메뉴 건너뛰기




Volumn 15, Issue , 2013, Pages 309-336

Inductively Coupled Plasma Mass Spectrometers

Author keywords

Elemental chemical analysis; Inductively coupled plasma mass spectrometry; Isotope ratio measurement

Indexed keywords

ANALYTICAL GEOCHEMISTRY; ATMOSPHERIC PRESSURE; INDUCTIVELY COUPLED PLASMA; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; IONIZATION; ISOTOPES; KINETIC ENERGY; KINETICS;

EID: 84903797036     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-0-08-095975-7.01426-1     Document Type: Chapter
Times cited : (27)

References (83)
  • 1
    • 80053652818 scopus 로고    scopus 로고
    • Matrix effects in inductively coupled plasma mass spectrometry: A review
    • Agatemor C., Beauchemin D. Matrix effects in inductively coupled plasma mass spectrometry: A review. Analytica Chimica Acta 2011, 706:66-83.
    • (2011) Analytica Chimica Acta , vol.706 , pp. 66-83
    • Agatemor, C.1    Beauchemin, D.2
  • 3
    • 1642463856 scopus 로고    scopus 로고
    • Iron stable isotopes: Beyond biosignatures
    • Anbar A.D. Iron stable isotopes: Beyond biosignatures. Earth and Planetary Science Letters 2004, 217:223-236.
    • (2004) Earth and Planetary Science Letters , vol.217 , pp. 223-236
    • Anbar, A.D.1
  • 4
    • 30644476727 scopus 로고    scopus 로고
    • Molybdenum stable isotopes: Observations, interpretations and directions
    • Anbar A.D. Molybdenum stable isotopes: Observations, interpretations and directions. Reviews in Mineralogy and Geochemistry 2004, 55:429-454.
    • (2004) Reviews in Mineralogy and Geochemistry , vol.55 , pp. 429-454
    • Anbar, A.D.1
  • 6
    • 0003085631 scopus 로고    scopus 로고
    • A routine method for oxide and hydroxide interference corrections in ICP-MS chemical analysis of environmental and geological samples
    • Aries S., Valladon M., Polve M., Dupre B. A routine method for oxide and hydroxide interference corrections in ICP-MS chemical analysis of environmental and geological samples. Geostandards Newsletter - The Journal of Geostandards and Geoanalysis 2000, 24:19-31.
    • (2000) Geostandards Newsletter - The Journal of Geostandards and Geoanalysis , vol.24 , pp. 19-31
    • Aries, S.1    Valladon, M.2    Polve, M.3    Dupre, B.4
  • 7
    • 68849103521 scopus 로고    scopus 로고
    • Mass cytometry: Technique for real time single cell multitarget immunoassay based on inductively coupled plasma time-of-flight mass spectrometry
    • Bandura D.R., Baranov V.I., Ornatsky O.I., et al. Mass cytometry: Technique for real time single cell multitarget immunoassay based on inductively coupled plasma time-of-flight mass spectrometry. Analytical Chemistry 2009, 81:6813-6822.
    • (2009) Analytical Chemistry , vol.81 , pp. 6813-6822
    • Bandura, D.R.1    Baranov, V.I.2    Ornatsky, O.I.3
  • 8
    • 46149113497 scopus 로고    scopus 로고
    • Influence of non-spectral matrix effects on the accuracy of Pb isotope ratio measurement by MC-ICP-MS: Implications for the external normalization method of instrumental mass bias correction
    • Barling J., Weis D. Influence of non-spectral matrix effects on the accuracy of Pb isotope ratio measurement by MC-ICP-MS: Implications for the external normalization method of instrumental mass bias correction. Journal of Analytical Atomic Spectrometry 2008, 23:1017-1025.
    • (2008) Journal of Analytical Atomic Spectrometry , vol.23 , pp. 1017-1025
    • Barling, J.1    Weis, D.2
  • 9
    • 84858715444 scopus 로고    scopus 로고
    • An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry
    • Barling J., Weis D. An isotopic perspective on mass bias and matrix effects in multi-collector inductively-coupled-plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 2012, 27:653-662.
    • (2012) Journal of Analytical Atomic Spectrometry , vol.27 , pp. 653-662
    • Barling, J.1    Weis, D.2
  • 11
    • 2342454492 scopus 로고    scopus 로고
    • Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 2. Use with an inductively coupled plasma
    • Barnes J.H., Schilling G.D., Sperline R., et al. Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 2. Use with an inductively coupled plasma. Analytical Chemistry 2004, 76:2531-2536.
    • (2004) Analytical Chemistry , vol.76 , pp. 2531-2536
    • Barnes, J.H.1    Schilling, G.D.2    Sperline, R.3
  • 12
    • 0142124439 scopus 로고    scopus 로고
    • Methods for the determination of platinum group elements originating from the abrasion of automotive catalytic converters
    • Bencs L., Ravindra K., Van Grieken R. Methods for the determination of platinum group elements originating from the abrasion of automotive catalytic converters. Spectrochimica Acta Part B 2003, 58B:1723-1755.
    • (2003) Spectrochimica Acta Part B , vol.58 B , pp. 1723-1755
    • Bencs, L.1    Ravindra, K.2    Van Grieken, R.3
  • 13
    • 35348963587 scopus 로고    scopus 로고
    • Mass-dependent and -independent fractionation of Hg isotopes by photoreduction in aquatic systems
    • Bergquist B.A., Blum J.D. Mass-dependent and -independent fractionation of Hg isotopes by photoreduction in aquatic systems. Science 2007, 318:417-420.
    • (2007) Science , vol.318 , pp. 417-420
    • Bergquist, B.A.1    Blum, J.D.2
  • 15
    • 0000737829 scopus 로고
    • MS InterView: An elemental mass spectrometry spectral interference data base for Microsoft Windows
    • Burton L.L., Horlick G. MS InterView: An elemental mass spectrometry spectral interference data base for Microsoft Windows. Spectrochimica Acta Part B: Atomic Spectroscopy 1993, 48:E1063-E1064.
    • (1993) Spectrochimica Acta Part B: Atomic Spectroscopy , vol.48
    • Burton, L.L.1    Horlick, G.2
  • 17
    • 34347404756 scopus 로고    scopus 로고
    • Scaling NIST SRM 3149 for Se isotope analysis and isotopic variations of natural samples
    • Carignan J., Wen H. Scaling NIST SRM 3149 for Se isotope analysis and isotopic variations of natural samples. Chemical Geology 2007, 242:347-350.
    • (2007) Chemical Geology , vol.242 , pp. 347-350
    • Carignan, J.1    Wen, H.2
  • 18
    • 0001283276 scopus 로고    scopus 로고
    • Matrix induced isotopic mass fractionation in ICP-MS
    • Royal Society of Chemistry, Cambridge, G. Holand, S.D. Tanner (Eds.)
    • Carlson R.W., Hauri E.H. Matrix induced isotopic mass fractionation in ICP-MS. Plasma Source Mass Spectrometry: The New Millennium 2001, Royal Society of Chemistry, Cambridge. G. Holand, S.D. Tanner (Eds.).
    • (2001) Plasma Source Mass Spectrometry: The New Millennium
    • Carlson, R.W.1    Hauri, E.H.2
  • 19
    • 79955972747 scopus 로고    scopus 로고
    • Determination of chemical weathering rates from U series nuclides in soils and weathering profiles: Principles, applications and limitations
    • Chabaux F., Ma L., Stille P., et al. Determination of chemical weathering rates from U series nuclides in soils and weathering profiles: Principles, applications and limitations. Applied Geochemistry 2011, 26(Supplement):S20-S23.
    • (2011) Applied Geochemistry , vol.26 , Issue.SUPPL.
    • Chabaux, F.1    Ma, L.2    Stille, P.3
  • 20
    • 0024775843 scopus 로고
    • A simple, non-invasive method for the measurement of gas flow velocities in the inductively coupled plasma
    • Cicerone M.T., Farnsworth P.B. A simple, non-invasive method for the measurement of gas flow velocities in the inductively coupled plasma. Spectrochimica Acta Part B 1989, 44:897-907.
    • (1989) Spectrochimica Acta Part B , vol.44 , pp. 897-907
    • Cicerone, M.T.1    Farnsworth, P.B.2
  • 21
    • 53849087507 scopus 로고    scopus 로고
    • Laser ablation coupled with ICP-MS applied to U-Pb zircon geochronology: A review of recent advances
    • Cocherie A., Robert M. Laser ablation coupled with ICP-MS applied to U-Pb zircon geochronology: A review of recent advances. Gondwana Research 2008, 14:597-608.
    • (2008) Gondwana Research , vol.14 , pp. 597-608
    • Cocherie, A.1    Robert, M.2
  • 22
    • 84858311727 scopus 로고    scopus 로고
    • Classical and new procedures of whole rock dissolution for trace element determination by ICP-MS
    • Cotta A.J.B., Enzweiler J. Classical and new procedures of whole rock dissolution for trace element determination by ICP-MS. Geostandards and Geoanalytical Research 2011, 36:27-50.
    • (2011) Geostandards and Geoanalytical Research , vol.36 , pp. 27-50
    • Cotta, A.J.B.1    Enzweiler, J.2
  • 23
    • 0000599156 scopus 로고
    • Study of solids deposition on inductively coupled plasma mass spectrometry samplers and skimmers
    • Douglas D.J., Kerr L.A. Study of solids deposition on inductively coupled plasma mass spectrometry samplers and skimmers. Journal of Analytical Atomic Spectrometry 1988, 3:749-752.
    • (1988) Journal of Analytical Atomic Spectrometry , vol.3 , pp. 749-752
    • Douglas, D.J.1    Kerr, L.A.2
  • 24
    • 37749034393 scopus 로고    scopus 로고
    • The evolution and applications of multicollector ICPMS (MC-ICPMS)
    • Douthitt C.B. The evolution and applications of multicollector ICPMS (MC-ICPMS). Analytical and Bioanalytical Chemistry 2008, 390:437-440.
    • (2008) Analytical and Bioanalytical Chemistry , vol.390 , pp. 437-440
    • Douthitt, C.B.1
  • 25
    • 34249763833 scopus 로고
    • Interferences of oxide, hydroxide and chloride analyte species in the determination of rare-earth elements in geological samples by inductively coupled plasma-mass spectrometry
    • Dulski P. Interferences of oxide, hydroxide and chloride analyte species in the determination of rare-earth elements in geological samples by inductively coupled plasma-mass spectrometry. Fresenius' Journal of Analytical Chemistry 1994, 350:194-203.
    • (1994) Fresenius' Journal of Analytical Chemistry , vol.350 , pp. 194-203
    • Dulski, P.1
  • 26
    • 0030128864 scopus 로고    scopus 로고
    • Time-resolved inductively coupled plasma mass spectrometry measurements with individual, monodisperse drop sample introduction
    • Dziewatkoski M.P., Daniels L.B., Olesik J.W. Time-resolved inductively coupled plasma mass spectrometry measurements with individual, monodisperse drop sample introduction. Analytical Chemistry 1996, 68:1101-1109.
    • (1996) Analytical Chemistry , vol.68 , pp. 1101-1109
    • Dziewatkoski, M.P.1    Daniels, L.B.2    Olesik, J.W.3
  • 27
    • 36849069390 scopus 로고    scopus 로고
    • Comparative performance study of different sample introduction techniques for rapid and precise selenium isotope ratio determination using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS)
    • Elwaer N., Hintelmann H. Comparative performance study of different sample introduction techniques for rapid and precise selenium isotope ratio determination using multi-collector inductively coupled plasma mass spectrometry (MC-ICP/MS). Analytical and Bioanalytical Chemistry 2007, 389:1889-1899.
    • (2007) Analytical and Bioanalytical Chemistry , vol.389 , pp. 1889-1899
    • Elwaer, N.1    Hintelmann, H.2
  • 28
    • 0024385577 scopus 로고
    • Simple approach to reducing polyatomic ion interferences on arsenic and selenium in inductively coupled plasma mass spectrometry
    • Evans E.H., Ebdon L. Simple approach to reducing polyatomic ion interferences on arsenic and selenium in inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 1989, 4:299-300.
    • (1989) Journal of Analytical Atomic Spectrometry , vol.4 , pp. 299-300
    • Evans, E.H.1    Ebdon, L.2
  • 29
    • 70349144448 scopus 로고    scopus 로고
    • A comparison of ion and atom behavior in the first stage of an inductively coupled plasma mass spectrometer vacuum interface: Evidence of the effect of an ambipolar electric field
    • Farnsworth P.B., Spencer R.L., Radicic W.N., Taylor N., Macedone J., Ma H.B. A comparison of ion and atom behavior in the first stage of an inductively coupled plasma mass spectrometer vacuum interface: Evidence of the effect of an ambipolar electric field. Spectrochimica Acta Part B 2009, 64:905-910.
    • (2009) Spectrochimica Acta Part B , vol.64 , pp. 905-910
    • Farnsworth, P.B.1    Spencer, R.L.2    Radicic, W.N.3    Taylor, N.4    Macedone, J.5    Ma, H.B.6
  • 32
    • 0001094717 scopus 로고    scopus 로고
    • Magnetic sector ICPMS with desolvating micronebulization: Interference-free subpicogram determination of rare earth elements in natural samples
    • Field M.P., Sherrell R.M. Magnetic sector ICPMS with desolvating micronebulization: Interference-free subpicogram determination of rare earth elements in natural samples. Analytical Chemistry 1998, 70:4480-4486.
    • (1998) Analytical Chemistry , vol.70 , pp. 4480-4486
    • Field, M.P.1    Sherrell, R.M.2
  • 33
    • 0033599948 scopus 로고    scopus 로고
    • Optimal double and triple spiking for high precision lead isotopic measurement
    • Galer S.J.G. Optimal double and triple spiking for high precision lead isotopic measurement. Chemical Geology 1999, 157:255-274.
    • (1999) Chemical Geology , vol.157 , pp. 255-274
    • Galer, S.J.G.1
  • 34
    • 84982596648 scopus 로고
    • Simultaneous determination of thirty-seven trace elements in twenty-eight international rock standards by ICP-MS
    • Garbe-Schönberg C.-D. Simultaneous determination of thirty-seven trace elements in twenty-eight international rock standards by ICP-MS. Geostandards Newsletter 1993, 17:81-97.
    • (1993) Geostandards Newsletter , vol.17 , pp. 81-97
    • Garbe-Schönberg, C.-D.1
  • 35
    • 0000758476 scopus 로고
    • Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry
    • Gillson G.R., Douglas D.J., Fulford J.E., Halligan K.W., Tanner S.D. Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry. Analytical Chemistry 1988, 60:1472-1474.
    • (1988) Analytical Chemistry , vol.60 , pp. 1472-1474
    • Gillson, G.R.1    Douglas, D.J.2    Fulford, J.E.3    Halligan, K.W.4    Tanner, S.D.5
  • 36
    • 0034928275 scopus 로고    scopus 로고
    • Experimental evidence for the formation of doubly charged oxide and hydroxide ion in inductively coupled plasma mass spectrometry
    • Hattendorf B., Günther D. Experimental evidence for the formation of doubly charged oxide and hydroxide ion in inductively coupled plasma mass spectrometry. Fresenius' Journal of Analytical Chemistry 2001, 370:483-487.
    • (2001) Fresenius' Journal of Analytical Chemistry , vol.370 , pp. 483-487
    • Hattendorf, B.1    Günther, D.2
  • 37
    • 0027590338 scopus 로고
    • The effect of desolvating droplets and vaporizing particles on ionization and excitation in Ar inductively coupled plasmas
    • Hobbs S.E., Olesik J.W. The effect of desolvating droplets and vaporizing particles on ionization and excitation in Ar inductively coupled plasmas. Spectrochimica Acta Part B: Atomic Spectroscopy 1993, 48:817-833.
    • (1993) Spectrochimica Acta Part B: Atomic Spectroscopy , vol.48 , pp. 817-833
    • Hobbs, S.E.1    Olesik, J.W.2
  • 39
    • 33847085726 scopus 로고
    • Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements
    • Houk R.S., Fassel V.A., Flesch G.D., Svec H.J., Gray A.L., Taylor C.E. Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements. Analytical Chemistry 1980, 52:2283-2289.
    • (1980) Analytical Chemistry , vol.52 , pp. 2283-2289
    • Houk, R.S.1    Fassel, V.A.2    Flesch, G.D.3    Svec, H.J.4    Gray, A.L.5    Taylor, C.E.6
  • 42
    • 0025658281 scopus 로고
    • ICP-MS - A powerful tool for high-precision trace-element analysis in earth sciences: Evidence from analysis of selected U.S.G.S. reference samples
    • Jenner G.A., Longerich H.P., Jackson S.E., Fryer B.J. ICP-MS - A powerful tool for high-precision trace-element analysis in earth sciences: Evidence from analysis of selected U.S.G.S. reference samples. Chemical Geology 1990, 83:133-148.
    • (1990) Chemical Geology , vol.83 , pp. 133-148
    • Jenner, G.A.1    Longerich, H.P.2    Jackson, S.E.3    Fryer, B.J.4
  • 43
    • 0024032920 scopus 로고
    • Alleviation of overlap interferences for determination of potassium isotope ratios by inductively coupled plasma mass spectrometry
    • Jiang S.J., Houk R.S., Stevens M.A. Alleviation of overlap interferences for determination of potassium isotope ratios by inductively coupled plasma mass spectrometry. Analytical Chemistry 1988, 60:1217-1221.
    • (1988) Analytical Chemistry , vol.60 , pp. 1217-1221
    • Jiang, S.J.1    Houk, R.S.2    Stevens, M.A.3
  • 45
    • 3042641851 scopus 로고    scopus 로고
    • Collision and reaction cells in atomic mass spectrometry: Development, status, and applications
    • Koppenaal D.W., Eiden G.C., Barinaga C.J. Collision and reaction cells in atomic mass spectrometry: Development, status, and applications. Journal of Analytical Atomic Spectrometry 2004, 19:561-570.
    • (2004) Journal of Analytical Atomic Spectrometry , vol.19 , pp. 561-570
    • Koppenaal, D.W.1    Eiden, G.C.2    Barinaga, C.J.3
  • 46
    • 0025531583 scopus 로고
    • A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry
    • Lam J.W.H., Horlick G. A comparison of argon and mixed gas plasmas for inductively coupled plasma-mass spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 1990, 45:1313-1325.
    • (1990) Spectrochimica Acta Part B: Atomic Spectroscopy , vol.45 , pp. 1313-1325
    • Lam, J.W.H.1    Horlick, G.2
  • 47
    • 0001245748 scopus 로고
    • Use of aerosol processing and nitrogen-argon plasmas for reduction of oxide interference in inductively coupled plasma mass spectrometry
    • Lam J.W., Mclaren J.W. Use of aerosol processing and nitrogen-argon plasmas for reduction of oxide interference in inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 1990, 5:419-424.
    • (1990) Journal of Analytical Atomic Spectrometry , vol.5 , pp. 419-424
    • Lam, J.W.1    Mclaren, J.W.2
  • 48
    • 0032099117 scopus 로고    scopus 로고
    • Strontium isotope ratio measurements in prehistoric human bone samples by means of high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS)
    • Latkoczy C., Prohaska T., Stingeder G., Teschler-Nicola M. Strontium isotope ratio measurements in prehistoric human bone samples by means of high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Journal of Analytical Atomic Spectrometry 1998, 13:561-566.
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , pp. 561-566
    • Latkoczy, C.1    Prohaska, T.2    Stingeder, G.3    Teschler-Nicola, M.4
  • 49
    • 0023331109 scopus 로고
    • Determination of the rare-earth elements in geological-materials by inductively coupled plasma-mass spectrometry
    • Lichte F.E., Meier A.L., Crock J.G. Determination of the rare-earth elements in geological-materials by inductively coupled plasma-mass spectrometry. Analytical Chemistry 1987, 59:1150-1157.
    • (1987) Analytical Chemistry , vol.59 , pp. 1150-1157
    • Lichte, F.E.1    Meier, A.L.2    Crock, J.G.3
  • 50
    • 71149096283 scopus 로고    scopus 로고
    • Quadrupole ICP-MS: Introduction to instrumentation, measurement techniques and analytical capabilities
    • Linge K.L., Jarvis K.E. Quadrupole ICP-MS: Introduction to instrumentation, measurement techniques and analytical capabilities. Geostandards and Geoanalytical Research 2009, 33:445-467.
    • (2009) Geostandards and Geoanalytical Research , vol.33 , pp. 445-467
    • Linge, K.L.1    Jarvis, K.E.2
  • 51
    • 0000151143 scopus 로고    scopus 로고
    • A table of polyatomic interferences in ICP-MS
    • May T.W., Wiedmeyer R.H. A table of polyatomic interferences in ICP-MS. Atomic Spectroscopy 1998, 19:150-155.
    • (1998) Atomic Spectroscopy , vol.19 , pp. 150-155
    • May, T.W.1    Wiedmeyer, R.H.2
  • 52
    • 3042555345 scopus 로고    scopus 로고
    • The application of collision/reaction cell inductively coupled plasma mass spectrometry to multi-element analysis in variable sample matrices, using He as a non-reactive cell gas
    • Mccurdy E., Woods G. The application of collision/reaction cell inductively coupled plasma mass spectrometry to multi-element analysis in variable sample matrices, using He as a non-reactive cell gas. Journal of Analytical Atomic Spectrometry 2004, 19:607-615.
    • (2004) Journal of Analytical Atomic Spectrometry , vol.19 , pp. 607-615
    • Mccurdy, E.1    Woods, G.2
  • 53
    • 44849128637 scopus 로고    scopus 로고
    • The direct determination of rare earth elements in basaltic and related rocks using ICP-MS: Testing the efficiency of microwave oven sample decomposition procedures
    • Navarro M.S., Andrade S., Ulbrich H., Gomes C.B., Girardi V.A.V. The direct determination of rare earth elements in basaltic and related rocks using ICP-MS: Testing the efficiency of microwave oven sample decomposition procedures. Geostandards and Geoanalytical Research 2008, 32:167-180.
    • (2008) Geostandards and Geoanalytical Research , vol.32 , pp. 167-180
    • Navarro, M.S.1    Andrade, S.2    Ulbrich, H.3    Gomes, C.B.4    Girardi, V.A.V.5
  • 54
    • 83455212155 scopus 로고    scopus 로고
    • Effects of the sampling interface in MC-ICP-MS: Relative elemental sensitivities and non-linear mass dependent fractionation of Nd isotopes
    • Newman K. Effects of the sampling interface in MC-ICP-MS: Relative elemental sensitivities and non-linear mass dependent fractionation of Nd isotopes. Journal of Analytical Atomic Spectrometry 2012, 27:63-70.
    • (2012) Journal of Analytical Atomic Spectrometry , vol.27 , pp. 63-70
    • Newman, K.1
  • 55
    • 0031145355 scopus 로고    scopus 로고
    • Investigating the fate of individual sample droplets in inductively coupled plasmas
    • Olesik J.W. Investigating the fate of individual sample droplets in inductively coupled plasmas. Applied Spectroscopy 1997, 51:158A-175A.
    • (1997) Applied Spectroscopy , vol.51
    • Olesik, J.W.1
  • 56
    • 58149320463 scopus 로고
    • Characterization of aerosols produced by pneumatic nebulizers for inductively coupled plasma sample introduction: Effect of liquid and gas flow rates on volume based drop size distributions
    • Olesik J.W., Bates L.C. Characterization of aerosols produced by pneumatic nebulizers for inductively coupled plasma sample introduction: Effect of liquid and gas flow rates on volume based drop size distributions. Spectrochimica Acta Part B: Atomic Spectroscopy 1995, 50:285-303.
    • (1995) Spectrochimica Acta Part B: Atomic Spectroscopy , vol.50 , pp. 285-303
    • Olesik, J.W.1    Bates, L.C.2
  • 57
    • 0031147368 scopus 로고    scopus 로고
    • Observation of atom and ion clouds produced from single droplets of sample in inductively coupled plasmas by optical emission and laser-induced fluorescence imaging
    • Olesik J.W., Kinzer J.A., Mcgowan G.J. Observation of atom and ion clouds produced from single droplets of sample in inductively coupled plasmas by optical emission and laser-induced fluorescence imaging. Applied Spectroscopy 1997, 51:607-616.
    • (1997) Applied Spectroscopy , vol.51 , pp. 607-616
    • Olesik, J.W.1    Kinzer, J.A.2    Mcgowan, G.J.3
  • 58
    • 38349000899 scopus 로고    scopus 로고
    • Identification of a matrix effect in the MC-ICP-MS due to sample purification using ion exchange resin: An isotopic case study of molybdenum
    • Pietruszka A.J., Reznik A.D. Identification of a matrix effect in the MC-ICP-MS due to sample purification using ion exchange resin: An isotopic case study of molybdenum. International Journal of Mass Spectrometry 2008, 270:23-30.
    • (2008) International Journal of Mass Spectrometry , vol.270 , pp. 23-30
    • Pietruszka, A.J.1    Reznik, A.D.2
  • 59
    • 0041366121 scopus 로고    scopus 로고
    • Extending the capabilities of the thermodynamic simulation of thermochemical processes in inductively coupled plasma discharge
    • Pupyshev A.A., Lutsak A.K. Extending the capabilities of the thermodynamic simulation of thermochemical processes in inductively coupled plasma discharge. Journal of Analytical Chemistry 2002, 57:672-680.
    • (2002) Journal of Analytical Chemistry , vol.57 , pp. 672-680
    • Pupyshev, A.A.1    Lutsak, A.K.2
  • 61
    • 44649106562 scopus 로고    scopus 로고
    • Assessment of high precision, high accuracy inductively coupled plasma-optical emission spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations
    • Rabb S.A., Olesik J.W. Assessment of high precision, high accuracy inductively coupled plasma-optical emission spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations. Spectrochimica Acta Part B Atomic Spectroscopy 2008, 63:244-256.
    • (2008) Spectrochimica Acta Part B Atomic Spectroscopy , vol.63 , pp. 244-256
    • Rabb, S.A.1    Olesik, J.W.2
  • 62
    • 0028484368 scopus 로고
    • Characterization of polyatomic ion interferences in inductively coupled plasma mass spectrometry using a high resolution mass spectrometer
    • Reed N.M., Cairns R.O., Hutton R.C., Takaku Y. Characterization of polyatomic ion interferences in inductively coupled plasma mass spectrometry using a high resolution mass spectrometer. Journal of Analytical Atomic Spectrometry 1994, 9:881-896.
    • (1994) Journal of Analytical Atomic Spectrometry , vol.9 , pp. 881-896
    • Reed, N.M.1    Cairns, R.O.2    Hutton, R.C.3    Takaku, Y.4
  • 64
    • 2442478242 scopus 로고    scopus 로고
    • A model for the evaluation of uncertainty in routine multi-element analysis
    • Ruth T. A model for the evaluation of uncertainty in routine multi-element analysis. Accreditation and Quality Assurance 2004, 9:349-354.
    • (2004) Accreditation and Quality Assurance , vol.9 , pp. 349-354
    • Ruth, T.1
  • 65
    • 0032023005 scopus 로고    scopus 로고
    • Non-spectral interferences caused by a saline water matrix in quadrupole and high resolution inductively coupled plasma mass spectrometry
    • Ruth T., Klockare D. Non-spectral interferences caused by a saline water matrix in quadrupole and high resolution inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 1998, 13:159-166.
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , pp. 159-166
    • Ruth, T.1    Klockare, D.2
  • 66
    • 67649966603 scopus 로고    scopus 로고
    • Evaluation of a 512-Channel Faraday-strip array detector coupled to an inductively coupled plasma Mattauch-Herzog mass spectrograph
    • Schilling G.D., Ray S.J., Rubinshtein A.A., et al. Evaluation of a 512-Channel Faraday-strip array detector coupled to an inductively coupled plasma Mattauch-Herzog mass spectrograph. Analytical Chemistry 2009, 81:5467-5473.
    • (2009) Analytical Chemistry , vol.81 , pp. 5467-5473
    • Schilling, G.D.1    Ray, S.J.2    Rubinshtein, A.A.3
  • 67
    • 77649219922 scopus 로고    scopus 로고
    • Optimization of Ag isotope-ratio precision with a 128-Channel array detector coupled to a Mattauch-Herzog mass spectrograph
    • Schilling G.D., Ray S.J., Sperline R.P., et al. Optimization of Ag isotope-ratio precision with a 128-Channel array detector coupled to a Mattauch-Herzog mass spectrograph. Journal of Analytical Atomic Spectrometry 2010, 25:322-327.
    • (2010) Journal of Analytical Atomic Spectrometry , vol.25 , pp. 322-327
    • Schilling, G.D.1    Ray, S.J.2    Sperline, R.P.3
  • 68
    • 41349092030 scopus 로고    scopus 로고
    • The stable Cr isotope inventory of solid Earth reservoirs determined by double spike MC-ICP-MS
    • Schoenberg R., Zink S., Staubwasser M., Von Blanckenburg F. The stable Cr isotope inventory of solid Earth reservoirs determined by double spike MC-ICP-MS. Chemical Geology 2008, 249:294-306.
    • (2008) Chemical Geology , vol.249 , pp. 294-306
    • Schoenberg, R.1    Zink, S.2    Staubwasser, M.3    Von Blanckenburg, F.4
  • 69
    • 0003093605 scopus 로고
    • On-line coupling between chromatography and inductively coupled plasma mass spectrometry - A current assessment
    • Seubert A. On-line coupling between chromatography and inductively coupled plasma mass spectrometry - A current assessment. Fresenius' Journal of Analytical Chemistry 1994, 350:210-220.
    • (1994) Fresenius' Journal of Analytical Chemistry , vol.350 , pp. 210-220
    • Seubert, A.1
  • 71
    • 0002204069 scopus 로고
    • Matrix-effect observations in inductively coupled plasma mass spectrometry
    • Tan S.H., Horlick G. Matrix-effect observations in inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry 1987, 2:745-765.
    • (1987) Journal of Analytical Atomic Spectrometry , vol.2 , pp. 745-765
    • Tan, S.H.1    Horlick, G.2
  • 73
    • 0037072472 scopus 로고    scopus 로고
    • Reaction cells and collision cells for ICP-MS: A tutorial review
    • Tanner S.D., Baranov V.I., Bandura D.R. Reaction cells and collision cells for ICP-MS: A tutorial review. Spectrochimica Acta Part B 2002, 57:1361-1452.
    • (2002) Spectrochimica Acta Part B , vol.57 , pp. 1361-1452
    • Tanner, S.D.1    Baranov, V.I.2    Bandura, D.R.3
  • 74
    • 0028541311 scopus 로고
    • Reduction of space charge effects using a three-aperture gas dynamic vacuum interface for inductively coupled plasma-mass spectrometry
    • Tanner S.D., Cousins L.M., Douglas D.J. Reduction of space charge effects using a three-aperture gas dynamic vacuum interface for inductively coupled plasma-mass spectrometry. Applied Spectroscopy 1994, 48:1367-1372.
    • (1994) Applied Spectroscopy , vol.48 , pp. 1367-1372
    • Tanner, S.D.1    Cousins, L.M.2    Douglas, D.J.3
  • 75
    • 16844384703 scopus 로고    scopus 로고
    • A mass spectrometric study of glucose, sucrose, and fructose using an inductively coupled plasma and electrospray ionization
    • Taylor V.F., March R.E., Longerich H.P., Stadey C.J. A mass spectrometric study of glucose, sucrose, and fructose using an inductively coupled plasma and electrospray ionization. International Journal of Mass Spectrometry 2005, 243:71-84.
    • (2005) International Journal of Mass Spectrometry , vol.243 , pp. 71-84
    • Taylor, V.F.1    March, R.E.2    Longerich, H.P.3    Stadey, C.J.4
  • 76
    • 33646482715 scopus 로고    scopus 로고
    • Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS
    • Todolí J.L., Mermet J.M. Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS. Spectrochimica Acta Part B: Atomic Spectroscopy 2006, 61:239-283.
    • (2006) Spectrochimica Acta Part B: Atomic Spectroscopy , vol.61 , pp. 239-283
    • Todolí, J.L.1    Mermet, J.M.2
  • 77
    • 44849098460 scopus 로고    scopus 로고
    • Liquid sample introduction and electrothermal vaporisation for ICP-MS: Fundamentals and applications
    • Blackwell Publishing, Oxford, S. Nelms (Ed.)
    • Todoli J.L., Vanhaecke F. Liquid sample introduction and electrothermal vaporisation for ICP-MS: Fundamentals and applications. Inductively Coupled Plasma Mass Spectrometry Handbook 2005, Blackwell Publishing, Oxford. S. Nelms (Ed.).
    • (2005) Inductively Coupled Plasma Mass Spectrometry Handbook
    • Todoli, J.L.1    Vanhaecke, F.2
  • 78
    • 67649687115 scopus 로고    scopus 로고
    • Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis
    • Vanhaecke F., Balcaen L., Malinovsky D. Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis. Journal of Analytical Atomic Spectrometry 2009, 24:863-886.
    • (2009) Journal of Analytical Atomic Spectrometry , vol.24 , pp. 863-886
    • Vanhaecke, F.1    Balcaen, L.2    Malinovsky, D.3
  • 79
    • 0022716090 scopus 로고
    • Oxide, hydroxide, and doubly charged analyte species in inductively coupled plasma-mass spectrometry
    • Vaughan M.A., Horlick G. Oxide, hydroxide, and doubly charged analyte species in inductively coupled plasma-mass spectrometry. Applied Spectroscopy 1986, 40:434-445.
    • (1986) Applied Spectroscopy , vol.40 , pp. 434-445
    • Vaughan, M.A.1    Horlick, G.2
  • 81
    • 78651443366 scopus 로고    scopus 로고
    • GGR biennial review: Isotope ratio determination in the earth and environmental sciences 2008-2009
    • Woodhead J.D. GGR biennial review: Isotope ratio determination in the earth and environmental sciences 2008-2009. Geostandards and Geoanalytical Research 2010, 34:395-406.
    • (2010) Geostandards and Geoanalytical Research , vol.34 , pp. 395-406
    • Woodhead, J.D.1
  • 82
    • 70350519967 scopus 로고    scopus 로고
    • Accurate and precise determination of isotopic ratios by MC-ICP-MS: A review
    • Yang L. Accurate and precise determination of isotopic ratios by MC-ICP-MS: A review. Mass Spectrometry Reviews 2009, 28:990-1011.
    • (2009) Mass Spectrometry Reviews , vol.28 , pp. 990-1011
    • Yang, L.1
  • 83
    • 33745143543 scopus 로고    scopus 로고
    • An evaluation of methods for the chemical decomposition of geological materials for trace element determination using ICP-MS
    • Yu Z., Robinson P., Mcgoldrick P. An evaluation of methods for the chemical decomposition of geological materials for trace element determination using ICP-MS. Geostandards Newsletter 2001, 25:199-217.
    • (2001) Geostandards Newsletter , vol.25 , pp. 199-217
    • Yu, Z.1    Robinson, P.2    Mcgoldrick, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.