메뉴 건너뛰기




Volumn 133, Issue 2, 2008, Pages 317-327

Image quality produced by different cone-beam computed tomography settings

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CADAVER; CEPHALOMETRY; CONE BEAM COMPUTED TOMOGRAPHY; EVALUATION; FILTRATION; HEAD; HUMAN; IMAGE QUALITY; INSTRUMENTATION; METHODOLOGY; PHOTON; QUESTIONNAIRE; RADIATION DOSE; RADIOGRAPHY; SKULL; STANDARD; TOOTH RADIOGRAPHY;

EID: 38749120980     PISSN: 08895406     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ajodo.2007.02.053     Document Type: Article
Times cited : (73)

References (16)
  • 1
    • 0035650972 scopus 로고    scopus 로고
    • Image accuracy of plain film radiography and computerized tomography in assessing morphological abnormality of impacted teeth
    • Bodner L., Bar-Ziv J., and Becker A. Image accuracy of plain film radiography and computerized tomography in assessing morphological abnormality of impacted teeth. Am J Orthod Dentofacial Orthop 120 (2001) 623-628
    • (2001) Am J Orthod Dentofacial Orthop , vol.120 , pp. 623-628
    • Bodner, L.1    Bar-Ziv, J.2    Becker, A.3
  • 3
    • 5044251144 scopus 로고    scopus 로고
    • Radiation exposure during midfacial imaging using 4 and 16 slice computed tomography, cone beam computed tomography systems and conventional radiography
    • Schulze D., Heiland M., Thurmann H., and Adam G. Radiation exposure during midfacial imaging using 4 and 16 slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofac Radiol 33 (2004) 83-86
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 83-86
    • Schulze, D.1    Heiland, M.2    Thurmann, H.3    Adam, G.4
  • 7
    • 0033776724 scopus 로고    scopus 로고
    • CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction
    • Cohnen M., Fischer H., Hamacher J., Lins E., Kotter R., and Modder U. CT of the head by use of reduced current and kilovoltage: relationship between image quality and dose reduction. AJNR Am J Neuroradiol 21 (2000) 1654-1660
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1654-1660
    • Cohnen, M.1    Fischer, H.2    Hamacher, J.3    Lins, E.4    Kotter, R.5    Modder, U.6
  • 8
    • 24044514660 scopus 로고    scopus 로고
    • Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT
    • Gündogdu S., Mahmutyazicioglu K., Ozdemir H., Savranlar A., and Asil K. Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT. Eur Radiol 15 (2005) 1959-1968
    • (2005) Eur Radiol , vol.15 , pp. 1959-1968
    • Gündogdu, S.1    Mahmutyazicioglu, K.2    Ozdemir, H.3    Savranlar, A.4    Asil, K.5
  • 9
    • 13944281399 scopus 로고    scopus 로고
    • Low-dose dental computed tomography: significant dose reduction without loss of image quality
    • Rustemeyer P., Streubühr U., and Suttmoeller J. Low-dose dental computed tomography: significant dose reduction without loss of image quality. Acta Radiol 45 (2004) 847-853
    • (2004) Acta Radiol , vol.45 , pp. 847-853
    • Rustemeyer, P.1    Streubühr, U.2    Suttmoeller, J.3
  • 12
    • 0035053536 scopus 로고    scopus 로고
    • Effect of scattered radiation on image noise in cone beam CT
    • Endo M., Tsunoo T., Nakamori N., and Yoshida T. Effect of scattered radiation on image noise in cone beam CT. Med Phys 28 (2001) 469-474
    • (2001) Med Phys , vol.28 , pp. 469-474
    • Endo, M.1    Tsunoo, T.2    Nakamori, N.3    Yoshida, T.4
  • 13
    • 7044228012 scopus 로고    scopus 로고
    • Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape
    • Siegel M.J., Schmidt B., Bradley D., Suess C., and Hildebolt C. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology 233 (2004) 515-522
    • (2004) Radiology , vol.233 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5
  • 14
    • 38749127075 scopus 로고
    • The effect of aluminum filter disks in roentgenographic cephalometry
    • Franklin J.B. The effect of aluminum filter disks in roentgenographic cephalometry. Angle Orthod 32 (1962) 252-269
    • (1962) Angle Orthod , vol.32 , pp. 252-269
    • Franklin, J.B.1
  • 15
    • 18244396902 scopus 로고    scopus 로고
    • Effects of aluminum-copper alloy filtration on photon spectra, air kerma rate and image contrast
    • Gonçalves A., Rollo J.M.D., Gonçalves M., Haiter Neto F., and Bóscolo F.N. Effects of aluminum-copper alloy filtration on photon spectra, air kerma rate and image contrast. Braz Dent J 15 (2004) 214-219
    • (2004) Braz Dent J , vol.15 , pp. 214-219
    • Gonçalves, A.1    Rollo, J.M.D.2    Gonçalves, M.3    Haiter Neto, F.4    Bóscolo, F.N.5
  • 16
    • 0032938202 scopus 로고    scopus 로고
    • Measurement of image quality in diagnostic radiography
    • Martin C.J., Sutton D.G., and Sharp P.F. Measurement of image quality in diagnostic radiography. Appl Radiat Isot 50 (1999) 21-38
    • (1999) Appl Radiat Isot , vol.50 , pp. 21-38
    • Martin, C.J.1    Sutton, D.G.2    Sharp, P.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.