메뉴 건너뛰기




Volumn 43, Issue 5, 2014, Pages

A pragmatic approach to determine the optimal kVp in cone beam CT: Balancing contrast-to-noise ratio and radiation dose

Author keywords

Cone beam computed tomography; Image contrast; Optimization; Radiation dose

Indexed keywords

ALUMINUM; POLITEF; POLY(METHYL METHACRYLATE); POLYETHYLENE;

EID: 84903642850     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr.20140059     Document Type: Article
Times cited : (108)

References (24)
  • 1
    • 84864022337 scopus 로고    scopus 로고
    • Max-illofacial cone beam computed tomography: Essence, elements and steps to interpretation
    • doi:10.1111/j.1834-7819.2011.01657.x
    • Scarfe WC, Li Z, Aboelmaaty W., Scott SA, Farman AG Max-illofacial cone beam computed tomography: essence, elements and steps to interpretation. Aust Dent J 2012; 57(Suppl. 1): 46-60. doi:10.1111/j.1834-7819.2011.01657.x
    • (2012) Aust Dent J , vol.57 , Issue.SUPPL. 1 , pp. 46-60
    • Scarfe, W.C.1    Li, Z.2    Aboelmaaty, W.3    Scott, S.A.4    Farman, A.G.5
  • 2
    • 84885605462 scopus 로고    scopus 로고
    • Cone beam CT: A current overview of devices
    • doi:10.1259/dmfr.20120443
    • Nemtoi A, Czink C, Haba D., Gahleitner A. Cone beam CT: a current overview of devices. Dentomaxillofac Radiol 2013; 42: 20120443. doi:10.1259/dmfr.20120443
    • (2013) Dentomaxillofac Radiol , vol.42 , pp. 20120443
    • Nemtoi, A.1    Czink, C.2    Haba, D.3    Gahleitner, A.4
  • 3
    • 78649496644 scopus 로고    scopus 로고
    • Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols
    • doi:10.1016/j.tripleo.2010.06.013
    • Qu XM, Li G, Ludlow J.B., Zhang ZY, Ma XC Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 770-6. doi:10.1016/j.tripleo.2010.06.013
    • (2010) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.110 , pp. 770-776
    • Qu, X.M.1    Li, G.2    Ludlow, J.B.3    Zhang, Z.Y.4    Ma, X.C.5
  • 4
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
    • doi:10.1016/j.tripleo.2008.03.018
    • Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 106-14. doi:10.1016/j.tripleo.2008.03.018
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 106-114
    • Ludlow, J.B.1    Ivanovic, M.2
  • 5
    • 84855604583 scopus 로고    scopus 로고
    • Effective dose range for dental cone beam computed tomography scanners
    • doi:10.1016/j.ejrad.2010.11.028
    • Pauwels R, Beinsberger J, Collaert B., Theodorakou C, Rogers J, Walker A., et al. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 2012; 81: 267-71. doi:10.1016/j.ejrad.2010.11.028
    • (2012) Eur J Radiol , vol.81 , pp. 267-271
    • Pauwels, R.1    Beinsberger, J.2    Collaert, B.3    Theodorakou, C.4    Rogers, J.5    Walker, A.6
  • 6
    • 85027955064 scopus 로고    scopus 로고
    • Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses
    • doi:10.1007/s00405-012-2177-2
    • Güldner C., Ningo A, Voigt J., Diogo I, Heinrichs J, Weber R., et al. Potential of dosage reduction in cone-beam-computed tomography (CBCT) for radiological diagnostics of the paranasal sinuses. Eur Arch Otorhinolaryngol 2013; 270: 1307-15. doi:10.1007/s00405-012-2177-2
    • (2013) Eur Arch Otorhinolaryngol , vol.270 , pp. 1307-1315
    • Güldner, C.1    Ningo, A.2    Voigt, J.3    Diogo, I.4    Heinrichs, J.5    Weber, R.6
  • 7
    • 38749120980 scopus 로고    scopus 로고
    • Image quality produced by different cone-beam computed tomography settings
    • doi:10.1016/j.ajodo.2007.02.053
    • Kwong JC, Palomo JM, Landers M.A., Figueroa A., Hans MG Image quality produced by different cone-beam computed tomography settings. Am J Orthod Dentofacial Orthop 2008; 133: 317-27. doi:10.1016/j.ajodo.2007.02.053
    • (2008) Am J Orthod Dentofacial Orthop , vol.133 , pp. 317-327
    • Kwong, J.C.1    Palomo, J.M.2    Landers, M.A.3    Figueroa, A.4    Hans, M.G.5
  • 8
    • 80053624517 scopus 로고    scopus 로고
    • Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view
    • doi:10.1016/j.ejrad. 2010.09.018
    • Lofthag-Hansen S., Thilander-Klang A, Gröndahl K. Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view. Eur J Radiol 2011; 80: 483-8. doi:10.1016/j.ejrad. 2010.09.018
    • (2011) Eur J Radiol , vol.80 , pp. 483-488
    • Lofthag-Hansen, S.1    Thilander-Klang, A.2    Gröndahl, K.3
  • 9
    • 84866619387 scopus 로고    scopus 로고
    • Effect of electric potential and current on mandibular linear measurements in cone beam CT
    • doi:10.1259/dmfr/51664704
    • Panmekiate S, Apinhasmit W, Petersson A. Effect of electric potential and current on mandibular linear measurements in cone beam CT. Dentomaxillofac Radiol 2012; 41: 578-82. doi:10.1259/dmfr/51664704
    • (2012) Dentomaxillofac Radiol , vol.41 , pp. 578-582
    • Panmekiate, S.1    Apinhasmit, W.2    Petersson, A.3
  • 10
    • 84855264144 scopus 로고    scopus 로고
    • Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site
    • doi:10.1259/dmfr/16421849
    • Dawood A, Brown J, Sauret-Jackson V, Purkayastha S. Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site. Dentomaxillofac Radiol 2012; 41: 70-4. doi:10.1259/dmfr/16421849
    • (2012) Dentomaxillofac Radiol , vol.41 , pp. 70-74
    • Dawood, A.1    Brown, J.2    Sauret-Jackson, V.3    Purkayastha, S.4
  • 11
    • 78049393888 scopus 로고    scopus 로고
    • Effects of tube current on cone-beam computerized tomography image quality for presurgical implant planning in vitro
    • doi:10.1016/j.tripleo.2010.03.041
    • Sur J, Seki K, Koizumi H., Nakajima K, Okano T. Effects of tube current on cone-beam computerized tomography image quality for presurgical implant planning in vitro. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: e29-33. doi:10.1016/j.tripleo.2010.03.041
    • (2010) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.110
    • Sur, J.1    Seki, K.2    Koizumi, H.3    Nakajima, K.4    Okano, T.5
  • 13
    • 84866600061 scopus 로고    scopus 로고
    • Dose distribution for dental cone beam CT and its implication for defining a dose index
    • doi:10.1259/dmfr/20920453
    • Pauwels R, Theodorakou C, Walker A., Bosmans H, Jacobs R, Horner K., et al. Dose distribution for dental cone beam CT and its implication for defining a dose index. Dento-maxillofac Radiol 2012; 41: 583-93. doi:10.1259/dmfr/20920453
    • (2012) Dento-maxillofac Radiol , vol.41 , pp. 583-593
    • Pauwels, R.1    Theodorakou, C.2    Walker, A.3    Bosmans, H.4    Jacobs, R.5    Horner, K.6
  • 14
    • 81855228753 scopus 로고    scopus 로고
    • Development and applicability of a quality control phantom for dental cone-beam CT
    • doi:10.1120/jacmp. v12i4.3478
    • Pauwels R, Stamatakis H, Manousaridis G., Walker A, Michielsen K, Bosmans H., et al. Development and applicability of a quality control phantom for dental cone-beam CT. J Appl Clin Med Phys 2011; 12: 245-60. doi:10.1120/jacmp. v12i4.3478
    • (2011) J Appl Clin Med Phys , vol.12 , pp. 245-260
    • Pauwels, R.1    Stamatakis, H.2    Manousaridis, G.3    Walker, A.4    Michielsen, K.5    Bosmans, H.6
  • 15
    • 84871891269 scopus 로고    scopus 로고
    • Variability of dental cone beam CT grey values for density estimations
    • doi:10.1259/bjr.20120135
    • Pauwels R, Nackaerts O, Bellaiche N., Stamatakis H, Tsiklakis K, Walker A., et al. Variability of dental cone beam CT grey values for density estimations. Br J Radiol 2013; 86: 20120135. doi:10.1259/bjr.20120135
    • (2013) Br J Radiol , vol.86 , pp. 20120135
    • Pauwels, R.1    Nackaerts, O.2    Bellaiche, N.3    Stamatakis, H.4    Tsiklakis, K.5    Walker, A.6
  • 16
    • 84880237066 scopus 로고    scopus 로고
    • Monte Carlo modeling for dose assessment in cone beam CT for oral and maxillofacial applications
    • doi:10.1118/1.4810967
    • Zhang G, Marshall N, Bogaerts R., Jacobs R, Bosmans H. Monte Carlo modeling for dose assessment in cone beam CT for oral and maxillofacial applications. Med Phys 2013; 40: 072103. doi:10.1118/1.4810967
    • (2013) Med Phys , vol.40 , pp. 072103
    • Zhang, G.1    Marshall, N.2    Bogaerts, R.3    Jacobs, R.4    Bosmans, H.5
  • 17
    • 84885670529 scopus 로고    scopus 로고
    • Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom
    • doi:10.1259/dmfr.20120445
    • Bamba J, Araki K, Endo A., Okano T. Image quality assessment of three cone beam CT machines using the SEDENTEXCT CT phantom. Dentomaxillofac Radiol 2013; 42: 20120445. doi:10.1259/dmfr.20120445
    • (2013) Dentomaxillofac Radiol , vol.42 , pp. 20120445
    • Bamba, J.1    Araki, K.2    Endo, A.3    Okano, T.4
  • 18
    • 84888628062 scopus 로고    scopus 로고
    • Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography
    • doi:10.1016/j.ajodo.2013.07.013
    • Ludlow JB, Walker C. Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2013; 144: 802-17. doi:10.1016/j.ajodo.2013.07.013
    • (2013) Am J Orthod Dentofacial Orthop , vol.144 , pp. 802-817
    • Ludlow, J.B.1    Walker, C.2
  • 19
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    • doi:10.1259/dmfr/15779208
    • Suomalainen A, Kiljunen T, Käser Y, Peltola J., Kortesniemi M. Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners. Dentomaxillofac Radiol 2009; 38: 367-78. doi:10.1259/dmfr/15779208
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 367-378
    • Suomalainen, A.1    Kiljunen, T.2    Käser, Y.3    Peltola, J.4    Kortesniemi, M.5
  • 20
    • 66949172475 scopus 로고    scopus 로고
    • Cone-beam computed tomography: A new method for imaging of the temporal bone
    • doi:10.1080/02841850902839700
    • Peltonen LI, Aarnisalo AA, Käser Y, Kortesniemi M.K., Robinson S., Suomalainen A, et al Cone-beam computed tomography: a new method for imaging of the temporal bone. Acta Radiol 2009; 50: 543-8. doi:10.1080/02841850902839700
    • (2009) Acta Radiol , vol.50 , pp. 543-548
    • Peltonen, L.I.1    Aarnisalo, A.A.2    Käser, Y.3    Kortesniemi, M.K.4    Robinson, S.5    Suomalainen, A.6
  • 21
    • 7044228012 scopus 로고    scopus 로고
    • Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    • doi:10.1148/radiol.2332032107
    • Siegel MJ, Schmidt B, Bradley D., Suess C, Hildebolt C. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology 2004; 233: 515-22. doi:10.1148/radiol.2332032107
    • (2004) Radiology , vol.233 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5
  • 22
    • 84880331333 scopus 로고    scopus 로고
    • Optimised low-dose multidetector CT protocol for children with cranial deformity
    • doi:10.1007/s00330-013-2806-1
    • Vazquez JL, Pombar MA, Pumar J.M., del Campo VM. Optimised low-dose multidetector CT protocol for children with cranial deformity. Eur Radiol 2013; 23: 2279-87. doi:10.1007/s00330-013-2806-1
    • (2013) Eur Radiol , vol.23 , pp. 2279-2287
    • Vazquez, J.L.1    Pombar, M.A.2    Pumar, J.M.3    Del Campo, V.M.4
  • 23
    • 52949134425 scopus 로고    scopus 로고
    • Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality
    • doi:10.1118/1.2977535
    • Papadakis AE, Perisinakis K, Damilakis J. Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality. Med Phys 2008; 35: 4567-76. doi:10.1118/1.2977535
    • (2008) Med Phys , vol.35 , pp. 4567-4576
    • Papadakis, A.E.1    Perisinakis, K.2    Damilakis, J.3
  • 24
    • 84869444977 scopus 로고    scopus 로고
    • Future prospects for dental cone beam CT imaging
    • doi:10.2217/IIM.12.45
    • Pauwels R, Jacobs R, Bosmans H., Schulze R. Future prospects for dental cone beam CT imaging. Imaging Med 2012; 4: 551-63. doi:10.2217/IIM.12.45
    • (2012) Imaging Med , vol.4 , pp. 551-563
    • Pauwels, R.1    Jacobs, R.2    Bosmans, H.3    Schulze, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.