-
1
-
-
0029803459
-
Relationship between the humidity and temperature of inspired gases and the function of the airway mucosa
-
Williams R, Rankin N, Smith T, et al: Relationship between the humidity and temperature of inspired gases and the function of the airway mucosa. Crit Care Med 1996; 24:1920-1929
-
(1996)
Crit Care Med
, vol.24
, pp. 1920-1929
-
-
Williams, R.1
Rankin, N.2
Smith, T.3
-
2
-
-
0346753421
-
system report: Data summary from January 1992 through June 2003, issued August 2003
-
National Nosocomial Infections Surveillance NNIS
-
National Nosocomial Infections Surveillance (NNIS) system report: Data summary from January 1992 through June 2003, issued August 2003. Am J Infect Control 2003; 31:481-498
-
(2003)
Am J Infect Control
, vol.31
, pp. 481-498
-
-
-
3
-
-
0032939662
-
The attributable morbidity and mortality of ventilator-associated pneumonia in the critically ill patient. The Canadian Critical Trials Group
-
Heyland DK, Cook DJ, Griffith L, et al: The attributable morbidity and mortality of ventilator-associated pneumonia in the critically ill patient. The Canadian Critical Trials Group. Am J Respir Crit Care Med 1999; 159:1249-1256
-
(1999)
Am J Respir Crit Care Med
, vol.159
, pp. 1249-1256
-
-
Heyland, D.K.1
Cook, D.J.2
Griffith, L.3
-
4
-
-
0036528966
-
Ventilator-associated pneumonia: State of the art
-
Chastre J, Fagon JY: Ventilator-associated pneumonia: State of the art. Am J Respir Crit Care Med 2002; 165:867-903
-
(2002)
Am J Respir Crit Care Med
, vol.165
, pp. 867-903
-
-
Chastre, J.1
Fagon, J.Y.2
-
5
-
-
27244435000
-
The ventilator circuit and ventilator-associated pneumonia
-
Branson RD: The ventilator circuit and ventilator-associated pneumonia. Respir Care 2005; 50:774-785
-
(2005)
Respir Care
, vol.50
, pp. 774-785
-
-
Branson, R.D.1
-
6
-
-
0021275019
-
Contaminated condensate in mechanical ventilator circuits: A risk factor for nosocomial pneumonia?
-
Craven DE, Goularte TA, Make BJ: Contaminated condensate in mechanical ventilator circuits: A risk factor for nosocomial pneumonia? Am Rev Respir Dis 1984; 129:625-628
-
(1984)
Am Rev Respir Dis
, vol.129
, pp. 625-628
-
-
Craven, D.E.1
Goularte, T.A.2
Make, B.J.3
-
7
-
-
0032507210
-
Influence of airway management on ventilator-associated pneumonia: Evidence from randomized trials
-
Cook D, De Jonghe B, Brochard L, et al: Influence of airway management on ventilator-associated pneumonia: Evidence from randomized trials. JAMA 1998; 279:781-787
-
(1998)
JAMA
, vol.279
, pp. 781-787
-
-
Cook, D.1
De Jonghe, B.2
Brochard, L.3
-
8
-
-
0038036870
-
Humidification in the long-term ventilated patient: A systematic review
-
Bench S: Humidification in the long-term ventilated patient: A systematic review. Intensive Crit Care Nurs 2003; 19:75
-
(2003)
Intensive Crit Care Nurs
, vol.19
, pp. 75
-
-
Bench, S.1
-
9
-
-
0037453115
-
Prevention of ventilator-associated pneumonia: An evidence-based systematic review
-
Collard HR, Saint S, Matthay MA: Prevention of ventilator-associated pneumonia: An evidence-based systematic review. Ann Intern Med 2003; 138:494-501
-
(2003)
Ann Intern Med
, vol.138
, pp. 494-501
-
-
Collard, H.R.1
Saint, S.2
Matthay, M.A.3
-
10
-
-
1542394258
-
American Association for Respiratory Care. Care of the ventilator circuit and its relation to ventilator associated pneumonia
-
Hess DR, Kallstrom TJ, Mottram CD, et al: American Association for Respiratory Care. Care of the ventilator circuit and its relation to ventilator associated pneumonia. Respir Care 2003; 48:869-879
-
(2003)
Respir Care
, vol.48
, pp. 869-879
-
-
Hess, D.R.1
Kallstrom, T.J.2
Mottram, C.D.3
-
11
-
-
0025015270
-
Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
-
Martin C, Perrin G, Gevaudan MJ, et al: Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 1990; 97:144-149
-
(1990)
Chest
, vol.97
, pp. 144-149
-
-
Martin, C.1
Perrin, G.2
Gevaudan, M.J.3
-
12
-
-
0026611461
-
Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation
-
Roustan JP, Kienlen J, Aubas S, et al: Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 1992; 18:97-100
-
(1992)
Intensive Care Med
, vol.18
, pp. 97-100
-
-
Roustan, J.P.1
Kienlen, J.2
Aubas, S.3
-
13
-
-
0028968722
-
Mechanical ventilation with heated humidifiers or heat and moisture exchangers: Effects on patient colonization and incidence of nosocomial pneumonia
-
Dreyfuss D, Djedaini K, Gros I, et al: Mechanical ventilation with heated humidifiers or heat and moisture exchangers: Effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995; 151:986-992
-
(1995)
Am J Respir Crit Care Med
, vol.151
, pp. 986-992
-
-
Dreyfuss, D.1
Djedaini, K.2
Gros, I.3
-
14
-
-
0029831013
-
Comparison of three humidification techniques during mechanical ventilation: Patient selection, cost, and infection considerations
-
Branson RD, Davis K Jr, Brown R, et al: Comparison of three humidification techniques during mechanical ventilation: Patient selection, cost, and infection considerations. Respir Care 1996; 41:809-816
-
(1996)
Respir Care
, vol.41
, pp. 809-816
-
-
Branson, R.D.1
Davis Jr, K.2
Brown, R.3
-
15
-
-
0030879788
-
A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: Rates of ventilator-associated early-onset (community-acquired) or late onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
-
Kirton OC, De Haven B, Morgan J, et al: A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: Rates of ventilator-associated early-onset (community-acquired) or late onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 1997; 112:1055-1059
-
(1997)
Chest
, vol.112
, pp. 1055-1059
-
-
Kirton, O.C.1
De Haven, B.2
Morgan, J.3
-
16
-
-
0031888824
-
A randomized clinical trial comparing an extended use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
-
Kollef MH, Shapiro SD, Boyd V, et al: A randomized clinical trial comparing an extended use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 1998; 113:759-767
-
(1998)
Chest
, vol.113
, pp. 759-767
-
-
Kollef, M.H.1
Shapiro, S.D.2
Boyd, V.3
-
17
-
-
12944296648
-
Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: Meta-analysis of randomized controlled trials
-
Kola A, Eckmanns T, Gastmeier P: Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: Meta-analysis of randomized controlled trials. Intensive Care Med 2005; 31:5-11
-
(2005)
Intensive Care Med
, vol.31
, pp. 5-11
-
-
Kola, A.1
Eckmanns, T.2
Gastmeier, P.3
-
18
-
-
0030874818
-
Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
-
Boots RJ, Howe S, George N, et al: Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 1997; 25:1707-1712
-
(1997)
Crit Care Med
, vol.25
, pp. 1707-1712
-
-
Boots, R.J.1
Howe, S.2
George, N.3
-
19
-
-
0034797673
-
A randomized trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia
-
Memish ZA, Oni GA, Djazmati W, et al: A randomized trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 2001; 29:301-305
-
(2001)
Am J Infect Control
, vol.29
, pp. 301-305
-
-
Memish, Z.A.1
Oni, G.A.2
Djazmati, W.3
-
20
-
-
33745181141
-
Preventing ventilator-associated pneumonia: Tiptoeing through a minefield
-
Craven DE, Duncan RA: Preventing ventilator-associated pneumonia: Tiptoeing through a minefield. Am J Respir Crit Care Med 2006; 173:1297-1298
-
(2006)
Am J Respir Crit Care Med
, vol.173
, pp. 1297-1298
-
-
Craven, D.E.1
Duncan, R.A.2
-
21
-
-
30444447238
-
Impact of humidification systems on ventilator associated pneumonia: A randomized multicenter trial
-
Lacherade JC, Auburtin M, Cerf C, et al: Impact of humidification systems on ventilator associated pneumonia: A randomized multicenter trial. Am J Respir Crit Care Med 2005; 172:1276-1282
-
(2005)
Am J Respir Crit Care Med
, vol.172
, pp. 1276-1282
-
-
Lacherade, J.C.1
Auburtin, M.2
Cerf, C.3
-
22
-
-
33644604269
-
Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia
-
Boots RJ, George N, Faoagali JL, et al: Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia. Crit Care Med 2006; 34:687-693
-
(2006)
Crit Care Med
, vol.34
, pp. 687-693
-
-
Boots, R.J.1
George, N.2
Faoagali, J.L.3
-
23
-
-
34247550823
-
Ventilator-associated pneumonia using a heated humidifier or a heat and moisture exchanger: A randomized controlled trial
-
Lorente L, Lecuona M, Jimenez A, et al: Ventilator-associated pneumonia using a heated humidifier or a heat and moisture exchanger: A randomized controlled trial. Crit Care 2006; 10:R116
-
(2006)
Crit Care
, vol.10
-
-
Lorente, L.1
Lecuona, M.2
Jimenez, A.3
-
24
-
-
0033610734
-
Improving the quality of reports of meta-analyses of randomized controlled trials: The QUOROM statement
-
for the QUOROM group
-
Moher D, Cook DJ, Eastwood S, et al, for the QUOROM group: Improving the quality of reports of meta-analyses of randomized controlled trials: The QUOROM statement. Lancet 1999; 354:1896-1900
-
(1999)
Lancet
, vol.354
, pp. 1896-1900
-
-
Moher, D.1
Cook, D.J.2
Eastwood, S.3
-
25
-
-
0032558314
-
Does quality of reports of randomised trials affect estimates of intervention efficacy reported in meta-analyses?
-
Moher D, Jones A, Cook DJ, et al: Does quality of reports of randomised trials affect estimates of intervention efficacy reported in meta-analyses? Lancet 1998; 352:609-613
-
(1998)
Lancet
, vol.352
, pp. 609-613
-
-
Moher, D.1
Jones, A.2
Cook, D.J.3
-
27
-
-
0025761055
-
Heat and moisture exchanger vs heated humidifier during long term mechanical ventilation: A prospective randomized study
-
Misset B, Escudier B, Rivara D, et al: Heat and moisture exchanger vs heated humidifier during long term mechanical ventilation: A prospective randomized study. Chest 1991; 100:160-163
-
(1991)
Chest
, vol.100
, pp. 160-163
-
-
Misset, B.1
Escudier, B.2
Rivara, D.3
-
28
-
-
0030896388
-
Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation
-
Hurni JM, Feihl F, Lazor R, et al: Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 1997; 111:686-691
-
(1997)
Chest
, vol.111
, pp. 686-691
-
-
Hurni, J.M.1
Feihl, F.2
Lazor, R.3
-
29
-
-
13644269309
-
Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia
-
The American Thoracic Society and the Infectious Diseases Society of America Guideline Committee
-
The American Thoracic Society and the Infectious Diseases Society of America Guideline Committee: Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia. Am J Respir Crit Care Med 2005; 171:388-416
-
(2005)
Am J Respir Crit Care Med
, vol.171
, pp. 388-416
-
-
-
30
-
-
4043130212
-
Evidencebased clinical practice guideline for the prevention of ventilator-associated pneumonia
-
Dodek P, Keenan S, Cook D, et al: Evidencebased clinical practice guideline for the prevention of ventilator-associated pneumonia. Ann Intern Med 2004; 141:305-313
-
(2004)
Ann Intern Med
, vol.141
, pp. 305-313
-
-
Dodek, P.1
Keenan, S.2
Cook, D.3
-
31
-
-
1642525257
-
Guidelines for preventing health-care-associated pneumonia, 2003: Recommendations of the CDC and the Healthcare Infection Control Practices Advisory Committee
-
Tablan OC, Anderson LJ, Besser R, et al: Guidelines for preventing health-care-associated pneumonia, 2003: Recommendations of the CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Morb Mortal Wkly Rep 2004; 53:1-36
-
(2004)
MMWR Morb Mortal Wkly Rep
, vol.53
, pp. 1-36
-
-
Tablan, O.C.1
Anderson, L.J.2
Besser, R.3
-
32
-
-
0034960670
-
the European Task Force on Ventilator Associated Pneumonia: Ventilator-associated pneumonia
-
Torres A, Carlet J, the European Task Force on Ventilator Associated Pneumonia: Ventilator-associated pneumonia. Eur Respir J 2001; 17:1034-1045
-
(2001)
Eur Respir J
, vol.17
, pp. 1034-1045
-
-
Torres, A.1
Carlet, J.2
-
33
-
-
1042302704
-
The effects of active and passive humidification on ventilation associated nosocomial pneumonia
-
Kranabetter R, Leier M, Kammermeier D, et al: The effects of active and passive humidification on ventilation associated nosocomial pneumonia. Anaesthesist 2004; 53:29-35
-
(2004)
Anaesthesist
, vol.53
, pp. 29-35
-
-
Kranabetter, R.1
Leier, M.2
Kammermeier, D.3
-
34
-
-
0023907089
-
Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit
-
Cohen IL, Weinberg PF, Fein IA, et al: Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med 1988; 16:277-279
-
(1988)
Crit Care Med
, vol.16
, pp. 277-279
-
-
Cohen, I.L.1
Weinberg, P.F.2
Fein, I.A.3
-
35
-
-
0030443959
-
Gradual reduction on endotracheal tube diameter during mechanical ventilation via different humidification devices
-
Villafane MC, Cinaella G, Lofaso F, et al: Gradual reduction on endotracheal tube diameter during mechanical ventilation via different humidification devices. Anesthesiology 1996; 85:1341-1349
-
(1996)
Anesthesiology
, vol.85
, pp. 1341-1349
-
-
Villafane, M.C.1
Cinaella, G.2
Lofaso, F.3
-
36
-
-
34447634744
-
And now for the rest of the story
-
Hess DR: And now for the rest of the story. Respir Care 2002; 47:696-699
-
(2002)
Respir Care
, vol.47
, pp. 696-699
-
-
Hess, D.R.1
-
37
-
-
0037348565
-
Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: A prospective clinical hygrometric and bacteriologic study
-
Boyer A, Thiery G, Lasry S, et al: Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: A prospective clinical hygrometric and bacteriologic study. Crit Care Med 2003; 31:823-829
-
(2003)
Crit Care Med
, vol.31
, pp. 823-829
-
-
Boyer, A.1
Thiery, G.2
Lasry, S.3
-
38
-
-
0037350223
-
Heat and moisture exchangers in mechanically ventilated intensive care unit patients: A plea for an independent assessment of their performance
-
Thiery G, Boyer A, Lasry S, et al: Heat and moisture exchangers in mechanically ventilated intensive care unit patients: A plea for an independent assessment of their performance. Crit Care Med 2003; 31:699-704
-
(2003)
Crit Care Med
, vol.31
, pp. 699-704
-
-
Thiery, G.1
Boyer, A.2
Lasry, S.3
-
39
-
-
0033968236
-
Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week
-
Ricard JD, Le Miere E, Markowicz P, et al: Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 2000; 161:104-109
-
(2000)
Am J Respir Crit Care Med
, vol.161
, pp. 104-109
-
-
Ricard, J.D.1
Le Miere, E.2
Markowicz, P.3
-
40
-
-
0034103469
-
Safety, efficacy and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: A prospective, randomized study
-
Markowicz P, Ricard JD, Dreyfuss D, et al: Safety, efficacy and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: A prospective, randomized study. Crit Care Med 2000; 28:665-671
-
(2000)
Crit Care Med
, vol.28
, pp. 665-671
-
-
Markowicz, P.1
Ricard, J.D.2
Dreyfuss, D.3
-
42
-
-
33745647602
-
The effect of humidification on the incidence of ventilator-associated pneumonia
-
Ricard JD, Boyer A, Dreyfuss D: The effect of humidification on the incidence of ventilator-associated pneumonia. Respir Care Clin 2006; 12:263-273
-
(2006)
Respir Care Clin
, vol.12
, pp. 263-273
-
-
Ricard, J.D.1
Boyer, A.2
Dreyfuss, D.3
-
43
-
-
0033602066
-
The prevention of ventilator-associated pneumonia
-
Kollef MH: The prevention of ventilator-associated pneumonia. N Engl J Med 1999; 340:627-634
-
(1999)
N Engl J Med
, vol.340
, pp. 627-634
-
-
Kollef, M.H.1
-
44
-
-
0029174060
-
Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia
-
Djedaini K, Billiard M, Mier L, et al: Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995; 152:1562-1569
-
(1995)
Am J Respir Crit Care Med
, vol.152
, pp. 1562-1569
-
-
Djedaini, K.1
Billiard, M.2
Mier, L.3
-
45
-
-
0032705361
-
Changing a hygrophobic heat and moisture exchanger after 48 hours rather than 24 hours: A clinical and microbiological evaluation
-
Boisson C, Viviand X, Arnaud S, et al: Changing a hygrophobic heat and moisture exchanger after 48 hours rather than 24 hours: A clinical and microbiological evaluation. Intensive Care Med 1999; 25:1237-1243
-
(1999)
Intensive Care Med
, vol.25
, pp. 1237-1243
-
-
Boisson, C.1
Viviand, X.2
Arnaud, S.3
-
46
-
-
0036155170
-
Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days
-
Thomachot L, Leone M, Razzouk K, et al: Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 2002; 30:232-237
-
(2002)
Crit Care Med
, vol.30
, pp. 232-237
-
-
Thomachot, L.1
Leone, M.2
Razzouk, K.3
-
47
-
-
0034112596
-
Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
-
Davis K Jr, Evans SL, Campbell RS, et al: Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 2000; 28:1412-1418
-
(2000)
Crit Care Med
, vol.28
, pp. 1412-1418
-
-
Davis Jr, K.1
Evans, S.L.2
Campbell, R.S.3
-
48
-
-
0031733848
-
Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia
-
Thomachot L, Viviand X, Arnaud S, et al: Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 1998; 114:1383-1389
-
(1998)
Chest
, vol.114
, pp. 1383-1389
-
-
Thomachot, L.1
Viviand, X.2
Arnaud, S.3
-
50
-
-
0033030246
-
Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
-
Thomachot L, Vialet R, Arnaud S, et al: Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 1999; 27:923-928
-
(1999)
Crit Care Med
, vol.27
, pp. 923-928
-
-
Thomachot, L.1
Vialet, R.2
Arnaud, S.3
|