-
1
-
-
85136437461
-
-
Cook D, De Jonghe B, Brochard L, Brun-Buisson C. Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 1998;279(10):781-787. Erratum in: JAMA 1999;281(22):2089
-
Cook D, De Jonghe B, Brochard L, Brun-Buisson C. Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 1998;279(10):781-787. Erratum in: JAMA 1999;281(22):2089
-
-
-
-
2
-
-
0032531113
-
Incidence of and risk factors for ventilator-associated pneumonia in critically ill patients
-
Cook DJ, Walter SD, Cook RJ, Griffith LE, Guyatt GH, Leasa D, et al. Incidence of and risk factors for ventilator-associated pneumonia in critically ill patients. Ann Intern Med 1998;129(6):433-440.
-
(1998)
Ann Intern Med
, vol.129
, Issue.6
, pp. 433-440
-
-
Cook, D.J.1
Walter, S.D.2
Cook, R.J.3
Griffith, L.E.4
Guyatt, G.H.5
Leasa, D.6
-
3
-
-
0033782961
-
Ventilator circuit and secretion management strategies: A Franco-Canadian survey
-
Cook D, Ricard JD, Reeve B, Randall J, Wigg M, Brochard L, Dreyfuss D. Ventilator circuit and secretion management strategies: a Franco-Canadian survey. Crit Care Med 2000;28(10):3547-3554.
-
(2000)
Crit Care Med
, vol.28
, Issue.10
, pp. 3547-3554
-
-
Cook, D.1
Ricard, J.D.2
Reeve, B.3
Randall, J.4
Wigg, M.5
Brochard, L.6
Dreyfuss, D.7
-
4
-
-
0342598856
-
The potential role of inhalation therapy equipment in nosocomial pulmonary infection
-
Reinarz JA, Pierce AK, Mays BB, Sanford JP. The potential role of inhalation therapy equipment in nosocomial pulmonary infection. J Clin Invest 1965;44:831-839.
-
(1965)
J Clin Invest
, vol.44
, pp. 831-839
-
-
Reinarz, J.A.1
Pierce, A.K.2
Mays, B.B.3
Sanford, J.P.4
-
5
-
-
0013897384
-
Nebulization equipment: A potential source of infection in gram-negative pneumonias
-
Edmondson EB, Reinarz JA, Pierce AK, Sanford JP. Nebulization equipment: a potential source of infection in gram-negative pneumonias. Am J Dis Child 1966;111(4):357-360.
-
(1966)
Am J Dis Child
, vol.111
, Issue.4
, pp. 357-360
-
-
Edmondson, E.B.1
Reinarz, J.A.2
Pierce, A.K.3
Sanford, J.P.4
-
6
-
-
0020083698
-
Contamination of mechanical ventilators with tubing changes every 24 or 48 hours
-
Craven DE, Connolly MG Jr, Lichtenberg DA, Primeau PJ, McCabe WR. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med 1982;306(25):1505-1509.
-
(1982)
N Engl J Med
, vol.306
, Issue.25
, pp. 1505-1509
-
-
Craven, D.E.1
Connolly Jr, M.G.2
Lichtenberg, D.A.3
Primeau, P.J.4
McCabe, W.R.5
-
7
-
-
0022622761
-
Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation
-
Craven DE, Kunches LM, Kilinsky V, Lichtenberg DA, Make BJ, McCabe WR. Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation. Am Rev Respir Dis 1986;133(5):792-796.
-
(1986)
Am Rev Respir Dis
, vol.133
, Issue.5
, pp. 792-796
-
-
Craven, D.E.1
Kunches, L.M.2
Kilinsky, V.3
Lichtenberg, D.A.4
Make, B.J.5
McCabe, W.R.6
-
8
-
-
0025980586
-
Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change
-
Dreyfuss D, Djedaini K, Weber P, Brun P, Lanore JJ, Rahmani J, et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis 1991;143(4 Pt 1):738-743.
-
(1991)
Am Rev Respir Dis
, vol.143
, Issue.4 PART 1
, pp. 738-743
-
-
Dreyfuss, D.1
Djedaini, K.2
Weber, P.3
Brun, P.4
Lanore, J.J.5
Rahmani, J.6
-
9
-
-
0029090682
-
Mechanical ventilation with or without 7-day circuit changes. A randomized, controlled trial
-
Kollef MH, Shapiro SD, Fraser VJ, Silver P, Murphy DM, Trovillion E, et al. Mechanical ventilation with or without 7-day circuit changes. A randomized, controlled trial. Ann Intern Med 1995;123(3):168-174.
-
(1995)
Ann Intern Med
, vol.123
, Issue.3
, pp. 168-174
-
-
Kollef, M.H.1
Shapiro, S.D.2
Fraser, V.J.3
Silver, P.4
Murphy, D.M.5
Trovillion, E.6
-
10
-
-
0029692820
-
Prospective, randomized study of ventilator-associated pneumonia in patients with one versus 3 ventilator circuit changes per week
-
Long MN, Wickstrom G, Grimes A, Benton CF, Belcher B, Stamm AM. Prospective, randomized study of ventilator-associated pneumonia in patients with one versus 3 ventilator circuit changes per week. Infect Control Hosp Epidemiol 1996;17(1):14-19.
-
(1996)
Infect Control Hosp Epidemiol
, vol.17
, Issue.1
, pp. 14-19
-
-
Long, M.N.1
Wickstrom, G.2
Grimes, A.3
Benton, C.F.4
Belcher, B.5
Stamm, A.M.6
-
11
-
-
0018161409
-
The relationship between frequency of ventilator circuit changes and infectious hazard
-
Lareau SC, Ryan KJ, Diener CF. The relationship between frequency of ventilator circuit changes and infectious hazard. Am Rev Respir Dis 1978;118(3):493-496.
-
(1978)
Am Rev Respir Dis
, vol.118
, Issue.3
, pp. 493-496
-
-
Lareau, S.C.1
Ryan, K.J.2
Diener, C.F.3
-
12
-
-
0028943271
-
Weekly ventilator circuit changes: A strategy to reduce costs without affecting pneumonia rates
-
Hess D, Burns E, Romagnoli D, Kacmarek RM. Weekly ventilator circuit changes: a strategy to reduce costs without affecting pneumonia rates. Anesthesiology 1995;82(4):903-911.
-
(1995)
Anesthesiology
, vol.82
, Issue.4
, pp. 903-911
-
-
Hess, D.1
Burns, E.2
Romagnoli, D.3
Kacmarek, R.M.4
-
13
-
-
0030016983
-
Incidence of ventilator-associated pneumonia (VAP) with 14-day circuit change in a subacute environment
-
Thompson RE. Incidence of ventilator-associated pneumonia (VAP) with 14-day circuit change in a subacute environment. Respir Care 1996;41(7):601-606.
-
(1996)
Respir Care
, vol.41
, Issue.7
, pp. 601-606
-
-
Thompson, R.E.1
-
14
-
-
0030971809
-
Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit
-
Kotilainen HR, Keroack MA. Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit. Am J Infect Control 1997;25(2):117-120.
-
(1997)
Am J Infect Control
, vol.25
, Issue.2
, pp. 117-120
-
-
Kotilainen, H.R.1
Keroack, M.A.2
-
15
-
-
0031932324
-
Extending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia
-
Fink JB, Krause SA, Barrett L, Schaaff D, Alex CG. Extending ventilator circuit change interval beyond 2 days reduces the likelihood of ventilator-associated pneumonia. Chest 1998;113(2):405-411.
-
(1998)
Chest
, vol.113
, Issue.2
, pp. 405-411
-
-
Fink, J.B.1
Krause, S.A.2
Barrett, L.3
Schaaff, D.4
Alex, C.G.5
-
16
-
-
0035462347
-
Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator-associated pneumonia in a Beijing hospital
-
Han JN, Liu YP, Ma S, Zhu YJ, Sui SH, Chen XJ et al. Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator-associated pneumonia in a Beijing hospital. Respir Care 2001;46(9):891-896.
-
(2001)
Respir Care
, vol.46
, Issue.9
, pp. 891-896
-
-
Han, J.N.1
Liu, Y.P.2
Ma, S.3
Zhu, Y.J.4
Sui, S.H.5
Chen, X.J.6
-
17
-
-
0034954103
-
Ventilator-associated pneumonia with circuit changes every 2 days versus every week
-
Lien TC, Lin MY, Chu CC, Kuo BI, Wang ED, Wang JH. Ventilator-associated pneumonia with circuit changes every 2 days versus every week. Zhonghua Yi Xue Za Zhi (Taipei) 2001;64(3):161-167.
-
(2001)
Zhonghua Yi Xue Za Zhi (Taipei)
, vol.64
, Issue.3
, pp. 161-167
-
-
Lien, T.C.1
Lin, M.Y.2
Chu, C.C.3
Kuo, B.I.4
Wang, E.D.5
Wang, J.H.6
-
18
-
-
0022527566
-
Bubbling humidifiers produce microaerosols which can carry bacteria
-
Rhame FS, Streifel A, McComb C, Boyle M. Bubbling humidifiers produce microaerosols which can carry bacteria. Infect Control 1986;7(8):403-407.
-
(1986)
Infect Control
, vol.7
, Issue.8
, pp. 403-407
-
-
Rhame, F.S.1
Streifel, A.2
McComb, C.3
Boyle, M.4
-
19
-
-
0028968062
-
The effects of circuit and humidifier type on contamination potential during mechanical ventilation: A laboratory study
-
Gilmour IJ, Boyle MJ, Streifel A, McComb RC. The effects of circuit and humidifier type on contamination potential during mechanical ventilation: a laboratory study. Am J Infect Control 1995;23(2):65-72.
-
(1995)
Am J Infect Control
, vol.23
, Issue.2
, pp. 65-72
-
-
Gilmour, I.J.1
Boyle, M.J.2
Streifel, A.3
McComb, R.C.4
-
20
-
-
0023237412
-
Bacterial colonization in humidifying cascade reservoirs after 24 and 48 hours of continuous mechanical ventilation
-
Goularte TA, Manning M, Craven DE. Bacterial colonization in humidifying cascade reservoirs after 24 and 48 hours of continuous mechanical ventilation. Infect Control 1987;8(5):200-203.
-
(1987)
Infect Control
, vol.8
, Issue.5
, pp. 200-203
-
-
Goularte, T.A.1
Manning, M.2
Craven, D.E.3
-
21
-
-
0029831013
-
Comparison of 3 humidification techniques during mechanical ventilation: Patient selection, cost, and infection considerations
-
Branson RD, Davis K Jr, Brown R, Rashkin M. Comparison of 3 humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 1996;41(9):809-816.
-
(1996)
Respir Care
, vol.41
, Issue.9
, pp. 809-816
-
-
Branson, R.D.1
Davis Jr, K.2
Brown, R.3
Rashkin, M.4
-
22
-
-
0021275019
-
Contaminated condensate in mechanical ventilator circuits: A risk factor for nosocomial pneumonia?
-
Craven DE, Goularte TA, Make BJ. Contaminated condensate in mechanical ventilator circuits: a risk factor for nosocomial pneumonia? Am Rev Respir Dis 1984;129(4):625-628.
-
(1984)
Am Rev Respir Dis
, vol.129
, Issue.4
, pp. 625-628
-
-
Craven, D.E.1
Goularte, T.A.2
Make, B.J.3
-
23
-
-
0033708565
-
Heat-and-moisture exchangers used with biweekly circuit tubing changes: Effect on costs and pneumonia rates
-
Salemi C, Padilla S, Canola T, Reynolds D. Heat-and-moisture exchangers used with biweekly circuit tubing changes: effect on costs and pneumonia rates. Infect Control Hosp Epidemiol 2000;21(11):737-739.
-
(2000)
Infect Control Hosp Epidemiol
, vol.21
, Issue.11
, pp. 737-739
-
-
Salemi, C.1
Padilla, S.2
Canola, T.3
Reynolds, D.4
-
24
-
-
0023936842
-
Influence of disposable ('Conchapak') and reusable humidifying systems on the incidence of ventilation pneumonia
-
Daschner F, Kappstein I, Schuster F, Scholz R, Bauer E, Joossens D, Just H. Influence of disposable ('Conchapak') and reusable humidifying systems on the incidence of ventilation pneumonia. J Hosp Infect 1988;11(2):161-168.
-
(1988)
J Hosp Infect
, vol.11
, Issue.2
, pp. 161-168
-
-
Daschner, F.1
Kappstein, I.2
Schuster, F.3
Scholz, R.4
Bauer, E.5
Joossens, D.6
Just, H.7
-
25
-
-
0032084680
-
Humidification in the intensive care unit
-
Branson RD, Campbell RS. Humidification in the intensive care unit. Respir Care Clin N Am 1998;4(2):305-320.
-
(1998)
Respir Care Clin N Am
, vol.4
, Issue.2
, pp. 305-320
-
-
Branson, R.D.1
Campbell, R.S.2
-
26
-
-
0023267534
-
Contamination control in long-term ventilation: A clinical study using a heat- and moisture-exchanging filter
-
Gallagher J, Strangeways JEM, Allt-Graham J. Contamination control in long-term ventilation: a clinical study using a heat- and moisture-exchanging filter. Anaesthesia 1987;42(5):476-481.
-
(1987)
Anaesthesia
, vol.42
, Issue.5
, pp. 476-481
-
-
Gallagher, J.1
Strangeways, J.E.M.2
Allt-Graham, J.3
-
27
-
-
0025272095
-
Bacterial contamination and frequency of changing ventilator circuitry
-
Cadwallader HL, Bradley CR, Ayliffe GAJ. Bacterial contamination and frequency of changing ventilator circuitry. J Hosp Infect 1990;15(1):65-72.
-
(1990)
J Hosp Infect
, vol.15
, Issue.1
, pp. 65-72
-
-
Cadwallader, H.L.1
Bradley, C.R.2
Ayliffe, G.A.J.3
-
28
-
-
0019170685
-
Do moisture exchangers prevent patient contamination of ventilators? A microbiological study comparing 2 different humidifying devices
-
Strange K, Bygdeman S. Do moisture exchangers prevent patient contamination of ventilators? A microbiological study comparing 2 different humidifying devices. Acta Anaesthesiol Scand 1980;24(6):487-490.
-
(1980)
Acta Anaesthesiol Scand
, vol.24
, Issue.6
, pp. 487-490
-
-
Strange, K.1
Bygdeman, S.2
-
29
-
-
0022531991
-
Lack of bacterial aerosols associated with heat and moisture exchangers
-
Saravolatz LD, Pohlod DJ, Conway W, Haberaecker W, Markowitz NP, Popovich J Jr. Lack of bacterial aerosols associated with heat and moisture exchangers. Am Rev Respir Dis 1986;134(2):214-216.
-
(1986)
Am Rev Respir Dis
, vol.134
, Issue.2
, pp. 214-216
-
-
Saravolatz, L.D.1
Pohlod, D.J.2
Conway, W.3
Haberaecker, W.4
Markowitz, N.P.5
Popovich Jr, J.6
-
30
-
-
0021647899
-
Moisture exchangers do not prevent patient contamination of ventilators: A microbiological study
-
Bygdeman S, von Euler C, Nystrom B. Moisture exchangers do not prevent patient contamination of ventilators: a microbiological study. Acta Anaesthesiol Scand 1984;28(6):591-594.
-
(1984)
Acta Anaesthesiol Scand
, vol.28
, Issue.6
, pp. 591-594
-
-
Bygdeman, S.1
von Euler, C.2
Nystrom, B.3
-
31
-
-
0031467808
-
How useful are microbial filters in respiratory apparatus?
-
Das I, Fraise AP. How useful are microbial filters in respiratory apparatus? J Hosp Infect 1997;37(4):263-272.
-
(1997)
J Hosp Infect
, vol.37
, Issue.4
, pp. 263-272
-
-
Das, I.1
Fraise, A.P.2
-
32
-
-
0025761055
-
Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation: A prospective randomized study
-
Misset B, Escudier B, Rivara D, Leclercq B, Nitenberg G. Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation: a prospective randomized study. Chest 1991;100(1):160-163.
-
(1991)
Chest
, vol.100
, Issue.1
, pp. 160-163
-
-
Misset, B.1
Escudier, B.2
Rivara, D.3
Leclercq, B.4
Nitenberg, G.5
-
33
-
-
0025015270
-
Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
-
Martin C, Perrin G, Gevaudan M, Saux P, Gouin F. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 1990;97(1):144-149.
-
(1990)
Chest
, vol.97
, Issue.1
, pp. 144-149
-
-
Martin, C.1
Perrin, G.2
Gevaudan, M.3
Saux, P.4
Gouin, F.5
-
34
-
-
0026611461
-
Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation
-
Roustan JP, Kienlen J, Aubas P, Aubas S, du Cailar J. Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 1992;18(2):97-100.
-
(1992)
Intensive Care Med
, vol.18
, Issue.2
, pp. 97-100
-
-
Roustan, J.P.1
Kienlen, J.2
Aubas, P.3
Aubas, S.4
du Cailar, J.5
-
35
-
-
0028968722
-
Mechanical ventilation with heated humidifiers or heat and moisture exchangers: Effects on patient colonization and incidence of nosocomial pneumonia
-
Dreyfuss D, Djedaini K, Gros I, Mier L, Le Bourdelles G, Cohen Y, et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995;151(4):986-992.
-
(1995)
Am J Respir Crit Care Med
, vol.151
, Issue.4
, pp. 986-992
-
-
Dreyfuss, D.1
Djedaini, K.2
Gros, I.3
Mier, L.4
Le Bourdelles, G.5
Cohen, Y.6
-
36
-
-
0030879788
-
A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: Rates of ventilator-associated early-onset (community-acquired) or late-onset (hospitalacquired) pneumonia and incidence of endotracheal tube occlusion
-
Kirton OC, DeHaven B, Morgan J, Morejon O, Civetta J. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospitalacquired) pneumonia and incidence of endotracheal tube occlusion. Chest 1977;112(4):1055-1059.
-
(1977)
Chest
, vol.112
, Issue.4
, pp. 1055-1059
-
-
Kirton, O.C.1
DeHaven, B.2
Morgan, J.3
Morejon, O.4
Civetta, J.5
-
37
-
-
0031888824
-
A randomized clinical trial comparing an extendeduse hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
-
Kollef MH, Shapiro SD, Boyd V, Silver P, Von Harz B, Trovillion E, Prentice D. A randomized clinical trial comparing an extendeduse hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 1998;113(3):759-767.
-
(1998)
Chest
, vol.113
, Issue.3
, pp. 759-767
-
-
Kollef, M.H.1
Shapiro, S.D.2
Boyd, V.3
Silver, P.4
Von Harz, B.5
Trovillion, E.6
Prentice, D.7
-
38
-
-
0031733848
-
Comparing 2 heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia
-
Thomachot L, Viviand X, Arnaud S, Boisson C, Martin CD. Comparing 2 heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 1998;114(5):1383-1389.
-
(1998)
Chest
, vol.114
, Issue.5
, pp. 1383-1389
-
-
Thomachot, L.1
Viviand, X.2
Arnaud, S.3
Boisson, C.4
Martin, C.D.5
-
39
-
-
0033030246
-
Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
-
Thomachot L, Vialet R, Arnaud S, Barberon B, Michel-Nguyen A, Martin C. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 1999;27(5):923-928.
-
(1999)
Crit Care Med
, vol.27
, Issue.5
, pp. 923-928
-
-
Thomachot, L.1
Vialet, R.2
Arnaud, S.3
Barberon, B.4
Michel-Nguyen, A.5
Martin, C.6
-
40
-
-
0029934198
-
Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure
-
Pelosi P, Solca M, Ravagnan I, Tubiolo D, Ferrario L, Gattinoni L. Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure. Crit Care Med 1996;24(7):1184-1188.
-
(1996)
Crit Care Med
, vol.24
, Issue.7
, pp. 1184-1188
-
-
Pelosi, P.1
Solca, M.2
Ravagnan, I.3
Tubiolo, D.4
Ferrario, L.5
Gattinoni, L.6
-
41
-
-
0029848008
-
Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation
-
Le Bourdelles G, Mier L, Fiquet B, Djedaini K, Saumon G, Coste F, Dreyfuss D. Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest 1996;110(5):1294-1298.
-
(1996)
Chest
, vol.110
, Issue.5
, pp. 1294-1298
-
-
Le Bourdelles, G.1
Mier, L.2
Fiquet, B.3
Djedaini, K.4
Saumon, G.5
Coste, F.6
Dreyfuss, D.7
-
42
-
-
0030896388
-
Safety of combined heat and moisture exchange filters in long-term mechanical ventilation
-
Hurni JM, Fiehl F, Lazor R, Leuenberger P, Perret C. Safety of combined heat and moisture exchange filters in long-term mechanical ventilation. Chest 1997;111(3):686-691.
-
(1997)
Chest
, vol.111
, Issue.3
, pp. 686-691
-
-
Hurni, J.M.1
Fiehl, F.2
Lazor, R.3
Leuenberger, P.4
Perret, C.5
-
43
-
-
0023907089
-
Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit
-
Cohen IL, Weinberg PF, Fein IA, Rowinski GS. Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med 1988;16(3):277-279.
-
(1988)
Crit Care Med
, vol.16
, Issue.3
, pp. 277-279
-
-
Cohen, I.L.1
Weinberg, P.F.2
Fein, I.A.3
Rowinski, G.S.4
-
44
-
-
0030443959
-
Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices
-
Villafane MC, Cinnella G, Lofaso F, Isabey D, Harf A, Lemaire F, Brochard L. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices. Anesthesiology 1996;85(6):1341-1349.
-
(1996)
Anesthesiology
, vol.85
, Issue.6
, pp. 1341-1349
-
-
Villafane, M.C.1
Cinnella, G.2
Lofaso, F.3
Isabey, D.4
Harf, A.5
Lemaire, F.6
Brochard, L.7
-
45
-
-
34447634744
-
And now for the rest of the story (letter)
-
Hess DR. And now for the rest of the story (letter). Respir Care 2002;47(6):696-699.
-
(2002)
Respir Care
, vol.47
, Issue.6
, pp. 696-699
-
-
Hess, DR.1
-
46
-
-
0034112596
-
Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
-
Davis K Jr, Evans SL, Campbell RS, Johannigman JA, Luchette FA, Porembka DT, Branson RD. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 2000;28(5):1412-1418.
-
(2000)
Crit Care Med
, vol.28
, Issue.5
, pp. 1412-1418
-
-
Davis Jr, K.1
Evans, S.L.2
Campbell, R.S.3
Johannigman, J.A.4
Luchette, F.A.5
Porembka, D.T.6
Branson, R.D.7
-
47
-
-
0036155170
-
Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days
-
Thomachot L, Leone M, Razzouk K, Antonini F, Vialet R, Martin C. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 2002;30(1):232-237.
-
(2002)
Crit Care Med
, vol.30
, Issue.1
, pp. 232-237
-
-
Thomachot, L.1
Leone, M.2
Razzouk, K.3
Antonini, F.4
Vialet, R.5
Martin, C.6
-
48
-
-
0029174060
-
Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia
-
Djedaini K, Billiard M, Mier L, Le Bourdelles G, Brun P, Markowicz P, et al. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995;152(5 Pt 1):1562-1569.
-
(1995)
Am J Respir Crit Care Med
, vol.152
, Issue.5 PART 1
, pp. 1562-1569
-
-
Djedaini, K.1
Billiard, M.2
Mier, L.3
Le Bourdelles, G.4
Brun, P.5
Markowicz, P.6
-
49
-
-
0033124708
-
Changing heat and moisture exchangers every 48 hours does not increase the incidence of nosocomial pneumonia
-
Daumal F, Colpart E, Manoury B, Mariani M, Daumal M. Changing heat and moisture exchangers every 48 hours does not increase the incidence of nosocomial pneumonia. Infect Control Hosp Epidemiol 1999;20(5):347-349.
-
(1999)
Infect Control Hosp Epidemiol
, vol.20
, Issue.5
, pp. 347-349
-
-
Daumal, F.1
Colpart, E.2
Manoury, B.3
Mariani, M.4
Daumal, M.5
-
50
-
-
0031936853
-
Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours
-
Thomachot L, Vialet R, Viguier JM, Sidier B, Roulier P, Martin C. Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours. Crit Care Med 1998;26(3):477-481.
-
(1998)
Crit Care Med
, vol.26
, Issue.3
, pp. 477-481
-
-
Thomachot, L.1
Vialet, R.2
Viguier, J.M.3
Sidier, B.4
Roulier, P.5
Martin, C.6
-
51
-
-
0032705361
-
Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: A clinical and microbiological evaluation
-
Boisson C, Viviand X, Arnaud S, Thomachot L, Miliani Y, Martin C. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation. Intensive Care Med 1999;25(11):1237-1243.
-
(1999)
Intensive Care Med
, vol.25
, Issue.11
, pp. 1237-1243
-
-
Boisson, C.1
Viviand, X.2
Arnaud, S.3
Thomachot, L.4
Miliani, Y.5
Martin, C.6
-
52
-
-
0034103469
-
Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours. a prospective, randomized study
-
Markowicz P, Ricard JD, Dreyfuss D, Mier L, Brun P, Coste F et al. Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours. a prospective, randomized study. Crit Care Med 2000;28(3):665-671.
-
(2000)
Crit Care Med
, vol.28
, Issue.3
, pp. 665-671
-
-
Markowicz, P.1
Ricard, J.D.2
Dreyfuss, D.3
Mier, L.4
Brun, P.5
Coste, F.6
-
53
-
-
0030874818
-
Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
-
Boots RJ, Howe S, George N, Harris FM, Faoagali J. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 1997;25(10):1707-1712.
-
(1997)
Crit Care Med
, vol.25
, Issue.10
, pp. 1707-1712
-
-
Boots, R.J.1
Howe, S.2
George, N.3
Harris, F.M.4
Faoagali, J.5
-
54
-
-
0034022538
-
Changing heat and moisture exchangers after 96 hours rather than after 24 hours: A clinical and microbiological evaluation
-
Thomachot L, Boisson C, Arnaud S, Michelet P, Cambon S, Martin C. Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Crit Care Med 2000;28(3):714-720.
-
(2000)
Crit Care Med
, vol.28
, Issue.3
, pp. 714-720
-
-
Thomachot, L.1
Boisson, C.2
Arnaud, S.3
Michelet, P.4
Cambon, S.5
Martin, C.6
-
55
-
-
0036218631
-
The combination of a heat and moisture exchanger and a Booster: A clinical and bacteriological evaluation over 96 hrs
-
Thomachot L, Viviand X, Boyadjiev I, Vialet R, Martin C. The combination of a heat and moisture exchanger and a Booster: a clinical and bacteriological evaluation over 96 hrs. Intensive Care Med 2002;28(2):147-153.
-
(2002)
Intensive Care Med
, vol.28
, Issue.2
, pp. 147-153
-
-
Thomachot, L.1
Viviand, X.2
Boyadjiev, I.3
Vialet, R.4
Martin, C.5
-
56
-
-
0033968236
-
Efficiency and safety of mechanical ventilation with a heat and moisture exhanger changed only once a week
-
Ricard JD, Le Miere E, Markowicz P, Lasry S, Saumon G, Djedaini K et al. Efficiency and safety of mechanical ventilation with a heat and moisture exhanger changed only once a week. Am J Respir Crit Care Med 2000;161(1):104-109.
-
(2000)
Am J Respir Crit Care Med
, vol.161
, Issue.1
, pp. 104-109
-
-
Ricard, J.D.1
Le Miere, E.2
Markowicz, P.3
Lasry, S.4
Saumon, G.5
Djedaini, K.6
-
57
-
-
0037350223
-
Heat and moisture exchangers in mechanically ventilated intensive care unit patients: A plea for an independent assessment of their performance
-
Thiery G, Boyer A, Pigne E, Salah A, De Lassence A, Dreyfuss D, Ricard JD. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance. Crit Care Med 2003;31(3):699-704.
-
(2003)
Crit Care Med
, vol.31
, Issue.3
, pp. 699-704
-
-
Thiery, G.1
Boyer, A.2
Pigne, E.3
Salah, A.4
De Lassence, A.5
Dreyfuss, D.6
Ricard, J.D.7
-
58
-
-
0028293191
-
Closed versus open endotracheal suctioning: Costs and physiologic consequences
-
Johnson KL, Kearney PA, Johnson SB, Niblett JB, MacMillan NL, McClain RE. Closed versus open endotracheal suctioning: costs and physiologic consequences. Crit Care Med 1994;22(4):658-666.
-
(1994)
Crit Care Med
, vol.22
, Issue.4
, pp. 658-666
-
-
Johnson, K.L.1
Kearney, P.A.2
Johnson, S.B.3
Niblett, J.B.4
MacMillan, N.L.5
McClain, R.E.6
-
59
-
-
0035044375
-
Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation
-
Cereda M, Villa F, Colombo E, Greco G, Nacoti M, Pesenti A. Closed system endotracheal suctioning maintains lung volume during volume-controlled mechanical ventilation. Intensive Care Med 2001;27(4):648-654.
-
(2001)
Intensive Care Med
, vol.27
, Issue.4
, pp. 648-654
-
-
Cereda, M.1
Villa, F.2
Colombo, E.3
Greco, G.4
Nacoti, M.5
Pesenti, A.6
-
60
-
-
0037541197
-
Prevention of endotracheal suctioning-induced alveolar derecruitment in acute lung injury
-
Maggiore SM, Lellouche F, Pigeot J, Taille S, Deye N, Durrmeyer X et al. Prevention of endotracheal suctioning-induced alveolar derecruitment in acute lung injury. Am J Respir Crit Care Med 2003;167(9):1215-1224.
-
(2003)
Am J Respir Crit Care Med
, vol.167
, Issue.9
, pp. 1215-1224
-
-
Maggiore, S.M.1
Lellouche, F.2
Pigeot, J.3
Taille, S.4
Deye, N.5
Durrmeyer, X.6
-
61
-
-
0025992033
-
Environmental contamination during tracheal suction: A comparison of disposable conventional catheters with a multiple-use closed system device
-
Cobley M, Atkins M, Jones PL. Environmental contamination during tracheal suction: a comparison of disposable conventional catheters with a multiple-use closed system device. Anaesthesia 1991;46(11):957-961.
-
(1991)
Anaesthesia
, vol.46
, Issue.11
, pp. 957-961
-
-
Cobley, M.1
Atkins, M.2
Jones, P.L.3
-
62
-
-
0022814488
-
Contamination of a multiple-use suction catheter in a closed-circuit system compared to contamination of a disposable, single-use suction catheter
-
Ritz R, Scott LR, Coyle MB, Pierson DJ. Contamination of a multiple-use suction catheter in a closed-circuit system compared to contamination of a disposable, single-use suction catheter. Respir Care 1986;31(11):1086-1091.
-
(1986)
Respir Care
, vol.31
, Issue.11
, pp. 1086-1091
-
-
Ritz, R.1
Scott, L.R.2
Coyle, M.B.3
Pierson, D.J.4
-
63
-
-
0037269902
-
Prolonged application of closed in-line suction catheters increases microbial colonization of the lower respiratory tract and bacterial growth on catheter surface
-
Freytag CC, Thies FL, Konig W, Welte T. Prolonged application of closed in-line suction catheters increases microbial colonization of the lower respiratory tract and bacterial growth on catheter surface. Infection 2003;31(1):31-37.
-
(2003)
Infection
, vol.31
, Issue.1
, pp. 31-37
-
-
Freytag, C.C.1
Thies, F.L.2
Konig, W.3
Welte, T.4
-
64
-
-
0036743319
-
Prevention of ventilator-associated pneumonia: Current practice in Canadian intensive care units
-
Heyland DK, Cook DJ, Dodek PM. Prevention of ventilator-associated pneumonia: current practice in Canadian intensive care units. J Crit Care 2002;17(3):161-167.
-
(2002)
J Crit Care
, vol.17
, Issue.3
, pp. 161-167
-
-
Heyland, D.K.1
Cook, D.J.2
Dodek, P.M.3
-
65
-
-
0025647269
-
Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care closed-suction system versus an open-suction system: Prospective, randomized study
-
Deppe SA, Kelly JW, Thoi LL, Chudy JH, Longfield RN, Ducey JP et al. Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care closed-suction system versus an open-suction system: prospective, randomized study. Crit Care Med 1990;18(12):1389-1393.
-
(1990)
Crit Care Med
, vol.18
, Issue.12
, pp. 1389-1393
-
-
Deppe, S.A.1
Kelly, J.W.2
Thoi, L.L.3
Chudy, J.H.4
Longfield, R.N.5
Ducey, J.P.6
-
66
-
-
0033852948
-
Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system
-
Combes P, Fauvage B, Oleyer C. Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system. Intensive Care Med 2000;26(7):878-882.
-
(2000)
Intensive Care Med
, vol.26
, Issue.7
, pp. 878-882
-
-
Combes, P.1
Fauvage, B.2
Oleyer, C.3
-
67
-
-
0041735363
-
Weekly versus daily changes of in-line suction catheters: Impact on rates of ventilator-associated pneumonia and associated costs
-
Stoller JK, Orens DK, Fatica C, Elliott M, Kester L, Woods J et al. Weekly versus daily changes of in-line suction catheters: impact on rates of ventilator-associated pneumonia and associated costs. Respir Care 2003;48(5):494-499.
-
(2003)
Respir Care
, vol.48
, Issue.5
, pp. 494-499
-
-
Stoller, J.K.1
Orens, D.K.2
Fatica, C.3
Elliott, M.4
Kester, L.5
Woods, J.6
-
68
-
-
0030855197
-
Mechanical ventilation with or without daily changes of in-line suction catheters
-
Kollef MH, Prentice D, Shapiro SD, Fraser VJ, Silver P, Trovillion E et al. Mechanical ventilation with or without daily changes of in-line suction catheters. Am J Respir Crit Care Med 1997;156(2 Pt 1):466-472.
-
(1997)
Am J Respir Crit Care Med
, vol.156
, Issue.2 PART 1
, pp. 466-472
-
-
Kollef, M.H.1
Prentice, D.2
Shapiro, S.D.3
Fraser, V.J.4
Silver, P.5
Trovillion, E.6
-
69
-
-
0021683471
-
Contaminated medication nebulizers in mechanical ventilator circuits: Source of bacterial aerosols
-
Craven DE, Lichtenberg DA, Goularte TA, Make BJ, McCabe WR. Contaminated medication nebulizers in mechanical ventilator circuits: source of bacterial aerosols. Am J Med 1984;77(5):834-838.
-
(1984)
Am J Med
, vol.77
, Issue.5
, pp. 834-838
-
-
Craven, D.E.1
Lichtenberg, D.A.2
Goularte, T.A.3
Make, B.J.4
McCabe, W.R.5
-
70
-
-
0025167321
-
Manual ventilation bags as a source for bacterial colonization of intubated patients
-
Weber DJ, Wilson MB, Rutala WA, Thomann CA. Manual ventilation bags as a source for bacterial colonization of intubated patients. Am Rev Respir Dis 1990;142(4):892-894.
-
(1990)
Am Rev Respir Dis
, vol.142
, Issue.4
, pp. 892-894
-
-
Weber, D.J.1
Wilson, M.B.2
Rutala, W.A.3
Thomann, C.A.4
-
71
-
-
0022512567
-
Potential in-hospital modes of transmission of Legionella pneumophila. Demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus
-
Woo AH, Yu VL, Goetz A. Potential in-hospital modes of transmission of Legionella pneumophila. Demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus. Am J Med 1986;80(4):567-573.
-
(1986)
Am J Med
, vol.80
, Issue.4
, pp. 567-573
-
-
Woo, A.H.1
Yu, V.L.2
Goetz, A.3
-
72
-
-
0030863031
-
Patient transport from intensive care increases the risk of developing ventilator-associated pneumonia
-
Kollef MH, Von Harz B, Prentice D, Shapiro SD, Silver P, St John R, Trovillion E. Patient transport from intensive care increases the risk of developing ventilator-associated pneumonia. Chest 1997;112(3):765-773.
-
(1997)
Chest
, vol.112
, Issue.3
, pp. 765-773
-
-
Kollef, M.H.1
Von Harz, B.2
Prentice, D.3
Shapiro, S.D.4
Silver, P.5
St John, R.6
Trovillion, E.7
-
73
-
-
0036852962
-
Effect of an education program aimed at reducing the occurrence of ventilator-associated pneumonia
-
Zack JE, Garrison T, Trovillion E, Clinkscale D, Coopersmith CM, Fraser VJ, Kollef MH. Effect of an education program aimed at reducing the occurrence of ventilator-associated pneumonia. Crit Care Med 2002;30(11):2407-2412.
-
(2002)
Crit Care Med
, vol.30
, Issue.11
, pp. 2407-2412
-
-
Zack, J.E.1
Garrison, T.2
Trovillion, E.3
Clinkscale, D.4
Coopersmith, C.M.5
Fraser, V.J.6
Kollef, M.H.7
|