-
1
-
-
0032775639
-
Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
-
Kurtz S.M., Muratoglu O.K., Evans M., Edidin A.A. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 20(18):1999;1659-1688
-
(1999)
Biomaterials
, vol.20
, Issue.18
, pp. 1659-1688
-
-
Kurtz, S.M.1
Muratoglu, O.K.2
Evans, M.3
Edidin, A.A.4
-
2
-
-
0004185615
-
The problem is osteolysis
-
Harris W. The problem is osteolysis. J Biomed Mater Res. 31:1996;19-26
-
(1996)
J Biomed Mater Res
, vol.31
, pp. 19-26
-
-
Harris, W.1
-
3
-
-
0029955320
-
Impact of γ-sterilization on clinical performance of polyethylene in the knee
-
Collier J.P., Sperling D.K., Currier J.H., Sutula L.C., Saum K.A., Mayor M.B. Impact of γ-sterilization on clinical performance of polyethylene in the knee. J Arthroplasty. 11(4):1996;377-389
-
(1996)
J Arthroplasty
, vol.11
, Issue.4
, pp. 377-389
-
-
Collier, J.P.1
Sperling, D.K.2
Currier, J.H.3
Sutula, L.C.4
Saum, K.A.5
Mayor, M.B.6
-
4
-
-
0026346472
-
Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
-
Collier J.P., Mayor M.B., McNamara J.L., Surprenant V.A., Jensen R.E. Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop Relat Res. 273:1991;232-242
-
(1991)
Clin Orthop Relat Res
, vol.273
, pp. 232-242
-
-
Collier, J.P.1
Mayor, M.B.2
McNamara, J.L.3
Surprenant, V.A.4
Jensen, R.E.5
-
5
-
-
0035100880
-
Loosening and osteolysis with the press-fit condylar posterior-cruciate- substituting total knee replacement
-
Mikulak S.A., Mahoney O.M., dela Rosa M.A., Schmalzried T.P. Loosening and osteolysis with the press-fit condylar posterior-cruciate-substituting total knee replacement. J Bone Joint Surg Am Vol. 83-A(3):2001;398-403
-
(2001)
J Bone Joint Surg Am Vol
, vol.83
, Issue.3
, pp. 398-403
-
-
Mikulak, S.A.1
Mahoney, O.M.2
Dela Rosa, M.A.3
Schmalzried, T.P.4
-
6
-
-
0036704094
-
Osteolysis associated with a cemented modular posterior-cruciate- substituting total knee design: Five to eight-year follow-up
-
O'Rourke M.R., Callaghan J.J., Goetz D.D., Sullivan P.M., Johnston R.C. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design. five to eight-year follow-up J Bone Joint Surg. 84-A(8):2002;1362-1371
-
(2002)
J Bone Joint Surg
, vol.84
, Issue.8
, pp. 1362-1371
-
-
O'Rourke, M.R.1
Callaghan, J.J.2
Goetz, D.D.3
Sullivan, P.M.4
Johnston, R.C.5
-
7
-
-
0035117295
-
A novel method of crosslinking UHMWPE to improve wear, reduce oxidation and retain mechanical properties
-
Muratoglu O.K., Bragdon C.R., O'Connor D.O., Jasty M., Harris W.H. A novel method of crosslinking UHMWPE to improve wear, reduce oxidation and retain mechanical properties. J Arthroplasty. 16(2):2001;149-160
-
(2001)
J Arthroplasty
, vol.16
, Issue.2
, pp. 149-160
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.O.3
Jasty, M.4
Harris, W.H.5
-
8
-
-
0033178826
-
Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
-
Muratoglu O.K., Bragdon C.R., O'Connor D.O., Jasty M., Harris W.H., Gul R., et al. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials. 20(16):1999;1463-1470
-
(1999)
Biomaterials
, vol.20
, Issue.16
, pp. 1463-1470
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.O.3
Jasty, M.4
Harris, W.H.5
Gul, R.6
-
9
-
-
0032927112
-
Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements
-
McKellop H., Shen F-.W., Lu B., Campbell P., Salovey R. Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements. J Orthop Res. 17(2):1999;157-167
-
(1999)
J Orthop Res
, vol.17
, Issue.2
, pp. 157-167
-
-
McKellop, H.1
Shen -., F.W.2
Lu, B.3
Campbell, P.4
Salovey, R.5
-
10
-
-
2342511045
-
-
Andersen S, Brondted P, Lillhot H, Lystrup A, Rheinlander J, Sorensen B, et al., editors. Denmark, Roskilde: Riso National Laboratory;
-
Argon AS, Bartczak Z, Cohen RE, Muratoglu OK. In: Andersen S, Brondted P, Lillhot H, Lystrup A, Rheinlander J, Sorensen B, et al., editors. Novel mechanisms of toughening semi-crystalline polymers. Denmark, Roskilde: Riso National Laboratory; 1997.
-
(1997)
Novel Mechanisms of Toughening Semi-crystalline Polymers
-
-
Argon, A.S.1
Bartczak, Z.2
Cohen, R.E.3
Muratoglu, O.K.4
-
11
-
-
0033990310
-
Compression and tension fatigue resistance of medical grade ultra high molecular weight polyethylene: The effect of morphology, sterilization, aging and temperature
-
Baker D.A., Hastings R.S., Pruitt L. Compression and tension fatigue resistance of medical grade ultra high molecular weight polyethylene. the effect of morphology, sterilization, aging and temperature Polymer. 41(2):2000;795-808
-
(2000)
Polymer
, vol.41
, Issue.2
, pp. 795-808
-
-
Baker, D.A.1
Hastings, R.S.2
Pruitt, L.3
-
12
-
-
0030015296
-
The chemistry and antioxidant properties of tocopherols and tocotrienols
-
Kamal-Eldin A., Appelqvist L. The chemistry and antioxidant properties of tocopherols and tocotrienols. Lipids. 31(7):1996;671-701
-
(1996)
Lipids
, vol.31
, Issue.7
, pp. 671-701
-
-
Kamal-Eldin, A.1
Appelqvist, L.2
-
13
-
-
0020074850
-
Autoxidation of biological molecules, 1, the antioxidant activity of vitamin e and related chain-breaking phenolic antioxidants in vitro
-
Burton G., Ingold K. Autoxidation of biological molecules, 1, the antioxidant activity of vitamin E and related chain-breaking phenolic antioxidants in vitro. J Am Achem Soc. 103:1981;6472-6477
-
(1981)
J Am Achem Soc
, vol.103
, pp. 6472-6477
-
-
Burton, G.1
Ingold, K.2
-
14
-
-
2342459785
-
Reactions of vitamin e with alkylperoxy radicals in homgeneous solution and liposomes
-
M. Rodgers, & E. Powers. New York: Academic Press
-
Winterle J., Mill T. Reactions of vitamin E with alkylperoxy radicals in homgeneous solution and liposomes. Rodgers M., Powers E. Oxygen and oxy-radicals in chemistry and Biology. 1981;779-780 Academic Press, New York
-
(1981)
Oxygen and Oxy-radicals in Chemistry and Biology
, pp. 779-780
-
-
Winterle, J.1
Mill, T.2
-
17
-
-
0000082414
-
Development of an accelerated aging method for evaluation of long-term irradiation effects on UHMWPE Implants
-
Washington, DC: Division of Polymer Chemistry;
-
Sun D, Stark C, Dumbleton J. Development of an accelerated aging method for evaluation of long-term irradiation effects on UHMWPE Implants. In: Meeting of American Chemical Society. Washington, DC: Division of Polymer Chemistry; 1994. p. 969-70.
-
(1994)
Meeting of American Chemical Society
, pp. 969-970
-
-
Sun, D.1
Stark, C.2
Dumbleton, J.3
-
18
-
-
1642320948
-
Effect of lipid absorption on wear and compressive properties of unirradiated and highly crosslinked UHMWPE: An in vitro experimental model
-
in press.
-
Greenbaum E, Burroughs B, Harris W, Muratoglu O. Effect of lipid absorption on wear and compressive properties of unirradiated and highly crosslinked UHMWPE: an in vitro experimental model. Biomaterials, in press.
-
Biomaterials
-
-
Greenbaum, E.1
Burroughs, B.2
Harris, W.3
Muratoglu, O.4
-
19
-
-
0036156446
-
Interlaboratory validation of oxidation-index measurement methods for UHMWPE after long-term shelf aging
-
Kurtz S.M., Muratoglu O.K., Gsell R., Greer K., Shen F-.W., Cooper C., et al. Interlaboratory validation of oxidation-index measurement methods for UHMWPE after long-term shelf aging. J Biomed Mater Res (Appl Biomater). 63(1):2002;15-23
-
(2002)
J Biomed Mater Res (Appl Biomater)
, vol.63
, Issue.1
, pp. 15-23
-
-
Kurtz, S.M.1
Muratoglu, O.K.2
Gsell, R.3
Greer, K.4
Shen -., F.W.5
Cooper, C.6
-
20
-
-
0344308259
-
Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene
-
Muratoglu O.K., Merrill E.W., Bragdon C.R., O'Connor D.O., Hoeffel D., Burroughs B., et al. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res. 417:2003;253-262
-
(2003)
Clin Orthop Relat Res
, vol.417
, pp. 253-262
-
-
Muratoglu, O.K.1
Merrill, E.W.2
Bragdon, C.R.3
O'Connor, D.O.4
Hoeffel, D.5
Burroughs, B.6
-
21
-
-
0034891561
-
A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty
-
Bragdon C.R., O'Connor D.O., Lowenstein J.D., Jasty M., Biggs S.A., Harris W.H. A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty. J Arthroplasty. 16(5):2001;658-665
-
(2001)
J Arthroplasty
, vol.16
, Issue.5
, pp. 658-665
-
-
Bragdon, C.R.1
O'Connor, D.O.2
Lowenstein, J.D.3
Jasty, M.4
Biggs, S.A.5
Harris, W.H.6
|