메뉴 건너뛰기




Volumn 49, Issue 7, 2014, Pages 465-473

Ultralow-dose chest computed tomography for pulmonary nodule detection: First performance evaluation of single energy scanning with spectral shaping

Author keywords

computed tomography; image reconstruction; low dose; lung; radiation dosage

Indexed keywords

ADULT; ARTICLE; CASE REPORT; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; DOUBLE BLIND PROCEDURE; ELECTRIC POTENTIAL; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; LUNG NODULE; MALE; NOISE; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; RADIATION RESPONSE; ALGORITHM; COMPUTER ASSISTED DIAGNOSIS; EVALUATION STUDY; MIDDLE AGED; PILOT STUDY; PROCEDURES; RADIATION PROTECTION; RADIOGRAPHY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; THORAX RADIOGRAPHY;

EID: 84902172225     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0000000000000037     Document Type: Article
Times cited : (215)

References (35)
  • 1
    • 78549240639 scopus 로고    scopus 로고
    • Dose reduction strategies for thoracicmultidetector computed tomography: Background, current issues, and recommendations
    • Bankier AA, Tack D. Dose reduction strategies for thoracicmultidetector computed tomography: background, current issues, and recommendations. J Thorac Imaging. 2010;25:278-288.
    • (2010) J Thorac Imaging , vol.25 , pp. 278-288
    • Bankier, A.A.1    Tack, D.2
  • 2
    • 44649159674 scopus 로고    scopus 로고
    • Technical approaches to the optimisation of CT
    • Kalender WA, Buchenau S, Deak P, et al. Technical approaches to the optimisation of CT. Phys Med. 2008;24:71-79.
    • (2008) Phys Med , vol.24 , pp. 71-79
    • Kalender, W.A.1    Buchenau, S.2    Deak, P.3
  • 3
    • 74749092491 scopus 로고    scopus 로고
    • Dose reduction in helical CT: Dynamically adjustable z-Axis X-ray beam collimation
    • Christner JA, Zavaletta VA, Eusemann CD, et al. Dose reduction in helical CT: dynamically adjustable z-Axis X-ray beam collimation. AJR Am J Roentgenol. 2010;194:W49-W55.
    • (2010) AJR Am J Roentgenol , vol.194
    • Christner, J.A.1    Zavaletta, V.A.2    Eusemann, C.D.3
  • 4
    • 79952440432 scopus 로고    scopus 로고
    • Computed tomography of the lung in the high-pitch mode: Is breath holding still required?
    • Baumueller S, Alkadhi H, Stolzmann P, et al. Computed tomography of the lung in the high-pitch mode: is breath holding still required? Invest Radiol. 2011;46:240-245.
    • (2011) Invest Radiol , vol.46 , pp. 240-245
    • Baumueller, S.1    Alkadhi, H.2    Stolzmann, P.3
  • 5
    • 76849115619 scopus 로고    scopus 로고
    • The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT
    • Paul NS, Blobel J, Prezelj E, et al. The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT. Phys Med Biol. 2010;55:1363-1380.
    • (2010) Phys Med Biol , vol.55 , pp. 1363-1380
    • Paul, N.S.1    Blobel, J.2    Prezelj, E.3
  • 6
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • Thibault JB, Sauer KD, Bouman CA, et al. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007; 34:4526-4544. (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 8
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection, part 1: Evaluation of image noise reduction in 32 patients
    • Pontana F, Pagniez J, Flohr T, et al. Chest computed tomography using iterative reconstruction vs filtered back projection, part 1: evaluation of image noise reduction in 32 patients. Eur Radiol. 2011;21:627-635.
    • (2011) Eur Radiol , vol.21 , pp. 627-635
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 9
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection, part 2: Image quality of low-dose CT examinations in 80 patients
    • Pontana F, Duhamel A, Pagniez J, et al. Chest computed tomography using iterative reconstruction vs filtered back projection, part 2: image quality of low-dose CT examinations in 80 patients. Eur Radiol. 2011;21:636-643.
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3
  • 10
    • 77953939681 scopus 로고    scopus 로고
    • Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Ackman JB, et al. Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology. 2010; 256:261-269.
    • (2010) Radiology , vol.256 , pp. 261-269
    • Prakash, P.1    Kalra, M.K.2    Ackman, J.B.3
  • 11
    • 77956490090 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for pulmonary CT: Image quality of the cadaveric lung on standard- and reduced-dose CT
    • Yanagawa M, Honda O, Yoshida S, et al. Adaptive statistical iterative reconstruction technique for pulmonary CT: image quality of the cadaveric lung on standard- and reduced-dose CT. Acad Radiol. 2010;17:1259-1266.
    • (2010) Acad Radiol , vol.17 , pp. 1259-1266
    • Yanagawa, M.1    Honda, O.2    Yoshida, S.3
  • 12
    • 78649700320 scopus 로고    scopus 로고
    • A prospective evaluation of dose reduction and image quality in chest CTusing adaptive statistical iterative reconstruction
    • Leipsic J, Nguyen G, Brown J, et al. A prospective evaluation of dose reduction and image quality in chest CTusing adaptive statistical iterative reconstruction. AJR Am J Roentgenol. 2010;195:1095-1099.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1095-1099
    • Leipsic, J.1    Nguyen, G.2    Brown, J.3
  • 13
    • 84870380018 scopus 로고    scopus 로고
    • Low-dose CTof the lung: Potential value of iterative reconstructions
    • Baumueller S,Winklehner A, Karlo C, et al. Low-dose CTof the lung: potential value of iterative reconstructions. Eur Radiol. 2012;22:2597-2606.
    • (2012) Eur Radiol , vol.22 , pp. 2597-2606
    • Baumueller, S.1    Winklehner, A.2    Karlo, C.3
  • 14
    • 84863229324 scopus 로고    scopus 로고
    • The National Lung Screening Trial: Overview and study design
    • Aberle DR, Berg CD, Black WC, et al. The National Lung Screening Trial: overview and study design. Radiology. 2011;258:243-253.
    • (2011) Radiology , vol.258 , pp. 243-253
    • Aberle, D.R.1    Berg, C.D.2    Black, W.C.3
  • 15
    • 74049135424 scopus 로고    scopus 로고
    • Characterization of urinary stones with dual-energy CT: Improved differentiation using a tin filter
    • Stolzmann P, Leschka S, Scheffel H, et al. Characterization of urinary stones with dual-energy CT: improved differentiation using a tin filter. Invest Radiol. 2010;45:1-6.
    • (2010) Invest Radiol , vol.45 , pp. 1-6
    • Stolzmann, P.1    Leschka, S.2    Scheffel, H.3
  • 16
    • 84871614856 scopus 로고    scopus 로고
    • Stenosis quantification in coronary CT angiography: Impact of an integrated circuit detector with iterative reconstruction
    • Morsbach F, Desbiolles L, Plass A, et al. Stenosis quantification in coronary CT angiography: impact of an integrated circuit detector with iterative reconstruction. Invest Radiol. 2013;48:32-40.
    • (2013) Invest Radiol , vol.48 , pp. 32-40
    • Morsbach, F.1    Desbiolles, L.2    Plass, A.3
  • 17
    • 0027568637 scopus 로고
    • Preconditioning methods for improved convergence rates in iterative reconstructions
    • Clinthorne NH, Pan TS, Chiao PC, et al. Preconditioning methods for improved convergence rates in iterative reconstructions. IEEE Trans Med Imaging. 1993; 12:78-83.
    • (1993) IEEE Trans Med Imaging , vol.12 , pp. 78-83
    • Clinthorne, N.H.1    Pan, T.S.2    Chiao, P.C.3
  • 18
    • 84896319616 scopus 로고    scopus 로고
    • Intraindividual comparison of diagnostic performance in patients with hepatic metastasis of full-dose standard and halfdose iterative reconstructions with dual-source abdominal computed tomography
    • Park M, Chung YE, Lee HS, et al. Intraindividual comparison of diagnostic performance in patients with hepatic metastasis of full-dose standard and halfdose iterative reconstructions with dual-source abdominal computed tomography. Invest Radiol. 2014;49:195-200.
    • (2014) Invest Radiol , vol.49 , pp. 195-200
    • Park, M.1    Chung, Y.E.2    Lee, H.S.3
  • 21
    • 0141841669 scopus 로고    scopus 로고
    • Detection of pulmonary nodules by multislice computed tomography: Improved detection rate with reduced slice thickness
    • DOI 10.1007/s00330-003-1915-7
    • Fischbach F, Knollmann F, Griesshaber V, et al. Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol. 2003;13:2378-2383. (Pubitemid 37220375)
    • (2003) European Radiology , vol.13 , Issue.10 , pp. 2378-2383
    • Fischbach, F.1    Knollman, F.2    Griesshaber, V.3    Freund, T.4    Akkol, E.5    Felix, R.6
  • 22
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174. (Pubitemid 8054849)
    • (1977) Biometrics , vol.33 , Issue.1 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 23
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: A pilot study
    • Singh S, KalraMK, GilmanMD, et al. Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011;259:565-573.
    • (2011) Radiology , vol.259 , pp. 565-573
    • Singh, S.1    Gilmanmd, K.2
  • 24
    • 84864693212 scopus 로고    scopus 로고
    • Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults
    • Desai GS, Uppot RN, Yu EW, et al. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults. Eur Radiol. 2012;22:1631-1640.
    • (2012) Eur Radiol , vol.22 , pp. 1631-1640
    • Desai, G.S.1    Uppot, R.N.2    Yu, E.W.3
  • 25
    • 84863666413 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: A pilot study
    • Yamada Y, Jinzaki M, Tanami Y, et al. Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study. Invest Radiol. 2012;47:482-489.
    • (2012) Invest Radiol , vol.47 , pp. 482-489
    • Yamada, Y.1    Jinzaki, M.2    Tanami, Y.3
  • 26
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose chest CT: Comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M, et al. Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Invest Radiol. 2013;48:206-212.
    • (2013) Invest Radiol , vol.48 , pp. 206-212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 27
    • 84878598953 scopus 로고    scopus 로고
    • Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: Preliminary observations
    • Neroladaki A, Botsikas D, Boudabbous S, et al. Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur Radiol. 2013;23:360-366.
    • (2013) Eur Radiol , vol.23 , pp. 360-366
    • Neroladaki, A.1    Botsikas, D.2    Boudabbous, S.3
  • 28
    • 84885184175 scopus 로고    scopus 로고
    • Effect of radiation dose and iterative reconstruction on lung lesion conspicuity atMDCT does one size fit all?
    • Botelho MP, Agrawal R, Gonzalez-Guindalini FD, et al. Effect of radiation dose and iterative reconstruction on lung lesion conspicuity atMDCT: does one size fit all? Eur J Radiol. 2013;82:e726-e733.
    • (2013) Eur J Radiol , vol.82
    • Botelho, M.P.1    Agrawal, R.2    Gonzalez-Guindalini, F.D.3
  • 29
    • 84890428743 scopus 로고    scopus 로고
    • Comparative study between mobile computed radiography and mobile flat-panel radiography for bedside chest radiography: Impact of an antiscatter grid on the visibility of selected diagnostically relevant structures
    • Lehnert T, Naguib NN, Wutzler S, et al. Comparative study between mobile computed radiography and mobile flat-panel radiography for bedside chest radiography: impact of an antiscatter grid on the visibility of selected diagnostically relevant structures. Invest Radiol. 2014;49:1-6.
    • (2014) Invest Radiol , vol.49 , pp. 1-6
    • Lehnert, T.1    Naguib, N.N.2    Wutzler, S.3
  • 30
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • Mettler FA Jr., Huda W, Yoshizumi TT, et al. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology. 2008;248:254-263.
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler Jr., F.A.1    Huda, W.2    Yoshizumi, T.T.3
  • 31
    • 80052962265 scopus 로고    scopus 로고
    • Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space
    • Hu XH, Ding XF, Wu RZ, et al. Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space. Clin Radiol. 2011;66:1023-1029.
    • (2011) Clin Radiol , vol.66 , pp. 1023-1029
    • Hu, X.H.1    Ding, X.F.2    Wu, R.Z.3
  • 32
    • 83555174941 scopus 로고    scopus 로고
    • Raw data-based iterative reconstruction in body CTA: Evaluation of radiation dose saving potential
    • Winklehner A, Karlo C, Puippe G, et al. Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol. 2011;21:2521-2526.
    • (2011) Eur Radiol , vol.21 , pp. 2521-2526
    • Winklehner, A.1    Karlo, C.2    Puippe, G.3
  • 33
    • 84866987989 scopus 로고    scopus 로고
    • Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection
    • Wang R, Schoepf UJ,Wu R, et al. Image quality and radiation dose of low dose coronary CT angiography in obese patients: sinogram affirmed iterative reconstruction versus filtered back projection. Eur J Radiol. 2012;81:3141-3145.
    • (2012) Eur J Radiol , vol.81 , pp. 3141-3145
    • Wang, R.1    Schoepf Ujwu, R.2
  • 34
    • 84883735350 scopus 로고    scopus 로고
    • Sinogram-Affirmed iterative reconstruction of low-dose chest CT: Effect on image quality and radiation dose
    • Kalra MK, Woisetschlager M, Dahlstrom N, et al. Sinogram-Affirmed iterative reconstruction of low-dose chest CT: effect on image quality and radiation dose. AJR Am J Roentgenol. 2013;201:W235-W244.
    • (2013) AJR Am J Roentgenol , vol.201
    • Kalra, M.K.1    Woisetschlager, M.2    Dahlstrom, N.3
  • 35
    • 84886703834 scopus 로고    scopus 로고
    • Pure and part-solid pulmonary ground-glass nodules: Measurement variability of volume and mass in nodules with a solid portion less than or equal to 5 mm
    • Kim H, Park CM, Woo S, et al. Pure and part-solid pulmonary ground-glass nodules: measurement variability of volume and mass in nodules with a solid portion less than or equal to 5 mm. Radiology. 2013;269:585-593.
    • (2013) Radiology , vol.269 , pp. 585-593
    • Kim, H.1    Park, C.M.2    Woo, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.