메뉴 건너뛰기




Volumn 63, Issue 2, 2008, Pages 244-256

Assessment of high precision, high accuracy Inductively Coupled Plasma-Optical Emission Spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations

Author keywords

Chemical matrix effects; High accuracy; High precision; ICP OES

Indexed keywords

CONCENTRATION (PROCESS); GEOLOGY; OPTICAL EMISSION SPECTROSCOPY; OPTIMIZATION; UNCERTAINTY ANALYSIS;

EID: 44649106562     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2007.11.034     Document Type: Article
Times cited : (16)

References (42)
  • 1
    • 0028529264 scopus 로고
    • Quality of calibration in inductively coupled plasma atomic emission spectrometry
    • Mermet J.-M. Quality of calibration in inductively coupled plasma atomic emission spectrometry. Spectrochim. Acta Part B 49 (1994) 1313-1324
    • (1994) Spectrochim. Acta Part B , vol.49 , pp. 1313-1324
    • Mermet, J.-M.1
  • 2
    • 0001693709 scopus 로고    scopus 로고
    • A drift correction procedure
    • Salit M.L., and Turk G.C. A drift correction procedure. Anal. Chem. 70 (1998) 3184-3190
    • (1998) Anal. Chem. , vol.70 , pp. 3184-3190
    • Salit, M.L.1    Turk, G.C.2
  • 4
    • 0035886975 scopus 로고    scopus 로고
    • Single-element solution comparisons with a high-performance inductively coupled plasma optical emission spectrometric method
    • Salit M.L., Turk G.C., Lindstrom A.P., Butler T.A., Beck C.M., and Norman B. Single-element solution comparisons with a high-performance inductively coupled plasma optical emission spectrometric method. Anal. Chem. 73 (2001) 4821-4829
    • (2001) Anal. Chem. , vol.73 , pp. 4821-4829
    • Salit, M.L.1    Turk, G.C.2    Lindstrom, A.P.3    Butler, T.A.4    Beck, C.M.5    Norman, B.6
  • 5
  • 6
    • 33645517613 scopus 로고    scopus 로고
    • High- accuracy determination of epitaxial AlGaAs composition with inductively coupled plasma optical emission spectroscopy
    • Bertness K.A., Wang C.M., Salit M.L., Turk G.C., Butler T.A., Paul A.J., and Robins L.H. High- accuracy determination of epitaxial AlGaAs composition with inductively coupled plasma optical emission spectroscopy. J. Vac. Sci. Technol., B 24 (2006) 762-767
    • (2006) J. Vac. Sci. Technol., B , vol.24 , pp. 762-767
    • Bertness, K.A.1    Wang, C.M.2    Salit, M.L.3    Turk, G.C.4    Butler, T.A.5    Paul, A.J.6    Robins, L.H.7
  • 7
    • 0001664162 scopus 로고    scopus 로고
    • Compensation of Ca and Na interference effects in axially and radially viewed inductively coupled plasmas
    • Brenner I.B., Le Marchand A., Daraed C., and Chauvet L. Compensation of Ca and Na interference effects in axially and radially viewed inductively coupled plasmas. Microchem. J. 63 (1999) 344-355
    • (1999) Microchem. J. , vol.63 , pp. 344-355
    • Brenner, I.B.1    Le Marchand, A.2    Daraed, C.3    Chauvet, L.4
  • 8
    • 0001664720 scopus 로고    scopus 로고
    • Axially and radially viewed inductively coupled plasmas - a critical review
    • Brenner I.B., and Zander A.T. Axially and radially viewed inductively coupled plasmas - a critical review. Spectrochim. Acta Part B 55 (2000) 1195-1240
    • (2000) Spectrochim. Acta Part B , vol.55 , pp. 1195-1240
    • Brenner, I.B.1    Zander, A.T.2
  • 9
    • 0001457378 scopus 로고
    • Multielement characterization of soil samples with ICP-MS for environmental studies
    • Arunachalam J., Mohl C., Ostapczuk P., and Emons H. Multielement characterization of soil samples with ICP-MS for environmental studies. Fresenius' J. Anal. Chem. 352 (1995) 577-581
    • (1995) Fresenius' J. Anal. Chem. , vol.352 , pp. 577-581
    • Arunachalam, J.1    Mohl, C.2    Ostapczuk, P.3    Emons, H.4
  • 10
    • 0001684959 scopus 로고    scopus 로고
    • Comparison of procedures for correction of matrix interferences in the multi-element analysis of soils by ICP-AES with a CCD detection system
    • Sadler D.A., Sun F., Howe S.E., and Littlejohn D. Comparison of procedures for correction of matrix interferences in the multi-element analysis of soils by ICP-AES with a CCD detection system. Mikrochim. Acta 126 (1997) 301-311
    • (1997) Mikrochim. Acta , vol.126 , pp. 301-311
    • Sadler, D.A.1    Sun, F.2    Howe, S.E.3    Littlejohn, D.4
  • 11
    • 34250076216 scopus 로고
    • Nonlinear spectral interferences in an inductively-coupled plasma optimized for simultaneous multielement analysis of plant and soil samples by atomic-emission spectrometry
    • Vuchkova L., and Arpadjan S. Nonlinear spectral interferences in an inductively-coupled plasma optimized for simultaneous multielement analysis of plant and soil samples by atomic-emission spectrometry. Fresenius' J. Anal. Chem. 347 (1993) 495-498
    • (1993) Fresenius' J. Anal. Chem. , vol.347 , pp. 495-498
    • Vuchkova, L.1    Arpadjan, S.2
  • 14
    • 44649169352 scopus 로고    scopus 로고
    • S.J. Hill, Inductively coupled plasma spectrometry and its applications, Sheffield Academic Press, CRC Press, London, Boca Raton, FL, 1999.
    • S.J. Hill, Inductively coupled plasma spectrometry and its applications, Sheffield Academic Press, CRC Press, London, Boca Raton, FL, 1999.
  • 15
    • 0032203931 scopus 로고    scopus 로고
    • Comparison of ionic line-based internal standardization with axially and radially viewed inductively coupled plasma atomic emission spectrometry to compensate for sodium effects on accuracy
    • Dubuisson C., Poussel E., and Mermet J.M. Comparison of ionic line-based internal standardization with axially and radially viewed inductively coupled plasma atomic emission spectrometry to compensate for sodium effects on accuracy. J. Anal. At. Spectrom. 13 (1998) 1265-1269
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 1265-1269
    • Dubuisson, C.1    Poussel, E.2    Mermet, J.M.3
  • 16
    • 0030357072 scopus 로고    scopus 로고
    • Empirical procedure for the reduction of mixed-matrix effects in inductively coupled plasma atomic emission spectrometry using an internal standard and proportional correction
    • de Boer J.L.M., and Velterop M. Empirical procedure for the reduction of mixed-matrix effects in inductively coupled plasma atomic emission spectrometry using an internal standard and proportional correction. Fresenius' J. Anal. Chem. 356 (1996) 362-370
    • (1996) Fresenius' J. Anal. Chem. , vol.356 , pp. 362-370
    • de Boer, J.L.M.1    Velterop, M.2
  • 17
    • 0032678929 scopus 로고    scopus 로고
    • On the use of line intensity ratios and power adjustments to control matrix effects in inductively coupled plasma optical emission spectrometry
    • van Veen E.H., and de Loos-Vollebregt M.T.C. On the use of line intensity ratios and power adjustments to control matrix effects in inductively coupled plasma optical emission spectrometry. J. Anal. At. Spectrom. 14 (1999) 831-838
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 831-838
    • van Veen, E.H.1    de Loos-Vollebregt, M.T.C.2
  • 18
    • 0020289051 scopus 로고
    • Inductively coupled plasma emission-spectrometry with internal standardization and subtraction of plasma background fluctuations
    • Schmidt G.J., and Slavin W. Inductively coupled plasma emission-spectrometry with internal standardization and subtraction of plasma background fluctuations. Anal. Chem. 54 (1982) 2491-2495
    • (1982) Anal. Chem. , vol.54 , pp. 2491-2495
    • Schmidt, G.J.1    Slavin, W.2
  • 19
    • 0000372404 scopus 로고
    • Matrix effects due to calcium in inductively coupled plasma atomic- emission spectrometry - their nature, source and remedy
    • Thompson M., and Ramsey M.H. Matrix effects due to calcium in inductively coupled plasma atomic- emission spectrometry - their nature, source and remedy. Analyst 110 (1985) 1413-1422
    • (1985) Analyst , vol.110 , pp. 1413-1422
    • Thompson, M.1    Ramsey, M.H.2
  • 20
    • 44649113347 scopus 로고    scopus 로고
    • E.J. Williamsen, Fundamental studies of matrix effects in the inductively coupled plasma by spatially resolved emission and fluorescence spectroscopy, Ph. Thesis, Department of Chemistry, University of North Carolina, 1990.
    • E.J. Williamsen, Fundamental studies of matrix effects in the inductively coupled plasma by spatially resolved emission and fluorescence spectroscopy, Ph. Thesis, Department of Chemistry, University of North Carolina, 1990.
  • 21
    • 0028377894 scopus 로고
    • The effect of easily ionized elements on analyte emission efficiency in inductively-coupled plasma spectrometry
    • Wu M., and Hieftje G.M. The effect of easily ionized elements on analyte emission efficiency in inductively-coupled plasma spectrometry. Spectrochim. Acta Part B 49 (1994) 149-161
    • (1994) Spectrochim. Acta Part B , vol.49 , pp. 149-161
    • Wu, M.1    Hieftje, G.M.2
  • 22
    • 0024731477 scopus 로고
    • Easily and noneasily ionizable element matrix effects in Inductively Coupled Plasma Optical Spectrometry
    • Olesik J.W., and Williamsen E.J. Easily and noneasily ionizable element matrix effects in Inductively Coupled Plasma Optical Spectrometry. Appl. Spectrosc. 43 (1989) 1223-1232
    • (1989) Appl. Spectrosc. , vol.43 , pp. 1223-1232
    • Olesik, J.W.1    Williamsen, E.J.2
  • 23
    • 0035862077 scopus 로고    scopus 로고
    • Study of ionic-to-atomic line intensity ratios for two axial viewing-based inductively coupled plasma atomic emission spectrometers
    • Dennaud J., Howes A., Poussel E., and Mermet J.M. Study of ionic-to-atomic line intensity ratios for two axial viewing-based inductively coupled plasma atomic emission spectrometers. Spectrochim. Acta Part B 56 (2001) 101-112
    • (2001) Spectrochim. Acta Part B , vol.56 , pp. 101-112
    • Dennaud, J.1    Howes, A.2    Poussel, E.3    Mermet, J.M.4
  • 24
    • 0025821084 scopus 로고
    • Use of magnesium as a test element for inductively coupled plasma atomic emission spectrometry diagnostics
    • Mermet J.M. Use of magnesium as a test element for inductively coupled plasma atomic emission spectrometry diagnostics. Anal. Chim. Acta 250 (1991) 85-94
    • (1991) Anal. Chim. Acta , vol.250 , pp. 85-94
    • Mermet, J.M.1
  • 25
    • 0024775164 scopus 로고
    • Ionic to atomic line intensity ratio and residence time in inductively coupled plasma-atomic emission spectrometry
    • Mermet J.M. Ionic to atomic line intensity ratio and residence time in inductively coupled plasma-atomic emission spectrometry. Spectrochim. Acta Part B 44 (1989) 1109-1116
    • (1989) Spectrochim. Acta Part B , vol.44 , pp. 1109-1116
    • Mermet, J.M.1
  • 26
    • 0031646291 scopus 로고    scopus 로고
    • Comparison of the effect of acetic acid with axially and radially viewed inductively coupled plasma atomic emission spectrometry: influence of the operating conditions
    • Dubuisson C., Poussel E., Mermet J.M., and Todoli J.L. Comparison of the effect of acetic acid with axially and radially viewed inductively coupled plasma atomic emission spectrometry: influence of the operating conditions. J. Anal. At. Spectrom. 13 (1998) 63-67
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 63-67
    • Dubuisson, C.1    Poussel, E.2    Mermet, J.M.3    Todoli, J.L.4
  • 27
    • 0000656423 scopus 로고
    • Improved precision in inductively coupled plasma atomic-emission spectrometry by a parameter-related internal standard method
    • Ramsey M.H., and Thompson M. Improved precision in inductively coupled plasma atomic-emission spectrometry by a parameter-related internal standard method. Analyst 109 (1984) 1625-1626
    • (1984) Analyst , vol.109 , pp. 1625-1626
    • Ramsey, M.H.1    Thompson, M.2
  • 28
    • 0000338858 scopus 로고    scopus 로고
    • The determination of chromium, copper and nickel in groundwater using axial plasma inductively coupled plasma atomic emission spectrometry and proportional correction matrix effect reduction
    • de Boer J.L.M., van Leeuwen W., Kohlmeyer U., and Breugem P.M. The determination of chromium, copper and nickel in groundwater using axial plasma inductively coupled plasma atomic emission spectrometry and proportional correction matrix effect reduction. Fresenius' J. Anal. Chem. 360 (1998) 213-218
    • (1998) Fresenius' J. Anal. Chem. , vol.360 , pp. 213-218
    • de Boer, J.L.M.1    van Leeuwen, W.2    Kohlmeyer, U.3    Breugem, P.M.4
  • 29
    • 0032475686 scopus 로고    scopus 로고
    • Correction for non-spectroscopic matrix effects in inductively coupled plasma-atomic emission spectroscopy by internal standardization using spectral lines of the same analyte
    • Al-Ammar A.S., and Barnes R.M. Correction for non-spectroscopic matrix effects in inductively coupled plasma-atomic emission spectroscopy by internal standardization using spectral lines of the same analyte. Spectrochim. Acta Part B 53 (1998) 1583-1593
    • (1998) Spectrochim. Acta Part B , vol.53 , pp. 1583-1593
    • Al-Ammar, A.S.1    Barnes, R.M.2
  • 30
    • 0002167741 scopus 로고    scopus 로고
    • Correction for drift in ICP-OES measurements by internal standardization using spectral lines of the same analyte as internal reference
    • Al-Ammar A.S., and Barnes R.M. Correction for drift in ICP-OES measurements by internal standardization using spectral lines of the same analyte as internal reference. At. Spectr. 19 (1998) 18-22
    • (1998) At. Spectr. , vol.19 , pp. 18-22
    • Al-Ammar, A.S.1    Barnes, R.M.2
  • 31
    • 0000386723 scopus 로고
    • Design and evaluation of an echelle grating optical system for ICP-OES
    • Barnard T.W., Crockett M.I., Ivaldi J.C., and Lundberg P.L. Design and evaluation of an echelle grating optical system for ICP-OES. Anal. Chem. 65 (1993) 1225-1230
    • (1993) Anal. Chem. , vol.65 , pp. 1225-1230
    • Barnard, T.W.1    Crockett, M.I.2    Ivaldi, J.C.3    Lundberg, P.L.4
  • 34
    • 44649155962 scopus 로고    scopus 로고
    • J.E. Sansonetti, W.C. Martin, S.L. Young, Handbook of Basic Atomic Spectroscopic Data (Version 1.1.2) (2005) [Online] Available: http://physics.nist.gov/PhysRefData/Handbook/index.html [2008, January 2], National Institute of Standards and Technology, Gaithersburg, MD.
    • J.E. Sansonetti, W.C. Martin, S.L. Young, Handbook of Basic Atomic Spectroscopic Data (Version 1.1.2) (2005) [Online] Available: http://physics.nist.gov/PhysRefData/Handbook/index.html [2008, January 2], National Institute of Standards and Technology, Gaithersburg, MD.
  • 35
    • 44649111492 scopus 로고    scopus 로고
    • K.P. Jochum, GeoReM: Geological and Reference Materials (2007), http://georem.mpch-mainz.gwdg.de/
    • K.P. Jochum, GeoReM: Geological and Reference Materials (2007), http://georem.mpch-mainz.gwdg.de/
  • 37
    • 0001776974 scopus 로고
    • Isotope-Dilution Mass-Spectrometry (ID-MS) of the elements
    • Heumann K.G. Isotope-Dilution Mass-Spectrometry (ID-MS) of the elements. Mass Spectrom. Rev. 11 (1992) 41-67
    • (1992) Mass Spectrom. Rev. , vol.11 , pp. 41-67
    • Heumann, K.G.1
  • 38
    • 2942535804 scopus 로고    scopus 로고
    • Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?
    • Heumann K.G. Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?. Anal. Bioanal. Chem. 378 (2004) 318-329
    • (2004) Anal. Bioanal. Chem. , vol.378 , pp. 318-329
    • Heumann, K.G.1
  • 39
    • 34250825213 scopus 로고    scopus 로고
    • Characterisation of reference materials by isotope dilution mass spectrometry
    • Vogl J. Characterisation of reference materials by isotope dilution mass spectrometry. J. Anal. At. Spectrom. 22 (2007) 475-492
    • (2007) J. Anal. At. Spectrom. , vol.22 , pp. 475-492
    • Vogl, J.1
  • 41
    • 33947138047 scopus 로고    scopus 로고
    • Determination of major, minor and trace elements in silicate samples by ICP-QMS and ICP-SFMS applying isotope dilution-internal standardisation (ID-IS) and multi-stage internal standardisation
    • Makishima A., and Nakamura E. Determination of major, minor and trace elements in silicate samples by ICP-QMS and ICP-SFMS applying isotope dilution-internal standardisation (ID-IS) and multi-stage internal standardisation. Geostand. Geoanal. Res. 30 (2006) 245-271
    • (2006) Geostand. Geoanal. Res. , vol.30 , pp. 245-271
    • Makishima, A.1    Nakamura, E.2
  • 42
    • 0037328290 scopus 로고    scopus 로고
    • Precise determination of Rb, Sr, Ba, and Pb in geological materials by isotope dilution and ICP-quadrupole mass spectrometry following selective separation of the analytes
    • Pin C., Joannon S., Bosq C., Le Fevre B., and Gauthier P.J. Precise determination of Rb, Sr, Ba, and Pb in geological materials by isotope dilution and ICP-quadrupole mass spectrometry following selective separation of the analytes. J. Anal. At. Spectrom. 18 (2003) 135-141
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 135-141
    • Pin, C.1    Joannon, S.2    Bosq, C.3    Le Fevre, B.4    Gauthier, P.J.5