메뉴 건너뛰기




Volumn 40, Issue 7, 2013, Pages

Monte Carlo modeling for dose assessment in cone beam CT for oral and maxillofacial applications

Author keywords

anatomical phantoms; cone beam CT; dose calculation; Monte Carlo; oral imaging

Indexed keywords

DOSIMETRY; MONTE CARLO METHODS; PHANTOMS;

EID: 84880237066     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4810967     Document Type: Article
Times cited : (34)

References (34)
  • 1
    • 58849167609 scopus 로고    scopus 로고
    • Doses to patients from radiographic and fluoroscopic x-ray imaging procedures in the UK - 2010 Review
    • (Health Protection Agency, Chilton, UK)
    • D. Hart, M. C. Hillier, and P. C. Shrimpton, " Doses to patients from radiographic and fluoroscopic x-ray imaging procedures in the UK-2010 Review.," HPA-CRCE-034 (Health Protection Agency, Chilton, UK, 2012).
    • (2012) HPA-CRCE-034
    • Hart, D.1    Hillier, M.C.2    Shrimpton, P.C.3
  • 2
    • 67649397320 scopus 로고    scopus 로고
    • Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature
    • 10.1016/j.ijom.2009.02.028
    • W. De Vos, J. Casselman, and G. R. J. Swennen, " Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature.," Int. J. Oral Maxillofac. Surg. 38, 609-625 (2009). 10.1016/j.ijom.2009.02.028
    • (2009) Int. J. Oral Maxillofac. Surg. , vol.38 , pp. 609-625
    • De Vos, W.1    Casselman, J.2    Swennen, G.R.J.3
  • 3
    • 68549104047 scopus 로고    scopus 로고
    • Conebeam CT of the head and neck, part 2: Clinical applications
    • 10.3174/ajnr.A1654
    • A. C. Miracle and S. K. Mukherji, " Conebeam CT of the head and neck, part 2: Clinical applications.," Am. J. Neuroradiol. 30, 1285-1292 (2009). 10.3174/ajnr.A1654
    • (2009) Am. J. Neuroradiol. , vol.30 , pp. 1285-1292
    • Miracle, A.C.1    Mukherji, S.K.2
  • 4
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
    • 10.1016/j.tripleo.2008.03.018
    • J. B. Ludlow and M. Ivanovic, " Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology.," Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. 106, 106-114 (2008). 10.1016/j.tripleo.2008.03.018
    • (2008) Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. , vol.106 , pp. 106-114
    • Ludlow, J.B.1    Ivanovic, M.2
  • 5
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    • 10.1259/dmfr/15779208
    • A. Suomalainen, T. Kiljunen, Y. Kaser, J. Peltola, and M. Kortesniemi, " Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners.," Dentomaxillofac. Radiol. 38, 367-378 (2009). 10.1259/dmfr/15779208
    • (2009) Dentomaxillofac. Radiol. , vol.38 , pp. 367-378
    • Suomalainen, A.1    Kiljunen, T.2    Kaser, Y.3    Peltola, J.4    Kortesniemi, M.5
  • 8
    • 0036923914 scopus 로고    scopus 로고
    • CT-expo - A novel program for dose evaluation in CT
    • 10.1055/s-2002-35937
    • G. Stamm and H. D. Nagel, " CT-expo-A novel program for dose evaluation in CT.," Fortschr Geb Rontgenstrahlen Nuklearmed Erganzungsbd 174, 1570-1576 (2002). 10.1055/s-2002-35937
    • (2002) Fortschr Geb Rontgenstrahlen Nuklearmed Erganzungsbd , vol.174 , pp. 1570-1576
    • Stamm, G.1    Nagel, H.D.2
  • 9
    • 85027231488 scopus 로고    scopus 로고
    • Available URL: (cited on October 16)
    • ImPACT CTDosimetry, Available URL: http://www.impactscan.org (cited on October 16, 2012).
    • (2012) ImPACT CTDosimetry
  • 10
    • 77957358643 scopus 로고    scopus 로고
    • Multisection CT protocols: Sex- and age-specific conversion factors used to determine effective dose from dose-length product
    • 10.1148/radiol.10100047
    • P. D. Deak, Y. Smal, and W. A. Kalender, " Multisection CT protocols: Sex- and age-specific conversion factors used to determine effective dose from dose-length product.," Radiology 257, 158-166 (2010). 10.1148/radiol.10100047
    • (2010) Radiology , vol.257 , pp. 158-166
    • Deak, P.D.1    Smal, Y.2    Kalender, W.A.3
  • 12
    • 67649869942 scopus 로고    scopus 로고
    • The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations
    • 10.1088/0031-9155/54/9/007
    • J. Gu, B. Bednarz, P. F. Caracappa, and X. G. Xu, " The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations.," Phys. Med. Biol. 54, 2699-2717 (2009). 10.1088/0031-9155/54/ 9/007
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2699-2717
    • Gu, J.1    Bednarz, B.2    Caracappa, P.F.3    Xu, X.G.4
  • 13
    • 79952132586 scopus 로고    scopus 로고
    • Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations
    • 10.1118/1.3544658
    • C. Lee, K. P. Kim, D. Long, R. Fisher, C. Tien, S. L. Simon, A. Bouville, and W. E. Bolch, " Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.," Med. Phys. 38, 1196-1206 (2011). 10.1118/1.3544658
    • (2011) Med. Phys. , vol.38 , pp. 1196-1206
    • Lee, C.1    Kim, K.P.2    Long, D.3    Fisher, R.4    Tien, C.5    Simon, S.L.6    Bouville, A.7    Bolch, W.E.8
  • 14
    • 40049093127 scopus 로고    scopus 로고
    • Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy
    • 10.1118/1.2839096
    • G. X. Ding, D. M. Duggan, and C. W. Coffey, " Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy.," Med. Phys. 35, 1135-1144 (2008). 10.1118/1.2839096
    • (2008) Med. Phys. , vol.35 , pp. 1135-1144
    • Ding, G.X.1    Duggan, D.M.2    Coffey, C.W.3
  • 15
    • 70450270835 scopus 로고    scopus 로고
    • Review of computational anthropomorphic anatomical and physiological models
    • 10.1109/JPROC.2009.2032852
    • H. Zaidi, and B. M. W. Tsui, " Review of computational anthropomorphic anatomical and physiological models.," Proc. IEEE 97, 1938-1953 (2009). 10.1109/JPROC.2009.2032852
    • (2009) Proc. IEEE , vol.97 , pp. 1938-1953
    • Zaidi, H.1    Tsui, B.M.W.2
  • 16
    • 80052657095 scopus 로고    scopus 로고
    • Development and validation of a hybrid simulation technique for cone beam CT: Application to an oral imaging system
    • 10.1088/0031-9155/56/18/004
    • G. Zhang, R. Pauwels, N. Marshall, E. Shaheen, J. Nuyts, R. Jacobs, and H. Bosmans, " Development and validation of a hybrid simulation technique for cone beam CT: Application to an oral imaging system.," Phys. Med. Biol. 56, 5823-5843 (2011). 10.1088/0031-9155/56/18/004
    • (2011) Phys. Med. Biol. , vol.56 , pp. 5823-5843
    • Zhang, G.1    Pauwels, R.2    Marshall, N.3    Shaheen, E.4    Nuyts, J.5    Jacobs, R.6    Bosmans, H.7
  • 17
    • 79953677265 scopus 로고    scopus 로고
    • ICRP Publication 110: Adult reference computational phantoms
    • International Commission on Radiological Protection;, 10.1016/j.icr2009.07.001
    • International Commission on Radiological Protection, " ICRP Publication 110: Adult reference computational phantoms.," Ann. ICRP 39, 1-166 (2009). 10.1016/j.icrp.2009.07.001
    • (2009) Ann. ICRP , vol.39 , pp. 1-166
  • 18
    • 0038413486 scopus 로고    scopus 로고
    • ICRP Publication 89: Basic anatomical and physiological data for use in radiological protection: Reference values
    • International Commission on Radiological Protection;, 10.1016/S0146-6453(03)00002-2
    • International Commission on Radiological Protection, " ICRP Publication 89: Basic anatomical and physiological data for use in radiological protection: Reference values.," Ann. ICRP 32, 1-277 (2002). 10.1016/S0146-6453(03)00002-2
    • (2002) Ann. ICRP , vol.32 , pp. 1-277
  • 19
  • 20
    • 36949039788 scopus 로고    scopus 로고
    • The development and application of the visible Chinese human model for Monte Carlo dose calculations
    • 10.1097/01.HP.0000285256.48498.b4
    • G. Zhang, Q. Luo, S. Zeng, and Q. Liu, " The development and application of the visible Chinese human model for Monte Carlo dose calculations.," Health Phys. 94, 118-125 (2008). 10.1097/01.HP.0000285256. 48498.b4
    • (2008) Health Phys. , vol.94 , pp. 118-125
    • Zhang, G.1    Luo, Q.2    Zeng, S.3    Liu, Q.4
  • 21
    • 0004286738 scopus 로고    scopus 로고
    • NRCC Report No. PIRS-0509(A)revK (National Research Council, Ottawa, Canada)
    • D. W. O. Rogers, B. Walters, and I. Kawrakow, " BEAMnrc users manual.," NRCC Report No. PIRS-0509(A)revK (National Research Council, Ottawa, Canada, 2009).
    • (2009) BEAMnrc Users Manual
    • Rogers, D.W.O.1    Walters, B.2    Kawrakow, I.3
  • 23
    • 0036908431 scopus 로고    scopus 로고
    • History by history statistical estimators in the BEAM code system
    • 10.1118/1.1517611
    • B. R. B. Walters, I. Kawrakow, and D. W. O. Rogers, " History by history statistical estimators in the BEAM code system.," Med. Phys. 29, 2745-2752 (2002). 10.1118/1.1517611
    • (2002) Med. Phys. , vol.29 , pp. 2745-2752
    • Walters, B.R.B.1    Kawrakow, I.2    Rogers, D.W.O.3
  • 24
    • 24044530743 scopus 로고    scopus 로고
    • A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): Cylindrical and anthropomorphic phantoms
    • 10.1088/0031-9155/50/17/005
    • J. J. DeMarco, C. H. Cagnon, D. D. Cody, D. M. Stevens, C. H. McCollough, J. O'Daniel, and M. F. McNitt-Gray, " A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): Cylindrical and anthropomorphic phantoms.," Phys. Med. Biol. 50, 3989-4004 (2005). 10.1088/0031-9155/50/17/005
    • (2005) Phys. Med. Biol. , vol.50 , pp. 3989-4004
    • Demarco, J.J.1    Cagnon, C.H.2    Cody, D.D.3    Stevens, D.M.4    McCollough, C.H.5    O'Daniel, J.6    McNitt-Gray, M.F.7
  • 25
    • 40949104442 scopus 로고    scopus 로고
    • ICRP Publication 103: The 2007 recommendations of the International Commission on Radiological Protection
    • International Commission on Radiological Protection;, 10.1016/j.icr2007.11.001
    • International Commission on Radiological Protection, " ICRP Publication 103: The 2007 recommendations of the International Commission on Radiological Protection.," Ann. ICRP 37, 1-332 (2007). 10.1016/j.icrp.2007. 11.001
    • (2007) Ann. ICRP , vol.37 , pp. 1-332
  • 26
    • 84857260226 scopus 로고    scopus 로고
    • Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms
    • the SEDENTEXCT Project Consortium;, 10.1259/bjr/19389412
    • C. Theodorakou, A. Walker, K. Horner, R. Pauwels, R. Bogaerts, R. Jacobs, and the SEDENTEXCT Project Consortium, " Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms.," Br. J. Radiol. 85, 153-160 (2012). 10.1259/bjr/19389412
    • (2012) Br. J. Radiol. , vol.85 , pp. 153-160
    • Theodorakou, C.1    Walker, A.2    Horner, K.3    Pauwels, R.4    Bogaerts, R.5    Jacobs, R.6
  • 28
    • 0037151130 scopus 로고    scopus 로고
    • Organ dose conversion coefficients for external photon irradiation of male and female voxel models
    • 10.1088/0031-9155/47/14/301
    • M. Zankl, U. Fill, N. Petoussi-Henss, and D. Regulla, " Organ dose conversion coefficients for external photon irradiation of male and female voxel models.," Phys. Med. Biol. 47, 2367-2385 (2002). 10.1088/0031-9155/47/14/ 301
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2367-2385
    • Zankl, M.1    Fill, U.2    Petoussi-Henss, N.3    Regulla, D.4
  • 29
    • 0038459031 scopus 로고    scopus 로고
    • All about MAX: A male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry
    • 10.1088/0031-9155/48/10/301
    • R. Kramer, J. W. Vieira, H. J. Khoury, F. R. Lima, and D. Fuelle, " All about MAX: A male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry.," Phys. Med. Biol. 48, 1239-1262 (2003). 10.1088/0031-9155/48/10/301
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1239-1262
    • Kramer, R.1    Vieira, J.W.2    Khoury, H.J.3    Lima, F.R.4    Fuelle, D.5
  • 31
    • 0021954160 scopus 로고
    • Photoelectron enhancement of the absorbed dose from x-rays to human bone marrow: Experimental and theoretical studies
    • 10.1259/0007-1285-58-688-345
    • S. D. King and F. W. Spiers, " Photoelectron enhancement of the absorbed dose from x-rays to human bone marrow: Experimental and theoretical studies.," Br. J. Radiol. 58, 345-356 (1985). 10.1259/0007-1285-58-688-345
    • (1985) Br. J. Radiol. , vol.58 , pp. 345-356
    • King, S.D.1    Spiers, F.W.2
  • 32
    • 0034451289 scopus 로고    scopus 로고
    • Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations
    • 10.1109/23.901179
    • H. Zaidi, " Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations.," IEEE Trans. Nucl. Sci. 47, 2722-2735 (2000). 10.1109/23.901179
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 2722-2735
    • Zaidi, H.1
  • 33
    • 0033059292 scopus 로고    scopus 로고
    • MIRD Pamphlet No. 15: Radionuclide S values in a revised dosimetric model of the adult head and brain
    • L. G. Bouchet, W. E. Bolch, D. A. Weber, H. L. Atkins HL, and J. W. Poston Sr., " MIRD Pamphlet No. 15: Radionuclide S values in a revised dosimetric model of the adult head and brain.," J. Nucl. Med. 40, 62S-101S (1999).
    • (1999) J. Nucl. Med. , vol.40
    • Bouchet, L.G.1    Bolch, W.E.2    Weber, D.A.3    Atkins Hl, H.L.4    Poston Sr., J.W.5
  • 34
    • 77953902483 scopus 로고    scopus 로고
    • Deformable adult human phantoms for radiation protection dosimetry: Anthropometric data representing size distributions of adult worker populations and software algorithms
    • 10.1088/0031-9155/55/13/015
    • Y. H. Na, B. Zhang, J. Zhang, P. F. Caracappa, and X. G. Xu, " Deformable adult human phantoms for radiation protection dosimetry: Anthropometric data representing size distributions of adult worker populations and software algorithms.," Phys. Med. Biol. 55, 3789-3811 (2010). 10.1088/0031-9155/55/13/015
    • (2010) Phys. Med. Biol. , vol.55 , pp. 3789-3811
    • Na, Y.H.1    Zhang, B.2    Zhang, J.3    Caracappa, P.F.4    Xu, X.G.5