-
1
-
-
0033782961
-
Ventilator circuit and secretion management strategies: A Franco-Canadian survey
-
Cook D, Ricard JD, Reeve B, Randall J, Wigg M, Brochard L, Dreyfuss D. Ventilator circuit and secretion management strategies: a Franco-Canadian survey. Crit Care Med 2000;28:3547-3554.
-
(2000)
Crit Care Med
, vol.28
, pp. 3547-3554
-
-
Cook, D.1
Ricard, J.D.2
Reeve, B.3
Randall, J.4
Wigg, M.5
Brochard, L.6
Dreyfuss, D.7
-
2
-
-
0029803459
-
Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa
-
Williams R, Rankin N, Smith T, Galler D, Seakins P. Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa. Crit Care Med 1996;24:1920-1929.
-
(1996)
Crit Care Med
, vol.24
, pp. 1920-1929
-
-
Williams, R.1
Rankin, N.2
Smith, T.3
Galler, D.4
Seakins, P.5
-
3
-
-
0023907089
-
Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit
-
Cohen IL, Weinberg PF, Fein IA, Rowinski GS. Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med 1988;16:277-279.
-
(1988)
Crit Care Med
, vol.16
, pp. 277-279
-
-
Cohen, I.L.1
Weinberg, P.F.2
Fein, I.A.3
Rowinski, G.S.4
-
4
-
-
0025015270
-
Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
-
Martin C, Perrin G, Gevaudan MJ, Saux P, Gouin F. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 1990;97:144-149.
-
(1990)
Chest
, vol.97
, pp. 144-149
-
-
Martin, C.1
Perrin, G.2
Gevaudan, M.J.3
Saux, P.4
Gouin, F.5
-
5
-
-
0030443959
-
Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices
-
Villafane MC, Cinnella G, Lofaso F, Isabey D, Harf A, Lemaire F, Brochard L. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices. Anesthesiology 1996;85:1341-1349.
-
(1996)
Anesthesiology
, vol.85
, pp. 1341-1349
-
-
Villafane, M.C.1
Cinnella, G.2
Lofaso, F.3
Isabey, D.4
Harf, A.5
Lemaire, F.6
Brochard, L.7
-
6
-
-
0035096607
-
Changing patterns of airway accidents in intubated ICU patients
-
Kapadia FN, Bajan KB, Singh S, Mathew B, Nath A, Wadkar S. Changing patterns of airway accidents in intubated ICU patients. Intensive Care Med 2001;27:296-300.
-
(2001)
Intensive Care Med
, vol.27
, pp. 296-300
-
-
Kapadia, F.N.1
Bajan, K.B.2
Singh, S.3
Mathew, B.4
Nath, A.5
Wadkar, S.6
-
7
-
-
0034754229
-
Factors associated with blocked tracheal tubes
-
Kapadia FN. Factors associated with blocked tracheal tubes. Intensive Care Med 2001;27:1679-1681.
-
(2001)
Intensive Care Med
, vol.27
, pp. 1679-1681
-
-
Kapadia, F.N.1
-
8
-
-
0030896388
-
Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation
-
Hurni JM, Feihl F, Lazor R, Leuenberger P, Perret C. Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 1997;111:686-691.
-
(1997)
Chest
, vol.111
, pp. 686-691
-
-
Hurni, J.M.1
Feihl, F.2
Lazor, R.3
Leuenberger, P.4
Perret, C.5
-
9
-
-
0028968722
-
Mechanical ventilation with heated humidifiers or heat and moisture exchangers: Effects on patient colonization and incidence of nosocomial pneumonia
-
Dreyfuss D, Djedaini K, Gros I, Mier L, Le Bourdelles G, Cohen Y, Estagnasie P, Coste F, Boussougant Y. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995;151:986-992.
-
(1995)
Am J Respir Crit Care Med
, vol.151
, pp. 986-992
-
-
Dreyfuss, D.1
Djedaini, K.2
Gros, I.3
Mier, L.4
Le Bourdelles, G.5
Cohen, Y.6
Estagnasie, P.7
Coste, F.8
Boussougant, Y.9
-
10
-
-
0027451823
-
Humidification in the intensive care unit: Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier
-
Branson RD, Davis K Jr, Campbell RS, Johnson DJ, Porembka DT. Humidification in the intensive care unit: prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 1993;104:1800-1805.
-
(1993)
Chest
, vol.104
, pp. 1800-1805
-
-
Branson, R.D.1
Davis Jr., K.2
Campbell, R.S.3
Johnson, D.J.4
Porembka, D.T.5
-
11
-
-
0030874818
-
Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
-
Boots RJ, Howe S, George N, Harris FM, Faoagali J. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 1997;25:1707-1712.
-
(1997)
Crit Care Med
, vol.25
, pp. 1707-1712
-
-
Boots, R.J.1
Howe, S.2
George, N.3
Harris, F.M.4
Faoagali, J.5
-
12
-
-
0031888824
-
A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
-
Kollef MH, Shapiro SD, Boyd V, Silver P, Von Harz B, Trovillion E, Prentice D. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 1998;113:759-767.
-
(1998)
Chest
, vol.113
, pp. 759-767
-
-
Kollef, M.H.1
Shapiro, S.D.2
Boyd, V.3
Silver, P.4
Von Harz, B.5
Trovillion, E.6
Prentice, D.7
-
13
-
-
0033030246
-
Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
-
Thomachot L, Vialet R, Arnaud S, Barberon B, Michel-Nguyen A, Martin C. Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 1999;27:923-928.
-
(1999)
Crit Care Med
, vol.27
, pp. 923-928
-
-
Thomachot, L.1
Vialet, R.2
Arnaud, S.3
Barberon, B.4
Michel-Nguyen, A.5
Martin, C.6
-
14
-
-
0031733848
-
Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia
-
Thomachot L, Viviand X, Arnaud S, Boisson C, Martin CD. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 1998;114:1383-1389.
-
(1998)
Chest
, vol.114
, pp. 1383-1389
-
-
Thomachot, L.1
Viviand, X.2
Arnaud, S.3
Boisson, C.4
Martin, C.D.5
-
15
-
-
0034797673
-
A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia
-
Memish Z, Oni G, Djazmati W, Cunningham G, Mah M. A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 2001;21:301-305.
-
(2001)
Am J Infect Control
, vol.21
, pp. 301-305
-
-
Memish, Z.1
Oni, G.2
Djazmati, W.3
Cunningham, G.4
Mah, M.5
-
16
-
-
0029174060
-
Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia
-
Djedaini K, Billiard M, Mier L, Le Bourdelles G, Brun P, Markowicz P, Estagnasie P, Coste F, Boussougant Y, Dreyfuss D. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995;152:1562-1569.
-
(1995)
Am J Respir Crit Care Med
, vol.152
, pp. 1562-1569
-
-
Djedaini, K.1
Billiard, M.2
Mier, L.3
Le Bourdelles, G.4
Brun, P.5
Markowicz, P.6
Estagnasie, P.7
Coste, F.8
Boussougant, Y.9
Dreyfuss, D.10
-
17
-
-
0034112596
-
Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
-
Davis K Jr, Evans SL, Campbell RS, Johannigman JA, Luchette FA, Porembka DT, Branson RD. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 2000;28:1412-1418.
-
(2000)
Crit Care Med
, vol.28
, pp. 1412-1418
-
-
Davis Jr., K.1
Evans, S.L.2
Campbell, R.S.3
Johannigman, J.A.4
Luchette, F.A.5
Porembka, D.T.6
Branson, R.D.7
-
18
-
-
0033968236
-
Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week
-
Ricard JD, Le Miere E, Markowicz P, Lasry S, Saumon G, Djedaini K, Coste F, Dreyfuss D. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 2000;161:104-109.
-
(2000)
Am J Respir Crit Care Med
, vol.161
, pp. 104-109
-
-
Ricard, J.D.1
Le Miere, E.2
Markowicz, P.3
Lasry, S.4
Saumon, G.5
Djedaini, K.6
Coste, F.7
Dreyfuss, D.8
-
19
-
-
0033040999
-
Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill
-
Ricard JD, Markowicz P, Djedaini K, Mier L, Coste F, Dreyfuss D. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. Chest 1999;115:1646-1652.
-
(1999)
Chest
, vol.115
, pp. 1646-1652
-
-
Ricard, J.D.1
Markowicz, P.2
Djedaini, K.3
Mier, L.4
Coste, F.5
Dreyfuss, D.6
-
20
-
-
0031936853
-
Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours
-
Thomachot L, Vialet R, Viguier JM, Sidier B, Roulier P, Martin C. Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours. Crit Care Med 1998;26:477-481.
-
(1998)
Crit Care Med
, vol.26
, pp. 477-481
-
-
Thomachot, L.1
Vialet, R.2
Viguier, J.M.3
Sidier, B.4
Roulier, P.5
Martin, C.6
-
21
-
-
0026446257
-
Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min
-
Martin C, Papazian L, Perrin G, Bantz P, Gouin F. Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min. Chest 1992; 102:1347-1350.
-
(1992)
Chest
, vol.102
, pp. 1347-1350
-
-
Martin, C.1
Papazian, L.2
Perrin, G.3
Bantz, P.4
Gouin, F.5
-
22
-
-
0028073939
-
Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min
-
Martin C, Papazian L, Perrin G, Saux P, Gouin F. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min. Crit Care Med 1994;22:1871-1876.
-
(1994)
Crit Care Med
, vol.22
, pp. 1871-1876
-
-
Martin, C.1
Papazian, L.2
Perrin, G.3
Saux, P.4
Gouin, F.5
-
23
-
-
0029061970
-
Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min
-
Martin C, Thomachot L, Quinio B, Viviand X, Albanese J. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Chest 1995; 107:1411-1415.
-
(1995)
Chest
, vol.107
, pp. 1411-1415
-
-
Martin, C.1
Thomachot, L.2
Quinio, B.3
Viviand, X.4
Albanese, J.5
-
24
-
-
0030443312
-
Noninvasive estimate of work of breathing due to the endotracheal tube
-
Heyer L, Louis B, Isabey D, Lofaso F, Brochard L, Fredberg JJ, Harf A. Noninvasive estimate of work of breathing due to the endotracheal tube. Anesthesiology 1996;85:1324-1333.
-
(1996)
Anesthesiology
, vol.85
, pp. 1324-1333
-
-
Heyer, L.1
Louis, B.2
Isabey, D.3
Lofaso, F.4
Brochard, L.5
Fredberg, J.J.6
Harf, A.7
-
25
-
-
0033009943
-
Changes in the work of breathing induced by tracheotomy in ventilator-dependent patients
-
Diehl JL, El Atrous S, Touchard D, Lemaire F, Brochard L. Changes in the work of breathing induced by tracheotomy in ventilator-dependent patients. Am J Respir Crit Care Med 1999;159:383-388.
-
(1999)
Am J Respir Crit Care Med
, vol.159
, pp. 383-388
-
-
Diehl, J.L.1
El Atrous, S.2
Touchard, D.3
Lemaire, F.4
Brochard, L.5
-
26
-
-
0026665853
-
Relative humidity, not absolute humidity, is of great importance when using a humidifier with a heating wire
-
Miyao H, Hirokawa T, Miyasaka K, Kawazoe T. Relative humidity, not absolute humidity, is of great importance when using a humidifier with a heating wire. Crit Care Med 1992;20:674-679.
-
(1992)
Crit Care Med
, vol.20
, pp. 674-679
-
-
Miyao, H.1
Hirokawa, T.2
Miyasaka, K.3
Kawazoe, T.4
-
27
-
-
0030879788
-
A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: Rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
-
Kirton OC, DeHaven B, Morgan J, Morejon O, Civetta J. A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 1997;112:1055-1059.
-
(1997)
Chest
, vol.112
, pp. 1055-1059
-
-
Kirton, O.C.1
DeHaven, B.2
Morgan, J.3
Morejon, O.4
Civetta, J.5
-
28
-
-
30444443974
-
Ventilator-associated pneumonia: Effects of heat and moisture exchangers and heated water humidificators
-
Lacherade JC, Auburtin M, Soufir L, Van de Louw A, Cerf C, Rebuffat Y, Reizzega S, Ricard JD, Lellouche L, Lemaire F, et al. Ventilator-associated pneumonia: effects of heat and moisture exchangers and heated water humidificators [abstract]. Intensive Care Med 2002;28:A507.
-
(2002)
Intensive Care Med
, vol.28
-
-
Lacherade, J.C.1
Auburtin, M.2
Soufir, L.3
Van De Louw, A.4
Cerf, C.5
Rebuffat, Y.6
Reizzega, S.7
Ricard, J.D.8
Lellouche, L.9
Lemaire, F.10
-
29
-
-
8444230357
-
Influence of ambient air and ventilator output temperature on performances of new heated humidifiers
-
Lellouche L, Taillé S, Maggiore SM, Qader S, L'Her E, Deye N, Brochard L. Influence of ambient air and ventilator output temperature on performances of new heated humidifiers [abstract]. Am J Respir Crit Care Med 2002;166:A05.s
-
(2002)
Am J Respir Crit Care Med
, vol.166
-
-
Lellouche, L.1
Taillé, S.2
Maggiore, S.M.3
Qader, S.4
L'Her, E.5
Deye, N.6
Brochard, L.7
-
30
-
-
8444244367
-
Advantages and drawbacks of a heated humidifier with compensation of under-humidification
-
Lellouche L, Qader S, L'Her E, Taillé S, Deye N, Demoule A, Brochard L. Advantages and drawbacks of a heated humidifier with compensation of under-humidification [abstract]. Am J Respir Crit Care Med 2003;167:A909.
-
(2003)
Am J Respir Crit Care Med
, vol.167
-
-
Lellouche, L.1
Qader, S.2
L'Her, E.3
Taillé, S.4
Deye, N.5
Demoule, A.6
Brochard, L.7
-
32
-
-
0036281138
-
Evaluation of heated humidifiers for use on intubated patients: A comparative study of humidifying efficiency, flow resistance, and alarm functions using a lung model
-
Rathgeber J, Kazmaier S, Penack O, Zuchner K. Evaluation of heated humidifiers for use on intubated patients: a comparative study of humidifying efficiency, flow resistance, and alarm functions using a lung model. Intensive Care Med 2002;28:731-739.
-
(2002)
Intensive Care Med
, vol.28
, pp. 731-739
-
-
Rathgeber, J.1
Kazmaier, S.2
Penack, O.3
Zuchner, K.4
-
33
-
-
0037350223
-
Heat and moisture exchangers in mechanically ventilated intensive care unit patients: A plea for an independent assessment of their performance
-
Thiery G, Boyer A, Pigne E, Salah A. De Lassence A, Dreyfuss D, Ricard JD. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance. Crit Care Med 2003;31:699-704.
-
(2003)
Crit Care Med
, vol.31
, pp. 699-704
-
-
Thiery, G.1
Boyer, A.2
Pigne, E.3
Salah, A.4
De Lassence, A.5
Dreyfuss, D.6
Ricard, J.D.7
-
34
-
-
85012491224
-
Efficacy of nine heat and moisture exchangers for intraoperative airway heat conservation
-
Tsubota K, Harada J, Goto Y. Efficacy of nine heat and moisture exchangers for intraoperative airway heat conservation. J Aerosol Med 1991;4:117-125.
-
(1991)
J Aerosol Med
, vol.4
, pp. 117-125
-
-
Tsubota, K.1
Harada, J.2
Goto, Y.3
-
35
-
-
0026649096
-
An evaluation of the heat and moisture exchange performance of four ventilator circuit filters
-
Jackson C, Webb AR. An evaluation of the heat and moisture exchange performance of four ventilator circuit filters. Intensive Care Med 1992; 18:264-268.
-
(1992)
Intensive Care Med
, vol.18
, pp. 264-268
-
-
Jackson, C.1
Webb, A.R.2
-
36
-
-
0027302769
-
Comparative evaluation of three heat and moisture exchangers during short-term postoperative mechanical ventilation
-
Sottiaux T, Mignolet G, Damas P, Lamy M. Comparative evaluation of three heat and moisture exchangers during short-term postoperative mechanical ventilation. Chest 1993;104;220-224.
-
(1993)
Chest
, vol.104
, pp. 220-224
-
-
Sottiaux, T.1
Mignolet, G.2
Damas, P.3
Lamy, M.4
-
37
-
-
0028889953
-
Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices
-
Vanderbroucke-Grauls CM, Teeuw KB, Ballemans K, Lavooij C, Cornelisse PB, Verhoef J. Bacterial and viral removal efficiency, heat and moisture exchange properties of four filtration devices. J Hosp Infect 1995;29:45-56.
-
(1995)
J Hosp Infect
, vol.29
, pp. 45-56
-
-
Vanderbroucke-Grauls, C.M.1
Teeuw, K.B.2
Ballemans, K.3
Lavooij, C.4
Cornelisse, P.B.5
Verhoef, J.6
-
38
-
-
0034103469
-
Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: A prospective, randomized study
-
Markowicz P, Ricard JD, Dreyfuss D, Mier L, Brun P, Coste F, Boussougant Y, Djedaini K. Safety, efficacy, and cost-effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Crit Care Med 2000;28:665-671.
-
(2000)
Crit Care Med
, vol.28
, pp. 665-671
-
-
Markowicz, P.1
Ricard, J.D.2
Dreyfuss, D.3
Mier, L.4
Brun, P.5
Coste, F.6
Boussougant, Y.7
Djedaini, K.8
-
39
-
-
0027428663
-
Performance of a hydrophobic heat and moisture exchanger at different ambient temperatures
-
Croci M, Elena A, Solca M. Performance of a hydrophobic heat and moisture exchanger at different ambient temperatures. Intensive Care Med 1993;19:351-352.
-
(1993)
Intensive Care Med
, vol.19
, pp. 351-352
-
-
Croci, M.1
Elena, A.2
Solca, M.3
-
40
-
-
0026907566
-
AARC clinical practice guideline: Humidification during mechanical ventilation: American Association for Respiratory Care
-
1992. AARC clinical practice guideline: humidification during mechanical ventilation: American Association for Respiratory Care. Respir Care 37:887-890.
-
(1992)
Respir Care
, vol.37
, pp. 887-890
-
-
-
41
-
-
0018718705
-
The humidification of anaesthetic gases: Its importance and control
-
Chalon J, Ali M, Ramanathan S, Turndorf H. The humidification of anaesthetic gases: its importance and control. Can Anaesth Soc J 1979;26:361-366.
-
(1979)
Can Anaesth Soc J
, vol.26
, pp. 361-366
-
-
Chalon, J.1
Ali, M.2
Ramanathan, S.3
Turndorf, H.4
-
42
-
-
0020083698
-
Contamination of mechanical ventilators with tubing changes every 24 or 48 hours
-
Craven DE, Connolly MG Jr, Lichtenberg DA, Primeau PJ, McCabe WR. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med 1982;306:1505-1509.
-
(1982)
N Engl J Med
, vol.306
, pp. 1505-1509
-
-
Craven, D.E.1
Connolly Jr., M.G.2
Lichtenberg, D.A.3
Primeau, P.J.4
McCabe, W.R.5
-
43
-
-
0021275019
-
Contaminated condensate in mechanical ventilator circuits: A risk factor for nosocomial pneumonia?
-
Craven DE, Goularte TA, Make BJ. Contaminated condensate in mechanical ventilator circuits: a risk factor for nosocomial pneumonia? Am Rev Respir Dis 1984;129:625-628.
-
(1984)
Am Rev Respir Dis
, vol.129
, pp. 625-628
-
-
Craven, D.E.1
Goularte, T.A.2
Make, B.J.3
-
44
-
-
0345024323
-
New heated breathing circuits do not prevent condensation and contamination of ventilator circuits with heated humidifiers
-
Ricard JD, Hidri N, Blivet A, Kalinowski H, Joly-Guillou ML, Dreyfuss D. New heated breathing circuits do not prevent condensation and contamination of ventilator circuits with heated humidifiers. Am J Respir Crit Care Med 2003;167:A861.
-
(2003)
Am J Respir Crit Care Med
, vol.167
-
-
Ricard, J.D.1
Hidri, N.2
Blivet, A.3
Kalinowski, H.4
Joly-Guillou, M.L.5
Dreyfuss, D.6
-
45
-
-
0030813513
-
Correlation between simple clinical parameters and the in vitro humidification characteristics of filter heat and moisture exchangers: Groupe de Travail sur les Respirateurs
-
Beydon L, Tong D, Jackson N, Dreyfuss D. Correlation between simple clinical parameters and the in vitro humidification characteristics of filter heat and moisture exchangers: Groupe de Travail sur les Respirateurs. Chest 1997;112:739-744.
-
(1997)
Chest
, vol.112
, pp. 739-744
-
-
Beydon, L.1
Tong, D.2
Jackson, N.3
Dreyfuss, D.4
|