메뉴 건너뛰기




Volumn 24, Issue 7, 2009, Pages 863-886

Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis

Author keywords

[No Author keywords available]

Indexed keywords

APPLICATION RANGE; DEAD TIME EFFECTS; ICP-MASS SPECTROMETRY; ISOTOPE DILUTIONS; ISOTOPE FRACTIONATION; ISOTOPE RATIO; ISOTOPE-RATIO MEASUREMENTS; ISOTOPIC ANALYSIS; ISOTOPIC COMPOSITION; ISOTOPIC VARIATIONS; KINETIC ISOTOPE FRACTIONATION; LONG-LIVED RADIONUCLIDES; MASS DISCRIMINATION; MULTI-COLLECTOR; NATURAL VARIATION; NATURALLY OCCURRING; NUCLEAR APPLICATION; PHYSICAL PROCESS; PROVENANCE STUDIES; STABLE ISOTOPES; TARGET ELEMENT; TRACER EXPERIMENT;

EID: 67649687115     PISSN: 02679477     EISSN: 13645544     Source Type: Journal    
DOI: 10.1039/b903887f     Document Type: Review
Times cited : (143)

References (182)
  • 2
    • 85041149803 scopus 로고    scopus 로고
    • Cambridge University Press
    • nd ed., Cambridge University Press, 2005
    • (2005) nd Ed.
    • Dickin, A.P.1
  • 3
    • 0004286373 scopus 로고
    • John Wiley & Sons, New York
    • nd ed., John Wiley & Sons, New York, 1986
    • (1986) nd Ed.
    • Faure, G.1
  • 6
    • 0003673898 scopus 로고    scopus 로고
    • Springer-Verlag, Berlin
    • th ed., Springer-Verlag, Berlin, 2004
    • (2004) th Ed.
    • Hoefs, J.1
  • 46
    • 67649713666 scopus 로고    scopus 로고
    • Ph.D. Thesis, CRPG-CNRS, France
    • C. Cloquet, Ph.D. Thesis, CRPG-CNRS, France, 2005
    • (2005)
    • Cloquet, C.1
  • 50
    • 67649700647 scopus 로고    scopus 로고
    • http://georem.mpch-mainz.gwdg.de, last accessed 31.03.2009
  • 69
    • 0004247814 scopus 로고
    • F. Adams, R. Gijbels, R. van Grieken, Wiley, New York, pp. 301-376
    • K. G. Heumann in Inorganic mass spectrometry, ed., F. Adams, R. Gijbels, R. van Grieken, Wiley, New York, 1988, ch. 7, pp. 301-376
    • (1988) Inorganic Mass Spectrometry, Ed. , vol.7
    • Heumann In, K.G.1
  • 149
    • 33846138970 scopus 로고    scopus 로고
    • Authentication of Kalix (N.E. Sweden) vendace caviar using inductively coupled plasma-based analytical techniques: Evaluation of different approaches
    • DOI 10.1016/j.aca.2006.10.038, PII S0003267006021131
    • I. Rodushkin T. Bergman G. Douglas E. Engström D. Sörlin D. C. Baxter Authentication of Kalix (N.E. Sweden) vendace caviar using ICP-based analytical techniques: evaluation of different approaches Anal. Chim. Acta 2007 583 310 318 (Pubitemid 46080371)
    • (2007) Analytica Chimica Acta , vol.583 , Issue.2 , pp. 310-318
    • Rodushkin, I.1    Bergman, T.2    Douglas, G.3    Engstrom, E.4    Sorlin, D.5    Baxter, D.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.