메뉴 건너뛰기




Volumn 2014, Issue , 2014, Pages

Humidification during mechanical ventilation in the adult patient

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTIFICIAL VENTILATION; HEALTH CARE QUALITY; HEAT; HEATING; HUMAN; HUMIDIFIER; HUMIDITY; HYPOPHARYNX; INTENSIVE CARE UNIT; MOISTURE; MOUTH; NOSE; PATIENT MONITORING; PNEUMONIA; RESPIRATION CONTROL; RESPIRATORY CARE; REVIEW; TRACHEA; UPPER RESPIRATORY TRACT; VAPORIZER; BIOMEDICAL TECHNOLOGY ASSESSMENT; DEVICE FAILURE ANALYSIS; DEVICES; EQUIPMENT DESIGN; FEMALE; MALE; PROCEDURES; RESPIRATORY INSUFFICIENCY; WATER VAPOR;

EID: 84904092758     PISSN: 23146133     EISSN: 23146141     Source Type: Journal    
DOI: 10.1155/2014/715434     Document Type: Review
Times cited : (54)

References (86)
  • 1
    • 0025775594 scopus 로고
    • History of anesthesia in Germany
    • 10.1016/0952-8180(91)90167-L 2-s2.0-0025775594
    • Wawersik J., History of anesthesia in Germany. Journal of Clinical Anesthesia 1991 3 3 235 244 10.1016/0952-8180(91)90167-L 2-s2.0-0025775594
    • (1991) Journal of Clinical Anesthesia , vol.3 , Issue.3 , pp. 235-244
    • Wawersik, J.1
  • 2
    • 0015396511 scopus 로고
    • Effects of dry anesthetic gases on tracheobronchial ciliated epithelium
    • 10.1097/00000542-197209000-00010 2-s2.0-0015396511
    • Chalon J., Loew D. A., Malebranche J., Effects of dry anesthetic gases on tracheobronchial ciliated epithelium. Anesthesiology 1972 37 3 338 343 10.1097/00000542-197209000-00010 2-s2.0-0015396511
    • (1972) Anesthesiology , vol.37 , Issue.3 , pp. 338-343
    • Chalon, J.1    Loew, D.A.2    Malebranche, J.3
  • 3
    • 0006253247 scopus 로고
    • Effects of dry anaesthetic gases on the respiratory mucous membrane
    • 10.1016/S0140-6736(62)91187-X 2-s2.0-0006253247
    • Burton J. D. K., Effects of dry anaesthetic gases on the respiratory mucous membrane. The Lancet 1962 279 7223 235 238 10.1016/S0140-6736(62)91187-X 2-s2.0-0006253247
    • (1962) The Lancet , vol.279 , Issue.7223 , pp. 235-238
    • Burton, J.D.K.1
  • 4
    • 0017752489 scopus 로고
    • Optimum humidification of air administered to a tracheostomy in dogs. Scanning electron microscopy and surfactant studies
    • Tsuda T., Noguchi H., Takumi Y., Aochi O., Optimum humidification of air administered to a tracheostomy in dogs. Scanning electron microscopy and surfactant studies. British Journal of Anaesthesia 1977 49 10 965 977 10.1093/bja/49.10.965 2-s2.0-0017752489 (Pubitemid 8192475)
    • (1977) British Journal of Anaesthesia , vol.49 , Issue.10 , pp. 965-977
    • Tsuda, T.1    Noguchi, H.2    Takumi, Y.3    Aochi, O.4
  • 5
    • 0022526916 scopus 로고
    • Effect of breathing dry air on structure and function of airways
    • van Oostdam J. C., Walker D. C., Knudson K., Dirks P., Dahlby R. W., Hogg J. C., Effect of breathing dry air on structure and function of airways. Journal of Applied Physiology 1986 61 1 312 317 2-s2.0-0022526916 (Pubitemid 16055694)
    • (1986) Journal of Applied Physiology , vol.61 , Issue.1 , pp. 312-317
    • Van Oostdam, J.C.1    Walker, D.C.2    Knudson, K.3
  • 6
    • 0016716811 scopus 로고
    • A comparative study of the effects of dry vs. Humidified ventilation on canine lungs
    • 2-s2.0-0016716811
    • Fonkalsrud E. W., Sanchez M., Higashijima I., Arima E., A comparative study of the effects of dry vs. humidified ventilation on canine lungs. Surgery 1975 78 3 373 380 2-s2.0-0016716811
    • (1975) Surgery , vol.78 , Issue.3 , pp. 373-380
    • Fonkalsrud, E.W.1    Sanchez, M.2    Higashijima, I.3    Arima, E.4
  • 7
    • 33645357263 scopus 로고
    • A technique for adequate humidification with mechanical respirators
    • 2-s2.0-33645357263
    • Bryant L. R., A technique for adequate humidification with mechanical respirators. The Journal of Thoracic and Cardiovascular Surgery 1963 46 404 407 2-s2.0-33645357263
    • (1963) The Journal of Thoracic and Cardiovascular Surgery , vol.46 , pp. 404-407
    • Bryant, L.R.1
  • 8
    • 0016702558 scopus 로고
    • Effect of dry and humidified gases on the respiratory epithelium in rabbits
    • 10.1016/0022-3468(75)90360-7 2-s2.0-0016702558
    • Marfatia S., Donahoe P. K., Hendren W. H., Effect of dry and humidified gases on the respiratory epithelium in rabbits. Journal of Pediatric Surgery 1975 10 5 583 592 10.1016/0022-3468(75)90360-7 2-s2.0-0016702558
    • (1975) Journal of Pediatric Surgery , vol.10 , Issue.5 , pp. 583-592
    • Marfatia, S.1    Donahoe, P.K.2    Hendren, W.H.3
  • 9
    • 0016611688 scopus 로고
    • The influence of varying air humidity on mucociliary activity
    • 10.3109/00016487509124665 2-s2.0-0016611688
    • Mercke U., The influence of varying air humidity on mucociliary activity. Acta Oto-Laryngologica 1975 79 1-2 133 139 10.3109/00016487509124665 2-s2.0-0016611688
    • (1975) Acta Oto-Laryngologica , vol.79 , Issue.1-2 , pp. 133-139
    • Mercke, U.1
  • 10
    • 0023135498 scopus 로고
    • A rational basis for humidity therapy
    • Chatburn R. L., Primiano F. P. Jr., A rational basis for humidity therapy. Respiratory Care 1987 32 4 249 254 2-s2.0-0023135498 (Pubitemid 17059204)
    • (1987) Respiratory Care , vol.32 , Issue.4 , pp. 249-254
    • Chatburn, R.L.1    Primiano Jr., F.P.2
  • 11
    • 84860503092 scopus 로고    scopus 로고
    • Humidification during invasive and noninvasive mechanical ventilation: 2012
    • American Association for Respiratory Care 10.4187/respcare.01766
    • American Association for Respiratory Care, Restrepo R. D., Walsh B. K., Humidification during invasive and noninvasive mechanical ventilation: 2012. Respiratory Care 2012 57 5 782 788 10.4187/respcare.01766
    • (2012) Respiratory Care , vol.57 , Issue.5 , pp. 782-788
    • Restrepo, R.D.1    Walsh, B.K.2
  • 13
    • 1942421832 scopus 로고    scopus 로고
    • Liquid secretion properties of airway submucosal glands
    • DOI 10.1113/jphysiol.2003.052779
    • Ballard S. T., Inglis S. K., Liquid secretion properties of airway submucosal glands. Journal of Physiology 2004 556 1 1 10 10.1113/jphysiol.2003. 052779 2-s2.0-1942421832 (Pubitemid 38515164)
    • (2004) Journal of Physiology , vol.556 , Issue.1 , pp. 1-10
    • Ballard, S.T.1    Inglis, S.K.2
  • 14
    • 0023738317 scopus 로고
    • A review of the mechanisms and methods of humidification of inspired gases
    • DOI 10.1007/BF00254114
    • Shelly M. P., Lloyd G. M., Park G. R., A review of the mechanisms and methods of humidification of inspired gases. Intensive Care Medicine 1988 14 1 1 9 10.1007/BF00254114 2-s2.0-0023738317 (Pubitemid 18003829)
    • (1988) Intensive Care Medicine , vol.14 , Issue.1 , pp. 1-9
    • Shelly, M.P.1    Lloyd, G.M.2    Park, G.R.3
  • 15
    • 0033010764 scopus 로고    scopus 로고
    • Humidification for patients with artificial airways
    • 2-s2.0-0033010764
    • Branson R. D., Humidification for patients with artificial airways. Respiratory Care 1999 44 6 630 641 2-s2.0-0033010764
    • (1999) Respiratory Care , vol.44 , Issue.6 , pp. 630-641
    • Branson, R.D.1
  • 16
    • 0034517338 scopus 로고    scopus 로고
    • Exercise-induced asthma: Is it the right diagnosis in elite athletes?
    • DOI 10.1067/mai.2000.108914
    • Anderson S. D., Holzer K., Exercise-induced asthma: is it the right diagnosis in elite athletes? The Journal of Allergy and Clinical Immunology 2000 106 3 419 428 10.1067/mai.2000.108914 2-s2.0-0034517338 (Pubitemid 32037692)
    • (2000) Journal of Allergy and Clinical Immunology , vol.106 , Issue.3 , pp. 419-428
    • Anderson, S.D.1    Holzer, K.2
  • 18
    • 84880712133 scopus 로고    scopus 로고
    • Mechanical ventilation with heated humidifiers: Measurements of condensed water mass within the breathing circuit according to ventilatory settings
    • 10.1088/0967-3334/34/7/813 2-s2.0-84880712133
    • Schena E., Saccomandi P., Cappelli S., Silvestri S., Mechanical ventilation with heated humidifiers: measurements of condensed water mass within the breathing circuit according to ventilatory settings. Physiological Measurement 2013 34 7, article 813 10.1088/0967-3334/34/7/813 2-s2.0-84880712133
    • (2013) Physiological Measurement , vol.34 , Issue.7 ARTICLE 813
    • Schena, E.1    Saccomandi, P.2    Cappelli, S.3    Silvestri, S.4
  • 22
    • 66849083885 scopus 로고    scopus 로고
    • Y-piece temperature and humidification during mechanical ventilation
    • 2-s2.0-66849083885
    • Solomita M., Daroowalla F., LeBlanc D. S., Smaldone G. C., Y-piece temperature and humidification during mechanical ventilation. Respiratory Care 2009 54 4 480 486 2-s2.0-66849083885
    • (2009) Respiratory Care , vol.54 , Issue.4 , pp. 480-486
    • Solomita, M.1    Daroowalla, F.2    Leblanc, D.S.3    Smaldone, G.C.4
  • 24
    • 33644604269 scopus 로고    scopus 로고
    • Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia
    • 10.1097/01.CCM.0000201887.51076.31 2-s2.0-33644604269
    • Boots R. J., George N., Faoagali J. L., Druery J., Dean K., Heller R. F., Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia. Critical Care Medicine 2006 34 3 687 693 10.1097/01.CCM.0000201887.51076.31 2-s2.0-33644604269
    • (2006) Critical Care Medicine , vol.34 , Issue.3 , pp. 687-693
    • Boots, R.J.1    George, N.2    Faoagali, J.L.3    Druery, J.4    Dean, K.5    Heller, R.F.6
  • 25
    • 84937785189 scopus 로고    scopus 로고
    • Condensation in inspiratory and expiratory circuits of heated wire humidifiers, evaluation of a new expiratory, "porous", circuit and of new humidification compensation systems
    • San Diego, Calif, USA
    • Lellouche F., Lyazidi A., Rodriguez P., Brochard L., Condensation in inspiratory and expiratory circuits of heated wire humidifiers, evaluation of a new expiratory, "porous" circuit and of new humidification compensation systems. Proceedings of the 100th International Conference of the American Thoracic Society 2005 San Diego, Calif, USA
    • (2005) Proceedings of the 100th International Conference of the American Thoracic Society
    • Lellouche, F.1    Lyazidi, A.2    Rodriguez, P.3    Brochard, L.4
  • 26
    • 0026029019 scopus 로고
    • Resistance of humidifiers, and inspiratory work imposed by a ventilator-humidifier circuit
    • 10.1093/bja/66.2.258 2-s2.0-0026029019
    • Oh T. E., Lin E. S., Bhatt S., Resistance of humidifiers, and inspiratory work imposed by a ventilator-humidifier circuit. British Journal of Anaesthesia 1991 66 2 258 263 10.1093/bja/66.2.258 2-s2.0-0026029019
    • (1991) British Journal of Anaesthesia , vol.66 , Issue.2 , pp. 258-263
    • Oh, T.E.1    Lin, E.S.2    Bhatt, S.3
  • 27
    • 0036281138 scopus 로고    scopus 로고
    • Evaluation of heated humidifiers for use on intubated patients: A comparative study of humidifying efficiency, flow resistance, and alarm functions using a lung model
    • DOI 10.1007/s00134-002-1275-9
    • Rathgeber J., Kazmaier S., Penack O., Züchner K., Evaluation of heated humidifiers for use on intubated patients: a comparative study of humidifying efficiency, flow resistance, and alarm functions using a lung model. Intensive Care Medicine 2002 28 6 731 739 10.1007/s00134-002-1275-9 2-s2.0-0036281138 (Pubitemid 34639486)
    • (2002) Intensive Care Medicine , vol.28 , Issue.6 , pp. 731-739
    • Rathgeber, J.1    Kazmaier, S.2    Penack, O.3    Zuchner, K.4
  • 28
    • 0022527566 scopus 로고
    • Bubbling humidifiers produce microaerosols which can carry bacteria
    • Rhame F. S., Streifel A., McComb C., Boyle M., Bubbling humidifiers produce microaerosols which can carry bacteria. Infection Control 1986 7 8 403 407 2-s2.0-0022527566 (Pubitemid 16010164)
    • (1986) Infection Control , vol.7 , Issue.8 , pp. 403-407
    • Rhame, F.S.1    Streifel, A.2    McComb, C.3    Boyle, M.4
  • 29
    • 0028968062 scopus 로고
    • The effects of circuit and humidifier type on contamination potential during mechanical ventilation: A laboratory study
    • 10.1016/0196-6553(95)90096-9 2-s2.0-0028968062
    • Gilmour I. J., Boyle M. J., Streifel A., McComb R. C., The effects of circuit and humidifier type on contamination potential during mechanical ventilation: a laboratory study. The American Journal of Infection Control 1995 23 2 65 72 10.1016/0196-6553(95)90096-9 2-s2.0-0028968062
    • (1995) The American Journal of Infection Control , vol.23 , Issue.2 , pp. 65-72
    • Gilmour, I.J.1    Boyle, M.J.2    Streifel, A.3    McComb, R.C.4
  • 30
    • 84904102223 scopus 로고    scopus 로고
    • http://www.cdc.gov/hicpac/pdf/guidelines/HApneu2003guidelines.pdf
  • 31
    • 0023854457 scopus 로고
    • Melted delivery hose - A complication of a heated humidifier
    • Wong D. H. W., Melted delivery hose-a complication of a heated humidifier. Canadian Journal of Anaesthesia 1988 35 2 183 186 10.1007/BF03010661 2-s2.0-0023854457 (Pubitemid 18086006)
    • (1988) Canadian Journal of Anaesthesia , vol.35 , Issue.2 , pp. 183-186
    • Wong, D.H.W.1
  • 32
    • 34248176183 scopus 로고    scopus 로고
    • Moisturizing and mechanical characteristics of a new counter-flow type heated humidifier
    • DOI 10.1093/bja/aem006
    • Schumann S., Stahl C. A., Möller K., Priebe H.-J., Guttmann J., Moisturizing and mechanical characteristics of a new counter-flow type heated humidifier. British Journal of Anaesthesia 2007 98 4 531 538 10.1093/bja/aem006 2-s2.0-34248176183 (Pubitemid 47072656)
    • (2007) British Journal of Anaesthesia , vol.98 , Issue.4 , pp. 531-538
    • Schumann, S.1    Stahl, C.A.2    Moller, K.3    Priebe, H.-J.4    Guttmann, J.5
  • 33
    • 77952306936 scopus 로고    scopus 로고
    • Use of a new novel humidification system with high frequency percussive ventilation in a patient with inhalation injury
    • 10.1097/BCR.0b013e3181db51e5 2-s2.0-77952306936
    • Jones S. W., Short K. A., Joseph M., Sommer C., Cairns B. A., Use of a new novel humidification system with high frequency percussive ventilation in a patient with inhalation injury. Journal of Burn Care and Research 2010 31 3 499 502 10.1097/BCR.0b013e3181db51e5 2-s2.0-77952306936
    • (2010) Journal of Burn Care and Research , vol.31 , Issue.3 , pp. 499-502
    • Jones, S.W.1    Short, K.A.2    Joseph, M.3    Sommer, C.4    Cairns, B.A.5
  • 34
    • 79955976935 scopus 로고    scopus 로고
    • Comparison of three humidifiers during high-frequency percussive ventilation using the VDR-4 fail-safe Breathing Circuit Hub
    • 10.1097/BCR.0b013e318217f864 2-s2.0-79955976935
    • Tiffin N. H., Short K. A., Jones S. W., Cairns B. A., Comparison of three humidifiers during high-frequency percussive ventilation using the VDR-4 fail-safe Breathing Circuit Hub. Journal of Burn Care and Research 2011 32 3 e45 e50 10.1097/BCR.0b013e318217f864 2-s2.0-79955976935
    • (2011) Journal of Burn Care and Research , vol.32 , Issue.3
    • Tiffin, N.H.1    Short, K.A.2    Jones, S.W.3    Cairns, B.A.4
  • 35
    • 0009466476 scopus 로고
    • Assessment of condenser-humidifiers with special reference to a multiplegauze model
    • 10.1136/bmj.1.5326.300 2-s2.0-0009466476
    • Mapleson W. W., Morgan J. G., Hillard E. K., Assessment of condenser-humidifiers with special reference to a multiplegauze model. British Medical Journal 1963 1 5326 300 305 10.1136/bmj.1.5326.300 2-s2.0-0009466476
    • (1963) British Medical Journal , vol.1 , Issue.5326 , pp. 300-305
    • Mapleson, W.W.1    Morgan, J.G.2    Hillard, E.K.3
  • 36
    • 1842370010 scopus 로고
    • The resistance to airflow of tracheostomy tubes, connections, and heat and moisture exchangers
    • 10.1093/bja/37.6.454 2-s2.0-1842370010
    • Hingorani B. K., The resistance to airflow of tracheostomy tubes, connections, and heat and moisture exchangers. British Journal of Anaesthesia 1965 37 6 454 463 10.1093/bja/37.6.454 2-s2.0-1842370010
    • (1965) British Journal of Anaesthesia , vol.37 , Issue.6 , pp. 454-463
    • Hingorani, B.K.1
  • 37
    • 0030443959 scopus 로고    scopus 로고
    • Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices
    • DOI 10.1097/00000542-199612000-00015
    • Villafane M. C., Cinnella G., Lofaso F., Isabey D., Harf A., Lemaire F., Brochard L., Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices. Anesthesiology 1996 85 6 1341 1349 10.1097/00000542-199612000-00015 2-s2.0-0030443959 (Pubitemid 27014661)
    • (1996) Anesthesiology , vol.85 , Issue.6 , pp. 1341-1349
    • Villafane, M.C.1    Cinnella, G.2    Lofaso, F.3    Isabey, D.4    Harf, A.5    Lemaire, F.6    Brochard, L.7
  • 38
    • 0028889953 scopus 로고
    • Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices
    • 10.1016/0195-6701(95)90292-9 2-s2.0-0028889953
    • Vandenbroucke-Grauls C. M., Teeuw K. B., Ballemans K., Lavooij C., Cornelisse P. B., Verhoef J., Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices. Journal of Hospital Infection 1995 29 1 45 56 10.1016/0195-6701(95)90292-9 2-s2.0-0028889953
    • (1995) Journal of Hospital Infection , vol.29 , Issue.1 , pp. 45-56
    • Vandenbroucke-Grauls, C.M.1    Teeuw, K.B.2    Ballemans, K.3    Lavooij, C.4    Cornelisse, P.B.5    Verhoef, J.6
  • 39
    • 60249083574 scopus 로고    scopus 로고
    • Humidification performance of 48 passive airway humidifiers: Comparison with manufacturer data
    • 10.1378/chest.08-0679 2-s2.0-60249083574
    • Lellouche F., Taillé S., Lefrançois F., Deye N., Maggiore S. M., Jouvet P., Ricard J., Fumagalli B., Brochard L., Humidification performance of 48 passive airway humidifiers: comparison with manufacturer data. Chest 2009 135 2 276 286 10.1378/chest.08-0679 2-s2.0-60249083574
    • (2009) Chest , vol.135 , Issue.2 , pp. 276-286
    • Lellouche, F.1    Taillé, S.2    Lefrançois, F.3    Deye, N.4    Maggiore, S.M.5    Jouvet, P.6    Ricard, J.7    Fumagalli, B.8    Brochard, L.9
  • 40
    • 0025015270 scopus 로고
    • Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
    • Martin C., Perrin G., Gevaudan M. J., Saux P., Gouin F., Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 1990 97 1 144 149 10.1378/chest.97.1.144 2-s2.0-0025015270 (Pubitemid 20023508)
    • (1990) Chest , vol.97 , Issue.1 , pp. 144-149
    • Martin, C.1    Perrin, G.2    Gevaudan, M.-J.3    Saux, P.4    Gouin, F.5
  • 41
    • 0036218631 scopus 로고    scopus 로고
    • TM: A clinical and bacteriological evaluation over 96 h
    • DOI 10.1007/s00134-001-1193-2
    • Thomachot L., Viviand X., Boyadjiev I., Vialet R., Martin C., The combination of a heat and moisture exchanger and a BoosterTM: a clinical and bacteriological evaluation over 96 h. Intensive Care Medicine 2002 28 2 147 153 10.1007/s00134-001-1193-2 2-s2.0-0036218631 (Pubitemid 34293826)
    • (2002) Intensive Care Medicine , vol.28 , Issue.2 , pp. 147-153
    • Thomachot, L.1    Viviand, X.2    Boyadjiev, I.3    Vialet, R.4    Martin, C.5
  • 43
    • 84899706308 scopus 로고    scopus 로고
    • Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers
    • Lellouche F., Qader S., Taille S., Lyazidi A., Brochard L., Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers. Respiratory Care 2014 59 5 637 643
    • (2014) Respiratory Care , vol.59 , Issue.5 , pp. 637-643
    • Lellouche, F.1    Qader, S.2    Taille, S.3    Lyazidi, A.4    Brochard, L.5
  • 44
  • 45
    • 0035221462 scopus 로고    scopus 로고
    • A randomized, controlled, clinical trial of a chemically-reactive heated humidifier
    • Broach S. D., Durbin C. G. Jr., A randomized, controlled, clinical trial of a chemically-reactive heated humidifier. Respiratory Care 2001 46 1 37 42 2-s2.0-0035221462 (Pubitemid 33759341)
    • (2001) Respiratory Care , vol.46 , Issue.1 , pp. 37-42
    • Broach, S.D.1    Durbin Jr., C.G.2
  • 46
    • 33745672332 scopus 로고    scopus 로고
    • Consequences of Under- And Over-humidification
    • DOI 10.1016/j.rcc.2006.03.010, PII S1078533706000311
    • Sottiaux T. M., Consequences of Under- and Over-humidification. Respiratory Care Clinics of North America 2006 12 2 233 252 10.1016/j.rcc.2006. 03.010 2-s2.0-33745672332 (Pubitemid 43971356)
    • (2006) Respiratory Care Clinics of North America , vol.12 , Issue.2 , pp. 233-252
    • Sottiaux, T.M.1
  • 47
    • 0029081287 scopus 로고
    • Albuterol delivery in a model of mechanical ventilation: Comparison of metered-dose inhaler and nebulizer efficiency
    • 10.1164/ajrccm.152.4.7551401 2-s2.0-0029081287
    • Diot P., Morra L., Smaldone G. C., Albuterol delivery in a model of mechanical ventilation: comparison of metered-dose inhaler and nebulizer efficiency. American Journal of Respiratory and Critical Care Medicine 1995 152 4, part 1 1391 1394 10.1164/ajrccm.152.4.7551401 2-s2.0-0029081287
    • (1995) American Journal of Respiratory and Critical Care Medicine , vol.152 , Issue.4 PART 1 , pp. 1391-1394
    • Diot, P.1    Morra, L.2    Smaldone, G.C.3
  • 48
    • 38449099368 scopus 로고    scopus 로고
    • Secretion management in the mechanically ventilated patient
    • 2-s2.0-38449099368
    • Branson R. D., Secretion management in the mechanically ventilated patient. Respiratory Care 2007 52 10 1328 1347 2-s2.0-38449099368
    • (2007) Respiratory Care , vol.52 , Issue.10 , pp. 1328-1347
    • Branson, R.D.1
  • 49
    • 0033040999 scopus 로고    scopus 로고
    • Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill
    • DOI 10.1378/chest.115.6.1646
    • Ricard J., Markowicz P., Djedaini K., Mier L., Coste F., Dreyfuss D., Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. Chest 1999 115 6 1646 1652 10.1378/chest.115.6.1646 2-s2.0-0033040999 (Pubitemid 29275659)
    • (1999) Chest , vol.115 , Issue.6 , pp. 1646-1652
    • Ricard, J.-D.1    Markowicz, P.2    Djedaini, K.3    Mier, L.4    Coste, F.5    Dreyfuss, D.6
  • 50
    • 0020568546 scopus 로고
    • Laboratory investigation of six artificial noses for use during endotracheal anesthesia
    • Weeks D. B., Ramsey F. M., Laboratory investigation of six artificial noses for use during endotracheal anesthesia. Anesthesia and Analgesia 1983 62 8 758 763 2-s2.0-0020568546 (Pubitemid 13027133)
    • (1983) Anesthesia and Analgesia , vol.62 , Issue.8 , pp. 758-763
    • Weeks, D.B.1    Ramsey, F.M.2
  • 51
    • 0023907089 scopus 로고
    • Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit
    • Cohen I. L., Weinberg P. F., Fein I. A., Rowinski G. S., Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Critical Care Medicine 1988 16 3 277 279 10.1097/00003246-198803000-00013 2-s2.0-0023907089 (Pubitemid 18081910)
    • (1988) Critical Care Medicine , vol.16 , Issue.3 , pp. 277-279
    • Cohen, I.L.1    Weinberg, P.F.2    Fein, I.A.3    Rowinski, G.S.4
  • 52
    • 0026611461 scopus 로고
    • Comparison of hydrophogic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation
    • 10.1007/BF01705040 2-s2.0-0026611461
    • Roustan J. P., Kienlen J., Aubas P., Du Cailar J., Comparison of hydrophogic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Medicine 1992 18 2 97 100 10.1007/BF01705040 2-s2.0-0026611461
    • (1992) Intensive Care Medicine , vol.18 , Issue.2 , pp. 97-100
    • Roustan, J.P.1    Kienlen, J.2    Aubas, P.3    Du Cailar, J.4
  • 53
    • 0020644519 scopus 로고
    • A comparative evaluaton of disposable humidifiers
    • Mebius C., A comparative evaluaton of disposable humidifiers. Acta Anaesthesiologica Scandinavica 1983 27 5 403 409 10.1111/j.1399-6576.1983. tb01977.x 2-s2.0-0020644519 (Pubitemid 13015669)
    • (1983) Acta Anaesthesiologica Scandinavica , vol.27 , Issue.5 , pp. 403-409
    • Mebius, C.1
  • 54
    • 0028989702 scopus 로고
    • Heat and moisture exchangers for conditioning of inspired air of intubated patients in intensive care. The humidification properties of passive air exchangers under clinical conditions
    • 10.1007/s001010050154 2-s2.0-0028989702
    • Rathgeber J., Zuchner K., Kietzmann D., Weyland W., Heat and moisture exchangers for conditioning of inspired air of intubated patients in intensive care. The humidification properties of passive air exchangers under clinical conditions. Anaesthesist 1995 44 4 274 283 10.1007/s001010050154 2-s2.0-0028989702
    • (1995) Anaesthesist , vol.44 , Issue.4 , pp. 274-283
    • Rathgeber, J.1    Zuchner, K.2    Kietzmann, D.3    Weyland, W.4
  • 55
    • 0034112596 scopus 로고    scopus 로고
    • Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
    • Davis K. Jr., Evans S. L., Campbell R. S., Johannigman J. A., Luchette F. A., Porembka D. T., Branson R. D., Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Critical Care Medicine 2000 28 5 1412 1418 10.1097/00003246- 200005000-00026 2-s2.0-0034112596 (Pubitemid 30324516)
    • (2000) Critical Care Medicine , vol.28 , Issue.5 , pp. 1412-1418
    • Davis Jr., K.1    Evans, S.L.2    Campbell, R.S.3    Johannigman, J.A.4    Luchette, F.A.5    Porembka, D.T.6    Branson, R.D.7
  • 57
    • 0029174060 scopus 로고
    • Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia
    • Djedaini K., Billiard M., Mier L., Le Bourdelles G., Brun P., Markowicz P., Estagnasie P., Coste F., Boussougant Y., Dreyfuss D., Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. The American Journal of Respiratory and Critical Care Medicine 1995 152 5 1562 1569 10.1164/ajrccm.152. 5.7582295 2-s2.0-0028827735 (Pubitemid 3002094)
    • (1995) Current Opinion in Cell Biology , vol.7 , Issue.6 , pp. 1562-1569
    • Djedaini, K.1    Billiard, M.2    Mier, L.3    Le Bourdelles, G.4    Brun, P.5    Markowicz, P.6    Estagnasie, P.7    Coste, F.8    Boussougant, Y.9    Dreyfuss, D.10
  • 58
    • 0031936853 scopus 로고    scopus 로고
    • Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours
    • DOI 10.1097/00003246-199803000-00018
    • Thomachot L., Vialet R., Viguier J., Sidier B., Roulier P., Martin C., Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours. Critical Care Medicine 1998 26 3 477 481 10.1097/00003246- 199803000-00018 2-s2.0-0031936853 (Pubitemid 28141482)
    • (1998) Critical Care Medicine , vol.26 , Issue.3 , pp. 477-481
    • Thomachot, L.1    Vialet, R.2    Viguier, J.-M.3    Sidier, B.4    Roulier, P.5    Martin, C.6
  • 59
    • 0032705361 scopus 로고    scopus 로고
    • Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: A clinical and microbiological evaluation
    • 10.1007/s001340051051 2-s2.0-0032705361
    • Boisson C., Viviand X., Arnaud S., Thomachot L., Miliani Y., Martin C., Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation. Intensive Care Medicine 1999 25 11 1237 1243 10.1007/s001340051051 2-s2.0-0032705361
    • (1999) Intensive Care Medicine , vol.25 , Issue.11 , pp. 1237-1243
    • Boisson, C.1    Viviand, X.2    Arnaud, S.3    Thomachot, L.4    Miliani, Y.5    Martin, C.6
  • 60
    • 0034103469 scopus 로고    scopus 로고
    • Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: A prospective, randomized study
    • Markowicz P., Ricard J. D., Dreyfuss D., Mier L., Brun P., Coste F., Boussougant Y., Djedaïni K., Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Critical Care Medicine 2000 28 3 665 671 10.1097/00003246-200003000-00011 2-s2.0-0034103469 (Pubitemid 30174260)
    • (2000) Critical Care Medicine , vol.28 , Issue.3 , pp. 665-671
    • Markowicz, P.1    Ricard, J.-D.2    Dreyfuss, D.3    Mier, L.4    Brun, P.5    Coste, F.6    Boussougant, Y.7    Djedaini, K.8
  • 61
    • 0034022538 scopus 로고    scopus 로고
    • Changing heat and moisture exchangers after 96 hours rather than after 24 hours: A clinical and microbiological evaluation
    • Thomachot L., Boisson C., Arnaud S., Michelet P., Cambon S., Martin C., Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Critical Care Medicine 2000 28 3 714 720 10.1097/00003246-200003000-00019 2-s2.0-0034022538 (Pubitemid 30174268)
    • (2000) Critical Care Medicine , vol.28 , Issue.3 , pp. 714-720
    • Thomachot, L.1    Boisson, C.2    Arnaud, S.3    Michelet, P.4    Cambon, S.5    Martin, C.6
  • 62
    • 0036155170 scopus 로고    scopus 로고
    • Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days
    • Thomachot L., Leone M., Razzouk K., Antonini F., Vialet R., Martin C., Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Critical Care Medicine 2002 30 1 232 237 10.1097/00003246- 200201000-00033 2-s2.0-0036155170 (Pubitemid 34112201)
    • (2002) Critical Care Medicine , vol.30 , Issue.1 , pp. 232-237
    • Thomachot, L.1    Leone, M.2    Razzouk, K.3    Antonini, F.4    Vialet, R.5    Martin, C.6
  • 63
    • 0035096607 scopus 로고    scopus 로고
    • Changing patterns of airway accidents in intubated ICU patients
    • DOI 10.1007/s001340000762
    • Kapadia F. N., Bajan K. B., Singh S., Mathew B., Nath A., Wadkar S., Changing patterns of airway accidents in intubated ICU patients. Intensive Care Medicine 2001 27 1 296 300 10.1007/s001340000762 2-s2.0-0035096607 (Pubitemid 32209004)
    • (2001) Intensive Care Medicine , vol.27 , Issue.1 , pp. 296-300
    • Kapadia, F.N.1    Bajan, K.B.2    Singh, S.3    Mathew, B.4    Nath, A.5    Wadkar, S.6
  • 64
    • 33745458492 scopus 로고    scopus 로고
    • Under-humidification and over-humidification during moderate induced hypothermia with usual devices
    • DOI 10.1007/s00134-006-0192-8
    • Lellouche F., Qader S., Taille S., Lyazidi A., Brochard L., Under-humidification and over-humidification during moderate induced hypothermia with usual devices. Intensive Care Medicine 2006 32 7 1014 1021 10.1007/s00134-006-0192-8 2-s2.0-33745458492 (Pubitemid 43952716)
    • (2006) Intensive Care Medicine , vol.32 , Issue.7 , pp. 1014-1021
    • Lellouche, F.1    Qader, S.2    Taille, S.3    Lyazidi, A.4    Brochard, L.5
  • 65
    • 84904111040 scopus 로고    scopus 로고
    • Comparison of conventional heated humidification to a new active heat and moisture exchanger in the ICU
    • Branson R. D., Campbell R. S., Ottaway M., Johannigman J. A., Comparison of conventional heated humidification to a new active heat and moisture exchanger in the ICU. Critical Care 1999 3 supplement 1 P017
    • (1999) Critical Care , vol.3 , Issue.SUPPL. 1
    • Branson, R.D.1    Campbell, R.S.2    Ottaway, M.3    Johannigman, J.A.4
  • 66
    • 34447634744 scopus 로고    scopus 로고
    • And now for the rest of the story
    • Hess D. R., And now for the rest of the story. Respir Care 2002 47 6 696 699
    • (2002) Respir Care , vol.47 , Issue.6 , pp. 696-699
    • Hess, D.R.1
  • 67
    • 0034068580 scopus 로고    scopus 로고
    • The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients
    • Campbell R. S., Davis K. Jr., Johannigman J. A., Branson R. D., The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients. Respiratory Care 2000 45 3 306 312 2-s2.0-0034068580 (Pubitemid 30164249)
    • (2000) Respiratory Care , vol.45 , Issue.3 , pp. 306-312
    • Campbell, R.S.1    Davis Jr., K.2    Johannigman, J.A.3    Branson, R.D.4
  • 68
    • 0346964474 scopus 로고    scopus 로고
    • Influence of the humidification device during acute respiratory distress syndrome
    • DOI 10.1007/s00134-003-1926-5
    • Prat G., Renault A., Tonnelier J., Goetghebeur D., Oger E., Boles J., L'Her E., Influence of the humidification device during acute respiratory distress syndrome. Intensive Care Medicine 2003 29 12 2211 2215 10.1007/s00134-003-1926-5 2-s2.0-0346964474 (Pubitemid 38030674)
    • (2003) Intensive Care Medicine , vol.29 , Issue.12 , pp. 2211-2215
    • Prat, G.1    Renault, A.2    Tonnelier, J.-M.3    Goetghebeur, D.4    Oger, E.5    Boles, J.-M.6    L'Her, E.7
  • 69
    • 0009781817 scopus 로고    scopus 로고
    • Expiratory washout versus optimization of mechanical ventilation during permissive hypercapnia in patients with severe acute respiratory distress syndrome
    • Richecoeur J., Lu Q., Vieira S. R. R., Puybasset L., Kalfon P., Coriat P., Rouby J., Expiratory washout versus optimization of mechanical ventilation during permissive hypercapnia in patients with severe acute respiratory distress syndrome. The American Journal of Respiratory and Critical Care Medicine 1999 160 1 77 85 10.1164/ajrccm.160.1.9809006 2-s2.0-0009781817 (Pubitemid 29326071)
    • (1999) American Journal of Respiratory and Critical Care Medicine , vol.160 , Issue.1 , pp. 77-85
    • Richecoeur, J.1    Lu, Q.2    Vieira, S.R.R.3    Puybasset, L.4    Kalfon, P.5    Coriat, P.6    Rouby, J.-J.7
  • 70
    • 0036448575 scopus 로고    scopus 로고
    • Ability and safety of a heated humidifier to control hypercapnic acidosis in severe ARDS
    • DOI 10.1007/s00134-002-1520-2
    • Prin S., Chergui K., Augarde R., Page B., Jardin F., Vieillard-Baron A., Ability and safety of a heated humidifier to control hypercapnic acidosis in severe ARDS. Intensive Care Medicine 2002 28 12 1756 1760 10.1007/s00134-002- 1520-2 2-s2.0-0036448575 (Pubitemid 35446272)
    • (2002) Intensive Care Medicine , vol.28 , Issue.12 , pp. 1756-1760
    • Prin, S.1    Chergui, K.2    Augarde, R.3    Page, B.4    Jardin, F.5    Vieillard-Baron, A.6
  • 71
    • 0030896388 scopus 로고    scopus 로고
    • Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation
    • Hurni J., Feihl F., Lazor R., Leuenberger P., Perret C., Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 1997 111 3 686 691 10.1378/chest.111.3.686 2-s2.0-0030896388 (Pubitemid 27132947)
    • (1997) Chest , vol.111 , Issue.3 , pp. 686-691
    • Hurni, J.-M.1    Feihl, F.2    Lazor, R.3    Leuenberger, P.4    Perret, C.5
  • 72
    • 0029848008 scopus 로고    scopus 로고
    • Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation
    • Le Bourdellès G., Mier L., Fiquet B., Djedaïni K., Saumon G., Coste F., Dreyfuss D., Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest 1996 110 5 1294 1298 10.1378/chest.110.5.1294 2-s2.0-0029848008 (Pubitemid 26380489)
    • (1996) Chest , vol.110 , Issue.5 , pp. 1294-1298
    • Le Bourdelles, G.1    Mier, L.2    Fiquet, B.3    Djedaini, K.4    Saumon, G.5    Coste, F.6    Dreyfuss, D.7
  • 73
    • 0037986378 scopus 로고    scopus 로고
    • Mechanical effects of airway humidification devices in difficult to wean patients
    • DOI 10.1097/01.CCM.0000063284.92122.0E
    • Girault C., Breton L., Richard J., Tamion F., Vandelet P., Aboab J., Leroy J., Bonmarchand G., Mechanical effects of airway humidification devices in difficult to wean patients. Critical Care Medicine 2003 31 5 1306 1311 10.1097/01.CCM.0000063284.92122.0E 2-s2.0-0037986378 (Pubitemid 36583836)
    • (2003) Critical Care Medicine , vol.31 , Issue.5 , pp. 1306-1311
    • Girault, C.1    Breton, L.2    Richard, J.-C.3    Tamion, F.4    Vandelet, P.5    Aboab, J.6    Leroy, J.7    Bonmarchand, G.8
  • 74
    • 0030975466 scopus 로고    scopus 로고
    • Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients
    • DOI 10.1007/s001340050347
    • Iotti G. A., Olivei M. C., Palo A., Galbusera C., Veronesi R., Comelli A., Brunner J. X., Braschi A., Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients. Intensive Care Medicine 1997 23 4 399 405 10.1007/s001340050347 2-s2.0-0030975466 (Pubitemid 27196968)
    • (1997) Intensive Care Medicine , vol.23 , Issue.4 , pp. 399-405
    • Iotti, G.A.1    Olivei, M.C.2    Palo, A.3    Galbusera, C.4    Veronesi, R.5    Comelli, A.6    Brunner, J.X.7    Braschi, A.8
  • 75
    • 0032832851 scopus 로고    scopus 로고
    • Mechanical effects of heat-moisture exchangers in ventilated patients
    • DOI 10.1186/cc361
    • Iotti G. A., Olivei M. C., Braschi A., Mechanical effects of heat-moisture exchangers in ventilated patients. Critical Care 1999 3 5 R77 R82 10.1186/cc361 2-s2.0-0032832851 (Pubitemid 29488974)
    • (1999) Critical Care , vol.3 , Issue.5
    • Iotti, G.A.1    Olivei, M.C.2    Braschi, A.3
  • 76
    • 0032507210 scopus 로고    scopus 로고
    • Influence of airway management on ventilator-associated pneumonia: Evidence from randomized trials
    • DOI 10.1001/jama.279.10.781
    • Cook D., de Jonghe B., Brochard L., Brun-Buisson C., Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. The Journal of the American Medical Association 1998 279 10 781 787 10.1001/jama.279.10.781 2-s2.0-0032507210 (Pubitemid 28115005)
    • (1998) Journal of the American Medical Association , vol.279 , Issue.10 , pp. 781-787
    • Cook, D.1    De Jonghe, B.2    Brochard, L.3    Brun-Buisson, C.4
  • 77
    • 0030879788 scopus 로고    scopus 로고
    • A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: Rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
    • Kirton O. C., DeHaven B., Morgan J., Morejon O., Civetta J., A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 1997 112 4 1055 1059 10.1378/chest.112.4. 1055 2-s2.0-0030879788 (Pubitemid 27446329)
    • (1997) Chest , vol.112 , Issue.4 , pp. 1055-1059
    • Kirton, O.C.1    DeHaven, B.2    Morgan, J.3    Morejon, O.4    Civetta, J.5
  • 78
    • 1542394258 scopus 로고    scopus 로고
    • Care of the ventilator circuit and its relation to ventilator-associated pneumonia
    • 2-s2.0-1542394258
    • Hess D. R., Kallstrom T. J., Mottram C. D., Myers T. R., Sorenson H. M., Vines D. L., Care of the ventilator circuit and its relation to ventilator-associated pneumonia. Respiratory Care 2003 48 9 869 879 2-s2.0-1542394258
    • (2003) Respiratory Care , vol.48 , Issue.9 , pp. 869-879
    • Hess, D.R.1    Kallstrom, T.J.2    Mottram, C.D.3    Myers, T.R.4    Sorenson, H.M.5    Vines, D.L.6
  • 79
    • 36448976258 scopus 로고    scopus 로고
    • Impact of passive humidification on clinical outcomes of mechanically ventilated patients: A meta-analysis of randomized controlled trials
    • DOI 10.1097/01.CCM.0000295302.67973.9A
    • Siempos I. I., Vardakas K. Z., Kopterides P., Falagas M. E., Impact of passive humidification on clinical outcomes of mechanically ventilated patients: a meta-analysis of randomized controlled trials. Critical Care Medicine 2007 35 12 2843 2851 10.1097/01.CCM.0000295302.67973.9A 2-s2.0-36448976258 (Pubitemid 350175784)
    • (2007) Critical Care Medicine , vol.35 , Issue.12 , pp. 2843-2851
    • Siempos, I.I.1    Vardakas, K.Z.2    Kopterides, P.3    Falagas, M.E.4
  • 81
    • 1642525257 scopus 로고    scopus 로고
    • Guidelines for preventing health-care - Associated pneumonia, 2003: Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee
    • 2-s2.0-1642525257
    • Tablan O. C., Anderson L. J., Besser R., Bridges C., Hajjeh R., Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. Morbidity and Mortality Weekly Report: Recommendations and Reports 2004 53 RR-3 1 36 2-s2.0-1642525257
    • (2004) Morbidity and Mortality Weekly Report: Recommendations and Reports , vol.53 , Issue.RR-3 , pp. 1-36
    • Tablan, O.C.1    Anderson, L.J.2    Besser, R.3    Bridges, C.4    Hajjeh, R.5
  • 82
    • 13644269309 scopus 로고    scopus 로고
    • Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia
    • DOI 10.1164/rccm.200405-644ST
    • American Thoracic Society, Infectious Diseases Society of America, Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia. American Journal of Respiratory and Critical Care Medicine 2005 171 4 388 416 10.1164/rccm.200405- 644ST (Pubitemid 40227463)
    • (2005) American Journal of Respiratory and Critical Care Medicine , vol.171 , Issue.4 , pp. 388-416
  • 83
    • 58549097311 scopus 로고    scopus 로고
    • Defining, treating and preventing hospital acquired pneumonia: European perspective
    • 10.1007/s00134-008-1336-9 2-s2.0-58549097311
    • Torres A., Ewig S., Lode H., Carlet J., Defining, treating and preventing hospital acquired pneumonia: European perspective. Intensive Care Medicine 2009 35 1 9 29 10.1007/s00134-008-1336-9 2-s2.0-58549097311
    • (2009) Intensive Care Medicine , vol.35 , Issue.1 , pp. 9-29
    • Torres, A.1    Ewig, S.2    Lode, H.3    Carlet, J.4
  • 84
    • 40849130948 scopus 로고    scopus 로고
    • Comprehensive evidence-based clinical practice guidelines for ventilator-associated pneumonia: Prevention
    • DOI 10.1016/j.jcrc.2007.11.014, PII S0883944108000051
    • Muscedere J., Dodek P., Keenan S., Fowler R., Cook D., Heyland D., Comprehensive evidence-based clinical practice guidelines for ventilator-associated pneumonia: prevention. Journal of Critical Care 2008 23 1 126 137 10.1016/j.jcrc.2007.11.014 2-s2.0-40849130948 (Pubitemid 351400352)
    • (2008) Journal of Critical Care , vol.23 , Issue.1 , pp. 126-137
    • Muscedere, J.1    Dodek, P.2    Keenan, S.3    Fowler, R.4    Cook, D.5    Heyland, D.6
  • 85
    • 0036284869 scopus 로고    scopus 로고
    • Physicians' attitude to use heat and moisture exchangers or heated humidifiers: A Franco-Canadian survey
    • DOI 10.1007/s00134-002-1285-7
    • Ricard J., Cook D., Griffith L., Brochard L., Dreyfuss D., Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey. Intensive Care Medicine 2002 28 6 719 725 10.1007/s00134-002-1285-7 2-s2.0-0036284869 (Pubitemid 34639484)
    • (2002) Intensive Care Medicine , vol.28 , Issue.6 , pp. 719-725
    • Ricard, J.-D.1    Cook, D.2    Griffith, L.3    Brochard, L.4    Dreyfuss, D.5
  • 86
    • 77952478864 scopus 로고    scopus 로고
    • Heated humidification versus heat and moisture exchangers for ventilated adults and children
    • CD004711 2-s2.0-77952478864 10.1002/14651858.CD004711.pub2
    • Kelly M., Gillies D., Todd D. A., Lockwood C., Heated humidification versus heat and moisture exchangers for ventilated adults and children. The Cochrane Database of Systematic Reviews 2010 4 CD004711 2-s2.0-77952478864 10.1002/14651858.CD004711.pub2
    • (2010) The Cochrane Database of Systematic Reviews , Issue.4
    • Kelly, M.1    Gillies, D.2    Todd, D.A.3    Lockwood, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.