Volumn 76, Issue 6, 2014, Pages 1495-1506

Animal models to assess the local and systemic effects of nailing: Review of the literature and considerations for future studies

Author keywords

intramedullary stabilization; local effects; Long bone fracture; reaming; systemic effects

Indexed keywords

ARTICLE; BLOOD VESSEL PERMEABILITY; CALLUS; CORTICAL BONE; EQUIPMENT DESIGN; FAT EMBOLISM; FEMUR FRACTURE; FRACTURE EXTERNAL FIXATION; FRACTURE HEALING; INTRAMEDULLARY NAILING; LUNG CONTUSION; MULTIPLE TRAUMA; NONHUMAN; ORTHOPEDIC REAMER; OSTEOSYNTHESIS; PATHOPHYSIOLOGY; PRESSURE; PRIORITY JOURNAL; PULMONARY ARTERY OCCLUSION; REAMED NAILING; SURGICAL TECHNIQUE; SYSTEMATIC REVIEW; SYSTEMIC CIRCULATION; THERAPY EFFECT; TIBIA FRACTURE; UNREAMED NAILING; VASCULAR RESISTANCE; VENOUS CIRCULATION;

EID: 84902008335     PISSN: 21630755     EISSN: 21630763     Source Type: Journal    
DOI: 10.1097/TA.0000000000000236     Document Type: Article
Times cited : (5)

References (83)
  • 2
    • 34247630045 scopus 로고    scopus 로고
    • Cortical heat generation using an irrigating/aspirating single-pass reaming vs conventional stepwise reaming
    • Higgins TF, Casey V, Bachus K. Cortical heat generation using an irrigating/aspirating single-pass reaming vs conventional stepwise reaming. J Orthop Trauma. 2007;21(3):192-197.
    • (2007) J Orthop Trauma , vol.21 , Issue.3 , pp. 192-197
    • Higgins, T.F.1    Casey, V.2    Bachus, K.3
  • 3
    • 27544479523 scopus 로고    scopus 로고
    • Reamed femoral nailing in sheep: Does irrigation and aspiration of intramedullary contents alter the systemic response
    • Pape HC, Zelle BA, Hildebrand F, Giannoudis PV, Krettek C, van Griensven M. Reamed femoral nailing in sheep: does irrigation and aspiration of intramedullary contents alter the systemic response J Bone Joint Surg Am. 2005;87(11):2515-2522.
    • (2005) J Bone Joint Surg Am , vol.87 , Issue.11 , pp. 2515-2522
    • Pape, H.C.1    Zelle, B.A.2    Hildebrand, F.3    Giannoudis, P.V.4    Krettek, C.5    Van Griensven, M.6
  • 4
    • 33748149037 scopus 로고    scopus 로고
    • The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur
    • Husebye EE, Lyberg T, Madsen JE, Eriksen M, Roise O. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur. Injury. 2006;37(10):935-940.
    • (2006) Injury , vol.37 , Issue.10 , pp. 935-940
    • Husebye, E.E.1    Lyberg, T.2    Madsen, J.E.3    Eriksen, M.4    Roise, O.5
  • 5
    • 34548164399 scopus 로고    scopus 로고
    • Impact of the method of initial stabilization for femoral shaft fractures in patients with multiple injuries at risk for complications (borderline patients
    • discussion 499-501
    • Pape HC, Rixen D, Morley J, Husebye EE, Mueller M, Dumont C, Gruner A, Oestern HJ, Bayeff-Filoff M, Garving C, et al. Impact of the method of initial stabilization for femoral shaft fractures in patients with multiple injuries at risk for complications (borderline patients). Ann Surg. 2007; 246(3):491-499; discussion 499-501.
    • (2007) Ann Surg , vol.246 , Issue.3 , pp. 491-499
    • Pape, H.C.1    Rixen, D.2    Morley, J.3    Husebye, E.E.4    Mueller, M.5    Dumont, C.6    Gruner, A.7    Oestern, H.J.8    Bayeff-Filoff, M.9    Garving, C.10
  • 6
    • 0031785551 scopus 로고    scopus 로고
    • Pulmonary and systemic fat embolization after medullary canal pressurization: A hemodynamic and histologic investigation in the dog
    • Schemitsch EH, Turchin DC, Anderson GI, Byrick RJ, Mullen JB, Richards RR. Pulmonary and systemic fat embolization after medullary canal pressurization: a hemodynamic and histologic investigation in the dog. J Trauma. 1998;45(4):738-742.
    • (1998) J Trauma , vol.45 , Issue.4 , pp. 738-742
    • Schemitsch, E.H.1    Turchin, D.C.2    Anderson, G.I.3    Byrick, R.J.4    Mullen, J.B.5    Richards, R.R.6
  • 7
    • 0031691455 scopus 로고    scopus 로고
    • Quantitative assessment of bone injury and repair after reamed and unreamed locked intramedullary nailing
    • Schemitsch EH, Turchin DC, Kowalski MJ, Swiontkowski MF. Quantitative assessment of bone injury and repair after reamed and unreamed locked intramedullary nailing. J Trauma. 1998;45(2):250-255.
    • (1998) J Trauma , vol.45 , Issue.2 , pp. 250-255
    • Schemitsch, E.H.1    Turchin, D.C.2    Kowalski, M.J.3    Swiontkowski, M.F.4
  • 8
    • 0029245822 scopus 로고
    • A comparison of malreduction after plate and intramedullary nail fixation of forearm fractures
    • Schemitsch EH, Jones D, Henley MB, Tencer AF. A comparison of malreduction after plate and intramedullary nail fixation of forearm fractures. J Orthop Trauma. 1995;9(1):8-16.
    • (1995) J Orthop Trauma , vol.9 , Issue.1 , pp. 8-16
    • Schemitsch, E.H.1    Jones, D.2    Henley, M.B.3    Tencer, A.F.4
  • 9
    • 0029041927 scopus 로고
    • Comparison of the effect of reamed and unreamed locked intramedullary nailing on blood flow in the callus and strength of union following fracture of the sheep tibia
    • Schemitsch EH, Kowalski MJ, Swiontkowski MF, Harrington RM. Comparison of the effect of reamed and unreamed locked intramedullary nailing on blood flow in the callus and strength of union following fracture of the sheep tibia. J Orthop Res. 1995;13(3):382-389.
    • (1995) J Orthop Res , vol.13 , Issue.3 , pp. 382-389
    • Schemitsch, E.H.1    Kowalski, M.J.2    Swiontkowski, M.F.3    Harrington, R.M.4
  • 10
    • 0031745450 scopus 로고    scopus 로고
    • Reamed versus unreamed femoral nails. A randomised, prospective trial
    • Clatworthy MG, Clark DI, Gray DH, Hardy AE. Reamed versus unreamed femoral nails. A randomised, prospective trial. J Bone Joint Surg Br. 1998; 80(3):485-489.
    • (1998) J Bone Joint Surg Br , vol.80 , Issue.3 , pp. 485-489
    • Clatworthy, M.G.1    Clark, D.I.2    Gray, D.H.3    Hardy, A.E.4
  • 11
    • 67649643745 scopus 로고    scopus 로고
    • Intramedullary nailing of the femur: Current concepts concerning reaming
    • Rudloff MI, Smith WR. Intramedullary nailing of the femur: current concepts concerning reaming. J Orthop Trauma. 2009;23(Suppl 5):S12YS17.
    • (2009) J Orthop Trauma , vol.23 , Issue.SUPPL. 5
    • Rudloff, M.I.1    Smith, W.R.2
  • 12
    • 67349089620 scopus 로고    scopus 로고
    • Cortical perfusion and local fat occlusion after intramedullary nailing of the ovine tibiaVcomparison of different surgical procedures
    • Mueller CA, Schlegel V, Hoegel F, Eckhardt C, Schlegel U, Rahn BA, Pfister U, Suedkamp NP. Cortical perfusion and local fat occlusion after intramedullary nailing of the ovine tibiaVcomparison of different surgical procedures. Injury. 2009;40(7):760-766.
    • (2009) Injury , vol.40 , Issue.7 , pp. 760-766
    • Mueller, C.A.1    Schlegel, V.2    Hoegel, F.3    Eckhardt, C.4    Schlegel, U.5    Rahn, B.A.6    Pfister, U.7    Suedkamp, N.P.8
  • 13
    • 0030916231 scopus 로고    scopus 로고
    • Reamed against unreamed nailing of the femoral diaphysis: A retrospective study of healing time
    • Giannoudis PV, Furlong AJ, Macdonald DA, Smith RM. Reamed against unreamed nailing of the femoral diaphysis: a retrospective study of healing time. Injury. 1997;28(1):15-18.
    • (1997) Injury , vol.28 , Issue.1 , pp. 15-18
    • Giannoudis, P.V.1    Furlong, A.J.2    Macdonald, D.A.3    Smith, R.M.4
  • 15
    • 0032901903 scopus 로고    scopus 로고
    • Intramedullary pressure and bone marrow fat extravasation in reamed and unreamed femoral nailing
    • Kropfl A, Davies J, Berger U, Hertz H, Schlag G. Intramedullary pressure and bone marrow fat extravasation in reamed and unreamed femoral nailing. J Orthop Res. 1999;17(2):261-268.
    • (1999) J Orthop Res , vol.17 , Issue.2 , pp. 261-268
    • Kropfl, A.1    Davies, J.2    Berger, U.3    Hertz, H.4    Schlag, G.5
  • 18
    • 0029097876 scopus 로고
    • Intramedullary femoral nailing in sheep: Does severe injury predispose to pulmonary dysfunction
    • Pape HC, Dwenger A, Regel G, Remmers D, Tscherne H. Intramedullary femoral nailing in sheep: does severe injury predispose to pulmonary dysfunction Eur J Surg. 1995;161(3):163-171.
    • (1995) Eur J Surg , vol.161 , Issue.3 , pp. 163-171
    • Pape, H.C.1    Dwenger, A.2    Regel, G.3    Remmers, D.4    Tscherne, H.5
  • 19
    • 0036227047 scopus 로고    scopus 로고
    • Fat embolism and related effects during reamed and unreamed intramedullary nailing in a pig model
    • Buttaro M, Mocetti E, Alfie V, Paniego G, Pineiro L. Fat embolism and related effects during reamed and unreamed intramedullary nailing in a pig model. J Orthop Trauma. 2002;16(4):239-244.
    • (2002) J Orthop Trauma , vol.16 , Issue.4 , pp. 239-244
    • Buttaro, M.1    Mocetti, E.2    Alfie, V.3    Paniego, G.4    Pineiro, L.5
  • 20
    • 0342378147 scopus 로고    scopus 로고
    • Intramedullary pressure and bone marrow fat intravasation in unreamed femoral nailing
    • Kropfl A, Berger U, Neureiter H, Hertz H, Schlag G. Intramedullary pressure and bone marrow fat intravasation in unreamed femoral nailing. J Trauma. 1997;42(5):946-954.
    • (1997) J Trauma , vol.42 , Issue.5 , pp. 946-954
    • Kropfl, A.1    Berger, U.2    Neureiter, H.3    Hertz, H.4    Schlag, G.5
  • 21
    • 0029975371 scopus 로고    scopus 로고
    • Nailing versus plating in thoracic trauma: An experimental study in sheep
    • Neudeck F, Wozasek GE, Obertacke U, Thurnher M, Schlag G. Nailing versus plating in thoracic trauma: an experimental study in sheep. J Trauma. 1996;40(6):980-984.
    • (1996) J Trauma , vol.40 , Issue.6 , pp. 980-984
    • Neudeck, F.1    Wozasek, G.E.2    Obertacke, U.3    Thurnher, M.4    Schlag, G.5
  • 22
    • 29544452906 scopus 로고    scopus 로고
    • Effects of reamed or unreamed intramedullary nailing under non-damaged conditions on pulmonary function in sheep
    • Aoki S, Yokoyama K, Itoman M. Effects of reamed or unreamed intramedullary nailing under non-damaged conditions on pulmonary function in sheep. J Trauma. 2005;59(3):647-658.
    • (2005) J Trauma , vol.59 , Issue.3 , pp. 647-658
    • Aoki, S.1    Yokoyama, K.2    Itoman, M.3
  • 23
    • 78149361541 scopus 로고    scopus 로고
    • Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures
    • Hogel F, Gerlach UV, Sudkamp NP, Muller CA. Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures. Injury. 2010; 41(12):1317-1322.
    • (2010) Injury , vol.41 , Issue.12 , pp. 1317-1322
    • Hogel, F.1    Gerlach, U.V.2    Sudkamp, N.P.3    Muller, C.A.4
  • 24
    • 33748622585 scopus 로고    scopus 로고
    • Fat embolism: The reaming controversy
    • Giannoudis PV, Tzioupis C, Pape HC. Fat embolism: the reaming controversy. Injury. 2006;37(Suppl 4):S50YS58.
    • (2006) Injury , vol.37 , Issue.SUPPL. 4
    • Giannoudis, P.V.1    Tzioupis, C.2    Pape, H.C.3
  • 25
    • 4043124650 scopus 로고    scopus 로고
    • Rinsing-suction reamer attenuates intramedullary pressure increase and fat intravasation in a sheep model
    • Joist A, Schult M, Ortmann C, Frerichmann U, Frebel T, Spiegel HU, Kropfl A, Redl H. Rinsing-suction reamer attenuates intramedullary pressure increase and fat intravasation in a sheep model. J Trauma. 2004; 57(1):146-151.
    • (2004) J Trauma , vol.57 , Issue.1 , pp. 146-151
    • Joist, A.1    Schult, M.2    Ortmann, C.3    Frerichmann, U.4    Frebel, T.5    Spiegel, H.U.6    Kropfl, A.7    Redl, H.8
  • 27
    • 0036265807 scopus 로고    scopus 로고
    • Friction burns within the tibia during reaming. Are they affected by the use of a tourniquet
    • Giannoudis PV, Snowden S, Matthews SJ, Smye SW, Smith RM. Friction burns within the tibia during reaming. Are they affected by the use of a tourniquet J Bone Joint Surg Br. 2002;84(4):492-496.
    • (2002) J Bone Joint Surg Br , vol.84 , Issue.4 , pp. 492-496
    • Giannoudis, P.V.1    Snowden, S.2    Matthews, S.J.3    Smye, S.W.4    Smith, R.M.5
  • 28
    • 0032196505 scopus 로고    scopus 로고
    • Comparison of mechanical loads produced by current intramedullary reamer systems
    • Peindl RD, Harrow ME, Banks DM, Bosse MJ, Kellam JF. Comparison of mechanical loads produced by current intramedullary reamer systems. J Orthop Trauma. 1998;12(8):531-539.
    • (1998) J Orthop Trauma , vol.12 , Issue.8 , pp. 531-539
    • Peindl, R.D.1    Harrow, M.E.2    Banks, D.M.3    Bosse, M.J.4    Kellam, J.F.5
  • 29
  • 30
    • 0036780632 scopus 로고    scopus 로고
    • Effects of intramedullary femoral fracture fixation: What is the impact of experimental studies in regards to the clinical knowledge
    • Pape HC, Giannoudis PV, Grimme K, van Griensven M, Krettek C. Effects of intramedullary femoral fracture fixation: what is the impact of experimental studies in regards to the clinical knowledge Shock. 2002; 18(4):291-300.
    • (2002) Shock , vol.18 , Issue.4 , pp. 291-300
    • Pape, H.C.1    Giannoudis, P.V.2    Grimme, K.3    Van Griensven, M.4    Krettek, C.5
  • 31
    • 84865716113 scopus 로고    scopus 로고
    • The physiologic and pathologic effects of the reamer irrigator aspirator on fat embolism outcome: An animal study
    • Wang RY, Li R, Zdero R, Bell D, Blankstein M, Schemitsch EH. The physiologic and pathologic effects of the reamer irrigator aspirator on fat embolism outcome: an animal study. J Orthop Trauma. 2012;26(9):e132Ye137.
    • (2012) J Orthop Trauma , vol.26 , Issue.9
    • Wang, R.Y.1    Li, R.2    Zdero, R.3    Bell, D.4    Blankstein, M.5    Schemitsch, E.H.6
  • 32
    • 61549115021 scopus 로고    scopus 로고
    • The stress response to bilateral femoral fractures: A comparison of primary intramedullary nailing and external fixation
    • discussion 98-99
    • Gray AC, White TO, Clutton E, Christie J, Hawes BD, Robinson CM. The stress response to bilateral femoral fractures: a comparison of primary intramedullary nailing and external fixation. J Orthop Trauma. 2009;23(2): 90-97; discussion 98-99.
    • (2009) J Orthop Trauma , vol.23 , Issue.2 , pp. 90-97
    • Gray, A.C.1    White, T.O.2    Clutton, E.3    Christie, J.4    Hawes, B.D.5    Robinson, C.M.6
  • 33
    • 20044375547 scopus 로고    scopus 로고
    • Secondary effects of femoral instrumentation on pulmonary physiology in a standardised sheep model: What is the effect of lung contusion and reaming
    • Hildebrand F, Giannoudis P, van Griensven M, Chawda M, Probst C, Harms O, Harwood P, Otto K, Fehr M, Krettek C, et al. Secondary effects of femoral instrumentation on pulmonary physiology in a standardised sheep model: what is the effect of lung contusion and reaming Injury. 2005;36(4):544-555.
    • (2005) Injury , vol.36 , Issue.4 , pp. 544-555
    • Hildebrand, F.1    Giannoudis, P.2    Van Griensven, M.3    Chawda, M.4    Probst, C.5    Harms, O.6    Harwood, P.7    Otto, K.8    Fehr, M.9    Krettek, C.10
  • 36
    • 0030811954 scopus 로고    scopus 로고
    • Pulmonary effects of fixation of a fracture with a plate compared with intramedullary nailing. A canine model of fat embolism and fracture fixation
    • Schemitsch EH, Jain R, Turchin DC, Mullen JB, Byrick RJ, Anderson GI, Richards RR. Pulmonary effects of fixation of a fracture with a plate compared with intramedullary nailing. A canine model of fat embolism and fracture fixation. J Bone Joint Surg Am. 1997;79(7):984-996.
    • (1997) J Bone Joint Surg Am , vol.79 , Issue.7 , pp. 984-996
    • Schemitsch, E.H.1    Jain, R.2    Turchin, D.C.3    Mullen, J.B.4    Byrick, R.J.5    Anderson, G.I.6    Richards, R.R.7
  • 39
    • 0032020021 scopus 로고    scopus 로고
    • Reamed intramedullary femoral nailing after induction of an "aRDS-like" state in sheep: Effect on clinically applicable markers of pulmonary function
    • discussion 175-176
    • Wolinsky PR, Banit D, Parker RE, Shyr Y, Snapper JR, Rutherford EJ, Johnson KD. Reamed intramedullary femoral nailing after induction of an "ARDS-like" state in sheep: effect on clinically applicable markers of pulmonary function. J Orthop Trauma. 1998;12(3):169-175; discussion 175-176.
    • (1998) J Orthop Trauma , vol.12 , Issue.3 , pp. 169-175
    • Wolinsky, P.R.1    Banit, D.2    Parker, R.E.3    Shyr, Y.4    Snapper, J.R.5    Rutherford, E.J.6    Johnson, K.D.7
  • 42
    • 78649477914 scopus 로고    scopus 로고
    • The effect of muscle contusion on cortical bone and muscle perfusion following reamed, intramedullary nailing: A novel canine tibia fracture model
    • Koo H, Hupel T, Zdero R, Tov A, Schemitsch EH. The effect of muscle contusion on cortical bone and muscle perfusion following reamed, intramedullary nailing: a novel canine tibia fracture model. J Orthop Surg Res. 2010;5:89.
    • (2010) J Orthop Surg Res , vol.5 , pp. 89
    • Koo, H.1    Hupel, T.2    Zdero, R.3    Tov, A.4    Schemitsch, E.H.5
  • 44
    • 0141633848 scopus 로고    scopus 로고
    • Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: The effect of draining the medullary contents before reaming
    • Mueller CA, Rahn BA. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming. J Trauma. 2003; 55(3):495-503.
    • (2003) J Trauma , vol.55 , Issue.3 , pp. 495-503
    • Mueller, C.A.1    Rahn, B.A.2
  • 45
    • 0028903429 scopus 로고
    • The effect of bone marrow embolization on the choice of procedure in the stabilization of femoral fractures
    • [in German]
    • Wenda K, Runkel M, Rudig L, Degreif J. The effect of bone marrow embolization on the choice of procedure in the stabilization of femoral fractures [in German]. Orthopade. 1995;24(2):151-163.
    • (1995) Orthopade , vol.24 , Issue.2 , pp. 151-163
    • Wenda, K.1    Runkel, M.2    Rudig, L.3    Degreif, J.4
  • 46
    • 0034814914 scopus 로고    scopus 로고
    • The coagulative and cardiorespiratory responses to reamed intramedullary nailing of isolated fractures
    • Robinson CM, Ludlam CA, Ray DC, Swann DG, Christie J. The coagulative and cardiorespiratory responses to reamed intramedullary nailing of isolated fractures. J Bone Joint Surg Br. 2001;83(7):963-973.
    • (2001) J Bone Joint Surg Br , vol.83 , Issue.7 , pp. 963-973
    • Robinson, C.M.1    Ludlam, C.A.2    Ray, D.C.3    Swann, D.G.4    Christie, J.5
  • 48
    • 78650255817 scopus 로고    scopus 로고
    • Intravasation of bone marrow content Can its magnitude and effects be modulated by low pressure reaming in a porcine model
    • Husebye EE, Lyberg T, Opdahl H, Roise O. Intravasation of bone marrow content. Can its magnitude and effects be modulated by low pressure reaming in a porcine model Injury. 2010;41(Suppl 2):S9YS15.
    • (2010) Injury , vol.41 , Issue.SUPPL. 2
    • Husebye, E.E.1    Lyberg, T.2    Opdahl, H.3    Roise, O.4
  • 49
    • 0025097091 scopus 로고
    • Pulmonary endothelial injury and altered fibrinolysis after femur fracture in rabbits
    • Williams JJ, Moalli R, Calista C, Herndon JH. Pulmonary endothelial injury and altered fibrinolysis after femur fracture in rabbits. J Orthop Trauma. 1990;4(3):303-308.
    • (1990) J Orthop Trauma , vol.4 , Issue.3 , pp. 303-308
    • Williams, J.J.1    Moalli, R.2    Calista, C.3    Herndon, J.H.4
  • 50
    • 0019444629 scopus 로고
    • Increased pulmonary vascular permeability after bone marrow injection in sheep
    • Barie PS, Minnear FL, Malik AB. Increased pulmonary vascular permeability after bone marrow injection in sheep. Am Rev Respir Dis. 1981; 123(6):648-653.
    • (1981) Am Rev Respir Dis , vol.123 , Issue.6 , pp. 648-653
    • Barie, P.S.1    Minnear, F.L.2    Malik, A.B.3
  • 51
    • 0018360765 scopus 로고
    • Pulmonary neutral fat embolism in dogs
    • Jacobovitz-Derks D, Derks CM. Pulmonary neutral fat embolism in dogs. Am J Pathol. 1979;95(1):29-42.
    • (1979) Am J Pathol , vol.95 , Issue.1 , pp. 29-42
    • Jacobovitz-Derks, D.1    Derks, C.M.2
  • 52
    • 0029016876 scopus 로고
    • Intramedullary nailing and pulmonary embolism: Does unreamed nailing prevent embolization An in vivo study in rabbits
    • Heim D, Regazzoni P, Tsakiris DA, Aebi T, Schlegel U, Marbet GA, Perren SM. Intramedullary nailing and pulmonary embolism: does unreamed nailing prevent embolization An in vivo study in rabbits. J Trauma. 1995;38(6):899-906.
    • (1995) J Trauma , vol.38 , Issue.6 , pp. 899-906
    • Heim, D.1    Regazzoni, P.2    Tsakiris, D.A.3    Aebi, T.4    Schlegel, U.5    Marbet, G.A.6    Perren, S.M.7
  • 54
    • 0027930305 scopus 로고
    • Pulmonary reaction during intramedullary fracture management in traumatic shock: An experimental study
    • Wozasek GE, Thurnher M, Redl H, Schlag G. Pulmonary reaction during intramedullary fracture management in traumatic shock: an experimental study. J Trauma. 1994;37(2):249-254.
    • (1994) J Trauma , vol.37 , Issue.2 , pp. 249-254
    • Wozasek, G.E.1    Thurnher, M.2    Redl, H.3    Schlag, G.4
  • 55
    • 0028324969 scopus 로고
    • Intramedullary pressure changes and fat intravasation during intramedullary nailing: An experimental study in sheep
    • Wozasek GE, Simon P, Redl H, Schlag G. Intramedullary pressure changes and fat intravasation during intramedullary nailing: an experimental study in sheep. J Trauma. 1994;36(2):202-207.
    • (1994) J Trauma , vol.36 , Issue.2 , pp. 202-207
    • Wozasek, G.E.1    Simon, P.2    Redl, H.3    Schlag, G.4
  • 56
    • 0032774173 scopus 로고    scopus 로고
    • Stimulation of the inflammatory system by reamed and unreamed nailing of femoral fractures. An analysis of the second hit
    • Giannoudis PV, Smith RM, Bellamy MC, Morrison JF, Dickson RA, Guillou PJ. Stimulation of the inflammatory system by reamed and unreamed nailing of femoral fractures. An analysis of the second hit. J Bone Joint Surg Br. 1999;81(2):356-361.
    • (1999) J Bone Joint Surg Br , vol.81 , Issue.2 , pp. 356-361
    • Giannoudis, P.V.1    Smith, R.M.2    Bellamy, M.C.3    Morrison, J.F.4    Dickson, R.A.5    Guillou, P.J.6
  • 58
    • 0033771362 scopus 로고    scopus 로고
    • Technical innovations in medullary reaming: Reamer design and intramedullary pressure increase
    • Muller CA, Baumgart F, Wahl D, Perren SM, Pfister U. Technical innovations in medullary reaming: reamer design and intramedullary pressure increase. J Trauma. 2000;49(3):440-445.
    • (2000) J Trauma , vol.49 , Issue.3 , pp. 440-445
    • Muller, C.A.1    Baumgart, F.2    Wahl, D.3    Perren, S.M.4    Pfister, U.5
  • 60
    • 77958154917 scopus 로고    scopus 로고
    • Cardiopulmonary response to reamed intramedullary nailing of the femur comparing traditional reaming with a one-step reamer-irrigator-aspirator reaming system: An experimental study in pigs
    • Husebye EE, Lyberg T, Opdahl H, Laurvik H, Roise O. Cardiopulmonary response to reamed intramedullary nailing of the femur comparing traditional reaming with a one-step reamer-irrigator-aspirator reaming system: an experimental study in pigs. J Trauma. 2010;69(4):E6YE14.
    • (2010) J Trauma , vol.69 , Issue.4
    • Husebye, E.E.1    Lyberg, T.2    Opdahl, H.3    Laurvik, H.4    Roise, O.5
  • 61
    • 0036737772 scopus 로고    scopus 로고
    • Changes in the management of femoral shaft fractures in polytrauma patients: From early total care to damage control orthopedic surgery
    • discussion 461-462
    • Pape HC, Hildebrand F, Pertschy S, Zelle B, Garapati R, Grimme K, Krettek C, Reed RL 2nd. Changes in the management of femoral shaft fractures in polytrauma patients: from early total care to damage control orthopedic surgery. J Trauma. 2002;53(3):452-461; discussion 461-462.
    • (2002) J Trauma , vol.53 , Issue.3 , pp. 452-461
    • Pape, H.C.1    Hildebrand, F.2    Pertschy, S.3    Zelle, B.4    Garapati, R.5    Grimme, K.6    Krettek, C.7    Reed II, R.L.8
  • 62
    • 0038785690 scopus 로고    scopus 로고
    • Impact of intramedullary instrumentation versus damage control for femoral fractures on immunoinflammatory parameters: Prospective randomized analysis by the EPOFF Study Group
    • Pape HC, Grimme K, Van Griensven M, Sott AH, Giannoudis P, Morley J, Roise O, Ellingsen E, Hildebrand F, Wiese B, et al. Impact of intramedullary instrumentation versus damage control for femoral fractures on immunoinflammatory parameters: prospective randomized analysis by the EPOFF Study Group. J Trauma. 2003;55(1):7-13.
    • (2003) J Trauma , vol.55 , Issue.1 , pp. 7-13
    • Pape, H.C.1    Grimme, K.2    Van Griensven, M.3    Sott, A.H.4    Giannoudis, P.5    Morley, J.6    Roise, O.7    Ellingsen, E.8    Hildebrand, F.9    Wiese, B.10
  • 64
    • 0027230751 scopus 로고
    • Repeated routine determination of pulmonary microvascular permeability after polytrauma
    • [in German]
    • Obertacke U, Kleinschmidt C, Dresing K, Bardenheuer M, Bruch J. Repeated routine determination of pulmonary microvascular permeability after polytrauma [in German]. Unfallchirurg. 1993;96(3):142-149.
    • (1993) Unfallchirurg , vol.96 , Issue.3 , pp. 142-149
    • Obertacke, U.1    Kleinschmidt, C.2    Dresing, K.3    Bardenheuer, M.4    Bruch, J.5
  • 65
    • 0034004107 scopus 로고    scopus 로고
    • External fixation as a bridge to intramedullary nailing for patients with multiple injuries and with femur fractures: Damage control orthopedics
    • discussion 621-623
    • Scalea TM, Boswell SA, Scott JD, Mitchell KA, Kramer ME, Pollak AN. External fixation as a bridge to intramedullary nailing for patients with multiple injuries and with femur fractures: damage control orthopedics. J Trauma. 2000;48(4):613-621; discussion 621-623.
    • (2000) J Trauma , vol.48 , Issue.4 , pp. 613-621
    • Scalea, T.M.1    Boswell, S.A.2    Scott, J.D.3    Mitchell, K.A.4    Kramer, M.E.5    Pollak, A.N.6
  • 66
    • 0035127845 scopus 로고    scopus 로고
    • Callus development after bored and unbored femoral interlocking nailing. An experimental study
    • [in German]
    • Kropfl A, Hertz H, Redl H, Schlag G. Callus development after bored and unbored femoral interlocking nailing. An experimental study [in German]. Unfallchirurg. 2001;104(1):41-49.
    • (2001) Unfallchirurg , vol.104 , Issue.1 , pp. 41-49
    • Kropfl, A.1    Hertz, H.2    Redl, H.3    Schlag, G.4
  • 67
    • 0024046059 scopus 로고
    • Form and dimension of the bone marrow cavity of the human femur with reference to the fit of intramedullary implants
    • [in German]
    • Zuber K, Schneider E, Eulenberger J, Perren SM. Form and dimension of the bone marrow cavity of the human femur with reference to the fit of intramedullary implants [in German]. Unfallchirurg. 1988;91(7):314-319.
    • (1988) Unfallchirurg , vol.91 , Issue.7 , pp. 314-319
    • Zuber, K.1    Schneider, E.2    Eulenberger, J.3    Perren, S.M.4
  • 68
    • 33646759608 scopus 로고    scopus 로고
    • Large animal models: Baboons for trauma, shock, and sepsis studies
    • Redl H, Bahrami S. Large animal models: baboons for trauma, shock, and sepsis studies. Shock. 2005;24(Suppl 1):88-93.
    • (2005) Shock , vol.24 , Issue.SUPPL. 1 , pp. 88-93
    • Redl, H.1    Bahrami, S.2
  • 70
    • 0031763862 scopus 로고    scopus 로고
    • Interspecies differences in bone composition, density, and quality: Potential implications for in vivo bone research
    • Aerssens J, Boonen S, Lowet G, Dequeker J. Interspecies differences in bone composition, density, and quality: potential implications for in vivo bone research. Endocrinology. 1998;139(2):663-670.
    • (1998) Endocrinology , vol.139 , Issue.2 , pp. 663-670
    • Aerssens, J.1    Boonen, S.2    Lowet, G.3    Dequeker, J.4
  • 71
    • 0031984732 scopus 로고    scopus 로고
    • The role of methylmethacrylate monomer in the formation and haemodynamic outcome of pulmonary fat emboli
    • Elmaraghy AW, Humeniuk B, Anderson GI, Schemitsch EH, Richards RR. The role of methylmethacrylate monomer in the formation and haemodynamic outcome of pulmonary fat emboli. J Bone Joint Surg Br. 1998; 80(1):156-161.
    • (1998) J Bone Joint Surg Br , vol.80 , Issue.1 , pp. 156-161
    • Elmaraghy, A.W.1    Humeniuk, B.2    Anderson, G.I.3    Schemitsch, E.H.4    Richards, R.R.5
  • 72
    • 0027853009 scopus 로고
    • Pathogenesis and clinical relevance of bone marrow embolism in medullary nailingVdemonstrated by intraoperative echocardiography
    • Wenda K, Runkel M, Degreif J, Ritter G. Pathogenesis and clinical relevance of bone marrow embolism in medullary nailingVdemonstrated by intraoperative echocardiography. Injury. 1993;24(Suppl 3):S73YS81.
    • (1993) Injury , vol.24 , Issue.SUPPL. 3
    • Wenda, K.1    Runkel, M.2    Degreif, J.3    Ritter, G.4
  • 73
    • 33646843614 scopus 로고    scopus 로고
    • Gene expression during fracture healing in rats comparing intramedullary fixation to plate fixation by DNA microarray
    • Heiner DE, Meyer MH, Frick SL, Kellam JF, Fiechtl J, Meyer RA Jr. Gene expression during fracture healing in rats comparing intramedullary fixation to plate fixation by DNA microarray. J Orthop Trauma. 2006; 20(1):27-38.
    • (2006) J Orthop Trauma , vol.20 , Issue.1 , pp. 27-38
    • Heiner, D.E.1    Meyer, M.H.2    Frick, S.L.3    Kellam, J.F.4    Fiechtl, J.5    Meyer Jr., R.A.6
  • 74
    • 84872778595 scopus 로고    scopus 로고
    • Conversion from external fixator to intramedullary nail causes a second hit and impairs fracture healing in a severe trauma model
    • Recknagel S, Bindl R, Wehner T, Gockelmann M, Wehrle E, Gebhard F, Huber-Lang M, Claes L, Ignatius A. Conversion from external fixator to intramedullary nail causes a second hit and impairs fracture healing in a severe trauma model. J Orthop Res. 2013;31(3):465-471.
    • (2013) J Orthop Res , vol.31 , Issue.3 , pp. 465-471
    • Recknagel, S.1    Bindl, R.2    Wehner, T.3    Gockelmann, M.4    Wehrle, E.5    Gebhard, F.6    Huber-Lang, M.7    Claes, L.8    Ignatius, A.9
  • 75
    • 78649578122 scopus 로고    scopus 로고
    • The Effect of timing of conversion from external fixation to secondary intramedullary nailing in experimental tibial fractures
    • Sigurdsen U, Reikeras O, Utvag SE. The Effect of timing of conversion from external fixation to secondary intramedullary nailing in experimental tibial fractures. J Orthop Res. 2011;29(1):126-130.
    • (2011) J Orthop Res , vol.29 , Issue.1 , pp. 126-130
    • Sigurdsen, U.1    Reikeras, O.2    Utvag, S.E.3
  • 77
    • 84887820688 scopus 로고    scopus 로고
    • Differentiation of osteoprogenitor cells is affected by trauma-haemorrhage
    • Neunaber C, Yesilkaya P, Putz C, Krettek C, Hildebrand F. Differentiation of osteoprogenitor cells is affected by trauma-haemorrhage. Injury. 2013;44:1279-1284.
    • (2013) Injury , vol.44 , pp. 1279-1284
    • Neunaber, C.1    Yesilkaya, P.2    Putz, C.3    Krettek, C.4    Hildebrand, F.5
  • 78
    • 52449093431 scopus 로고    scopus 로고
    • The role of fracture-associated soft tissue injury in the induction of systemic inflammation and remote organ dysfunction after bilateral femur fracture
    • Kobbe P, Vodovotz Y, Kaczorowski DJ, Billiar TR, Pape HC. The role of fracture-associated soft tissue injury in the induction of systemic inflammation and remote organ dysfunction after bilateral femur fracture. J Orthop Trauma. 2008;22(6):385-390.
    • (2008) J Orthop Trauma , vol.22 , Issue.6 , pp. 385-390
    • Kobbe, P.1    Vodovotz, Y.2    Kaczorowski, D.J.3    Billiar, T.R.4    Pape, H.C.5
  • 80
    • 0025242488 scopus 로고
    • Reaming versus non-reaming in medullary nailing: Interference with cortical circulation of the canine tibia
    • Klein MP, Rahn BA, Frigg R, Kessler S, Perren SM. Reaming versus non-reaming in medullary nailing: interference with cortical circulation of the canine tibia. Arch Orthop Trauma Surg. 1990;109(6):314-316.
    • (1990) Arch Orthop Trauma Surg , vol.109 , Issue.6 , pp. 314-316
    • Klein, M.P.1    Rahn, B.A.2    Frigg, R.3    Kessler, S.4    Perren, S.M.5
  • 81
    • 0025928115 scopus 로고
    • Compartment syndrome after closed intramedullary nailing of the tibia: A canine model and report of two cases
    • Moed BR, Strom DE. Compartment syndrome after closed intramedullary nailing of the tibia: a canine model and report of two cases. J Orthop Trauma. 1991;5(1):71-77.
    • (1991) J Orthop Trauma , vol.5 , Issue.1 , pp. 71-77
    • Moed, B.R.1    Strom, D.E.2
  • 82
    • 0028528922 scopus 로고
    • Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: A fractured tibia model in sheep
    • Schemitsch EH, Kowalski MJ, Swiontkowski MF, Senft D. Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: a fractured tibia model in sheep. J Orthop Trauma. 1994;8(5): 373-382.
    • (1994) J Orthop Trauma , vol.8 , Issue.5 , pp. 373-382
    • Schemitsch, E.H.1    Kowalski, M.J.2    Swiontkowski, M.F.3    Senft, D.4
  • 83
    • 0032916680 scopus 로고    scopus 로고
    • Effect of femoral fracture and intramedullary fixation on lung capillary leak
    • Willis BH, Carden DL, Sadasivan KK. Effect of femoral fracture and intramedullary fixation on lung capillary leak. J Trauma. 1999;46(4): 687-692.
    • (1999) J Trauma , vol.46 , Issue.4 , pp. 687-692
    • Willis, B.H.1    Carden, D.L.2    Sadasivan, K.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.