-
1
-
-
0006253247
-
Effect of dry anaesthetic gases on the respiratory mucus membrane
-
Burton JDK. Effect of dry anaesthetic gases on the respiratory mucus membrane. Lancet 1962; 1:235-238
-
(1962)
Lancet
, vol.1
, pp. 235-238
-
-
Burton, J.D.K.1
-
2
-
-
36448995303
-
Humidification
-
Tobin M, ed, New York, NY: McGraw-Hill
-
Ricard JD. Humidification. In: Tobin M, ed. Mechanical ventilation. New York, NY: McGraw-Hill, 2006; 1109-1120
-
(2006)
Mechanical ventilation
, pp. 1109-1120
-
-
Ricard, J.D.1
-
3
-
-
0036284869
-
Physicians' attitude to use heat and moisture exchangers or heated humidifiers: A Franco-Canadian survey
-
Ricard JD, Cook D, Griffith L, et al. Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey. Intensive Care Med 2002; 28:719-725
-
(2002)
Intensive Care Med
, vol.28
, pp. 719-725
-
-
Ricard, J.D.1
Cook, D.2
Griffith, L.3
-
4
-
-
60249086838
-
Weaning critically ill adults from invasive mechanical ventilation: A national survey [abstract]
-
Burns KEA, Lellouche F, Loisel F, et al. Weaning critically ill adults from invasive mechanical ventilation: a national survey [abstract]. Am J Respir Crit Care Med 2007; 175:A963
-
(2007)
Am J Respir Crit Care Med
, vol.175
-
-
Burns, K.E.A.1
Lellouche, F.2
Loisel, F.3
-
5
-
-
0037350223
-
Heat and moisture exchangers in mechanically ventilated intensive care unit patients: A plea for an independent assessment of their performance
-
Thiery G, Boyer A, Pigne E, et al. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance. Crit Care Med 2003; 31:699-704
-
(2003)
Crit Care Med
, vol.31
, pp. 699-704
-
-
Thiery, G.1
Boyer, A.2
Pigne, E.3
-
6
-
-
0023907089
-
Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit
-
Cohen IL, Weinberg PF, Fein IA, et al. Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med 1988; 16:277-279
-
(1988)
Crit Care Med
, vol.16
, pp. 277-279
-
-
Cohen, I.L.1
Weinberg, P.F.2
Fein, I.A.3
-
7
-
-
0025015270
-
Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
-
Martin C, Perrin G, Gevaudan MJ, et al. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 1990; 97:144-149
-
(1990)
Chest
, vol.97
, pp. 144-149
-
-
Martin, C.1
Perrin, G.2
Gevaudan, M.J.3
-
8
-
-
0025761055
-
Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation: A prospective randomized study
-
Misset B, Escudier B, Rivara D, et al. Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation: a prospective randomized study. Chest 1991; 100:160-163
-
(1991)
Chest
, vol.100
, pp. 160-163
-
-
Misset, B.1
Escudier, B.2
Rivara, D.3
-
9
-
-
0026611461
-
Comparison of hydrophobic heat and moisture exchanger with heated humidifier during prolonged mechanical ventilation
-
Roustan JP, Kienlen J, Aubas P, et al. Comparison of hydrophobic heat and moisture exchanger with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 1992; 18:97-100
-
(1992)
Intensive Care Med
, vol.18
, pp. 97-100
-
-
Roustan, J.P.1
Kienlen, J.2
Aubas, P.3
-
10
-
-
0030443959
-
Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices
-
Villafane MC, Cinnella G, Lofaso F, et al. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices. Anesthesiology 1996; 85:1341-1349
-
(1996)
Anesthesiology
, vol.85
, pp. 1341-1349
-
-
Villafane, M.C.1
Cinnella, G.2
Lofaso, F.3
-
11
-
-
0029760658
-
Evaluation of 21 passive humidifiers according to the ISO 9360 standard: Moisture output, dead space, and flow resistance
-
Branson R, Davis J. Evaluation of 21 passive humidifiers according to the ISO 9360 standard: moisture output, dead space, and flow resistance. Respir Care 1996; 41:736-743
-
(1996)
Respir Care
, vol.41
, pp. 736-743
-
-
Branson, R.1
Davis, J.2
-
12
-
-
0001963439
-
The efficiency of twelve heat and moisture exchangers: An in vitro evaluation
-
Cigada M, Elena A, Solca M, et al. The efficiency of twelve heat and moisture exchangers: an in vitro evaluation. Int Care World 1990; 7:98-101
-
(1990)
Int Care World
, vol.7
, pp. 98-101
-
-
Cigada, M.1
Elena, A.2
Solca, M.3
-
13
-
-
0014107554
-
Humidity in anesthesiology: III. Heat and moisture patterns in the respiratory tract during anesthesia with the semi-closed system
-
Dery R. Humidity in anesthesiology: III. Heat and moisture patterns in the respiratory tract during anesthesia with the semi-closed system. Can Anaesth Soc J 1967; 14:287-298
-
(1967)
Can Anaesth Soc J
, vol.14
, pp. 287-298
-
-
Dery, R.1
-
14
-
-
0015880049
-
The evolution of heat and moisture in the respiratory tract during anesthesia with a nonrebreathing system
-
Dery R. The evolution of heat and moisture in the respiratory tract during anesthesia with a nonrebreathing system. Can Anaesth Soc J 1973; 20:296-309
-
(1973)
Can Anaesth Soc J
, vol.20
, pp. 296-309
-
-
Dery, R.1
-
15
-
-
33745458492
-
Under-humidification and over-humidification during moderate induced hypothermia with usual devices
-
Lellouche F, Qader S, Taille S, et al. Under-humidification and over-humidification during moderate induced hypothermia with usual devices. Intensive Care Med 2006; 32:1014-1021
-
(2006)
Intensive Care Med
, vol.32
, pp. 1014-1021
-
-
Lellouche, F.1
Qader, S.2
Taille, S.3
-
16
-
-
0026649096
-
An evaluation of the heat and moisture exchange performance of four ventilator circuit filters
-
Jackson C, Webb AR. An evaluation of the heat and moisture exchange performance of four ventilator circuit filters. Intensive Care Med 1992; 18:264-268
-
(1992)
Intensive Care Med
, vol.18
, pp. 264-268
-
-
Jackson, C.1
Webb, A.R.2
-
17
-
-
0033968236
-
Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week
-
Ricard JD, Le Miere E, Markowicz P, et al. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 2000; 161:104-109
-
(2000)
Am J Respir Crit Care Med
, vol.161
, pp. 104-109
-
-
Ricard, J.D.1
Le Miere, E.2
Markowicz, P.3
-
18
-
-
8444237099
-
Influence of ambient air and ventilator output temperature on performances of heated-wire humidifiers
-
Lellouche L, Taille S, Maggiore M, et al. Influence of ambient air and ventilator output temperature on performances of heated-wire humidifiers. Am J Respir Crit Care Med 2004; 170:1073-1079
-
(2004)
Am J Respir Crit Care Med
, vol.170
, pp. 1073-1079
-
-
Lellouche, L.1
Taille, S.2
Maggiore, M.3
-
19
-
-
0033040999
-
Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill
-
Ricard JD, Markowicz P, Djedaini K, et al. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. Chest 1999; 115:1646-1652
-
(1999)
Chest
, vol.115
, pp. 1646-1652
-
-
Ricard, J.D.1
Markowicz, P.2
Djedaini, K.3
-
20
-
-
0034754229
-
Factors associated with blocked tracheal tubes
-
Kapadia FN. Factors associated with blocked tracheal tubes. Intensive Care Med 2001; 27:1679-1681
-
(2001)
Intensive Care Med
, vol.27
, pp. 1679-1681
-
-
Kapadia, F.N.1
-
21
-
-
0021237635
-
The Pall Ultipor breathing circuit filter: An efficient heat and moisture exchanger
-
Chalon J, Markham JP, Ali MM, et al. The Pall Ultipor breathing circuit filter: an efficient heat and moisture exchanger. Anesth Analg 1984; 63:566-570
-
(1984)
Anesth Analg
, vol.63
, pp. 566-570
-
-
Chalon, J.1
Markham, J.P.2
Ali, M.M.3
-
22
-
-
0025127771
-
Performance evaluation of six heat and moisture exchangers according to the Draft International Standard (ISO/DIS 9360)
-
Eckerbom B, Lindholm CE. Performance evaluation of six heat and moisture exchangers according to the Draft International Standard (ISO/DIS 9360). Acta Anaesthesiol Scand 1990; 34:404-409
-
(1990)
Acta Anaesthesiol Scand
, vol.34
, pp. 404-409
-
-
Eckerbom, B.1
Lindholm, C.E.2
-
23
-
-
0018638686
-
The hygroscopic condenser humidifier: A new device for general use in anaesthesia and intensive care
-
Gedeon A, Mebius C. The hygroscopic condenser humidifier: a new device for general use in anaesthesia and intensive care. Anaesthesia 1979; 34:1043-1047
-
(1979)
Anaesthesia
, vol.34
, pp. 1043-1047
-
-
Gedeon, A.1
Mebius, C.2
-
24
-
-
0020644519
-
A comparative evaluation of disposable humidifiers
-
Mebius C. A comparative evaluation of disposable humidifiers. Acta Anaesthesiol Scand 1983; 27:403-409
-
(1983)
Acta Anaesthesiol Scand
, vol.27
, pp. 403-409
-
-
Mebius, C.1
-
25
-
-
0026710032
-
Heat and moisture exchangers with bacterial filters: A laboratory evaluation
-
Mebius C. Heat and moisture exchangers with bacterial filters: a laboratory evaluation. Acta Anaesthesiol Scand 1992; 36:572-576
-
(1992)
Acta Anaesthesiol Scand
, vol.36
, pp. 572-576
-
-
Mebius, C.1
-
26
-
-
0022368521
-
Moisture-conserving efficiency of condenser humidifiers
-
Ogino M, Kopotic R, Mannino FL. Moisture-conserving efficiency of condenser humidifiers. Anaesthesia 1985; 40: 990-995
-
(1985)
Anaesthesia
, vol.40
, pp. 990-995
-
-
Ogino, M.1
Kopotic, R.2
Mannino, F.L.3
-
27
-
-
0022458018
-
A comparison of five heat and moisture exchangers
-
Shelly M, Bethune BW, Latimer RD. A comparison of five heat and moisture exchangers. Anaesthesia 1986; 41:527-532
-
(1986)
Anaesthesia
, vol.41
, pp. 527-532
-
-
Shelly, M.1
Bethune, B.W.2
Latimer, R.D.3
-
28
-
-
0023258869
-
An evaluation of six disposable heat and moisture exchangers
-
Turtle MJ, Ilsley AH, Rutten AJ, et al. An evaluation of six disposable heat and moisture exchangers. Anaesth Intensive Care 1987; 15:317-322
-
(1987)
Anaesth Intensive Care
, vol.15
, pp. 317-322
-
-
Turtle, M.J.1
Ilsley, A.H.2
Rutten, A.J.3
-
29
-
-
0031920448
-
A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings
-
Unal N, Kanhai JK, Buijk SL, et al. A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings. Intensive Care Med 1998; 24:138-146
-
(1998)
Intensive Care Med
, vol.24
, pp. 138-146
-
-
Unal, N.1
Kanhai, J.K.2
Buijk, S.L.3
-
30
-
-
0028916648
-
An experimental set-up to test heat-moisture exchangers
-
Unal N, Pompe JC, Holland WP, et al. An experimental set-up to test heat-moisture exchangers. Intensive Care Med 1995; 21:142-148
-
(1995)
Intensive Care Med
, vol.21
, pp. 142-148
-
-
Unal, N.1
Pompe, J.C.2
Holland, W.P.3
-
31
-
-
0017011407
-
A comparative study of condenser humidifiers
-
Walker AK, Bethune DW. A comparative study of condenser humidifiers. Anaesthesia 1976; 31:1086-1093
-
(1976)
Anaesthesia
, vol.31
, pp. 1086-1093
-
-
Walker, A.K.1
Bethune, D.W.2
-
32
-
-
0001530809
-
Laboratory evaluation of of moisture output of seven airway heat and moisture exchangers
-
Branson R, Hurst JM. Laboratory evaluation of of moisture output of seven airway heat and moisture exchangers. Respir Care 1987; 32:741-747
-
(1987)
Respir Care
, vol.32
, pp. 741-747
-
-
Branson, R.1
Hurst, J.M.2
-
33
-
-
0020568546
-
A laboratory investigation of six artificial nose for use during endotracheal anesthesia
-
Weeks DB, Ramsay FM. A laboratory investigation of six artificial nose for use during endotracheal anesthesia. Anesth Analg 1981; 62:758-763
-
(1981)
Anesth Analg
, vol.62
, pp. 758-763
-
-
Weeks, D.B.1
Ramsay, F.M.2
-
34
-
-
0028889953
-
Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices
-
Vanderbroucke-Grauls CM, Teeuw KB, Ballemans K, et al. Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices. J Hosp Infect 1995; 29:45-56
-
(1995)
J Hosp Infect
, vol.29
, pp. 45-56
-
-
Vanderbroucke-Grauls, C.M.1
Teeuw, K.B.2
Ballemans, K.3
-
35
-
-
85037406249
-
-
International Organization of Standards, ISO
-
International Organization of Standards. Humidifiers for medical use. ISO 1988; 60:14
-
(1988)
Humidifiers for medical use
, vol.60
, pp. 14
-
-
-
36
-
-
0026907566
-
humidification during mechanical ventilation; American Association for Respiratory Care
-
AARC clinical practice guideline
-
AARC clinical practice guideline: humidification during mechanical ventilation; American Association for Respiratory Care. Respir Care 1992; 37:887-890
-
(1992)
Respir Care
, vol.37
, pp. 887-890
-
-
-
37
-
-
0026446257
-
Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min
-
Martin C, Papazian L, Perrin G, et al. Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min. Chest 1992; 102:1347-1350
-
(1992)
Chest
, vol.102
, pp. 1347-1350
-
-
Martin, C.1
Papazian, L.2
Perrin, G.3
-
38
-
-
33644604269
-
Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia
-
Boots RJ, George N, Faoagali JL, et al. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia. Crit Care Med 2006; 34: 687-693
-
(2006)
Crit Care Med
, vol.34
, pp. 687-693
-
-
Boots, R.J.1
George, N.2
Faoagali, J.L.3
-
39
-
-
0030874818
-
Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
-
Boots RJ, Howe S, George N, et al. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 1997; 25:1707-1712
-
(1997)
Crit Care Med
, vol.25
, pp. 1707-1712
-
-
Boots, R.J.1
Howe, S.2
George, N.3
-
40
-
-
0028968722
-
Mechanical ventilation with heated humidifiers or heat and moisture exchangers: Effects on patient colonization and incidence of nosocomial pneumonia
-
Dreyfuss D, Djedaini K, Gros I, et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995; 151:986-992
-
(1995)
Am J Respir Crit Care Med
, vol.151
, pp. 986-992
-
-
Dreyfuss, D.1
Djedaini, K.2
Gros, I.3
-
41
-
-
0030896388
-
Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation
-
Hurni JM, Feihl F, Lazor R, et al. Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 1997; 111:686-691
-
(1997)
Chest
, vol.111
, pp. 686-691
-
-
Hurni, J.M.1
Feihl, F.2
Lazor, R.3
-
42
-
-
30444447238
-
Impact of humid-ification systems on ventilator-associated pneumonia: A randomized multicenter trial
-
Lacherade JC, Auburtin M, Cerf C, et al. Impact of humid-ification systems on ventilator-associated pneumonia: a randomized multicenter trial. Am J Respir Crit Care Med 2005; 172:1276-1282
-
(2005)
Am J Respir Crit Care Med
, vol.172
, pp. 1276-1282
-
-
Lacherade, J.C.1
Auburtin, M.2
Cerf, C.3
-
43
-
-
0031936853
-
Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours
-
Thomachot L, Vialet R, Viguier JM, et al. Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours. Crit Care Med 1998; 26:477-481
-
(1998)
Crit Care Med
, vol.26
, pp. 477-481
-
-
Thomachot, L.1
Vialet, R.2
Viguier, J.M.3
-
44
-
-
0034103469
-
Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: A prospective, randomized study
-
Markowicz P, Ricard JD, Dreyfuss D, et al. Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Crit Care Med 2000; 28:665-671
-
(2000)
Crit Care Med
, vol.28
, pp. 665-671
-
-
Markowicz, P.1
Ricard, J.D.2
Dreyfuss, D.3
-
45
-
-
0030879788
-
A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: Rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
-
Kirton OC, DeHaven B, Morgan J, et al. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 1997; 112:1055-1059
-
(1997)
Chest
, vol.112
, pp. 1055-1059
-
-
Kirton, O.C.1
DeHaven, B.2
Morgan, J.3
-
46
-
-
0036155170
-
Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days
-
Thomachot L, Leone M, Razzouk K, et al. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 2002; 30:232-237
-
(2002)
Crit Care Med
, vol.30
, pp. 232-237
-
-
Thomachot, L.1
Leone, M.2
Razzouk, K.3
-
47
-
-
0033030246
-
Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
-
Thomachot L, Vialet R, Arnaud S, et al. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 1999; 27:923-928
-
(1999)
Crit Care Med
, vol.27
, pp. 923-928
-
-
Thomachot, L.1
Vialet, R.2
Arnaud, S.3
-
48
-
-
0031733848
-
Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosoco-mial pneumonia
-
Thomachot L, Viviand X, Arnaud S, et al. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosoco-mial pneumonia. Chest 1998; 114:1383-1389
-
(1998)
Chest
, vol.114
, pp. 1383-1389
-
-
Thomachot, L.1
Viviand, X.2
Arnaud, S.3
-
49
-
-
0029061970
-
Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min
-
Martin C, Thomachot L, Quinio B, et al. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Chest 1995; 107:1411-1415
-
(1995)
Chest
, vol.107
, pp. 1411-1415
-
-
Martin, C.1
Thomachot, L.2
Quinio, B.3
-
50
-
-
33745474016
-
Impact of ambient air temperature on a new active HME and on standard HMES: Bench evaluation
-
Lellouche F, Qader S, Taillé S, et al. Impact of ambient air temperature on a new active HME and on standard HMES: bench evaluation. Intensive Care Med 2003; 29:S169
-
(2003)
Intensive Care Med
, vol.29
-
-
Lellouche, F.1
Qader, S.2
Taillé, S.3
-
51
-
-
0028073939
-
Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min
-
Martin C, Papazian L, Perrin G, et al. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min. Crit Care Med 1994; 22:1871-1876
-
(1994)
Crit Care Med
, vol.22
, pp. 1871-1876
-
-
Martin, C.1
Papazian, L.2
Perrin, G.3
-
52
-
-
85031350779
-
-
Anesthetic and respiratory equipment: heat and moisture exchangers for use in humidifying gases in humans, 1st ed; ISO International Standard 9360. Geneva, Switzerland: International Organization for Standardization, 1992
-
Anesthetic and respiratory equipment: heat and moisture exchangers for use in humidifying gases in humans, 1st ed; ISO International Standard 9360. Geneva, Switzerland: International Organization for Standardization, 1992
-
-
-
-
53
-
-
0027451823
-
Humidification in the intensive care unit: Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier
-
Branson RD, Davis K, Campbell RS, et al. Humidification in the intensive care unit: prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 1993; 104:1800-1805
-
(1993)
Chest
, vol.104
, pp. 1800-1805
-
-
Branson, R.D.1
Davis, K.2
Campbell, R.S.3
-
54
-
-
1642303038
-
Long-term effects of different humidification systems on endotracheal tube patency: Evaluation by the accoustic reflection method
-
Jaber S, Pigeot J, Fodil R, et al. Long-term effects of different humidification systems on endotracheal tube patency: evaluation by the accoustic reflection method. Anesthesiology 2004; 100:782-788
-
(2004)
Anesthesiology
, vol.100
, pp. 782-788
-
-
Jaber, S.1
Pigeot, J.2
Fodil, R.3
-
55
-
-
0031888824
-
A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
-
Kollef MH, Shapiro SD, Boyd V, et al. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 1998; 113:759-767
-
(1998)
Chest
, vol.113
, pp. 759-767
-
-
Kollef, M.H.1
Shapiro, S.D.2
Boyd, V.3
-
56
-
-
0032705361
-
Changing a hydropho-bic heat and moisture exchanger after 48 hours rather than 24 hours: A clinical and microbiological evaluation
-
Boisson C, Viviand X, Arnaud S, et al. Changing a hydropho-bic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation. Intensive Care Med 1999; 25:1237-1243
-
(1999)
Intensive Care Med
, vol.25
, pp. 1237-1243
-
-
Boisson, C.1
Viviand, X.2
Arnaud, S.3
|