메뉴 건너뛰기




Volumn 17, Issue 10, 2010, Pages 1259-1266

Adaptive statistical iterative reconstruction technique for pulmonary CT. Image quality of the cadaveric lung on standard- and reduced-dose CT

Author keywords

Adaptive statistical iterative reconstruction (ASIR); Cadaveric lung; Computed tomography (CT)

Indexed keywords

ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION; ARTICLE; BRONCHIOLITIS; CADAVER; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERSTITIAL PNEUMONIA; LUNG CARCINOMA; LUNG EMPHYSEMA; LUNG HEMORRHAGE; LUNG INJURY; LUNG METASTASIS; LUNG SCINTISCANNING; LUNG TUBERCULOSIS; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; RANK SUM TEST;

EID: 77956490090     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2010.05.014     Document Type: Article
Times cited : (58)

References (22)
  • 1
    • 0141841669 scopus 로고    scopus 로고
    • Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness
    • Fischbach F., Knollmann F., Griesshaber V., et al. Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 2003, 13:2378-2383.
    • (2003) Eur Radiol , vol.13 , pp. 2378-2383
    • Fischbach, F.1    Knollmann, F.2    Griesshaber, V.3
  • 2
    • 42149166777 scopus 로고    scopus 로고
    • Investigation of airways using MDCT for visual and quantitative assessment in COPD patients
    • Brillet P.Y., Fetita C.I., Saragaglia A., et al. Investigation of airways using MDCT for visual and quantitative assessment in COPD patients. Int J Chron Obstruct Pulmon Dis 2008, 3:97-107.
    • (2008) Int J Chron Obstruct Pulmon Dis , vol.3 , pp. 97-107
    • Brillet, P.Y.1    Fetita, C.I.2    Saragaglia, A.3
  • 3
    • 0034330627 scopus 로고    scopus 로고
    • Multisection CT: scanning techniques and clinical applications
    • Rydberg J., Buckwalter K.A., Caldemeyer K.S., et al. Multisection CT: scanning techniques and clinical applications. Radiographics 2000, 20:1787-1806.
    • (2000) Radiographics , vol.20 , pp. 1787-1806
    • Rydberg, J.1    Buckwalter, K.A.2    Caldemeyer, K.S.3
  • 4
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys 1999, 26:5-18.
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 5
    • 77952735624 scopus 로고    scopus 로고
    • Multidetector CT of the lung: image quality with garnet-based detectors
    • Yanagawa M., Tomiyama N., Osamu H., et al. Multidetector CT of the lung: image quality with garnet-based detectors. Radiology 2010, 255:944-954.
    • (2010) Radiology , vol.255 , pp. 944-954
    • Yanagawa, M.1    Tomiyama, N.2    Osamu, H.3
  • 6
    • 0031932289 scopus 로고    scopus 로고
    • Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction
    • Pretorius P.H., King M.A., Pan T.S., et al. Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction. Phys Med Biol 1998, 43:407-420.
    • (1998) Phys Med Biol , vol.43 , pp. 407-420
    • Pretorius, P.H.1    King, M.A.2    Pan, T.S.3
  • 7
    • 0033881834 scopus 로고    scopus 로고
    • Comparing filtered backprojection and ordered-subsets expectation maximization for small-lesion detection and localization in 67Ga SPECT
    • Wells R.G., King M.A., Simkin P.H., et al. Comparing filtered backprojection and ordered-subsets expectation maximization for small-lesion detection and localization in 67Ga SPECT. J Nucl Med 2000, 41:1391-1399.
    • (2000) J Nucl Med , vol.41 , pp. 1391-1399
    • Wells, R.G.1    King, M.A.2    Simkin, P.H.3
  • 8
    • 0029934050 scopus 로고    scopus 로고
    • A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography
    • Knesaurek K., Machac J., Vallabhajosula S., et al. A new iterative reconstruction technique for attenuation correction in high-resolution positron emission tomography. Eur J Nucl Med 1996, 23:656-661.
    • (1996) Eur J Nucl Med , vol.23 , pp. 656-661
    • Knesaurek, K.1    Machac, J.2    Vallabhajosula, S.3
  • 9
    • 0034857453 scopus 로고    scopus 로고
    • Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment
    • Riddell C., Carson R.E., Carrasquillo J.A., et al. Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment. J Nucl Med 2001, 42:1316-1323.
    • (2001) J Nucl Med , vol.42 , pp. 1316-1323
    • Riddell, C.1    Carson, R.E.2    Carrasquillo, J.A.3
  • 10
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • Thibault J.B., Sauer K.D., Bouman C.A., et al. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 2007, 34:4526-4544.
    • (2007) Med Phys , vol.34 , pp. 4526-4544
    • Thibault, J.B.1    Sauer, K.D.2    Bouman, C.A.3
  • 11
    • 33846593569 scopus 로고    scopus 로고
    • Fast variance image predictions for quadratically regularized statistical image reconstruction in fan-beam tomography
    • Zhang Y., Fessier J., Hsieh J. Fast variance image predictions for quadratically regularized statistical image reconstruction in fan-beam tomography. IEEE Nuclear Science Symp Conf 2005, 4:4.
    • (2005) IEEE Nuclear Science Symp Conf , vol.4 , pp. 4
    • Zhang, Y.1    Fessier, J.2    Hsieh, J.3
  • 12
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • Marin D., Nelson R.C., Schindera S.T., et al. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 2010, 254:145-153.
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 14
    • 0029894886 scopus 로고    scopus 로고
    • Glossary of terms for CT of the lung: recommendations of the Nomenclature Committee of the Fleischner Society
    • Austin J.H.M., Müller N.L., Friedman P.J., et al. Glossary of terms for CT of the lung: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 1996, 200:327-331.
    • (1996) Radiology , vol.200 , pp. 327-331
    • Austin, J.H.M.1    Müller, N.L.2    Friedman, P.J.3
  • 15
    • 0142147379 scopus 로고    scopus 로고
    • Thin-section CT of the lung: dose electrocardiographic triggering influence diagnosis?
    • Boehm T., Willmann J.K., Hilfiker P.R., et al. Thin-section CT of the lung: dose electrocardiographic triggering influence diagnosis?. Radiology 2003, 229:483-491.
    • (2003) Radiology , vol.229 , pp. 483-491
    • Boehm, T.1    Willmann, J.K.2    Hilfiker, P.R.3
  • 16
    • 36849020401 scopus 로고    scopus 로고
    • Principles of CT: radiation dose and image quality
    • Goldman L.W. Principles of CT: radiation dose and image quality. J Nucl Med Technol 2007, 35:213-225.
    • (2007) J Nucl Med Technol , vol.35 , pp. 213-225
    • Goldman, L.W.1
  • 17
    • 0023950428 scopus 로고
    • Optimization of computed tomography technique to demonstrate the fine structure of the lung
    • Murata K., Khan A., Rojas K.A., et al. Optimization of computed tomography technique to demonstrate the fine structure of the lung. Invest Radiol 1988, 23:170-175.
    • (1988) Invest Radiol , vol.23 , pp. 170-175
    • Murata, K.1    Khan, A.2    Rojas, K.A.3
  • 18
    • 0023220989 scopus 로고
    • High-resolution CT of the lungs: an optimal approach
    • Mayo J.R., Webb W.R., Gould R., et al. High-resolution CT of the lungs: an optimal approach. Radiology 1987, 163:507-510.
    • (1987) Radiology , vol.163 , pp. 507-510
    • Mayo, J.R.1    Webb, W.R.2    Gould, R.3
  • 19
    • 0024369374 scopus 로고
    • High-spatial-frequency (bone) algorithm improves quality of standard CT of the thorax
    • Zwirewich C.V., Terriff B., Müller N.L. High-spatial-frequency (bone) algorithm improves quality of standard CT of the thorax. AJR Am J Roentgenol 1989, 153:1169-1173.
    • (1989) AJR Am J Roentgenol , vol.153 , pp. 1169-1173
    • Zwirewich, C.V.1    Terriff, B.2    Müller, N.L.3
  • 20
    • 0019364103 scopus 로고
    • The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies
    • Haaga J.R., Miraldi F., MacIntyre W., et al. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology 1981, 138:449-454.
    • (1981) Radiology , vol.138 , pp. 449-454
    • Haaga, J.R.1    Miraldi, F.2    MacIntyre, W.3
  • 21
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study
    • Hara A.K., Paden R.G., Silva A.C., et al. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 2009, 193:764-771.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3
  • 22
    • 58149489769 scopus 로고    scopus 로고
    • Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions
    • Yanagawa M., Tomiyama N., Sumikawa H., et al. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions. Eur J Radiol 2009, 69:102-107.
    • (2009) Eur J Radiol , vol.69 , pp. 102-107
    • Yanagawa, M.1    Tomiyama, N.2    Sumikawa, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.