메뉴 건너뛰기




Volumn 45, Issue 1, 2010, Pages 1-6

Characterization of urinary stones with dual-energy CT: Improved differentiation using a tin filter

Author keywords

Computed tomography; Crystallography; Dual energy; Ex vivo; Uric acid; Urinary stone

Indexed keywords

TIN; URIC ACID;

EID: 74049135424     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181b9dbed     Document Type: Article
Times cited : (86)

References (20)
  • 2
    • 35748964243 scopus 로고    scopus 로고
    • Uric acid nephrolithiasis: Recent progress and future directions
    • Ngo TC, Assimos DG. Uric acid nephrolithiasis: recent progress and future directions. Rev Urol. 2007;9:17-27.
    • (2007) Rev Urol , vol.9 , pp. 17-27
    • Ngo, T.C.1    Assimos, D.G.2
  • 4
    • 36148936386 scopus 로고    scopus 로고
    • Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT
    • Primak AN, Fletcher JG, Vrtiska TJ, et al. Noninvasive differentiation of uric acid versus non-uric acid kidney stones using dual-energy CT. Acad Radiol. 2007;14:1441-1447.
    • (2007) Acad Radiol , vol.14 , pp. 1441-1447
    • Primak, A.N.1    Fletcher, J.G.2    Vrtiska, T.J.3
  • 5
    • 38149109994 scopus 로고    scopus 로고
    • Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience
    • Graser A, Johnson TR, Bader M, et al. Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol. 2008; 43:112-119.
    • (2008) Invest Radiol , vol.43 , pp. 112-119
    • Graser, A.1    Johnson, T.R.2    Bader, M.3
  • 6
    • 48349118166 scopus 로고    scopus 로고
    • Dual-energy computed tomography for the differentiation of uric acid stones: Ex vivo performance evaluation
    • Stolzmann P, Scheffel H, Rentsch K, et al. Dual-energy computed tomography for the differentiation of uric acid stones: ex vivo performance evaluation. Urol Res. 2008;36:133-138.
    • (2008) Urol Res , vol.36 , pp. 133-138
    • Stolzmann, P.1    Scheffel, H.2    Rentsch, K.3
  • 7
    • 62649160055 scopus 로고    scopus 로고
    • Renal stone assessment with dual-energy multidetector CT and advanced postprocessing techniques: Improved characterization of renal stone composition-pilot study
    • Boll DT, Patil NA, Paulson EK, et al. Renal stone assessment with dual-energy multidetector CT and advanced postprocessing techniques: improved characterization of renal stone composition-pilot study. Radiology. 2009;250: 813-820.
    • (2009) Radiology , vol.250 , pp. 813-820
    • Boll, D.T.1    Patil, N.A.2    Paulson, E.K.3
  • 8
    • 54449083246 scopus 로고    scopus 로고
    • Dual source computed tomography: A novel technique to determine stone composition
    • Matlaga BR, Kawamoto S, Fishman E. Dual source computed tomography: a novel technique to determine stone composition. Urology. 2008;72:1164-1168.
    • (2008) Urology , vol.72 , pp. 1164-1168
    • Matlaga, B.R.1    Kawamoto, S.2    Fishman, E.3
  • 9
    • 58949099700 scopus 로고    scopus 로고
    • Dual-energy and dual-source CT: Is there a role in the abdomen and pelvis?
    • Fletcher JG, Takahashi N, Hartman R, et al. Dual-energy and dual-source CT: is there a role in the abdomen and pelvis? Radiol Clin North Am. 2009;47: 41-57.
    • (2009) Radiol Clin North Am , vol.47 , pp. 41-57
    • Fletcher, J.G.1    Takahashi, N.2    Hartman, R.3    Al, E.4
  • 10
    • 78651226455 scopus 로고    scopus 로고
    • Vivo identification of uric acid stones with dual-energy CT: Diagnostic performance evaluation in patients
    • Sep 2:[Epub ahead of print]
    • Stolzmann P, Kozomara M, Chuck N, et al. In vivo identification of uric acid stones with dual-energy CT: diagnostic performance evaluation in patients. Abdom Imaging. 2009;Sep 2:[Epub ahead of print].
    • (2009) Abdom Imaging
    • Stolzmann, P.1    Kozomara, M.2    Chuck, N.3    Al, E.4
  • 11
    • 36248997114 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease
    • Scheffel H, Stolzmann P, Frauenfelder T, et al. Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease. Invest Radiol. 2007;42:823-829.
    • (2007) Invest Radiol , vol.42 , pp. 823-829
    • Scheffel, H.1    Stolzmann, P.2    Frauenfelder, T.3
  • 12
    • 56149116093 scopus 로고    scopus 로고
    • Endoleaks after endovas-cular abdominal aortic aneurysm repair: Detection with dual-energy dual-source CT
    • Stolzmann P, Frauenfelder T, Pfammatter T, et al. Endoleaks after endovas-cular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology. 2008;249:682-691.
    • (2008) Radiology , vol.249 , pp. 682-691
    • Stolzmann, P.1    Frauenfelder, T.2    Pfammatter, T.3
  • 13
    • 67349191462 scopus 로고    scopus 로고
    • Dual-energy CT for the characterization of urinary calculi: In vitro and in vivo evaluation of a low-dose scanning protocol
    • Thomas C, Patschan O, Ketelsen D, et al. Dual-energy CT for the characterization of urinary calculi: in vitro and in vivo evaluation of a low-dose scanning protocol. Eur Radiol. 2009;19:1553-1559.
    • (2009) Eur Radiol , vol.19 , pp. 1553-1559
    • Thomas, C.1    Patschan, O.2    Ketelsen, D.3
  • 14
    • 64249100198 scopus 로고    scopus 로고
    • Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: A phantom feasibility study
    • Brown CL, Hartman RP, Dzyubak OP, et al. Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol. 2009;19:1289-1295.
    • (2009) Eur Radiol , vol.19 , pp. 1289-1295
    • Brown, C.L.1    Hartman, R.P.2    Dzyubak, O.P.3
  • 15
    • 65349110338 scopus 로고    scopus 로고
    • Image fusion in dual energy computed tomography: Effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography
    • Behrendt FF, Schmidt B, Plumhans C, et al. Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography. Invest Radiol. 2009;44:1-6.
    • (2009) Invest Radiol , vol.44 , pp. 1-6
    • Behrendt, F.F.1    Schmidt, B.2    Plumhans, C.3
  • 16
    • 37549003683 scopus 로고    scopus 로고
    • Conventional and reduced radiation dose of 16-MDCT for detection of nephrolithiasis and ureterolithiasis
    • Paulson EK, Weaver C, Ho LM, et al. Conventional and reduced radiation dose of 16-MDCT for detection of nephrolithiasis and ureterolithiasis. Am J Roentgenol. 2008;190:151-157.
    • (2008) Am J Roentgenol , vol.190 , pp. 151-157
    • Paulson, E.K.1    Weaver, C.2    Ho, L.M.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006;16:256-268.
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 19
    • 0037038947 scopus 로고    scopus 로고
    • An energy-based beam hardening model in tomography
    • Van de Casteele E, Van Dyck D, Sijbers J, et al. An energy-based beam hardening model in tomography. Phys Med Biol. 2002;47:4181-4190.
    • (2002) Phys Med Biol , vol.47 , pp. 4181-4190
    • Van De Casteele, E.1    Van Dyck, D.2    Sijbers, J.3
  • 20
    • 39749113025 scopus 로고    scopus 로고
    • Characterization of human renal stones with MDCT: Advantage of dual energy and limitations due to respiratory motion
    • Grosjean R, Sauer B, Guerra RM, et al. Characterization of human renal stones with MDCT: advantage of dual energy and limitations due to respiratory motion. Am J Roentgenol. 2008;190:720-728.
    • (2008) Am J Roentgenol , vol.190 , pp. 720-728
    • Grosjean, R.1    Sauer, B.2    Guerra, R.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.