메뉴 건너뛰기




Volumn 19, Issue 5, 1998, Pages 150-155

A Table of Polyatomic Interferences in ICP-MS

Author keywords

[No Author keywords available]

Indexed keywords


EID: 0000151143     PISSN: 01955373     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (467)

References (38)
  • 1
    • 0023135631 scopus 로고
    • Application of isotope dilution inductively coupled plasma masss spectrometry to the analysis of marine sediments
    • J.W. McLaren, D. Beauchemin, and S.S. Berman, "Application of isotope dilution inductively coupled plasma masss spectrometry to the analysis of marine sediments." Anal. Chem. 59 (4), 610-613 (1987).
    • (1987) Anal. Chem. , vol.59 , Issue.4 , pp. 610-613
    • McLaren, J.W.1    Beauchemin, D.2    Berman, S.S.3
  • 2
    • 0000494099 scopus 로고
    • Determination of trace elements in water by inductively coupled-plasma spectrometry: Collaborative study
    • J.E. Longbottom, T.D. Martin, K.W. Edgell, S.E. Long, M.R. Plantz, and B.E. Warden, "Determination of trace elements in water by inductively coupled-plasma spectrometry: collaborative study." J. AOAC 77 (4), 1004-1023 (1994).
    • (1994) J. AOAC , vol.77 , Issue.4 , pp. 1004-1023
    • Longbottom, J.E.1    Martin, T.D.2    Edgell, K.W.3    Long, S.E.4    Plantz, M.R.5    Warden, B.E.6
  • 3
    • 84972959038 scopus 로고
    • Electrothermal vaporization for sample introduction in plasma source spectrometry
    • J.M. Corey and J.A. Caruso, "Electrothermal vaporization for sample introduction in plasma source spectrometry. Critical reviews in Anal. Chem. 23 (5), 397-439 (1992).
    • (1992) Anal. Chem. , vol.23 , Issue.5 , pp. 397-439
    • Corey, J.M.1    Caruso, J.A.2
  • 4
    • 0023988426 scopus 로고
    • Determination of trace metals in marine biological reference materials by inductively coupled plasma mass spectrometiy
    • D. Beauchemin, J.W. McLauren, S.N. Willie, and S.S. Berman, "Determination of trace metals in marine biological reference materials by inductively coupled plasma mass spectrometiy." Anal. Chem. 60 (7); 687-691 (1988).
    • (1988) Anal. Chem. , vol.60 , Issue.7 , pp. 687-691
    • Beauchemin, D.1    McLauren, J.W.2    Willie, S.N.3    Berman, S.S.4
  • 5
    • 0042230560 scopus 로고
    • Effects of Ca on instrument stability in the trace element determination of Carich sous using ICP-MS
    • A. Stroh and U. Völlkopf, "Effects of Ca on instrument stability in the trace element determination of Carich sous using ICP-MS." At. Spectrosc. 14 (3); 76-79 (1993).
    • (1993) At. Spectrosc. , vol.14 , Issue.3 , pp. 76-79
    • Stroh, A.1    Völlkopf, U.2
  • 6
    • 0001663737 scopus 로고
    • Selective application of chemical separations to isotope dilution inductively coupled plasma mass spectrometric analyses of standard reference materials
    • E.S. Beary and P.J. Paulsen, "Selective application of chemical separations to isotope dilution inductively coupled plasma mass spectrometric analyses of standard reference materials." Anal. Chem. 65 (11); 1602-1608 (1993).
    • (1993) Anal. Chem. , vol.65 , Issue.11 , pp. 1602-1608
    • Beary, E.S.1    Paulsen, P.J.2
  • 7
    • 0000562195 scopus 로고
    • Characterization of trace elements in environmental samples by ICP-MS
    • V. Balaram, "Characterization of trace elements in environmental samples by ICP-MS." At. Spectrosc. 14 (6); 174-179 (1993).
    • (1993) At. Spectrosc. , vol.14 , Issue.6 , pp. 174-179
    • Balaram, V.1
  • 8
    • 37049076230 scopus 로고
    • On-line method for the analysis of sea-water for trace elements by inductively coupled plasma mass spectrometry
    • J.W. McLarean, J.W.H. Lam, S.S. Berman, K. Akatsuka, and M.A. Azeredo, "On-line method for the analysis of sea-water for trace elements by inductively coupled plasma mass spectrometry." J. Anal. At.. Spectrom. 8, pp 279-286 (1993).
    • (1993) J. Anal. At.. Spectrom. , vol.8 , pp. 279-286
    • McLarean, J.W.1    Lam, J.W.H.2    Berman, S.S.3    Akatsuka, K.4    Azeredo, M.A.5
  • 9
    • 0542399330 scopus 로고
    • Interferences in inductively coupled plasma mass spectrometry - A Review
    • H. Evans and J. Giglio, "Interferences in inductively coupled plasma mass spectrometry - A Review." J. Anal. At. Spectrom. 8, 1-18 (1993).
    • (1993) J. Anal. At. Spectrom. , vol.8 , pp. 1-18
    • Evans, H.1    Giglio, J.2
  • 10
    • 0000612081 scopus 로고
    • Determination of arsenic, chromium, selenium, and vanadium in biological samples by inductively coupled plasma mass spectrometry using on-line elimination of interference and preconcentration by flow injection
    • L. Ebdon, A. Fisher, and P. Worsfold, "Determination of arsenic, chromium, selenium, and vanadium in biological samples by inductively coupled plasma mass spectrometry using on-line elimination of interference and preconcentration by flow injection." J. Anal. At.. Spectrom. 9, 611-614 (1994).
    • (1994) J. Anal. At.. Spectrom. , vol.9 , pp. 611-614
    • Ebdon, L.1    Fisher, A.2    Worsfold, P.3
  • 11
    • 9844223117 scopus 로고
    • Inductively coupled plasma mass spectrometry of biological samples
    • C. Vandecasteele, H. Vanhoe, and R. Dams, "Inductively coupled plasma mass spectrometry of biological samples." J. Anal. At. Spectrom.. 8, 781-786 (1993).
    • (1993) J. Anal. At. Spectrom.. , vol.8 , pp. 781-786
    • Vandecasteele, C.1    Vanhoe, H.2    Dams, R.3
  • 12
    • 0000992907 scopus 로고
    • Determination of trace metals in concentrated brines using inductively coupled plasma mass spectrometry on-line preconcentration and matrix elimination with flow injection
    • L. Ebdon, A. Fisher, H. Handley, and P. Jones, "Determination of trace metals in concentrated brines using inductively coupled plasma mass spectrometry on-line preconcentration and matrix elimination with flow injection." J. Anal. At.. Spectrom. 8, 979-981 (1993).
    • (1993) J. Anal. At.. Spectrom. , vol.8 , pp. 979-981
    • Ebdon, L.1    Fisher, A.2    Handley, H.3    Jones, P.4
  • 13
    • 0028056289 scopus 로고
    • Use of inductively coupled plasma mass spectrometry for the determination of ultra-trace elements in human serum
    • H. Vanhoe and R. Dams, "Use of inductively coupled plasma mass spectrometry for the determination of ultra-trace elements in human serum." J. Anal. At.. Spectrom. 9, 23-31 (1994).
    • (1994) J. Anal. At.. Spectrom. , vol.9 , pp. 23-31
    • Vanhoe, H.1    Dams, R.2
  • 14
    • 37049074087 scopus 로고
    • Reduction of matrix effects and mass discrimination in inductively coupled plasma mass spectrometry with optimized argon-nitrogen plasmas
    • G. Xiao and D. Beauchemin, "Reduction of matrix effects and mass discrimination in inductively coupled plasma mass spectrometry with optimized argon-nitrogen plasmas." J. Anal. At.. Spectrom. 9, 509-518 (1994).
    • (1994) J. Anal. At.. Spectrom. , vol.9 , pp. 509-518
    • Xiao, G.1    Beauchemin, D.2
  • 15
    • 0001233338 scopus 로고
    • Anion exchange for the elimination of spectral interference caused by chlorine and sulfur in inductively coupled plasma mass spectrometry
    • J. Gossens and R. Dams, "Anion exchange for the elimination of spectral interference caused by chlorine and sulfur in inductively coupled plasma mass spectrometry." J. Anal. At. Spectrom. 7, 1167-1171 (1992).
    • (1992) J. Anal. At. Spectrom. , vol.7 , pp. 1167-1171
    • Gossens, J.1    Dams, R.2
  • 16
    • 0022360811 scopus 로고
    • Determination of trace metals in seawater by inductively coupled plasma mass spectrometry with preconcentration on silica-immobilized 8-hydroxyquinoline
    • S.S.
    • J.W. McLaren, A.P. Mykytiuk, S.N. Willie, and S.S. Berman, S.S. "Determination of trace metals in seawater by inductively coupled plasma mass spectrometry with preconcentration on silica-immobilized 8-hydroxyquinoline." Anal. Chem. 57, 2907-2911 (1985).
    • (1985) Anal. Chem. , vol.57 , pp. 2907-2911
    • McLaren, J.W.1    Mykytiuk, A.P.2    Willie, S.N.3    Berman, S.S.4
  • 17
    • 0001761877 scopus 로고
    • Determination of trace levels of metal ions in water samples by inductively coupled plasma mass spectrometry after on-line preconcentration on SO3-oxine cellulose
    • Kuang-Shie Huang and Shiuh-Jen Jiang.. "Determination of trace levels of metal ions in water samples by inductively coupled plasma mass spectrometry after on-line preconcentration on SO3-oxine cellulose." Fres. J. Anal. Chem. 347, 238-242 (1993).
    • (1993) Fres. J. Anal. Chem. , vol.347 , pp. 238-242
    • Huang, K.-S.1    Jiang, S.-J.2
  • 18
    • 0025891524 scopus 로고
    • Multielement analysis of biological samples by ICPMS II. Rapid survey method for profiling trace elements in body fluids
    • M-A. Vaughan, A.D. Baines, and D.M. Templeton, "Multielement analysis of biological samples by ICPMS II. Rapid survey method for profiling trace elements in body fluids." Clin. Chem. 37, 210-215 (1991).
    • (1991) Clin. Chem. , vol.37 , pp. 210-215
    • Vaughan, M.-A.1    Baines, A.D.2    Templeton, D.M.3
  • 19
    • 0027732893 scopus 로고
    • A review of the capabilities of ICP-MS for trace element analysis in body fluids and tissues
    • H. Vanhoe, "A review of the capabilities of ICP-MS for trace element analysis in body fluids and tissues." J. Trace Elem. Electrolytes Health Dis. 7, 131-139 (1993).
    • (1993) J. Trace Elem. Electrolytes Health Dis. , vol.7 , pp. 131-139
    • Vanhoe, H.1
  • 20
    • 0024578663 scopus 로고
    • Separation of trace metal complexes for analysis of samples of high salt content by inductively coupled plasma mass spectrometry
    • M.R. Plantz, J.S. Fritz, F.F. Smith, and R.S. Honk, "Separation of trace metal complexes for analysis of samples of high salt content by inductively coupled plasma mass spectrometry." Anal. Chem. 61, 149-153 (1989).
    • (1989) Anal. Chem. , vol.61 , pp. 149-153
    • Plantz, M.R.1    Fritz, J.S.2    Smith, F.F.3    Honk, R.S.4
  • 21
    • 0025239807 scopus 로고
    • Analysis of biological reference materials, prepared by microwave dissolution, using inductively coupled plasma mass spectrometry
    • J.K. Friel, C.S. Skinner, S.E. Jackson, and H.P. Longerich, "Analysis of biological reference materials, prepared by microwave dissolution, using inductively coupled plasma mass spectrometry." Analyst 115, 269-273 (1990).
    • (1990) Analyst , vol.115 , pp. 269-273
    • Friel, J.K.1    Skinner, C.S.2    Jackson, S.E.3    Longerich, H.P.4
  • 22
    • 0022709674 scopus 로고
    • Background spectral features in inductively coupled plasma/mass spectrometry
    • S.H. Tan and G. Horlick, "Background spectral features in inductively coupled plasma/mass spectrometry." Appl. Spectrosc. 40, 445-460 (1986).
    • (1986) Appl. Spectrosc. , vol.40 , pp. 445-460
    • Tan, S.H.1    Horlick, G.2
  • 23
    • 0002588575 scopus 로고
    • Ultratrace-level determination of rare earth elements, thorium, and uranium in ultramafic rocks by ICP-MS
    • A. Stroh, F. Bea, and P.O. Montero, "Ultratrace-level determination of rare earth elements, thorium, and uranium in ultramafic rocks by ICP-MS." At. Spectrosc. 1, 7-11 (1995).
    • (1995) At. Spectrosc. , vol.1 , pp. 7-11
    • Stroh, A.1    Bea, F.2    Montero, P.O.3
  • 24
    • 0345455743 scopus 로고
    • Rapid multielement analysis of urine
    • U. Völlkopf and K. Barnes, "Rapid multielement analysis of urine." At. Spectrosc. 16(1), 19-21 (1995).
    • (1995) At. Spectrosc. , vol.16 , Issue.1 , pp. 19-21
    • Völlkopf, U.1    Barnes, K.2
  • 25
    • 0028353084 scopus 로고
    • Isotope-specific analysis of Ni by ICP-MS: Applications of stable isotope tracers to biokinetic studies
    • D.M. Templeton, S.X. Xu, and L. Stuhne-Sekalee, "Isotope-specific analysis of Ni by ICP-MS: applications of stable isotope tracers to biokinetic studies." Science of Total Envir. 148, 253-262 (1994).
    • (1994) Science of Total Envir. , vol.148 , pp. 253-262
    • Templeton, D.M.1    Xu, S.X.2    Stuhne-Sekalee, L.3
  • 26
    • 0025629551 scopus 로고
    • Inductively coupled plasma-mass spectrometric analysis of geological samples: A critical evaluation based on case studies
    • H.P. Longerich, G.A. Jenner, B.J. Fryer, and S.E. Jackson, "Inductively coupled plasma-mass spectrometric analysis of geological samples: a critical evaluation based on case studies." Chem. Geol. 83, 105-118 (1990).
    • (1990) Chem. Geol. , vol.83 , pp. 105-118
    • Longerich, H.P.1    Jenner, G.A.2    Fryer, B.J.3    Jackson, S.E.4
  • 27
    • 0025658281 scopus 로고
    • ICP-MS - A powerful tool for high-precision trace-element analysis in earth sciences, evidence from analysis of selected U.S.G.S. reference samples
    • G.A. Jenner, H.P. Longerich, S.E. Jackson, and B.J. Fryer, "ICP-MS - a powerful tool for high-precision trace-element analysis in earth sciences, evidence from analysis of selected U.S.G.S. reference samples." Chem. Geol. 83, 133-148 (1990).
    • (1990) Chem. Geol. , vol.83 , pp. 133-148
    • Jenner, G.A.1    Longerich, H.P.2    Jackson, S.E.3    Fryer, B.J.4
  • 28
    • 0028747752 scopus 로고
    • Sample preparation approaches for isotope dilution inductively coupled plasma mass spectrometric certification of reference materials
    • E.S. Beary, P.J. Paulsen, and J.D. Fassett, "Sample preparation approaches for isotope dilution inductively coupled plasma mass spectrometric certification of reference materials." J. Anal. At. Spectrom. 9, 1363-1369 (1994).
    • (1994) J. Anal. At. Spectrom. , vol.9 , pp. 1363-1369
    • Beary, E.S.1    Paulsen, P.J.2    Fassett, J.D.3
  • 29
    • 0028484368 scopus 로고
    • Characterization of polyatomic ion interferences in inductively coupled plasma mass spectrometry using a high resolution mass spectrometer
    • N.M. Reed, R.O. Cairns, and R.C. Hutton, "Characterization of polyatomic ion interferences in inductively coupled plasma mass spectrometry using a high resolution mass spectrometer." J Anal. At. Specrom. 9, 88-896 (1994).
    • (1994) J Anal. At. Specrom. , vol.9 , pp. 88-896
    • Reed, N.M.1    Cairns, R.O.2    Hutton, R.C.3
  • 30
    • 0028497402 scopus 로고
    • Reduction of some selected spectral interferences in inductively coupled plasma mass spectrometry
    • W. Tittes, N. Jakubowski, D. Stuwer, and G. Tolg," Reduction of some selected spectral interferences in inductively coupled plasma mass spectrometry." J. Anal. At.. Spectrom. 9, 1015-1020 (1994).
    • (1994) J. Anal. At.. Spectrom. , vol.9 , pp. 1015-1020
    • Tittes, W.1    Jakubowski, N.2    Stuwer, D.3    Tolg, G.4
  • 31
    • 0000734621 scopus 로고
    • Silicon determination in steel by ICP-MS
    • H. Kuss, D. Bossmann, and M. Muller, M. "Silicon determination in steel by ICP-MS." At.. Spectrosc. July/Aug, 148-150 (1994).
    • (1994) At.. Spectrosc. , vol.JULY-AUG , pp. 148-150
    • Kuss, H.1    Bossmann, D.2    Muller M, M.3
  • 32
    • 0001125647 scopus 로고
    • The analysis of high-purity noble metals and their salts by ICP-MS
    • S.M. Graham and R.V.O. Robert, "The analysis of high-purity noble metals and their salts by ICP-MS." Talanta 41 (8), 1369-1375 (1994).
    • (1994) Talanta , vol.41 , Issue.8 , pp. 1369-1375
    • Graham, S.M.1    Robert, R.V.O.2
  • 33
    • 0028731732 scopus 로고
    • Determination of total arsenic concentrations in biological matrices by inductively coupled plasma mass spectrometry
    • M.J. Campbell, C. Demesmay, and M. Olle, "Determination of total arsenic concentrations in biological matrices by inductively coupled plasma mass spectrometry." J. Anal. At. Spectrom. 9, 1379-1384 (1994).
    • (1994) J. Anal. At. Spectrom. , vol.9 , pp. 1379-1384
    • Campbell, M.J.1    Demesmay, C.2    Olle, M.3
  • 34
    • 0028449547 scopus 로고
    • Signal enhancement and reduction of interferences in inductively coupled plasma mass spectrometry with an argon-trifluoromethane mixed aerosol carrier gas
    • I. Platzner, J.V. Sala, F. Mousty, P.R. Trincherini, and A.L. Polettini, "Signal enhancement and reduction of interferences in inductively coupled plasma mass spectrometry with an argon-trifluoromethane mixed aerosol carrier gas." J. Anal. At. Spectrom. 9, 719-726 (1994).
    • (1994) J. Anal. At. Spectrom. , vol.9 , pp. 719-726
    • Platzner, I.1    Sala, J.V.2    Mousty, F.3    Trincherini, P.R.4    Polettini, A.L.5
  • 35
    • 0028446368 scopus 로고
    • Reduction of polyatomic interferences in inductively coupled plasma mass spectrometry by selection of instrumental parameters and using an argon-nitrogen plasma: Effect on multi-element analyses
    • F. Laborda, M.J. Baxter, H.M. Crews, and J. Dennis, "Reduction of polyatomic interferences in inductively coupled plasma mass spectrometry by selection of instrumental parameters and using an argon-nitrogen plasma: Effect on multi-element analyses." J. Anal. At. Spectrom. 9, 727-736 (1994).
    • (1994) J. Anal. At. Spectrom. , vol.9 , pp. 727-736
    • Laborda, F.1    Baxter, M.J.2    Crews, H.M.3    Dennis, J.4
  • 36
    • 0542361803 scopus 로고
    • The Perkin-Elmer Corporation, Norwalk, CT USA
    • ELAN 6000 Training Manual, The Perkin-Elmer Corporation, Norwalk, CT USA, pp 1-11 (1995).
    • (1995) ELAN 6000 Training Manual , pp. 1-11
  • 37
    • 0030736693 scopus 로고    scopus 로고
    • Simultaneous determination of aluminum, titanium, vanadium in serum by electrothermal vaporization-inductively coupled plasma mass spectrometry
    • L. Yu, R. Koirtyohann, M. Rueppel, A. Skipor, and J. Jacobs, "Simultaneous determination of aluminum, titanium, vanadium in serum by electrothermal vaporization-inductively coupled plasma mass spectrometry." J. Anal. At. Spectrom. 1, 69-74 (1997).
    • (1997) J. Anal. At. Spectrom. , vol.1 , pp. 69-74
    • Yu, L.1    Koirtyohann, R.2    Rueppel, M.3    Skipor, A.4    Jacobs, J.5
  • 38
    • 0000076238 scopus 로고    scopus 로고
    • The determination of rare earth elements in soil by inductively coupled plasma mass spectrometry
    • Zhang Shuzhan and Shan Xiaoquan. "The determination of rare earth elements in soil by inductively coupled plasma mass spectrometry." At. Spectrosc. 18 (5), 140-144 (1997).
    • (1997) At. Spectrosc. , vol.18 , Issue.5 , pp. 140-144
    • Shuzhan, Z.1    Xiaoquan, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.