Woods, M.2
  • 6
    • 0035925205 scopus 로고    scopus 로고
    • A novel europium(III)-based MRI contrast agent
    • Zhang S, Winter P, Wu K, Sherry AD,. A novel europium(III)-based MRI contrast agent. J Am Chem Soc 2001; 123 (7): 1517-1578.
    • (2001) J Am Chem Soc , vol.123 , Issue.7 , pp. 1517-1578
    • Zhang, S.1    Winter, P.2    Wu, K.3    Sherry, A.D.4
  • 7
    • 0036204319 scopus 로고    scopus 로고
    • Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications
    • DOI 10.1002/mrm.10106
    • Aime S, Barge A, Delli Castelli D, Fedeli F, Mortillaro A, Nielsen FU, Terreno E,. Paramagnetic lanthanide(III) complexes as pH-sensitive chemical exchange saturation transfer (CEST) contrast agents for MRI applications. Magn Reson Med 2002; 47: 639-648. (Pubitemid 34263776)
    • (2002) Magnetic Resonance in Medicine , vol.47 , Issue.4 , pp. 639-648
    • Aime, S.1    Barge, A.2    Castelli, D.D.3    Fedeli, F.4    Mortillaro, A.5    Nielsen, F.U.6    Terreno, E.7
  • 9
    • 33645772151 scopus 로고    scopus 로고
    • Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): PH calibration for poly- L -lysine and a starburst dendrimer
    • McMahon MT, Gilad AA, Zhou J, Sun PZ, Bulte JWM, van Zijl PCM,. Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): pH calibration for poly- L -lysine and a starburst dendrimer. Magn Reson Med 2006; 55: 836-847.
    • (2006) Magn Reson Med , vol.55 , pp. 836-847
    • McMahon, M.T.1    Gilad, A.A.2    Zhou, J.3    Sun, P.Z.4    Bulte, J.W.M.5    Van Zijl, P.C.M.6
  • 11
    • 36849044069 scopus 로고    scopus 로고
    • Design and characterization of a new irreversible responsive PARACEST MRI contrast agent that detects nitric oxide
    • DOI 10.1002/mrm.21428
    • Liu GS, Li YG, Pagel MD,. Design and characterization of a new irreversible responsive PARACEST MRI contrast agent that detects nitric oxide. Magn Reson Med 2007; 58: 1249-1256. (Pubitemid 350234212)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1249-1256
    • Liu, G.1    Li, Y.2    Pagel, M.D.3
  • 14
    • 0042466426 scopus 로고    scopus 로고
    • Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
    • DOI 10.1038/nm907
    • Zhou J, Payen J, Wilson DA, Traystman RJ, van Zijl PCM,. Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nature Med 2003; 9: 1085-1090. (Pubitemid 37021791)
    • (2003) Nature Medicine , vol.9 , Issue.8 , pp. 1085-1090
    • Zhou, J.1    Payen, J.-F.2    Wilson, D.A.3    Traystman, R.J.4    Van Zijl, P.C.M.5
  • 18
    • 77951974082 scopus 로고    scopus 로고
    • MR imaging of high-grade brain tumors using endogenous protein and peptide-based contrast
    • Wen Z, Hu S, Huang F, Wang X, Guo L, Quan X, Wang S, Zhou J,. MR imaging of high-grade brain tumors using endogenous protein and peptide-based contrast. NeuroImage 2010; 51: 616-622.
    • (2010) NeuroImage , vol.51 , pp. 616-622
    • Wen, Z.1    Hu, S.2    Huang, F.3    Wang, X.4    Guo, L.5    Quan, X.6    Wang, S.7    Zhou, J.8
  • 19
    • 34249276387 scopus 로고    scopus 로고
    • Delineating the Boundary between the ischemic penumbra and regions of oligaemia using pH-weighted magnetic resonance imaging (pHWI)
    • Sun PZ, Zhou J, Sun W, Huang J, van Zijl PCM,. Delineating the Boundary Between the ischemic penumbra and regions of oligaemia using pH-weighted magnetic resonance imaging (pHWI). J Cereb Blood Flow Metab 2007; 27: 1129-1136.
    • (2007) J Cereb Blood Flow Metab , vol.27 , pp. 1129-1136
    • Sun, P.Z.1    Zhou, J.2    Sun, W.3    Huang, J.4    Van Zijl, P.C.M.5
  • 20
    • 34248337816 scopus 로고    scopus 로고
    • Proton transfer ratio, lactate, and intracellular pH in acute cerebral ischemia
    • DOI 10.1002/mrm.21181
    • Jokivarsi KT, Grohn HI, Grohn OH, Kauppinen RA,. Proton transfer ratio, lactate, and intracellular pH in acute cerebral ischemia. Magn Reson Med 2007; 57: 647-653. (Pubitemid 46731789)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.4 , pp. 647-653
    • Jokivarsi, K.T.1    Grohn, H.I.2    Grohn, O.H.3    Kauppinen, R.A.4
  • 21
  • 22
    • 46049087516 scopus 로고    scopus 로고
    • Amide proton transfer imaging of 9L gliosarcoma and human glioblastoma xenografts
    • DOI 10.1002/nbm.1216
    • Salhotra A, Lal B, Laterra J, Sun PZ, van Zijl PCM, Zhou J,. Amide proton transfer imaging of 9L gliosarcoma and human glioblastoma xenografts. NMR Biomed 2008; 21: 489-497. (Pubitemid 351895437)
    • (2008) NMR in Biomedicine , vol.21 , Issue.5 , pp. 489-497
    • Salhotra, A.1    Lal, B.2    Laterra, J.3    Zhe Sun, P.4    Van Zijl, P.C.M.5    Zhou, J.6
  • 24
    • 0026533845 scopus 로고
    • Detection of mobile proteins by proton nuclear magnetic resonance spectroscopy in the guinea pig brain ex vivo and their partial purification
    • Kauppinen RA, Kokko H, Williams SR,. Detection of mobile proteins by proton nuclear magnetic resonance spectroscopy in the guinea pig brain ex vivo and their partial purification. J Neurochem 1992; 58: 967-974.
    • (1992) J Neurochem , vol.58 , pp. 967-974
    • Kauppinen, R.A.1    Kokko, H.2    Williams, S.R.3
  • 25
    • 0031867371 scopus 로고    scopus 로고
    • Proton NMR spectroscopy of solvent-saturable resonances: A new approach to study pH effects in situ
    • DOI 10.1002/mrm.1910400105
    • Mori S, Eleff SM, Pilatus U, Mori N, van Zijl PCM,. Proton NMR spectroscopy of solvent-saturable resonance: a new approach to study pH effects in situ. Magn Reson Med 1998; 40: 36-42. (Pubitemid 28292582)
    • (1998) Magnetic Resonance in Medicine , vol.40 , Issue.1 , pp. 36-42
    • Mori, S.1    Eleff, S.M.2    Pilatus, U.3    Mori, N.4    Van Zijl, P.C.M.5
  • 26
    • 53549103072 scopus 로고    scopus 로고
    • Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner
    • Sun PZ, Benner T, Kumar A, Sorensen AG,. Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner. Magn Reson Med 2008; 60: 834-841.
    • (2008) Magn Reson Med , vol.60 , pp. 834-841
    • Sun, P.Z.1    Benner, T.2    Kumar, A.3    Sorensen, A.G.4
  • 28
    • 70349972122 scopus 로고    scopus 로고
    • Magnetization transfer phenomenon in the human brain at 7T
    • Mougin OE, Coxon RC, Pitiot A, Gowland PA,. Magnetization transfer phenomenon in the human brain at 7T. NeuroImage 2010; 49: 272-281.
    • (2010) NeuroImage , vol.49 , pp. 272-281
    • Mougin, O.E.1    Coxon, R.C.2    Pitiot, A.3    Gowland, P.A.4
  • 29
    • 77956368292 scopus 로고    scopus 로고
    • Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain
    • Zhu H, Jones CK, van Zijl PCM, Barker PB, Zhou J,. Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain. Magn Reson Med 2010; 64: 638-644.
    • (2010) Magn Reson Med , vol.64 , pp. 638-644
    • Zhu, H.1    Jones, C.K.2    Van Zijl, P.C.M.3    Barker, P.B.4    Zhou, J.5
  • 30
    • 0035047624 scopus 로고    scopus 로고
    • Magnetization transfer in MRI: A review
    • DOI 10.1002/nbm.683
    • Henkelman RM, Stanisz GJ, Graham SJ,. Magnetization transfer in MRI: a review. NMR Biomed 2001; 14: 57-64. (Pubitemid 32401348)
    • (2001) NMR in Biomedicine , vol.14 , Issue.2 , pp. 57-64
    • Henkelman, R.M.1    Stanisz, G.J.2    Graham, S.J.3
  • 31
    • 35048879622 scopus 로고    scopus 로고
    • Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain
    • DOI 10.1002/mrm.21387
    • Hua J, Jones CK, Blakeley J, Smith SA, van Zijl PCM, Zhou J,. Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain. Magn Reson Med 2007; 58: 786-793. (Pubitemid 47556884)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.4 , pp. 786-793
    • Hua, J.1    Jones, C.K.2    Blakeley, J.3    Smith, S.A.4    Van Zijl, P.C.M.5    Zhou, J.6
  • 32
    • 0032964687 scopus 로고    scopus 로고
    • The characterization of human brain tumor using magnetization transfer technique in magnetic resonance imaging
    • Okumura A, Takenaka K, Nishimura Y, Asano Y, Sakai N, Kuwata K, Era S,. The characterization of human brain tumor using magnetization transfer technique in magnetic resonance imaging. Neurol Res 1999; 21: 250-254. (Pubitemid 29205444)
    • (1999) Neurological Research , vol.21 , Issue.3 , pp. 250-254
    • Okumura, A.1    Takenaka, K.2    Nishimura, Y.3    Asano, Y.4    Sakai, N.5    Kuwata, K.6    Era, S.7
  • 37
    • 2342511016 scopus 로고    scopus 로고
    • Quantitative Description of Proton Exchange Processes between Water and Endogenous and Exogenous Agents for WEX, CEST, and APT Experiments
    • DOI 10.1002/mrm.20048
    • Zhou J, Wilson DA, Sun PZ, Klaus JA, van Zijl PCM,. Quantitative description of proton exchange processes between water and endogenous and exogenous agents for WEX, CEST, and APT experiments. Magn Reson Med 2004; 51: 945-952. (Pubitemid 38580606)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.5 , pp. 945-952
    • Zhou, J.1    Wilson, D.A.2    Sun, P.Z.3    Klaus, J.A.4    Van Zijl, P.C.M.5
  • 38
    • 0025771650 scopus 로고
    • Are cancer cells acidic?
    • Griffiths JR,. Are cancer cells acidic? Br J Cancer 1991; 64: 425-427.
    • (1991) Br J Cancer , vol.64 , pp. 425-427
    • Griffiths, J.R.1
  • 39
    • 21244455698 scopus 로고    scopus 로고
    • Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments
    • DOI 10.1016/j.jmr.2005.04.005, PII S109078070500128X
    • Sun PZ, van Zijl PCM, Zhou J,. Optimization of the irradiation power in chemical exchange dependent saturation transfer (CEST) experiments. J Magn Reson 2005; 175: 193-200. (Pubitemid 40891674)
    • (2005) Journal of Magnetic Resonance , vol.175 , Issue.2 , pp. 193-200
    • Sun, P.Z.1    Van Zijl, P.C.M.2    Zhou, J.3
  • 40
    • 33846784003 scopus 로고    scopus 로고
    • Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia
    • DOI 10.1002/mrm.21151
    • Sun PZ, Zhou J, Huang J, van Zijl P,. Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia. Magn Reson Med 2007; 57: 405-410. (Pubitemid 46214544)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.2 , pp. 405-410
    • Sun, P.Z.1    Zhou, J.2    Huang, J.3    Van Zijl, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.