메뉴 건너뛰기




Volumn 25, Issue 6, 2014, Pages 1599-1612

Biological activity and migration of wear particles in the knee joint: An in vivo comparison of six different polyethylene materials

Author keywords

[No Author keywords available]

Indexed keywords

ALIPHATIC COMPOUNDS; ARTHROPLASTY; BIOACTIVITY; BONE; CARTILAGE; KNEE PROSTHESES; MAMMALS; POLYETHYLENES; SUSPENSIONS (FLUIDS); TISSUE; WEAR OF MATERIALS;

EID: 84903710497     PISSN: 09574530     EISSN: 15734838     Source Type: Journal    
DOI: 10.1007/s10856-014-5176-6     Document Type: Article
Times cited : (13)

References (53)
  • 3
    • 2342495274 scopus 로고    scopus 로고
    • alpha-Tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear
    • DOI 10.1016/j.biomaterials.2003.12.048, PII S0142961203012201
    • Oral E, Wannomae KK, Hawkins N, Harris WH, Muratoglu OK. Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials. 2004;25(24):5515-22. doi:10.1016/j.biomaterials.2003.12.048. (Pubitemid 38610190)
    • (2004) Biomaterials , vol.25 , Issue.24 , pp. 5515-5522
    • Oral, E.1    Wannomae, K.K.2    Hawkins, N.3    Harris, W.H.4    Muratoglu, O.K.5
  • 6
    • 41149115986 scopus 로고    scopus 로고
    • Chondrocyte acting as phagocyte to internalize polyethylene wear particles and leads to the elevations of osteoarthritis associated NO and PGE2
    • doi:10.1016/j.bbrc.2008.02.123
    • Chang CH, Fang HW, Ho YC, Huang HT. Chondrocyte acting as phagocyte to internalize polyethylene wear particles and leads to the elevations of osteoarthritis associated NO and PGE2. Biochem Biophys Res Commun. 2008;369(3):884-8. doi:10.1016/j.bbrc.2008.02.123.
    • (2008) Biochem Biophys Res Commun , vol.369 , Issue.3 , pp. 884-888
    • Chang, C.H.1    Fang, H.W.2    Ho, Y.C.3    Huang, H.T.4
  • 7
    • 4744340427 scopus 로고    scopus 로고
    • A new role for chondrocytes as non-professional phagocytes. An in vitro study
    • DOI 10.1002/jemt.20080
    • Castillo EC, Kouri JB. A new role for chondrocytes as non-professional phagocytes. An in vitro study. Microsc Res Tech. 2004;64(3):269-78. doi:10.1002/jemt.20080. (Pubitemid 39313873)
    • (2004) Microscopy Research and Technique , vol.64 , Issue.3 , pp. 269-278
    • Gonzalez, C.E.C.1    Kouri, J.B.2
  • 9
    • 67649443043 scopus 로고    scopus 로고
    • Wear of contemporary total knee replacements: A knee simulator study of six current designs
    • doi:10.1016/j.clinbiomech.2009.04.007
    • Utzschneider S, Harrasser N, Schroeder C, Mazoochian F, Jansson V. Wear of contemporary total knee replacements: a knee simulator study of six current designs. Clin Biomech. 2009;24(7):583-8. doi:10.1016/j.clinbiomech.2009.04.007.
    • (2009) Clin Biomech , vol.24 , Issue.7 , pp. 583-588
    • Utzschneider, S.1    Harrasser, N.2    Schroeder, C.3    Mazoochian, F.4    Jansson, V.5
  • 10
    • 0035003313 scopus 로고    scopus 로고
    • Comparison of three joint simulator wear debris isolation techniques: Acid digestion, base digestion, and enzyme cleavage
    • DOI 10.1002/1097-4636(200108)56:2<245::AID-JBM1091
    • Niedzwiecki S, Klapperich C, Short J, Jani S, Ries M, Pruitt L. Comparison of three joint simulator wear debris isolation techniques: acid digestion, base digestion, and enzyme cleavage. J Biomed Mater Res. 2001;56(2):245-9. (Pubitemid 32520700)
    • (2001) Journal of Biomedical Materials Research , vol.56 , Issue.2 , pp. 245-249
    • Niedzwiecki, S.1    Klapperich, C.2    Short, J.3    Jani, S.4    Ries, M.5    Pruitt, L.6
  • 12
    • 68949098510 scopus 로고    scopus 로고
    • Influence of design and bearing material on polyethylene wear particle generation in total knee replacement
    • doi:10.1016/j.actbio.2009.03.016
    • Utzschneider S, Paulus A, Datz JC, Schroeder C, Sievers B, Wegener B, et al. Influence of design and bearing material on polyethylene wear particle generation in total knee replacement. Acta Biomater. 2009;5(7):2495-502. doi:10.1016/j.actbio.2009.03.016.
    • (2009) Acta Biomater , vol.5 , Issue.7 , pp. 2495-2502
    • Utzschneider, S.1    Paulus, A.2    Datz, J.C.3    Schroeder, C.4    Sievers, B.5    Wegener, B.6
  • 13
    • 84866856695 scopus 로고    scopus 로고
    • Evaluation of different methods to eliminate adherent endotoxin of polyethylene wear particles
    • Paulus A, Schröder C, Sievers B, Frenzel J, Jansson V, Utzschneider S. Evaluation of different methods to eliminate adherent endotoxin of polyethylene wear particles. Wear. 2012;295:319-25.
    • (2012) Wear , vol.295 , pp. 319-325
    • Paulus, A.1    Schröder, C.2    Sievers, B.3    Frenzel, J.4    Jansson, V.5    Utzschneider, S.6
  • 14
    • 0035110245 scopus 로고    scopus 로고
    • The effects of particulate wear debris, cytokines, and growth factors on the functions of MG-63 osteoblasts
    • Vol.
    • Vermes C, Chandrasekaran R, Jacobs JJ, Galante JO, Roebuck KA, Glant TT. The effects of particulate wear debris, cytokines, and growth factors on the functions of MG-63 osteoblasts. J Bone Joint Surg Am Vol. 2001;83(A(2)):201-11.
    • (2001) J Bone Joint Surg Am , vol.83 , Issue.2 A , pp. 201-211
    • Vermes, C.1    Chandrasekaran, R.2    Jacobs, J.J.3    Galante, J.O.4    Roebuck, K.A.5    Glant, T.T.6
  • 17
    • 0032401792 scopus 로고    scopus 로고
    • Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro
    • PII S0142961298001409
    • Green TR, Fisher J, Stone M, Wroblewski BM, Ingham E. Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 1998;19(24):2297-302. (Pubitemid 28550396)
    • (1998) Biomaterials , vol.19 , Issue.24 , pp. 2297-2302
    • Green, T.R.1    Fisher, J.2    Stone, M.3    Wroblewski, B.M.4    Ingham, E.5
  • 18
    • 0033638364 scopus 로고    scopus 로고
    • Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles
    • Matthews JB, Green TR, Stone MH, Wroblewski BM, Fisher J, Ingham E. Comparison of the response of primary murine peritoneal macrophages and the U937 human histiocytic cell line to challenge with in vitro generated clinically relevant UHMWPE particles. Bio-Med Mater Eng. 2000;10(3-4):229-40.
    • (2000) Bio-Med Mater Eng , vol.10 , Issue.3-4 , pp. 229-240
    • Matthews, J.B.1    Green, T.R.2    Stone, M.H.3    Wroblewski, B.M.4    Fisher, J.5    Ingham, E.6
  • 19
    • 77956967960 scopus 로고    scopus 로고
    • Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo
    • doi:10.1016/j.actbio.2010.06.002
    • Utzschneider S, Becker F, Grupp TM, Sievers B, Paulus A, Gottschalk O, et al. Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. Acta Biomater. 2010;6(11):4296-304. doi:10.1016/j.actbio.2010.06.002.
    • (2010) Acta Biomater , vol.6 , Issue.11 , pp. 4296-4304
    • Utzschneider, S.1    Becker, F.2    Grupp, T.M.3    Sievers, B.4    Paulus, A.5    Gottschalk, O.6
  • 22
    • 0024691001 scopus 로고
    • Computer assisted leukocyte adhesion measurement in intravital microscopy
    • Zeintl H, Sack FU, Intaglietta M, Messmer K. Computer assisted leukocyte adhesion measurement in intravital microscopy. Int J Microcirc Clin Exp. 1989;8(3):293-302.
    • (1989) Int J Microcirc Clin Exp , vol.8 , Issue.3 , pp. 293-302
    • Zeintl, H.1    Sack, F.U.2    Intaglietta, M.3    Messmer, K.4
  • 24
    • 0017484255 scopus 로고
    • Antigen-induced arthritis in mice. I. Induction of arthritis in various strains of mice
    • Brackertz D, Mitchell GF, Mackay IR. Antigen-induced arthritis in mice. I. Induction of arthritis in various strains of mice. Arthritis Rheum. 1977;20(3):841-850.
    • (1977) Arthritis Rheum , vol.20 , Issue.3 , pp. 841-850
    • Brackertz, D.1    Mitchell, G.F.2    Mackay, I.R.3
  • 25
    • 84893428282 scopus 로고    scopus 로고
    • Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo
    • doi:10.1007/s10856-013-5037-8
    • Lorber V, Paulus AC, Buschmann A, Schmitt B, Grupp TM, Jansson V, et al. Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo. J Mater Sci Mater Med. 2014;25(1):141-9. doi:10.1007/s10856-013-5037- 8.
    • (2014) J Mater Sci Mater Med , vol.25 , Issue.1 , pp. 141-149
    • Lorber, V.1    Paulus, A.C.2    Buschmann, A.3    Schmitt, B.4    Grupp, T.M.5    Jansson, V.6
  • 26
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am Vol. 1992;74(6):849-63.
    • (1992) J Bone Joint Surg Am Vol , vol.74 , Issue.6 , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 27
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban RM, Jacobs JJ, Tomlinson MJ, Gavrilovic J, Black J, Peoc'h M. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg Am Vol. 2000;82(4):457-76.
    • (2000) J Bone Joint Surg Am Vol , vol.82 , Issue.4 , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Gavrilovic, J.4    Black, J.5    Peoc'H, M.6
  • 28
    • 77954135424 scopus 로고    scopus 로고
    • The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
    • doi:10.1002/jbm.b.31638
    • Gallo J, Slouf M, Goodman SB. The relationship of polyethylene wear to particle size, distribution, and number: a possible factor explaining the risk of osteolysis after hip arthroplasty. J Biomed Mater Res B Appl Biomater. 2010;94(1):171-7. doi:10.1002/jbm.b.31638.
    • (2010) J Biomed Mater Res B Appl Biomater , vol.94 , Issue.1 , pp. 171-177
    • Gallo, J.1    Slouf, M.2    Goodman, S.B.3
  • 30
    • 52749083004 scopus 로고    scopus 로고
    • The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses
    • doi:10.1098/rsif 2008.0142
    • Revell PA. The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses. J R Soc Interface. 2008;5(28):1263-78. doi:10.1098/rsif 2008.0142.
    • (2008) J R Soc Interface , vol.5 , Issue.28 , pp. 1263-1278
    • Revell, P.A.1
  • 31
    • 0032531288 scopus 로고    scopus 로고
    • Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: Effects of size, concentration, and composition
    • DOI 10.1002/(SICI)1097-4636(19980915)41:4<600::AID
    • Catelas I, Huk OL, Petit A, Zukor DJ, Marchand R, Yahia L. Flow cytometric analysis of macrophage response to ceramic and polyethylene particles: effects of size, concentration, and composition. J Biomed Mater Res. 1998;41(4):600-7. (Pubitemid 28355445)
    • (1998) Journal of Biomedical Materials Research , vol.41 , Issue.4 , pp. 600-607
    • Catelas, I.1    Huk, O.L.2    Petit, A.3    Zukor, D.J.4    Marchand, R.5    Yahia, L.6
  • 34
    • 0033814272 scopus 로고    scopus 로고
    • Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles
    • Green TR, Fisher J, Matthews JB, Stone MH, Ingham E. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res. 2000;53(5):490-7.
    • (2000) J Biomed Mater Res , vol.53 , Issue.5 , pp. 490-497
    • Green, T.R.1    Fisher, J.2    Matthews, J.B.3    Stone, M.H.4    Ingham, E.5
  • 35
    • 48949116171 scopus 로고    scopus 로고
    • Highly crosslinked vs conventional polyethylene particles-an in vitro comparison of biologic activities
    • doi:10.1016/j.arth.2007.05.043
    • Illgen RL 2nd, Forsythe TM, Pike JW, Laurent MP, Blanchard CR. Highly crosslinked vs conventional polyethylene particles-an in vitro comparison of biologic activities. J Arthroplast. 2008;23(5):721-31. doi:10.1016/j.arth.2007. 05.043.
    • (2008) J Arthroplast , vol.23 , Issue.5 , pp. 721-731
    • Illgen II, R.L.1    Forsythe, T.M.2    Pike, J.W.3    Laurent, M.P.4    Blanchard, C.R.5
  • 37
    • 25844439312 scopus 로고    scopus 로고
    • The osteolytic response of macrophages to challenge with particles of Simplex P, Endurance, Palacos R, and Vertebroplastic bone cement particles in vitro
    • DOI 10.1002/jbm.b.30308
    • Ingram JH, Kowalski R, Fisher J, Ingham E. The osteolytic response of macrophages to challenge with particles of Simplex P, Endurance, Palacos R, and Vertebroplastic bone cement particles in vitro. J Biomed Mater Res B Appl Biomater. 2005;75(1):210-20. doi:10.1002/jbm.b.30308. (Pubitemid 41395763)
    • (2005) Journal of Biomedical Materials Research - Part B Applied Biomaterials , vol.75 , Issue.1 , pp. 210-220
    • Ingram, J.H.1    Kowalski, R.2    Fisher, J.3    Ingham, E.4
  • 38
    • 0034955101 scopus 로고    scopus 로고
    • Radiological signs of osteitis around extramedullary metal implants. A radiographic-microbiological correlative analysis in rabbit tibiae after local inoculation of Staphylococcus aureus
    • DOI 10.1007/s004020000235
    • Kraft CN, Schlegel U, Pfluger D, Eijer H, Textor J, Hansis M, et al. Radiological signs of osteitis around extramedullary metal implants. A radiographic-microbiological correlative analysis in rabbit tibiae after local inoculation of Staphylococcus aureus. Arch Orthop Trauma Surg. 2001;121(6):338-42. (Pubitemid 32591037)
    • (2001) Archives of Orthopaedic and Trauma Surgery , vol.121 , Issue.6 , pp. 338-342
    • Kraft, C.N.1    Schlegel, U.2    Pfluger, D.3    Eijer, H.4    Textor, J.5    Hansis, M.6    Arens, S.7
  • 39
    • 0037276254 scopus 로고    scopus 로고
    • Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel
    • Kraft CN, Diedrich O, Burian B, Schmitt O, Wimmer MA. Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel. J Bone Joint Surg Br. 2003;85(1):133-41.
    • (2003) J Bone Joint Surg Br , vol.85 , Issue.1 , pp. 133-141
    • Kraft, C.N.1    Diedrich, O.2    Burian, B.3    Schmitt, O.4    Wimmer, M.A.5
  • 40
    • 0023677786 scopus 로고
    • The synovial response to intra-articular cobalt-chrome wear particles
    • Howie DW, Vernon-Roberts B. The synovial response to intra-articular cobalt-chrome wear particles. Clin Orthop Relat Res. 1988;232:244-54.
    • (1988) Clin Orthop Relat Res , vol.232 , pp. 244-254
    • Howie, D.W.1    Vernon-Roberts, B.2
  • 42
    • 79955938719 scopus 로고    scopus 로고
    • Vitamin E diffused, highly crosslinked UHMWPE: A review
    • doi:10.1007/s00264-010-1161-y
    • Oral E, Muratoglu OK. Vitamin E diffused, highly crosslinked UHMWPE: a review. Int Orthop. 2011;35(2):215-23. doi:10.1007/s00264-010-1161-y.
    • (2011) Int Orthop , vol.35 , Issue.2 , pp. 215-223
    • Oral, E.1    Muratoglu, O.K.2
  • 43
    • 57649103506 scopus 로고    scopus 로고
    • Highly crosslinked vs conventional polyethylene particles: Relative in vivo inflammatory response
    • doi:10.1016/j.arth.2008.01.134
    • Illgen RL 2nd, Bauer LM, Hotujec BT, Kolpin SE, Bakhtiar A, Forsythe TM. Highly crosslinked vs conventional polyethylene particles: relative in vivo inflammatory response. J Arthroplast. 2009;24(1):117-24. doi:10.1016/j.arth. 2008.01.134.
    • (2009) J Arthroplast , vol.24 , Issue.1 , pp. 117-124
    • Illgen II, R.L.1    Bauer, L.M.2    Hotujec, B.T.3    Kolpin, S.E.4    Bakhtiar, A.5    Forsythe, T.M.6
  • 44
    • 79960964085 scopus 로고    scopus 로고
    • UHMWPE for arthroplasty: From powder to debris. Editorial comment: A perspective on polyethylene
    • doi:10.1007/s11999-011-1853-7
    • Kurtz SM, Costa L. UHMWPE for arthroplasty: from powder to debris. Editorial comment: a perspective on polyethylene. Clin Orthop Relat Res. 2011;469(8):2260-1. doi:10.1007/s11999-011-1853-7.
    • (2011) Clin Orthop Relat Res , vol.469 , Issue.8 , pp. 2260-2261
    • Kurtz, S.M.1    Costa, L.2
  • 45
    • 84876359713 scopus 로고    scopus 로고
    • Alternative bearings in total knee arthroplasty: Risk of early revision compared to traditional bearings: An analysis of 62,177 primary cases
    • doi:10.3109/17453674.2013.784660
    • Inacio MC, Cafri G, Paxton EW, Kurtz SM, Namba RS. Alternative bearings in total knee arthroplasty: risk of early revision compared to traditional bearings: an analysis of 62,177 primary cases. Acta Orthop. 2013;84(2):145-52. doi:10.3109/17453674.2013.784660.
    • (2013) Acta Orthop , vol.84 , Issue.2 , pp. 145-152
    • Inacio, M.C.1    Cafri, G.2    Paxton, E.W.3    Kurtz, S.M.4    Namba, R.S.5
  • 46
    • 54449100155 scopus 로고    scopus 로고
    • Highly crosslinked polyethylene is safe for use in total knee arthroplasty
    • doi:10.1007/s11999-008-0472-4
    • Hodrick JT, Severson EP, McAlister DS, Dahl B, Hofmann AA. Highly crosslinked polyethylene is safe for use in total knee arthroplasty. Clin Orthop Relat Res. 2008;466(11):2806-12. doi:10.1007/s11999-008-0472-4.
    • (2008) Clin Orthop Relat Res , vol.466 , Issue.11 , pp. 2806-2812
    • Hodrick, J.T.1    Severson, E.P.2    McAlister, D.S.3    Dahl, B.4    Hofmann, A.A.5
  • 47
    • 69049115077 scopus 로고    scopus 로고
    • Comparison between highly cross-linked and conventional polyethylene in total knee arthroplasty
    • doi:10.1016/j.knee.2009.01.005
    • Minoda Y, Aihara M, Sakawa A, Fukuoka S, Hayakawa K, Tomita M, et al. Comparison between highly cross-linked and conventional polyethylene in total knee arthroplasty. Knee. 2009;16(5):348-51. doi:10.1016/j.knee.2009.01.005.
    • (2009) Knee , vol.16 , Issue.5 , pp. 348-351
    • Minoda, Y.1    Aihara, M.2    Sakawa, A.3    Fukuoka, S.4    Hayakawa, K.5    Tomita, M.6
  • 49
    • 57449098221 scopus 로고    scopus 로고
    • Classification of prosthetic loosening and determination of wear particles
    • doi:10.1007/s00292-008-1070-7
    • Otto M. Classification of prosthetic loosening and determination of wear particles. Der Pathol. 2008;29(Suppl 2):232-9. doi:10.1007/s00292-008-1070-7.
    • (2008) Der Pathol , vol.29 , Issue.SUPPL. 2 , pp. 232-239
    • Otto, M.1
  • 50
    • 2442495049 scopus 로고    scopus 로고
    • Migration of Polyethylene Particles Around Nonloosened Cemented Femoral Components from a Total Hip Arthroplasty - An Autopsy Study
    • Massin P, Chappard D, Flautre B, Hardouin P. Migration of polyethylene particles around nonloosened cemented femoral components from a total hip arthroplasty-an autopsy study. J Biomed Mater Res B Appl Biomater. 2004;69(2):205-15. doi:10.1002/jbm.b.30001. (Pubitemid 38619778)
    • (2004) Journal of Biomedical Materials Research - Part B Applied Biomaterials , vol.69 , Issue.2 , pp. 205-215
    • Massin, P.1    Chappard, D.2    Flautre, B.3    Hardouin, P.4
  • 52
    • 84888870613 scopus 로고    scopus 로고
    • Polyethylene wear particles play a role in development of osteoarthritis via detrimental effects on cartilage, meniscus, and synovium
    • doi:10.1016/j.joca.2013.09.013
    • Park DY, Min BH, Kim DW, Song BR, Kim M, Kim YJ. Polyethylene wear particles play a role in development of osteoarthritis via detrimental effects on cartilage, meniscus, and synovium. OARS. 2013;21(12):2021-9. doi:10.1016/j.joca.2013.09.013.
    • (2013) OARS , vol.21 , Issue.12 , pp. 2021-2029
    • Park, D.Y.1    Min, B.H.2    Kim, D.W.3    Song, B.R.4    Kim, M.5    Kim, Y.J.6
  • 53
    • 79960560545 scopus 로고    scopus 로고
    • Polyethylene and metal wear particles: Characteristics and biological effects
    • doi:10.1007/s00281-011-0242-3
    • Catelas I, Wimmer MA, Utzschneider S. Polyethylene and metal wear particles: characteristics and biological effects. Semin Immunopathol. 2011;33(3):257-71. doi:10.1007/s00281-011-0242-3.
    • (2011) Semin Immunopathol , vol.33 , Issue.3 , pp. 257-271
    • Catelas, I.1    Wimmer, M.A.2    Utzschneider, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.